Tender For Cleaning And Repairs To Sewage Line Septic Tank Manholes Blockages Of Nahani Traps Gully Traps Sewage Lines And Drainage Pipelines Etc Under Age Br I Of Ge Brichgunj, South Andamans-Andaman And Nicobar Islands

Military Engineer Services-MES has published Tender For Cleaning And Repairs To Sewage Line Septic Tank Manholes Blockages Of Nahani Traps Gully Traps Sewage Lines And Drainage Pipelines Etc Under Age Br I Of Ge Brichgunj. Submission Date for this Tender is 17-05-2024. Pipe Laying Tenders in South Andamans Andaman And Nicobar Islands. Bidders can get complete Tender details and download the document.




Tender Notice

43248325
Tender For Cleaning And Repairs To Sewage Line Septic Tank Manholes Blockages Of Nahani Traps Gully Traps Sewage Lines And Drainage Pipelines Etc Under Age Br I Of Ge Brichgunj
Open Tender
Indian
Andaman And Nicobar Islands
South Andamans
17-05-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Tender For Cleaning And Repairs To Sewage Line Septic Tank Manholes Blockages Of Nahani Traps Gully Traps Sewage Lines And Drainage Pipelines Etc Under Age Br I Of Ge Brichgunj

Key Value

Document Fees
INR 500 /-
EMD
INR 80000.0 /-
Tender Value
INR 40 Lakhs /-

Attachment

FileName File Description File Size
3c5dd9ab-0514-479b-8f7d-4408797725e3.html Tender Notice 0 KB
8472Atenderdoc.pdf Tender Document 0 KB
BOQ_729047.xls Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

Name of Work:CLEANING AND REPAIRS TO SEWAGE LINE, SEPTIC TANK, MANHOLES, BLOCKAGES OF NAHANI TRAPS, GULLY TRAPS, SEWAGE LINES AND DRAINAGE PIPELINES ETC UNDER AGE B/R-I OF GE BRICHGUNJ
Sl. No. Item Description
1M & L for removing/Bailing out/pumping outsludge liquid, solid and waste material from septic tank, pumping into honey sucker mechanical transport vehicle and depositing at Ranjit Vihar STP at a distance exceeding 50m and not exceeding 5000m where directed including minor repairs on plaster, rungs, cleaning the bottom and sides of the septic tanks (inner side) with wire brushes to remove all scales dirt, etc complete all as specified and directed by Engineer-in-Charge for the following capacity of septic tank :- 500 Users
2All are per item no 1.00 here in before but250 users
3All are per item no 1.00 here in before but 200 users
4All are per item no 1.00 here in before but 150 users
5All are per item no 1.00 here in before but 100 users
6All are per item no 1.00 here in before but 50 users
7All are per item no 1.00 here in before but 25 users
8All are per item no 1.00 here in before but10 users
9Removing carefully the cover slabs of man holes of any size and shape and removing the scum/ sludge including any organic or inorganic matters to a distance exc 50m and not exc 5000m and depositing where as directed by engineer in charge, and setting the man hole cover in position in CM (1:6) after cleaning the sludge for the following size of man holes (Manhole cover if provided new shallbe measured & paid seperately) :- a) "Upto 1.5 mtr depth
10As per item No.09.00 here in before but "Exc 1.5 mtr depth but n.exc 3.00 meter depth
11Cleaning of blocked sewage drain pipe till the flow of sewage/sludge water is smooth including taking out all sludge/mud from pipes by means of roding & remove to a distance exc 50m and not exc 5000m and depositing where as directed by engineer in chargefor following size of pipes :- " Internal dia 75 mm
12As per item No. 11.00 here in before but Internal dia 100mm
13As per item No. 11.00 here in before but Internal dia 150mm
14As per item No. 11.00 here in before but Internal dia 200 mm
15Cleaning and removing of blockage from WC upto first manhole removing all silt, liquid mud from the pipe line by roding etc and depositing the same at a distance exc 50m and not exc 5000 mtrswhere as directed by engineer in charge for following:- In Ground Floor
16As per item No. 15.00 here in before but In First Floor
17As per item No. 15.00 here in before but In Second Floor
18Cleaning and removing of blockage from floor trap at any location upto first manhole removing all silt, liquid mud or any othe foreign materials by roding and removing the same at a distance exc 50m and not exc 5000 mtrsand depositing where as directed by engineer in charge for following:- "In Ground Floor
19As per item No. 18.00 here in before but In First Floor
20As per item No. 18.00 here in before but In Second Floor
21Taking out carefully the cover slab of gulley traps of any size and shape, depth and cleaning of blocked Gully traps including taking out all sludge/mud by means of roding,remove to a distance exc 50m and not exc 5000 mtrs and depositing where as directed by engineer in charge
22Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5 M depth for foundation, etc., and getting out in soft/looseall as specified and as directed.
23As per item No.22.00 here in before but depth exceeding 1.5 metre and n.exc 3m all as specified and as directed.
24Dismantling of cast iron pipe of internal dia 150 mm jointed in CM and taking out of trenches etc complete all as specified.
25Dismantling of cast iron pipe of internal dia 100 mm jointed in CM and taking out of trenches etc complete all as specified.
26Dismantling of cast iron pipe of internal dia 100 mm jointed in CM fixed to wall and taking out from wall etc complete all as specified.
27Dismantling of cast iron pipe of internal dia 75 mm jointed in CM fixed to wall and taking out from wall etc complete all as specified.
28M&L for PCC (1:3:6) type C2 using 40mm graded stone aggregate as in bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 100mm bore of pipes all as specified and as directed.
29As per item No.28.00 here in before but but 150mm bore pipes
30M&L for 150mm bore sand cast iron pipe, in any length with or without ears, with cement joints, laid in trenches or in floors including testing of pipe etc complete all as specified and directed
31As per item No.30.00 here in before but but 100mm bore of pipe all as specified and as directed.
32M&L for 100mm bore sand cast iron pipe, in any length with or without ears, with cement joints, fixed to walls including testing of pipe etc complete all as specified and directed
33As per item No.32.00 here in before but 75mm bore of pipe all as specified and as directed.
34S&F in repair CI bend (any radius) bore of pipe 100mm with oval access door all as specified and directed.
35S&F in repairs CI bend with duck"s foot or heel rest bore of pipe 75mm with oval access door all as specified and directed.
36S&F in repairs 100mm bore CI pipe single/Tee, branch pieces(Equal or unequal) ordinary or inverted(spigot or socket type) or with parallel branches and jointed complete all as specified and directed.
37As per item No.36.00 here in before but 75mm bore of pipe all as specified and directed.
38S&F in repair 100mm bore CI pipe double branch pieces single "Y" (Equal or unequal) ordinary or inverted(spigot or socket type) or with parallel branches and jointed complete all as specified and directed.
39S&F in repairs CI Cowls 100mm bore of pipe all as specified and directed.
40S&Fin repairs CI Cowls 75mm bore of pipe all as specified and directed.
41Demolition of Solid block masonry set in CM as in man hole chamber and septic tank etc as in walling all as specified and directed
42M&L for precast cement concreteblock masonry with PCC 1:3:6,type C1, with solid blocks exc 10cm in width and set in CM (1:4) all as specified and directed.
43Taking down cement plaster of any description from wall including raking out joints hacking for key, scrubbing down with water etc, complete all as specified and directed.
44M&L for rendering 15mm thick in CM (1:3) on concrete/brick / solid block masonry surfaces as in manhole, septic tank etc finished even and smooth without using extra cement all as specified and directed.
45M&L for rendering 15mm thick in CM (1:6) on concrete/brick/Solid block masnory wall surfaces finished even and fair all as specified and directed.
46M&L for preparation of new plastered surfaces of walls and applying two coats of white wash, complete all as specified and as directed
47Demolition of cement concrete reinforced of any description and in any position complete all as specified and as directed.
48M&L for providing precast RCC (1:2:4) type B1 using 20mm graded stone aggregate as in cover slab for manholes, septic tank and similar work set in CM (1:6) all as specified incl necessary form work and placed in position all as directed
49M&L for mild steel TMT bars 10mm dia and over cut to length, bent to shape required including cranking and bending spirally for hopping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.90mm dia) or securing with clips complete.
50Returning, filling in, incl spreading, levelling, watering and well ramming in layers n.exc 25cm thick with soils all as specified and directed.
51Removing excavated soils to a distance n.exc 50M and depositing where directed at a level n.exc 1.5M above the starting point all as specified and directed.
52M&L for CI gully traps in repairs square or round mouthed of size 150 x 150 mm, type "P" incl making good the disturbed surfaces like plinth protection all as specified and directed.
53Cutting of small trees/plants at the stem removal of the roots of the plants by using acids, cutting around the spout for removing the roots of any size and making good with CM (1:3) incl two coats of cement base paint complete all as directed by Engineer-in-Charge
54S & F in repairs PVC (SWR) pipes 110 mm bore single socketed, in any length with rubber ring joints fixed to walls complete all as specified and as directed
55As per item No.54.00 here in before but 75mm bore
56S & F in repairs PVC (SWR) pipes 150 mmbore single socketed, in any length with rubber ring joints laid in trenches or in floors complete all as specified and as directed
57S & F in repairs PVC (SWR) bend of any radius with oval access door, 110mm boreall as specified and as directed
58As per item No.57.00 here in before but 75mm bore
59S & F in repairs 110mm bore PVC (SWR) junction, (Single "T") equal or unequal all as specified and as directed
60As per item No.59.00 here in before but 75mm bore
61Demolition of cement concrete (unreinforced) in ground floors and pavings not exc. 15cm thickness etc below or above ground level incl floor hearth tiles if any and removing the rubbish off the premises complete all as specified and as directed by Engr-In -Charge.
62M&L plain cement concrete (1:4:8) type D2 using 40mm graded stone aggregate as in foundation.
63M&L for PCC (1:2:4) type B-1 using 20mm graded stone aggregates as in benching, haunching and channel etc finished even and smooth using extra cement including necessary form work.
64M&L for PCC 1:3:6 type C1 using 20mm graded stone aggregate as in coping etc , rounded or chamferedon edges all as directed
65M&L for Plain cement concrete 1:3:6, type C2, using 40 mm graded stone aggregate, as in surface channels/drains etc, complete all as specified
66S&F in repairs mild steel chromium plated gratings fixed in cement mortar or coloured cement mortar to match with the existing surfaces complete all as specified.
67M&L for rendering 10 mm thick in CM 1:4 on concrete or block masonry surfaces finished even and smooth without using extra cement complete all as specified.
68Cutting of bushes, grass and trees bunches etc all along the drain etc. all as directed.
69Demolition of cement concrete of any description and in any position not otherwise specially provided complete all as specified and directed.
70M&L for PCC 1:5:10, type E2, using 40 mm graded stone aggregate as in filling of sunken portion of slab etc complete
71M&L for PCC 1:2:4, type B1, 40 mm thick, using 20 mm graded aggregate as in floor for laying floor finishes complete all as specified.
72M&L for PCC 1:2:4, type B2, 100 mm thick, using 40 mm graded aggregate as in floor for laying floor finishes complete all as specified.
73M&L for cast iron floor trap 100 mm outlet dia with grating including jointing to waste pipe fixed in cement concrete type B1 (1:2:4)
74M&L for PVC (SWR) floor trap 100 mm outlet dia with grating including jointing to waste pipe fixed in cement concrete type B1 (1:2:4)
75M&L for cast iron Nahani trap 100 mm outlet dia with grating including jointing to waste pipe fixed in cement concrete type B1 (1:2:4)
76M&L for PVC (SWR) multi floor trap 100 mm outlet dia with grating including jointing to waste pipe fixed in cement concrete type B1 (1:2:4)
77M&L for PVC (SWR) floor trap, 75 mm outlet dia plain with grating including jointing with solvent cement
78M&L for PCC 1:4:8, type D2, 75 mm thick as in sub base of floor, plinth protection pavings etc
79Dismantling stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed complete all as specified and as directed by Engr-In-Charge.
80Material & labourfor designer coloured chequred cement concrete tiles of size 30 cm x 30 cm x 25 mm with jointed and pointed in neat cement slurry with grey cement and pigment to match the shade including screed bed 20mm in CM (1:4)all as specified and directed.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail