}

Tender For Day To Day Complaints Of Internal Electric Supply And Allied Works At Tibri Mil Stn Under Ge Gurdaspur., gurdaspur-Punjab

Military Engineer Services-MES has published Tender For Day To Day Complaints Of Internal Electric Supply And Allied Works At Tibri Mil Stn Under Ge Gurdaspur.. Submission Date for this Tender is 16-05-2024. Electrification Work Tenders in gurdaspur Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

43248294
Corrigendum : Tender For Day To Day Complaints Of Internal Electric Supply And Allied Works At Tibri Mil Stn Under Ge Gurdaspur.
Open Tender
Indian
Punjab
gurdaspur
16-05-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Tender For Day To Day Complaints Of Internal Electric Supply And Allied Works At Tibri Mil Stn Under Ge Gurdaspur.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 07-May-2024 Corrigendum No 1 Other 16-05-2024
2 07-May-2024 Corrigendum No 1 BOQ 16-05-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 90000.0 /-
Tender Value
INR 45 Lakhs /-

Attachment

FileName File Description File Size
febafa1b-4166-4950-9348-2700badd46b8.html Tender Notice 0 KB
10TenderDocuments.pdf Tender Document 0 KB
BOQ_728977.xls Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

Name of Work:Day to day complaints of internal electric supply and allied works at Tibri Mil Stn under GE Gurdaspur.
Sl. No. Item Description
1Attending of day to day electrical complaints pertaining to internalelectrification received through telephone/ Armaan or in person on detailment at MES Service centre located at NAMS Areaby locating and rectification of fault from and including electric meter/DB onwards in respect of sub main/point wiring including provisioning of small pieces of electric cable of size 1.5/2.5 Sqmm to 10 Sqmm single core copper conductor and length not increasing 0.50 mtrs and fixtures for power and light socket/light, fan and bell etc complete and carrying out repairs to the extent of tightening of loose connections, disconnection anddismantling of faulty wires, battens, conduits, boxes, main switches, MCB"s, DB"s and other E/M fixturesincluding providing necessary screws / nuts / bolts / nailsfor the rectification of defect and refixing of existing dismantled serviceable items and replacement of defective items with new ones complete all as specified and directed. Note - (i) Cost of labour for the fixing/replacement of unserviceable item shall deemed to be included in item no 2 and cost of store replaced shall be measured as supply only against relevant Items.
2(ii) Complaint pertaining to location and rectification of fault in more than one length of point wiring/sub main wiring/DB"s/fitting or fixtures etc shall be considered as an independent complaint. Similarly complaint pertaining to replacement oftwo fixtures in one Qtr will also be measured and paid as one complaint. (iii) Replacement of more than two fixtures/itemsbut multipleof three fixtures or part thereof in one Qtr/Bldg will be measured as an additional complaint. (iv) In case a Qtr/room is found locked when tradesman is detailed to attend the complaint, the complaint shall be treated as one till its completion. (v) Necessary tools for tradesman shall be provided by the contractor. (vi) Transportation for tradesman and normal stores required for complaints shall be arranged by the contractor. (vii) Complaints of normal nature shall be attended and rectified within 8Hrs of receipt of complaint. However, complaints of emergent naturei.e no light, short circuit, earth fault etc shall be attended immediately onreceipt of complaint round the clock. (viii) Bldgs requiring rewiring of small qty of point wiring if ordered will be measured and paid separately under respective items below
3(viii) Bldgs requiring rewiring of small qty of point wiring if ordered will be measured and paid separately under respective items below (ix) Requiring stores i.e switchs and sockets, fan regulator, bell push, metal flush box, lamp holder, bell ding dong of modular and non modular shall be issued by department for fixing only. (x) Contractor will deposit all the items to EM Store in advance and unsv items will be collected by the contractor as schedule of credit (xi) Electrician will report to AGE EM complaint cell at 9 O"Clock daily for collecting of complaints. Complaint received on Armaan application will be done in the same day and after completion of complaint Electrician will report to Armaan Cell for uploading the completion report. (xii) Contractor deploy local electrician for the job so that urgent nature of complaintlike no light, short circuit and earth fault will also done on Holidays/ Sunday.
4Supply only in replacement switch piano flush type 5 AmpsOne-way, AC 230V on existing switch board all as specified and as directed.
5Supply only in replacement of switch piano flush type15 Amps single pole one-way,230V complete all as specified and as directed.
6Supply only in replacementswitch piano type two ways AC 230 volts6 Ampsas per on existing switch board .
7Supply onlyin replacement socket out let 2-in-1,3 Pin 6 Amps flush type 230 volts complete all as specified and as directed.
8Supply onlyin replacement socket outlet, flush type, 2-in-1, 3 pins, 6 & 16 Amps multipurpose complete all as specified and as directed.
9Supply only in replacementbell push switch piano, flush type, 5 Amps complete all as specified and as directed.
10Supply only in replacement of bell ding-dong230 volts, single phase complete all as specified and as directed.
11Supply only in replacement of ceiling rose 65x50mm two to three terminals AC 230 volts complete all as specified and directed of any make/model as per in existing building.
12Supply only in replacementbatten type angular/ Batten lamp holder insulated body with back plate suitable for batten fitting including PVC round block complete all as specifed and as directed.
13S&Fin replacement MCBs single pole (SP) 6 to 32 Amps with 10 KA breaking capacity of "B" series in distribution boards all as specified.
14S&F in replacementMCBs single pole and neutral (SPN) 32 Amps with 10 KA breaking capacity of "B" series in distribution boards all as specified and directed.
15S&F in replacementMCBs single pole and neutral (SPN) 40 to 63 Amps with 10 KA breaking capacity of "B" series in distribution boards all as specified and directed.
16Supply only in replacement of single pole and neutral sheet metal enclosures with two pin & earth plug and socket complete with one single pole MCB of 20 Amps complete all as specified and as directed.
17Supply onlyin replacement plug top 3 pin, 5 Ampscomplete all as specified and as directed.
18Supply only in replacement plug top 3 pin, 15 Ampscomplete all as specified and as directed.
19S&F in replacement LED Tube rod with polycarbonate diffuser4 feet long of capacity 20 watts complete with all accessories baseall as specified & directed by Engr-in-Charge.
20S & F inreplacement LEDtube light fitting. ,1 x 20 W, 230 V Energy efficient T8, Box type made of CRCA shee heavy duty industrial type housing with reflector cover channel, bipin holders, connector block, etc. complete with tube rod LED 20 watt, all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size.
21Supply and fixing LED mirror light fitting batten type with high output diffuser 2 feet, 9/10 watt 230 V AC decorative type including connecting up with twin core flexible copper conductor cable of suitable size complte.
22Supply only in replacement ofLED 12 WattSquare shapesurface mounted LED Paneldown lightercomplete all as specified and directed,
23Supplying only in replacementLEDbulk head light fittings including led lamp 10 wattas per IP65 and making necessary connections complete all as specified
24Supply onlyin replacement LED slim panel cygnus series recess/surface/suspended mounting LED slim ceiling light 2"x2" with extruded aluminium housing and milky diffuser, suitable for recess mounted size 595x595mm complete with LED tube.
25Supply only in replacement of6 WattRound recess mounteddown lighter separate replaceable electronic driver celling cut out dia as per existing shaped polycarbonate fixturecomplete all as specified and directed,
26Supply only in replacement of12 Watt Round recess mounteddown lighter separate replaceable electronic driver celling cut out dia as per existing size roundshaped polycarbonate fixturecomplete all as specified and directed,
27Supply only in replacement of 15 WattSquare/round recess mounteddown lighter separate replaceable electronic driver celling cut out as per existingsquare shaped polycarbonate fixturecomplete all as specified and directed,
28Supply only in replacement of18 watt Square recess mounteddown lighter separate replaceable electronic driver celling cut out dia as per exising size/round square shaped polycarbonate fixturecomplete all as specified and directed,
29Supply only in replacemntbox type PVC rectangular block for mounting switches, sockets, fan regulator etc 4 / 6 way, surface mounting including necessary gitti for fixingcomplete all as specified and as directed.
30Supply only in replacement of frame plate with cover for modular switch 4/6 module includingscrews and washers etc model/make as per existingin site complete all as specified and as directed.
31Supply only in replacement of frame plate with coverfor modular switch 8 module includingscrews and washers etc model/make as per existingin site complete all as specified and as directed.
32Supply only in replacementceiling fan regulator, electronicSocket type, single phase, 230 volts complete all as specified and as directed.
33Supply only in replacementceiling fan regulator, electronicswitch type, single phase, 230 volts complete all as specified and as directed.
34Supply only in replacement MS machine screw 25 mm longsuitable forfixingbakelitehylam sheets / square blocks complete all as specified and directed.
35Supply onlyin replacementMS Housing box 5 / 6 module suitable formodular switch as per existing including taking out old UNSVswitch boxand making good to the disturb surfaceby pcccomplete all as specified and as directed.
36Supply only in replacement ofMCCB 100 amps 4 pole, AC 415 volts 16 KA, four pole including making connections with suitable size of aluminium lugs of any make /Model as per Existing MCCB Fitted in DB. all as specified.
37Supply only in replacement of modular switch6 Amps one module230 volts AC as per existing model/make complete all as specified and as directed
38Supply only in replacement of modular switch16 Amps one module230 volts AC as per existing model/make complete all as specified and as directed.
39Supply only in replacement of modular socket, 5/6A -2/3 pin combined 2 module,230 volts AC as per existing model/make complete all as specified and as directed.
40Supply only in replacement of modular socket, 15/16A -2/3 pin combined 2 module,230 volts AC as per existing model/make complete all as specified and as directed .
41Supply only inreplacement of capacitor AC 230 volts 2.50 MFD
42Supply only inreplacement of capacitor AC 230 volts 3.15 MFD
43Supply only in replacement of 3 mm thick hylam sheet of any sizeincludingscrews and washers etc as per required at site complete all as specified and as directed.
44Supply only in replacementmoduler bell push6/10 Amp complete all as specified and as directed.
45S & F ( in repacement) PVC round fan cover plate of size 6" to 8" or as per exiting size complete all as specified and directed.
46S & F ( in repacement) casing caping of existing size as per site including laying of electric wire inside, making electric connection and fixing necessary saddle and gitti at regular interval complete all as specified and directed.
47Supply only in replacementof single corewire 2.5 Sqmm multi-strand PVC insulated copper conductor FRLS cable including connections of cable with MCBs or bus bars complete all as specified and directed.
48Supply only in replacementof single corewire 1.5 Sqmm multi-strand PVC insulated copper conductor FRLS cable including connections of cable with MCBs or bus bars complete all as specified and directed.
49Material and labour for point wiring with 1.5 Sqmm multi strand pvc insulated copper conductor cable in existing concealed conduit for one light or bell point controlled by one switch including pvc insulated 1.5sqmm copper conductor continuousearth wire using existing CI/MS sunken box and connecting earth with dolly complete all as specified and directed. ( Note : Switch, socket measured as separate item )
50Description all as per item No 47.00 here in before but for one5 Amps independent board complete
51Description all as per item No 47.00 here in before but for one5 ampssocket out but on the same board complete
52Matrial and labour for point wiring with2.5 sqmm multi strand pvc insulated copper conductor cable in existingconcealed conduit for one 15 amps socket outlet independentcontrolled by one switch including pvc insulated 2.5 sqmm copper conductor continuousearth wire connecting earth with dolly complete all as specified and directed.
53Supply & fix in replacement of building security LED Light Luminaire 45 watt 6000K with .high power LED cool white,CRI 75,+/- 5% supply voltage 220/240,50 Hz, light engine driver base.pole adapter,powder coated pressure die cast aluminium with heat resistant toughened glass with lenscomplete all as specified.
54Supply and fix in repair GI pipe bracket ,made out of GI pipe 40/50mm dia light grade 1.2mtr long bend to the shape 120 degrees anglecomplete with two nos of clamps for fixing on walls complete all as specified and directed.
55Supply & fixing in replacement ofintegralpost top lantern complete with black ABC plastic spigot, spun aluminium funnel shape with clear acrylic cover light opening on canopy with baffles and accessories and suitable for LED lampcomplete all as specified and directed
56M& labour in replacelment for service wire 10 sqmm 2 core pvc insulated and pvc sheathested 1100 volts grade all as specified and directed
57M&L for taking down the existing faulty single phase tamper proof Electronic Energy meter with LCD display 230 volts 4 wire system, 10-60 amps, 50 Hz ,replacing the unserviceable chip board, unsv body and all burnt parts complete,making it to serviceable state, including testing, caliberation & refixing the same complete all as specified and directed by Engr-in-Charge.
58S & F inreplacement LEDtube light fitting. ,1 x 20 W, 230 V Energy efficientslim polycarbonate Battentype type housing with reflector cover channel, omplete with tube rod LED 20 watt, all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size.
59Note: A Schedule of Credit for old/unserviceable demolished/ dismantled items has been catered for in the tender. The Schedule of Credit is pre-priced by MES.The final amount of the tender shall be arrived at after deducting the total amount of Schedule of Credit from the total amount of BoQ as per General Summary sheet catered for after Schedule of Credit.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail