Tender For Augmentation Of Improvement Of Existing Water Suplly Infra At Gulmarg

Key Value

Document Fees
INR 1000 /-
EMD
INR 222000.0 /-
Tender Value
INR 1.47 Crore /-

Attachment

FileName File Description File Size
b63b4439-a5b4-4ab2-aa53-3456ad539523.html Tender Notice 0 KB
BOQ_729074.xls Tender Document 0 KB
Drgstoupload.pdf Tender Document 0 KB
tender6th.pdf Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

Name of Work: AUGMENTATION AND IMPROVEMENT OF EXISTING WATER SUPPLY INFRA AT GULMARG
Sl. No. Item Description
1Note: (i) Please refer Schedule "A" Notes of tender documents. (ii) Unless otherwise specified, earth work and excavation shall be measured and paid separately. (iii)The Schedule "A" Part-XIII (Sr No. 3 to 8) is not estimatedby MES and the estimated rate indicated as "Rs. 0.00" under Col.5 signifies this fact only. (iv) In case rate of any item is not quoted by the bidderthe rate for the same item will be considered as zero and no claim in this regard at later date will be entertained.
2LUMPSUM/ OTHER PRE-PRICED PROVISIONAL SCHEDULES OF WORKS
3Lump sum price worked out by the contractor for BUILDING WORKS as listed in Schedule "A" Part-I brought forward from serial page No. 24
4Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATION WORKS as listed in Schedule "A" Part-II brought forward from serial page No. 26
5Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY WORKS as listed in Schedule "A" Part-III brought forward from serial page No. 27
6Lump sum price worked out by the contractor for SEWAGE DISPOSAL WORKS listed in Schedule "A" Part-IV brought forward from serial page No. 29
7Lump sum price worked out by the contractor for ROAD, PATH & CULVERT WORKS as listed in Schedule "A" Part-V brought forward from serial page No. 30
8Lump sum price worked out by the contractor for FENCINGAND GATE WORKS as listed in Schedule "A" Part-VI brought forward from serial page No. 32
9Lump sum price worked out by the contractor for BORE WELL AND EXTERNAL WATER SUPPLY WORKS as listed in Schedule "A" Part-VII brought forward from serial page No. 35
10Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATION WORKS as listed in Schedule "A" Part-VIII brought forward from serial page No. 39
11Lump sum price worked out by the contractor for SITE CLEARANCE & EARTH WORKS as listed in Schedule "A" Part-IX brought forward from serial page No. 40
12Lump sum price worked out by the contractor for AREA DRAINAGE WORKS as listed in Schedule "A" Part-X brought forward from serial page No. 42
13Lump sum price worked out by the contractor for DISMANTLING / DEMOLITION WORKS as listed in Schedule "A" Part-XI brought forward from serial page No. 43
14"Miscellaneous Items of Works " (SCHEDULE "A" PART-XIII) (A) INTERNAL ELECTRIFICATION WORKS
15Supply and fixing LED tube light fitting, 4 feet long, 20 watt 220 V AC, energy effiecient, box typewith driver, holder including LED tube light,connecting up with and including three core flexible copper conductor cable of suitable size from ceiling rose including hanging bychain or hook fitted on two round blocks /fixing arrangement on truss/roof/wallcomplete all as specified and directed.
16Supply and fixing LED light fitting,45 watt LED lighting luminaiires, 220 V AC, black/grey stove enamelled finish sheet aluminium housing with sheet steel reflector cover, pre-wired mounted on & includingincl bracket made out of GI light grade pipe of 25 mm dia 1.5 mtr long bent to an angle of 120 degree fixed with 02 Nos MS clamp 40mm x 6mm and 04 sets of nuts, bolts and washers,connecting up with and including three core flexible copper conductor cable of suitable size from ceiling rose including fixing arrangement complete all as specified and directed.
17Supply and fixing MCB single pole, 6 - 32 Amp 240 Volt, 50Hz , AC, made from moulded self-extinguishing thermostat plastic and suitable for "C" Curve, 10 KA, breaking capacity and terminal box suitable upto 16 sqmm cable confirming toIS/IEC 60898-I & IS/IEC 60947-2 complete all as specified and directed..
18Supply and fixing MCB SPN, 6 - 32 Amp 240 Volt, 50Hz , AC, made from moulded self-extinguishing thermostat plastic and suitable for "C" Curve, 10 KA, breaking capacity and terminal box suitable upto 16 sqmm cable confirming toIS/IEC 60898-I & IS/IEC 60947-2 complete all as specified and directed..
19Supply and fixing exhaust fan heavy duty, 250 mm sweep, 1200 RPM, 36 Watt, steel body with blades, frame and louvers, AC supply, single phase 220 volts 50Hz, including nuts and bolts grouted in PCC, connecting up with and including three core flexible copper conductor cable 1.5 sqmm 3 core through flexible conduit from ceiling rose complete all as specified and directed.
20(B) SEWAGE DISPOSAL WORKS
21Material and labour for Elastic BiodigestorLLDPE commercial grade Septic tank for 10 users, designed to carry sewage and sludge water including excavation & earth work in any type of soil, 150mm thick PCC 1:4:8 in foundation, vent shaft, connection complete all as specified and directed.
22M&L for construction of Soakage well 1.80m dia and 3.00m deep (Depth 3.00m from inlet pipe and 45cm from Ground level to inlet pipe) including excavation & earth workin any type of soil, foundation in PCC 1:4:8 type D-2 using graded store aggregates, brick work (honey combed) in cement mortar (1:4),top ring of M-30 Design mix concrete including intercepting chamber and screen chamber made of Brick masonary in cement mortar 1:4, RCC M-30 Design mix cover slab, reinforced with TMT bars, steel plate manhole cover factory made ISI marked conforming to IS-12592 with angle iron frame, brick bats filling, complete all as specified and shown on drawing No. CESZ/TD-1078/2011.
23(C) BORE WELL AND EXTERNAL WATER SUPPLY WORKS
24Material and labour for trail drilling bore holein alluvial strata for construction of deep borewell of 200mm dia with any method as forward rotary/reverse rotary/Odex/DTH rig drilling machine complete with driling bits, dril shaft and all other accessories, complete with transportation, errection of camp at site and removal of all tools and plants on completion of borewell work for the depth upto 60 metre from ground level as complete all as specified and directed.
25All as per item No. 5.01 here-in-before but depth exceeding 60 metre and not exceeding 120 metre below ground level
26All as per item No. 5.01 here-in-before but depth exceeding 120 metre and not exceeding 150 metre below ground level Note for Item No 5.01 to 5.03:- (i) Two Nos. trial bores shall be carried out. If possibility of water is seen then the bore will resume. (ii) The cost of necessary fuel, lubricant and chemical extra required for construction of work shall be deemed to be included in the unitrate quoted by the tenderer and nothing extra shall be paid for these items. (iii). The Contractor shall execute the borewell work first. Only after successful development of Borewell, execution of rest of the work as per BOQ shall be undertaken complete all as directed.
27(iv).(a)In case of sufficient yield and potable water quality : (i) 1st trial borewill be developed as per the BOQ. (b) In case of insufficient yield or non-potable water quality (i) 1st trial bore will be abandoned. (ii) 2nd trial borewill be carried out by the contractor in the locations as earmarked by Engr-in-Charge. (v). Contractor will carry out the 2nd trial bore in condition of 2 (b) above:   (a) In case of sufficient yield and potable water quality (i) 2nd trial borewill be developed as per the BOQ. (b)In case of insufficient yield or non-potable water quality (i) 2nd trial bore will be developed as per the BOQ & water will be used for other purpose.   (c)Incase of no yield (i) 2nd trial borewill be abandoned (ii) No further trial bore will be carried out. (iii) Contractor will be paid for Item No 5.01 to 5.03 of BOQ & the contract will be FORECLOSED.
28Material and labour for development of bore by reaming upto 550mm into borewell for casing pipe of 250mm dia, for depth upto 60metre from ground level complete all as specified and directed.
29Material and labour for development of bore by reaming upto 550mm for borewell for casing pipe of 250mm dia,for depth exceeding 60metre but not exceeding 120 metre from ground level complete all as specified and directed.
30Material and labour for development of bore by reaming upto 550mm for borewell for casing pipe of 250mm dia, for depth exceeding 120metre but not exceeding 150 metre from ground level complete all as specified and directed.
31Supplying, assembling, lowering and fixing in position 250mm nominal bore MS ERW ISI marked casing blank pipe having wall thickness 8mm as per IS -4270 (2001) and jointing with electric arc welding, random length of pipe 3 to 6 metre, including necessary fittings, ie. 200mm long MS sleeves of suitable size, coupling, jointing and painting with two coats of bituminous paint of external surfaces of pipe upto depth of 60 metre below ground level complete all as specified and directed.
32Supplying, assembling, lowering and fixing in position 200mm nominal bore MS ERW ISI marked casing blank pipe having wall thickness 8mm as per IS -4270 (2001) and jointing with electric arc welding,random length of pipe 3 to 6 metre, including necessary fittings, ie. 200mm long MS sleeves of suitable size, coupling, jointing and painting with two coats of bituminous paint of external surfaces of pipe upto depth from 60 metreto 120 metre depth below ground level complete all as specified and directed.
33Supplying, assembling, lowering and fixing in position 200mm nominal bore MS ERW ISI marked casing blank slotted pipe strainer having wall thickness 8mm as per IS -8110(2000) and jointing with electric arc welding,random length of pipe 3 to 6 metre, including necessary fittings, ie. 200mm long MS sleeves of suitable size, coupling, jointing and painting with two coats of bituminous paint of external surfaces of pipe upto depth from 120 metreto 150 metre depth below ground level complete all as specified and directed.
34Material and labour for electric logging of bore well for designing and lowering of pipe assembly based on logging report/graph complete all as specified and directed.
35Material and labour for reducing socket made out of MS plate 12mm thick, size 250/200mm bore MS pipe incld jointing with electric arc welding complete all as specified and directed.
36Material and labour for bail plug made out of MS housing pipe 200mm dia, wall thickness 8mm, one and half metre long blocked with 10mm thick MS plate with bottom hook including jointing with electric arc weldingcomplete all as specified and directed.
37Material and labour for centre guide made of MS flat iron (40x6mm) iat an interval of every six metre for 250/200mm bore pipencld jointing with electric arc welding with casing complete all as specified and directed.
38Supply and filling of cleaned and washed pea gravel of size 3mm to 6mm, packing around the pipe, bottom to ground level complete all as specified and directed.
39Material and labour for MS clamp suitable for 200/250mm dia housing pipe made for 150 x 20mm thick plate including bolts/nuts and washers of required size complete all as specified and directed.
40Material and labour for MS sleeve, 10mm thick for 200mm dia MS pipe, jointed by arc welding, width 200mm, complete all as specified and directed.
41Material and labour for MS sleeve, 10mm thick for 250mm dia MS pipe, jointed by arc welding, width 200mm, complete all as specified and directed.
42Material and labour for well cap made out of 6mm thick MS plate suitable for 250mm housing pipe to provide cover at top of borewell complete with locking arrangement using 25mm dia, 400mm long MS bolt slotted through the cap and casing pipe with and including 1 No lock complete all as specified and directed.
43Material and labour for strata sample box with glass cover 3mm thick and having minimum internal dimension 1000mm x 1000mm x 100mm made out of Shisham 1st class hard wood planks, 20mm thick with hinges staple including painting two coats of synthetic enamel paint over a coat of primer complete with soil sample placed in position of 200mm wide made with wood planks 20mm thick complete all as specified and directed. NOTE: - The number of poriton may vary with type of soil starata met and overall length of the bore and can be increased beyond 1000mm x 1000mm .
44Material and labour for foundation for holding borewell assembly of size 1.00m x 1.00m x 1.00m at ground level made of PCC 1:2:4 type B-2 using 40mm graded crushed stone aggregate with GI pipe 80mm bore medium grade at three places, embedded through out the block 1.70metre length for feeding gravels and GI plug and socket fixed on top complete all as specified and directed.
45Material and labour for development of bore with air compressor not less than 400 PSI compressor over pumping unit till sand free water obtained and testing the yeild for duration as under complete all as specified and directed for first 24 hours by using air compressor complete all as specified and directed. NOTES: - (a) Contractor has to provide own DG Set/Prime mover to run compressor and over pumping set. (b) All type of T&P and transportation required for development of bore shall be arranged by the contractor and cost thereof shall be deemed to be included in the unit quoted rate.
46All as per item No. 5.21 here-in-before but subsequent48 hours after first 24 hours for over pumping.
47Material and labour for yeild test for the borewell by continously pumpingfor 16 hours to determine safe puping yield using "V" notch constructed at site complete all as specified and directed. NOTE: - Chemical/bacteriological analysis and potability test of water obtained from borewell shall be done from approved lab and submitting the report in triplicate shall be deemed to be included in the unit quoted rate. Test shall be carried out in the presence of IEM as detailed by Accepting Officer.
48Material and labour for tripod made out of heavy duty jointless GI pipe 80mm bore suitable for 2 ton capacity with nut and bolt and hook for suitable size, height of tripod should be suitable for 3m column pipe, complete all as specified and directed.
49Supply and fixing chain pulley block 2 ton capacity with heavy duty chain suitable for working 3metre abvoe ground level, chain 10metre long complete all as specified and directed.
50Supply, installation, testing and commissioning of submersible pump 12.5 HP electric driven, 415V, TP suitable for GI pipe 100mm dia, discharge capacity 240 LPM, Head 130metre including suitable size of flexible steel rope for holding submersible motor pump complete all as specified and directed.
51Supply, installation, testing and commissioning of chemical dosing system suitable to inject solution upto 25LPH comprising dosing pump coupled with single phase electric motor of capacity 0.5HP, 1440 RPM assembly including DOL starter suitable capacity with agitator dosing and agitator in single motor, agitator with SS sweep blade duly FRP coated, FRP double tank 150 litre capacity, complete unit mounted on heavy duty MS fabricated frame duly painted with anti corrosive paint including packing, electrical & pumping works etc. complete all as specified and directed. NOTE: - The cost of electrical connection like point wiring and socket point requreid for smooth functioning of dosing plant and T&P shall be included in the unit quoted rate.
52Supply and fixing UPVC pipe of 20mm dia confirming to IS 4985/2000 complete including necessary clamps and fittings, jointing material etc. complete all as specified and directed.
53Supply and lowereing in borewell, MS ERW column pipe of size 100mm bore confirming to IS-1239, in 3metre length, both ends flanged with 10mm thick MS flange including cutting holes (04 Nos) of size 10mm dia for passing the submersible cable, with and including suitable size of covering nuts, bolts, washers and rubber gasket complete all as specified and directed. Note: - All arrangements and T&P requried for lowering the column pipe in the bore shall be made by the contractor under their own arrangement at no extra cost.
54Supply & fixing Cast Iron Air Valves with two air Outlets, 100 mm dia bore confirming to IS 14845:2000 and fixing Up in cast iron water supply mains complete all as specified and directed.
55Supplying, laying and testing, centrifugally cast (spun) Ductile Iron pressure pipeincl fittings ie bends, tee etc with spigot and socket endsof100 mm bore, confirming to IS 8329:2000and of any length of class K-7, suitable for rubber tyton joint, surface finished with zinc bitumen coating complete all as specified and directed. NOTE:- (a) Pipes shall be laid in trenches/over RCC pillars/under bridges/culverts/roads etc. as directed. Contractor shall have no claim on this account. (b) Bends, tees and all other DI fittings of any length as required and Joints with jointing material / Earth work / PCC shall be measured and paid separately.
56Material and labour for tyton joint suitable for 100mm bore DI pipe including jointing material complete all as specified and directed.
57Material and labour for Ductile iron Bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch. "Y" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs complete all as specified and directed.
58Material and labour for construction of brick valve pit of size 0.90mx0.90mx1.50m (internal dimensions) including all excavation and earth work in any type of soil, returning filling in and disposal of surplus soil to a distance not exceeding 50m and depositing where directed, PCC 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in foundation, PCC 1:2:4 type B-2 using 12.5mm graded crushed stone aggregateas in coping inincl necessary form work, brick masonary in cement mortar 1:4 using sub class "B" old size bricks, rendering 12mm thick in cement mortar 1:4 even and fair to internal surfaces and flush pointingto external wall with same mortar as the work proceed, valve pit cover ofMS sheet cover 3.15mm thick welded to mild steel angle iron 50mmx50mmx6mm frame with handle and locking arrangement, painting all the exposed surfaces of steel with two coats of synthetic enamel paint over a coat of primer and the portion embedded in concrete with two coats of black bituminous paint complete all as specified and directed.
59Material and labour for construction of brick valve pit of size 0.60mx0.60mx0.60m (internal dimensions) including all excavation and earth work in any type of soil, returning filling in and disposal of surplus soil to a distance not exceeding 50m and depositing where directed, PCC 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in foundation, PCC 1:2:4 type B-2 using 12.5mm graded crushed stone aggregateas in coping inincl necessary form work, brick masonary in cement mortar 1:4 using sub class "B" old size bricks, rendering 12mm thick in cement mortar 1:4 even and fair to internal surfaces and flush pointingto external wall with same mortar as the work proceed, valve pit cover ofMS sheet cover 3.15mm thick welded to mild steel angle iron 50mmx50mmx6mm frame with handle and locking arrangement, painting all the exposed surfaces of steel with two coats of synthetic enamel paint over a coat of primer and the portion embedded in concrete with two coats of black bituminous paint complete all as specified and directed.
60Supply, laying and testing submersible cable with copper conductor of size 25qmm, 3 core for submersible pumping set complete all as specified and directed.
61(D) EXTERNAL ELECTRIFICATION WORKS
62Supply, instalation, testing and commissioning of ECO friendly Diesel Engine driven generating set of 25KVA, outdoor type, Derated Engine, HP not less than 45HP, CPCB-II nearest higher side 400/440 volt, AC, 50 Hz, 4 wire, 0.8PF, suitable for work between -23ºC to +30ºC, directly coulpled alternator and engine, water cooled with AMF Panel common steel base fixed on cement concrete in foundation as per OEM recommendation. DG set of 25 KVA platform with inbuilt AMF panel with 02 Nos suitable size contactors (01 No. for main supply and 01 No. for DG supply) as per manufacturer recommendation and other accessories comprising of following: - (A) ENGINE: ECO friendly for emission and noise (PCB NORM COMPLIANCE) 4 stoke diesel engine confimring to BS standard developing 1500RPM, turbocharged water cooled complete with a provision for 10% over laod for one hour on 25VA comprising of following:- (i) Fly wheel with starter ring for generating set. (ii)Dry type Air filter (iii) Lub oil cooler assembly with accessories. (iv) Exhaust air manifold (v)Exhaust silencer.
63(vi) Expansion below. (vii)Exhaust gas turbocharger. (viii) Fuel filter (pre micro) (ix) Lubrication oil filter (x)12V electrical starting system with starting motor & battery charging alternator with self starter and other auto electric accessories as recomanded by manufacturer. (xi)Centrifugal by-pass filter (xii)Front & rear enginer mountin supports. (xiii) Engine control panel consisting of OFF/ON/START keys lub oil pressure gauge,Ammeter, electroinc Hour meter, speedometer. (xiv) Safety against low ub oil pressure. (xv)Enginer operation/maintenance, spare parts manual. (xvi) Engine test certificate (xvii)Cold starting kit (xviii)MS frame suitable for mounting of Engine & alternator. (xix) Fuel tank of suitable capacity as per manufacturer recommendation completewith fuel gauge inlet/outlet connections drain valve with plug etc. (xx) Battery of suitablke capacity as epr anufacturer recommendation with copper leads and terminals of suitable size. (xxi)One set of AVM pads fitted on base frame
64(B) ALTERNATOR: Sailent pole brushless type suitable for direct couple to engine self excited, self regulated with fast response, thyristor type, electroic automtic voltage withhold, output voltage with in desired limit (+1%), Dynamically balanced 400/415 volt, AC, 3 phase, 50 Hz, 4 wire, 0.8PF lagging 25KVA, 1500 RPM star connected (4 wire) screen protected, drip proof enclousers with radial fan mounted on rotor with insulation class-F/H and with stand an over load of 10% for one hour in every 12 hour operation ambient temperature varies from -23ºC in winter to +35ºC in summer with following accessories. (C) ACOUSTIC ENCLOSURE: Supply & installation of acoustic enclosure suitable for 25KVA DG Set shall be as under; - (i) Fabricated out of CRCA sheet of suitable thickness as per manufacturer design,polyster based powder coated internaly and externaly with lockable type door handle. All nuts and handles shall be zinc coated. (ii) The doors are gasketed with EPDM gaskets. (iii) Sound proofing with high quality rock wool/mineral confirming to IS 8183 of 50mmthickness and density at 96kg/Cum covered with fiber glass cloth and perforated powder coats sheet specialy designed alternators (sound controllers) at air entry and exit of the container, noice level shall not exceed 75Db at 1 metre distance as per CPCB norms.
65(iv)Adequate ventilation to meet air requirement for combustion and heat removal with provn of a blower. (v) Emergency stop push button out side the container. (vi)Provn of light inside the canopy 20W LED fittings with wiring and control switches. Notes:- (i) DG set shall be designedconsidering the derated factor of altitude 9000 ft above sea level, extreme cold climate and heavy snow fall in winters. The ambient temp varies from-23ºC (in winter) to +30ºC (in summer). (ii) After considering derating factor by manufacturer on above location, the required net output of DG Set shall be 25 KVA. (iii) Testing of DG Set shall be carried out in the presence of IEM (Rep of Accepting Officer).
66Material and labour for construction of covered platform for single transformer of size 3.50m x 2.50 m x 1.20 m high from natural ground level with brick walling including steps, XPM fencing fixed with MS angle iron fencing posts upto 2.45 metre height above ground level with MS gate and locking arrangement incld necessary earthwork and excavation having following specifications:- (a)Foundation in PCC (1:4:8) type D-2 (using 40 mm graded crushed stone aggregate) (b) Brick work in CM 1:4 having wall thickness not less than 230mm using old size sub class "B" bricks (c) Filling under floors of approved rammed earth. (d) 100 mm thick PCC (1:5:10) type E-2 (using 40 mm graded crushed stone aggregate) in sub base (e) 50mm thick PCC flooringPCC (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) finished even and smooth with using extra cement. (f) 10 mm thick cement plaster in CM 1:6 on walls finshed fair and even without using extra cement. (g) 2 coats of cement base paint on plastered surfaces. (h) 2 coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces. (j) Excavation and earth work in any type of soil including removal of surplus soil to a distance not exe 50 mtr. Note:-All details shall be as shown in Drg No. CESZ/TD-1110/2011 sh 1/2 & 2/2 except size.
67Supply and erecting Steel tubular swaged pole complete with MS base plate continuously welded to pole, finial taper plug, bolts, nuts & screws as specified type 410 SP- 55 (11 metres long) including two coat of black bituminous paint internally throughout and externally upto embedded portion and including applying two coats of synthetic enamel paint over a coat of red oxide primer with black and yellow strip of 30 cm each upto 1.5 m height and two coats of aluminium paint over a coat of red oxide primer externally on remaining exposed surface after errection in position includingpreparation of surface, complete all as specified and directed. Note:- Necessary earth work, PCCcoping will be measured and paid for separately under respective item.
68Supply and erecting Steel tubular swaged pole complete with MS base plate continuously welded to pole, finial taper plug, bolts, nuts & screws as specified type 410 SP- 22 (8.5 metres long) including two coat of black bituminous paint internally throughout and externally upto embedded portion and including applying two coats of synthetic enamel paint over a coat of red oxide primer with black and yellow strip of 30 cm each upto 1.5 m height and two coats of aluminium paint over a coat of red oxide primer externally on remaining exposed surface after errection in position includingpreparation of surface, complete all as specified and directed. Note:- Necessary earth work, PCC coping will be measured and paid for separately under respective item.
69Material & labour forswitch air break gang operated out door HT 11 KV triple pole mechanically operated mounted on HT insulators (12 Nos insulators) of rating upto 200 Amp and MS galvanised steel frame with operating mechanism worked fromground level including operating rodof GI pipe of 25 mm bore with handle for current rating 200 Amps, 11000 voltsincluding suitable DO Fuse complete with locking arrangements MS clamps, bolts, nuts and washers etc. includingfuse barrels of required capacity to suite the load at site including two coats of aluminium paint over a coat of red oxide primer on MS work complete all as specified and directed.
70Supply, install and commissioning Servo controlled oil cooled voltage stabilizer 20 KVA for automatic operation, IS 9815 Part-1 : 1994, Reaffirmed : 2014, three phase output, 50 Hz, naturally oil cooled, indoor type & with following specifications:- Winding Material pure Electrolyte copper Supper Enamel/Glass Coated/DCC, Wire strip. No load Loss: 0.40% On load Loss : Less than 2.5% Load type :Suitable for Unbalanced voltage and unbalanced load Winding : Copper Wound (Dimmer & Transformers) Input voltage range 3Ø:270V to 480V Output voltage 3Ø :415V + 1% adjustable Response time: Less than 10 msec Efficiency : More than 95% Rate of correction (Phase & Neutral) : More than 8 V/sec in single phase 12V/sec in three phase Wave from distortion : Nil Environment/Installation Type : Indoor Type (IP 32 CPRI Certification) Duty cycle : 24x7 continuous Control: Auto/Manual Protection Indications:- Trip/MCCB overload & short circuit protection High/ Low voltage protection Single phase Sequence Change Single phase prevention system Over Temperature cut off Spike & Surge protection - Type-II
71Bye Pass Arrangement : Bye Pass arrangement (for in case of Emergency) Indicator Input/Output Voltage (per Phase). Output Current (Per Phase). Frequency. Fittings-Four Plain Rollers. Two Earthing Terminals. Four Lifing Hooks . Oil filling hole with cap. Oil levl indicator. Sailent Features Motor Varieable speed High Torque AC servo motor with proporation control DG Compatible -Special sensing circut to maintain output voltage Auto/Mannual control facility on front control plate in unlikely events. Construction : Rugged construction with caster wheels for easy movement. Trasformer and variac -Wound with Electrolyte grade copper of 99% purity low loss CRGO sheets. Earthing : Suitable Earthing terminal to be provided. Suitability:All power factor loads Mounting: Preferably on Wheels Indication:1.LED for input on (Yellow) 2. LED for output healthy (Green) 3. LED for output Trip (Red)
72Supply and fixing LED street light fitting 35 Watt, 230 volt, AC outdoor type, with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics with IP 65/66 protection complete incl bracket made out of GI light grade pipe of 32 mm dia 1.5 mtr long bent to an angle of 120 degree fixed with 02 Nos MS clamp 25mm x 4mm and 04 sets of nuts, bolts and washerscomplete all as specified and directed.
73M & L for sand cushioning with a layer of fine sand 8 cm thick before laying of cable and 15 cm thick after laying of cable in trenches complete all as specified and directed. Note:-Measurement shall be taken only after punning down sand cushioning.
74Supply and laying in trenches sub class "B" bricks, old size, laid dry flat on sand cushioning for protection of cable abutted each other complete all as specified and directed. Note:Sand cushioning shall be measured and paid for separately..
75Supply, installation, testing and commissioning of LT Panel board suitable for 415 Volts, 3 Phase 4 wire, 50 Hz AC supply system confirming to IS:8623/93, CPRI approved, outdoor type floor mounted alongwith factory made type panel weather proof, vermin proof, fully ventilated and fabricated out of MS CRCA sheet of 3.15mm thick with ingress protection of IP-54 grade having heat shrinkable sleeves, louvers and air vent gasket for natural flow of air “U” type gasket shall be used to make the outer shell completely vermin proof.The panel shall be cubical type with Sloppy roof, openable in front & rear and having inner & outer shells, Aluminium bus bar of capacity 200 Amp rated.The inner shell dully compartmented for each control gear, including powder coating synthetic enamel paint over a coat of red oxide primer internally and externally the entire steel surfaces. All the cover shall be provided with suitable locking arrangements mounted on angle iron stand made out of MS angle size 50mmx 50mm x 6mm grouted in PCC foundation in cement concrete 1:3:6 type C-1 platform 60 cm above the ground level and 45 cm below the ground level (using 20mm graded crushed stone aggregate), including accomodating the following gears and accessories connected with Internal wiring of suitable size of copper conductor cable :-
76(a) Incoming MCCB 100 Amp 25 KA, 4 pole, adjustable thermal setting type- 01 No. (b)MCCB 63 Amp 16 KA, 3 pole, 415 Volt, adjustable thermal setting type = 01 No (c)MCCB 32 Amp 16 KA, 3 pole, 415 Volt, adjustable thermal setting type = 01 No (d)MCB TPN, 32/40 Amp415V, 10 KA - 01 Nos. (For chlorination) (e)Motor Starter 3 phase 50 Hz, suitable for 11 HP motor with overload protection and single phase preventor - 01 No (f) Digital voltmeter 0 to 500 Volt digital type 96mmx96mm with built in selector switch = 01 No. (g) Digital Ammeter 0 to 500 Amps digital type 96mmx96mm with CTs and built in selector switch = 01 Set (h) Indication Lamps LED Type (RYB) = 01 Set (j) Space Blank for 1 x Outgoing MCCB Note : (i)The Cost of MCCBs, MCB, Motor starter, Ammeters, Voltmeters, Bus Bar, Indication Lamps, Copper wiring, PCC, earthwork and paintwork to be included in quoted rate. (ii) LT panel drawing shall be approved by GE.
77Supply, installation, testing and commissioning of LT Panel board suitable for 415 Volts, 3 Phase 4 wire, 50 Hz AC supply system confirming to IS:8623/93, CPRI approved, outdoor type floor mounted alongwith factory made type panel weather proof, vermin proof, fully ventilated and fabricated out of MS CRCA sheet of 3.15mm thick with ingress protection of IP-54 grade having heat shrinkable sleeves, louvers and air vent gasket for natural flow of air “U” type gasket shall be used to make the outer shell completely vermin proof.The panel shall be cubical type with Sloppy roof, openable in front & rear and having inner & outer shells, Aluminium bus bar of capacity 200 Amp rated.The inner shell dully compartmented for each control gear, including powder coating synthetic enamel paint over a coat of red oxide primer internally and externally the entire steel surfaces. All the cover shall be provided with suitable locking arrangements mounted on angle iron stand made out of MS angle size 50mmx 50mm x 6mm grouted in PCC foundation in cement concrete 1:3:6 type C-1 platform 60 cm above the ground level and 45 cm below the ground level (using 20mm graded crushed stone aggregate), including accomodating 01 MCCB 63 Amp 25 KA, 4 pole, 415 Volts, adjustable thermal setting type connected with Internal wiring of suitable size of copper conductor cable.
78Supply and fix Junction Boxshock proof and rust proof rot proof and termite resistant cable entry from the bottom and or sides 100% weatherproof with pole mounting arrangement tamper proof pilferage proof restricts unauthorize tapping maintenance free fire retardant class FV-0 as per IS:11731 Part II or V-0 as per UL-94 and high heat distortion temperature (200 degree C as per IS:10192)
79Supplying and laying synthetic Rubber insulated mat,2.00m x 1.00m size, 10mm thick,for voltage upto 11 KV for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety complete all as specified and as directed.
80(E) EARTHING WORKS
81Material and labour for Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6 mm thick buried directly in gound (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground level, connected to galvanised iron earth lead 4mm dia by means of bolt, nuts check nuts and washers of galvanised iron and 4 mm dia GI earth wire protected by provn of GI lightgrade pipe 15mm bore upto 7.5mtr including provision of concrete pit in PCC (1:2:4)type B-1 (using 20 mm graded crushed stone aggregates)with 40mm thick cover ofRCC (1:2:4) reinforced with XPM (Weight not less than 4kg/Sqm) and frame of angle iron 25x 25x3mm with lugs 02 Nos and with 6 mm dia MS bar handle made to shape, GI medium grade 20 mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, test point made out of Bronze/Gun metal with fixing arrangement, funnel, wire mesh and excavation/earth work inhard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre, all as per electrical plate No 3 of SSR - 2009 Part -I and connecting to earth test point all as specified or indicated including testing on completion, complete all as specified and directed. Note : The quoted rate of earthing shall be deemed to include cost of 7.5 m long galvanised wire 4 mm dia and protection pipe 15 mm bore GI light grade, watering pipe 20 mm bore medium grade. Any variation in length shall be adjusted through deviation order based on SSR rates adjusted with quoted rates.
82M&L for earthing complete with galvanised steel earth plate of size 60cmx60cmx6mm thick, surrounded by mixture of charcoal and salt in alternate layers burried directly in ground, earth pit not less than 2.25 m deep below normal ground level with top edge of the plate not less than 1.5m below normal ground level, connected to equipment by using GI strips of size 32x6mm as earthing lead by means ofolts, nuts, checknut & washers ofgalvanised iron all as shown in elect plate No.3 of MES SSR Part-I and connected to earthing test point, common salt and charcoal filling, all as specified and directedincluding necessary excavation & earth work in any type of soil charcoal & salt in altemate layers, 20mm GI Pipe (medium grade) for watering, 40mm GI protection pipe (light grade) funnel wire mesh, lugsPCC 1:2:4 type B1 chamber in cement concrete ,50 mm thick precast RCC M-25(Design mix) cover duly reinforced with XPM (weight not less than 4 kg /sqm) & CI frame etc , provision of test point, connecting to test point and testing on completion etc, complete all as specified and directed. Note : The quoted rate of earthing shall be deemed to include cost of 7.5 m long GI earth strip 32x6mm and protection pipe 40 mm bore GI light grade, watering pipe 20 mm bore medium grade. Any variation in length shall be adjusted through deviation order based on SSR rates adjusted with quoted rates.
83Supply & laying 4mm diaGalvanised steel wire as Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as requiredcomplete all as sepcified and directed.
84(F) DEMOLITION / DISMANTLING WORKS
85Taking up or down steel tubing and connection 80mm with all fittings including removal to store complete all as specified and directed.
86Taking out old unserviceablesluice valve of any size complete all as specified and directed.