Tender For Repair Replacement Of External Electric Supply And External Water Supply Bore Well, Cleaning Of Oh Tank Connected Work Etc At Military Station Barabanki Under Ge (East) Lucknow, lucknow-Uttar Pradesh

Military Engineer Services-MES has published Tender For Repair Replacement Of External Electric Supply And External Water Supply Bore Well, Cleaning Of Oh Tank Connected Work Etc At Military Station Barabanki Under Ge (East) Lucknow. Submission Date for this Tender is 17-05-2024. Bore Well Tenders in lucknow Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

43245002
Tender For Repair Replacement Of External Electric Supply And External Water Supply Bore Well, Cleaning Of Oh Tank Connected Work Etc At Military Station Barabanki Under Ge (East) Lucknow
Open Tender
Indian
Uttar Pradesh
lucknow
17-05-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Repair Replacement Of External Electric Supply And External Water Supply Bore Well, Cleaning Of Oh Tank Connected Work Etc At Military Station Barabanki Under Ge ( East ) Lucknow

Key Value

Document Fees
INR 500 /-
EMD
INR 98000.0 /-
Tender Value
INR 49 Lakhs /-

Attachment

FileName File Description File Size
9e096a65-e0e6-4443-a9e6-6cddb7f20b9d.html Tender Notice 0 KB
BOQ_728976.xls Tender Document 0 KB
Tender02.pdf Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

Name of Work: REPAIR & REPLACEMENT OF EXTERNAL ELECTRIC SUPPLY AND EXTERNAL WATER SUPPLY, BORE WELL, CLEANING OF OH TANK CONNECTED WORK ETC AT MILITARY STATIONBARABANKI UNDERGE (EAST) LUCKNOW.
Sl. No. Item Description
1Excavation in trenches not exc 1.5 m wide and not exc 1.5m deep for laying of pipe, cable etc and getting out in soft/loose complete all as specified and directed.
2Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm thick in soft/loose soil complete all as specified and directed.
3Removing surplus excavated material to a distance not exc 50 meter and depositing where directed at level not exc 1.5m above the starting point,complete all as specified and directed.
4M&Lfor sand cushioning for protection of cables complete all as specified and directed.
5Supplying & laying common bricks sub class B for LT cable for protection of cable complete all as specified and directed.
6Boring/cutting of road for laying of pipe not exceeding 90 cm below groundlevel all complete as specified and as directed.
7S&F GI tubes light grade of size 40mm galvanised with all fittings forroad crossingincluding taking down / dismantling the old items complete all as specified and directed.
8S&F in replacement mild steel cross arms channel, bracing, support, clamps etc fabricated structured steel, sections, including nuts, bolts, washers etc and cutting to required length beat to any shape drilling holes, fixed on poles or jointed by means of elect weldingincluding taking down / dismantling the old items complete all as specified and directed.
9M&L for size 40 mm graded coarse aggregate in the station yard for laying complete all as specified and directed.
10S&F in repair danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with screws, nut bolts with adequate size clamps on HT/LT pole of 25x20 cm size complete all as specified and directed.
11M&L for PCC (1:4:8) type D-2 using 40 mm graded aggregate as in base foundation of pole concrete including providing necessary form work complete all as specified and directed.
12M&L for PCC (1:3:6) type C-2 using 40 mm graded aggregate as in foundation of pole/stay and filling of mass concrete including providing necessary form work complete all as specified and directed.
13M&L for PCC (1:2:4) type B-1 using 20 mm graded aggregate as in coping of pole including providing necessary form work complete all as specified and directed.
14M&L for removing the vegetation growth for site clearencein soft /loose soil in around HT/LT poles, around E/Minstallations complete all as specified and directed.
15Taking down the old U/S steel LT/HT poles of any height ,struts including Demolition of cement concrete,GI structure supports, stay assemlies, junction box complete all as specified and directed.
16S&F in replacement of sheet metal enclosure distribution board, vertical Tripple pole and neutral, AC, 415 volt, 04 way,bus bar and metal door with IP - 43 & IK 09 protection and flush to wall, as MCCB as in comming , and MCBs are out going ,(Measured under relevent items of schedule )including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified & directed.
17S&F in replacement of sheet metal enclosure distribution board, vertical Tripple pole and neutral, AC, 415 volt, 06 way,bus bar and metal door with IP - 43 & IK 09 protection and flush to wall, as MCCB as in comming , and MCBs are out going ,(Measured under relevent items of schedule )including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified & directed.
18S&F in replacement of MCCB, 3 pole, AC, 440 volts 160 Amps , 36 KA adjustable type complete all as specified and directed.
19S&F in replacement of MCCB, 3 pole, AC, 440 volts 200 Amps , 36 KA adjustable type complete all as specified and directed.
20S&F in replacement of MCCB, 3 pole, AC, 440 volts 400 Amps , 36 KA adjustable type complete all as specified and directed.
21Supply, laying and testing cableXLPEinsulated,screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 95 sqmm 3.5 core,including taking down / dismantling the old items complete all as specified and directed.
22Supply, laying and testing cableXLPEinsulated,screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 70 sqmm 3.5 core, including taking down / dismantling the old items complete all as specified and directed.
23Supply, laying and testing cableXLPEinsulated,screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 50 sq. mm 3.5 core,including taking down / dismantling the old items complete all as specified and directed.
24Supply, laying and testing cable HT XLPE cable , 11000 Volt, 3 Core , PVCinsulated,screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor of size 95 sq. mm 3.0 core,including taking down / dismantling the old items complete all as specified and directed.
25S&Fheat shrinkable end jointing kit for 3 ½ / 3 core XLPE HT , 11000 volt, armoured cable of size 95 sqmm including taking down / dismantling the old items complete all as specified and directed.
26S&Fheat shrinkable jointing kit for 3 ½ / 4 core XLPE, armoured cable of size 25 to 50 sqmm including taking down / dismantling the old items complete all as specified and directed.
27S&F heat shrinkable jointing kit for 3 ½ / 4 core XLPE, armoured cable of size 70 to 120 sqmm including taking down / dismantling the old items complete all as specified and directed.
28S&F terminal junction box with including nut bolts with iron clamp out door dust and vermin proof fabricate with 1.6 mm thick MS sheet encloser 200X 250X150 mm including neutral link and 4 nos 230 volts 63 amps bus bar for house connection with 2X10 SQ mm copper conductor multi standard and connecting insulator including two coats of synthetic enamel paint over a coat of metal primer including taking down / dismantling the old items complete all as specified and directed.
29Supply & Laying synthetic rubber insulated mat 2.5 mm thick for voltage up to 11 kV for eletrical purpose as per IS 15652-20026 suitable for eletrical shok safty of size 2 x 1 mtr complete all as specified and directed.
30Supply, installation, commissioning and testing of 125 KVAR automatic power factor correction (APFC) banks factory cubical compartmentalized outdoor dust vermin and weather proof made out CRCA MS sheet of minimum 3.15mm thick of appropriate size front openable, with locking arrangement supported on 50mm x 50mm x 6mm angle iron frame and 4 No legs 900mm long each duly grouted in PCC (1:2:4) each leg 50cm grouted in ground/ floor and 40cm above floor level complete duly powder coated from inside and outside with seven tank process comprising following :- (a) Copper bus bar of size 40mm x 5mm, 4 pole suitable for 600 Amp loadcapacity, duly colour coded with PVC sleeves -01 Job (b) MCCB 4 pole 560 Amp 50Hz, 415 V with adjustable thermal magnetic release and rupturing capacity 25KA - 01 No. (c) MCB ‘D’ series TP 32 Amp 10KA 415 volts -08 No. (d) MCB ‘D’ series TP 40 Amp 10KA -06 No. (e) Capacitive duty contractor (Heavy duty) cylindrical 20 KVAR -04No. (f) Capacitive duty contractor (Heavy duty) cylindrical 10 KVAR -02No. (g) Capacitive duty contractor (Heavy duty) cylindrical 5 KVAR -04 No. (h) Capacitive duty contractor (Heavy duty) cylindrical 3 KVAR -01 No.(j) Capacitive duty contractor (Heavy duty) cylindrical 2 KVAR -01 No. (h) Shunt capacitor (heavy duty cylindrical) 20 KVAR - 04 No & Shunt capacitor (heavy duty cylindrical) 10 KVAR - 02 No. (j) Shunt capacitor (heavy duty cylindrical) 5 KVAR - 04 No. (k)Shunt capacitor (heavy duty cylindrical) 3 KVAR - 01 No. (k)Shunt capacitor (heavy duty cylindrical) 2 KVAR - 01 No.(k) Microprocessor based APFC relay 8 steps -01 No.(l) RYB Phase indicator LED type protection fuses -01 Set (m) Digital voltmeter 0-500 volts of size 96mm x 96mm with in-built selector switch duly pre-wired with suitable size copper wire -01 No (q) Digital Ammeter 0-500 Amps with inbuilt selector switch with CTsduly pre-wired with copper wire -01 No.
31Supply installng, testing and commissioning floor mounted LT panel out door type of suitable size cubical type factory made, weather and vermin proof made out of CRCA sheet 3.00 mm thick appropriate size of panel 1.2 x 1.2 x 0.45 M and angle iron frame of 40x40x6mm and 04 Nos legs on angle iron 50x50x6mm each 45 cm long panel duly powder coacted in side and out side with 7 tank process heaving insulated bus bar TPN with openable shutter on both side (Front and rear side) with locking arrangement duly pre-wired with suitable size of copper conductor cable with proper size of copper lugs/thimbles and connecting to MCCBs with suitable size aluminium strip duly bended and fixed with nut & bolts and washers from bus bar to MCCBs and legs grouted in PCC 1:2:4 type B:1 (20 mm graded stone aggregate) with gland packing to provided for cable approved complete as under.
32Aluminium bus bar strip of capacity 320 amps fixed on epoxy insulator - 04 Noscomplete all as specified and directed.
33Incomming MCCB of current rating 160 Amps with adjustablethermal release 4 pole 415 volts 36 KA repturing capacity - 01 Nos. complete all as specified and directed.
34Out goingMCCB of current rating 100 Amps withadjustable thermal release 4 pole 415 volts 25 KA repturing capacity - 01 Nos. complete all as specified and directed.
35Out goingMCCB of current rating 63 Amps with adjustable thermal release 4 pole 415 volts 16 KA repturing capacity - 03Nos. complete all as specified and directed.
36Digital voltmeter (0-500 volt) 96x96mmcomplete all as specified and directed.
37Digital ampmeter (0-600 amps) 96x96mm incl with CTcomplete all as specified and directed.
38Set of phase indicator lamp R,Y,B with control MCB - 01 Setcomplete all as specified and directed.
39Supply installng, testing and commissioning floor mounted LT panel out door type of suitable size cubical type factory made, weather and vermin proof made out of CRCA sheet 3.00 mm thick appropriate size of panel 1.2 X1.2 X0.45M and04 Nos legs on angle iron 50x50x6mm each 45 cm long panel duly powder coacted in side & out sidewith 7 tank process heaving insulated bus bar TPN with openable shutter on both side (Front and rear side) with locking arrangement duly pre-wired with suitable size of copper conductor cable with proper size of copper lugs/thimbles and connecting to MCCBs with suitable size aluminium strip duly bended and fixed with nut & bolts and washers from bus bar to MCCBs and legs grouted in PCC 1:2:4 type B:1 (20 mm graded stone aggregate) with gland packing to provided for cable approved complete as under. complete all as specified and directed.
40Aluminium bus bar strip of capacity 400 amps fixed on epoxy insulator - 04 Noscomplete all as specified and directed.
41Incomming MCCB of current rating 200 Amps with adjestable thermal releasetype 4 pole 415 volts 36 KA repturing capacity - 01 Nos. complete all as specified and directed.
42Out goingMCCB of current rating 100 Amps with adjestable thermal releasetype 4 pole 415 volts 16 KA repturing capacity - 02 Nos. complete all as specified and directed.
43Out goingMCCB of current rating 63 Amps with adjestable thermal releasetype 4 pole 415 volts 16 KA repturing capacity - 02 Nos. complete all as specified and directed.
44Digital voltmeter 96x96m squire type with inbuilt selector switch -01 Noscomplete all as specified and directed.
45Digital ampmeter96x96m squire type with CTs inbuilt selector switch -01 Noscomplete all as specified and directed.
46Set of phase indicator lamp R,Y,B - 01 Setcomplete all as specified and directed.
47M&L in replacement earthing complete with galvanized steel earth plate electrode 60 cm X 60 cm X 6.0 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level connecting to the GI strip 32 x 6mm, by means nut bolt, nuts, check nuts and washer of the GI Earth wire protected by provision of GI light grade pipe 40 mm incl provision of concrete pit in PCC (1:2:4) type B-1 using 20 mm graded stone aggregated with 40 mm thick cover with RCC (1:2:4) reinforced with XPM (weight not less than 4 Kg / Sqm) and frame of angle iron 25mm X 25 mm X 3mm with lugs 2 Nos and with 6 mm dia MS bar handle made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, taste point made out of phosphorus bronze with fixing arrangement, funnel, wire mesh andearth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding than 50 mtr, all as per electric plate No 3 of SSR Part I 2009 and connection to earth test pointcomplete all as specified and directed.including testing on completion”.
48M&L Stay assembly comprising of 20 mm dia stay rod 2150 mm long, loop type insulator of size 90 mm x 140 mm, galvanised stay plate 6mm thick of size 300 mm x 300 mm, stay bow, stay clamps etc. & shown inEP No. 1 of SSR Pt I.including taking down / dismantling the old items complete all as specified and directed. Note : Excavation, earth work and PCC shall be measured and paid seperately.complete all as specified and directed.
49M&L for taking out of submersible pumpset capacity 25 HP from bore well/shallow well for repair and replacement of unserviceablecolumn pipes approx 80 to 100 mtrs using chain pully block manually and transportation of submersible pump and motor assy for necessary repair ement of wornout parts like bearing impeller bushing coupling etc and incl refixing the existing serviceable components after proper cleaning , machining as required ,assembling testing at workshop , carrying out painting bycomplete all as specified & directed.Note:- All new parts / spares /re- winding/ compenent will be measured and paid seperately under respective items
50M&L for complete overhauling of submersible pumpset of capacity 25 HP by replacement of bearings,stainer,applying quick drying warnish to starter winding,cleaning of mineral deposition and refixing Part by partby using tools and tackles and necessary GI specials,bolts nuts,as required at site, carrying out painting with 2 coat of synthetic enamelled paint over a coat of primer, refixing the existing serviceable components after proper cleaning , machining as required ,assembling testing at workshop complete all as specified & directed. Note:- (i) All new parts spares /compenent will be measured and paid seperately under respective items(ii) Replacement of bolts /nuts.washers is deemed to be included in the items. complete all as specified and directed.
51Replacement ofbrass impeller of 25 HP submercible pumpcomplete all as specified and directed.
52Replacement of Stage casing bearing of 25 HP submercible pumpcomplete all as specified and directed.
53Replacement of Shaft sleeve bush for 25 HP submercible pumpcomplete all as specified and directed.
54Replacement of Suction Gun metalbush for 25 HP submercible pumpcomplete all as specified and directed.
55Replacement of Thrust bearing complete for 25 HP submercible pumpcomplete all as specified and directed.
56Replacement of Pump shaft key for each stage submercible pumpcomplete all as specified and directed.
57M&L for rewinding of 25 HP submersible pump set motor coil with water ressistant super enameled quality copper winding wire as per existing gauge and providing insulation materials ,varnishing etcafter cutting, removing burnt out / leakage damaged coils & reassembling the motor complete as reqd complete all as specified & directed.
58S&F in repair seamless column pipeheavy duty of 80 mm bore with thickness not less than 6 mm , 8 TPI thread of 10 ft long each pipe with both end thread /flanged inbcluding joints complete all as specified & directed
59Supply and layin replacement Flat submersible cable PVC insulated weather / water proof with flexible copper conductor 1100 V grade 10 SQ mm 3 core into the bore well along with the submersible pump setfrom the startercomplete all as specified & directed
60M&L for Transportation of submerssible pump set 25 HP from Pump House to workshop and back to Pump House after repair lowering the pumpset along column pipe submersible cable using chain pully block manually and connectong with the existing rasing main all electrical connection, testing complete all as specified & directed
61S&F in repair DOL starter conforming to IS 19947-4 suitable for Doser pump set 0.5 HP complete testing and commissioning including taking down / dismantling the old items complete all as specified and directed..
62Repairs & cleaning of valve chamber of size 500X500X500 mmby descaling accumulated water and removing all sludge,vegetables and carry out all masonry work like plastering,PCC flooring and applying two coat of white wash on innerand outer surfaces and applying two coats of synthetic enamel paint over a coat of metal primer on metallic opening door, sluice valve and pipeline including necessary welding work to repair door, hinges including taking down / dismantling the old items complete all as specified and directed.,
63All as per item No. 55 above but valve chamber of size 750x750x750mm. complete all as specified and directed.
64M&L in repair for construction of valve chamberof size 500X500X500 mm (internal dimension) with PCC 1:4:8 for foundation 150 mm thick , brick work built with CM 1:6 , PCC 1:3:6 coping 50 mm , plastering 15 mm thick in CM 1:6 to all internal and exposed surfaces including excavation ,earth work in hard / dense soil , MS sheet cover 4 mm thick and with MS angle iron 50 mm x 50 mmx 6 mm as per existing sizewith locking arrangement embedded in PCC suitable for 25/40/50 mm gate valves and painting the MS cover with two coats of synthetic enamel paint over one coat of red oxide / metal primer on metallic sheet, hinges etc including taking down / dismantling the old items complete all as specified and directed.
65M&L forfabricationfor repair & servicing of sluice valve of size 150 mm boreby replacement of stainless steel /Brass spindle /gun metal spindle ,checknut , Gland rope, side nobe lock nuts etc (Note Brass spindle shall be fabricated from solid round bar having did not less than dia of the largest section of the spindle by maching / lathe work), and refixing in the position,complete, all as specified and directed.
66M&L forfabricationfor repair & servicing of sluice valve of size 100 mm boreby replacement of stainless steel /Brass spindle /gun metal spindle ,checknut , Gland rope, side nobe lock nuts etc (Note Brass spindle shall be fabricated from solid round bar having not less than dia of the largest section of the spindle by maching / lathe work), and refixing in the position,complete, all as specified and directed.
67M&L forfabricationfor repair & servicing of sluice valve of size 80mm boreby replacement of stainless steel /Brass spindle /gun metal spindle ,checknut , Gland rope, side nobe lock nuts etc (Note Brass spindle shall be fabricated from solid round bar having not less than dia of the largest section of the spindle by maching / lathe work), and refixing in the position,complete, all as specified and directed.
68S&F in repair/replacement ofsluice valve, cast iron body, ISI marked and iron wheel head, flanged, class PN-1.6,IS: 14846-2000including jointing material, rubber gasket, nuts, bolts, etc complete of 150mm bore complete all as specified and directed.
69S&Fin repair/replacement ofsluice valve, cast iron body, ISI marked and iron wheel head, flanged, class PN-1.6,IS: 14846-2000 including jointing material, rubber gasket, nuts, bolts, etc complete of 100 mm bore . complete all as specified and directed.
70S&Fin repair/replacement ofsluice valve, cast iron body, ISI marked and iron wheel head, flanged, class PN-1.6,IS: 14846-2000 including jointing material, rubber gasket, nuts, bolts, etc complete of 80 mm bore . complete all as specified and directed.
71S&F in repair/replacement ofNon return valve of CI flanged end, class-I, ISI marked with rubber packing, nuts & bolts etc complete of 100 mm bore . Make: Kirloskar/L&T/BIR.including taking down / dismantling the old items complete all as specified and directed.
72M&L for Service and repair of Chlorine Dosing Pump alongwith connected items complete all as specified and directed. Note: All itmes required for Service will be measure and paid separately.
73Supply and replacement of following parts of chlorination pumping set pump and motor of capacity 180 watts ;-
74Suction valve assemblycomplete all as specified and directed.
75Injector valve assemblycomplete all as specified and directed.
76Dosing head assemblycomplete all as specified and directed.
77FRP container of capacity 150 ltrcomplete all as specified and directed.
78Ram assembly Injector valve assemblycomplete all as specified and directed.
79Double ball valvecomplete all as specified and directed.
80Supply only Sodium Hypochlorite solution grade 1 containing apprppirate Quantities of chlorinations dipensiates/corrosion inhibitors to prevent encrustation /Scaling in distribution system of approved and tested fromGovt lab or equivalent testing authority(not more than two months of packing ) (chlorine concentration 10% or more) for treatment of drinking water complete all as specified and directed.
81Draining out water from over head reservoir of 50000 Gln capacity , removing sludge deposited, scales and other impurities from inside the tank thoroughly by scrapping with wire brushes, broom stick to make the surfaces free from sludge deposit and impurities, cleaning& washing the surfaceswith bleaching powder solution including rewashing with fresh water andwriting letters /figures like “Tank cleaned on________(date) and Due date_____ boldly & prominently with thick synthetic enamel with height & width of letters/figures 15cm & 10cm respectively in prominent places of tank ,white washing inside and out side distemper colourcomplete OH Tank as directed.and also painting the all in comming , out going, over flow CI/DI water main including scarping out the old paintingand applying two coats of synthetic enamel paint over a coat of red oxide with proper colour coading and marking complete all as specified and as directed. Note :- Scafolding work inclded in the rate quoted.
82M&L for writing letters or figures not exc 30 cm height in block Roman, Italian or iNdian letters including stops, comma, arrows, brackets, dashes etc on walls, sign boards (black or yellow or as required base) including two coats of oil paint over a coat of white base synthetic enamel paint complete all as specified and directed.
83Test and submit the test report of samples of portable waterfor Chemical/Biological test reportfor the samples of portable water in the directed location from Engineerin charge and submit the Chemical/Biological test report from thereputed state / Central government water testlab and producing test reports to engineer incharge when ever directed complete all as specified and directed.
84M&L for fixing of CI fittings / specials like Bend (any rsadius and angle) , Taper any type ( straight , bends,increasing,decreasing,or double socket etc), Tee pieces single byanch "Y" junction, double branch cross (all socket or socket and spigot), collar caps and plugs etc upto 150 mm dia complete all as specified and directed.by Engr-in-Charge.
85M&L for Flange joints by digging out up to depth of existing pipe line and complete the joint by using D-joint including necessary flange of 20 mm thick, 6 mm thick rubber insertion, nuts,bolts,Washers including bailing out the accumulated water in the trenches, complete,all as specified and directed by Engineer in charge.
86All as above but for 100mm borecomplete all as specified and directed.
87All as above but for 80mm borecomplete all as specified and directed.
88Taking out/down of old U/S GI pipeline for the following size from excaveted trenches including removal of fitting all as directed for necessary replacement / relaying of serviceable GI pipeline complete all as specified and directed by Engr-in-Charge.
89All as above but 100mm bore pipe. complete all as specified and directed.
90All as above but 80mm bore pipe. complete all as specified and directed.
91All as above but 50mm bore pipe. complete all as specified and directed.
92All as above but 40mm bore pipe complete all as specified and directed.
93All as above but 25mm bore pipe. complete all as specified and directed.
94All as above but 20mm bore pipe. complete all as specified and directed.
95All as above but 15mm bore pipe. complete all as specified and directed.
96Relaying of GI pipe after removal of scalling , cleaning and flushing etc includingsupply and fixing of new fittings of following sizes of any grade in trenches and testing complete all as specified and directed.
97All as above but 100mm bore pipe. complete all as specified and directed.
98All as above but 80mm bore pipe. complete all as specified and directed.
99All as above but 50mm bore pipe. complete all as specified and directed.
100All as above but 40mm bore pipe. complete all as specified and directed.
101All as above but 25mm bore pipe. complete all as specified and directed.
102All as above but 20mm bore pipe. complete all as specified and directed.
103All as above but 15mm bore pipe. complete all as specified and directed.
104Relaying only of GI pipe after removal of scalling , cleaning and flushing etc includingsupply and fixing of new fittings of following sizes of any grade in floor,walls or in ceiling and testing complete all as specified and directed.
105All as above but 25 mm bore pipe. complete all as specified and directed.
106All as above but 20 mm bore pipe. complete all as specified and directed.
107All as above but 15 mm bore pipe. complete all as specified and directed.
108Supply & laying only of GI pipe medium grade, with all fittings, laid in trenches or on walls, complete, all as specified and directed .complete all as specified and directed.
109All as above but 100mm bore pipe. complete all as specified and directed.
110All as above but 80mm bore pipe. complete all as specified and directed.
111All as above but 50mm bore pipe. complete all as specified and directed.
112All as above but 40mm bore pipe. complete all as specified and directed.
113All as above but 25mm bore pipe. complete all as specified and directed.
114All as above but 20mm bore pipe. complete all as specified and directed.
115All as above but 15mm bore pipe. complete all as specified and directed.
116Taking out U/S gate valves from pipe linefor necessary replacement , excavation ,necessary earth work etc of following sizes of any grade in trenches /walls/ceiling etc includingtesting complete all as specified and directed. f the following sizes.
117All as abovebut 50 mm diacomplete all as specified and directed.
118All as abovebut 40 mm diacomplete all as specified and directed.
119All as abovebut 25 mm diacomplete all as specified and directed.
120All as abovebut 20 mm diacomplete all as specified and directed.
121All as abovebut 15 mm diacomplete all as specified and directed.
122S & F Gun metal gate valve in repair with iron wheel head, screwed both ends for iron pipe of the following sizes. complete all as specified and directed.
123All as abovebut 50 mm diacomplete all as specified and directed.
124All as abovebut 40 mm diacomplete all as specified and directed.
125All as abovebut 25 mm diacomplete all as specified and directed.
126All as abovebut 20 mm diacomplete all as specified and directed.
127All as abovebut 15 mm diacomplete all as specified and directed.
128Repair/Maint of water leakages for GI pipeline joints in ground/trenches and identifying the defect and open carefully the joint portion of the pipeline duly excaveted the trench and removing the defective joints in the existing pipelines and provide with a new pipe joints etc as per the site requirement to make the joint 100% leakproof including excavation and testing complete all as specified and directed for the following size:complete all as specified and directed.
129All as above 100 mm bore pipelinecomplete all as specified and directed.
130All as above80 mm bore pipelinecomplete all as specified and directed.
131All as above 50 mm bore pipelinecomplete all as specified and directed.
132All as above40 mm bore pipelinecomplete all as specified and directed.
133All as above 25 mm bore pipelinecomplete all as specified and directed.
134All as above20 mm bore pipelinecomplete all as specified and directed.
135All as above15 mm bore pipelinecomplete all as specified and directed.
136Supply, installation, testing & commissioning of AMF( automatic mains failure) panel suitable for 62.5 KVA DG set . The panel shall be made out of CRCA sheet of thickness 3 mm, duly powder coated finish of min size 150cm (height)X 100cm (width) X 60cm (depth0 outdoor type, double door type,floor mounting type, front and rear door openable type hinged from panel door for easy accessibilty, dust proof, vermin proof, suitable for 415 volts, 3 phase, 4 wire,(100% neutral), 50Hz supply system having busbar chamber with insulated aluminium busbar 200 Amps rating (100% neutral) rated busbar, factory made (CPRI approved), making locking arrengement, panel mounted on angle iron 40x40x5 mm frame having 4 Nos legs 45 cm long of 40x40x5mm angle iron,15 mm grouted in PCC ratio 1:2:4 and 30cm clear space from ground/ floor level complete incl internal wiring with suitable of copper conductor cable, it also include supply & fixing for following accessories:- complete all as specified and directed.
137(i) Digital voltmeter, 0-500volts, flush mounting type with selector switch to read voltage of mains & DG set (ii) Digital ammeter, 0-200Amps,lush mounting type with selector switch incl CTs of ratio 100/5 to read current of mains & DG set-02 Nos (iii) Digital frequency meter, 45-55Hz, 5 Amps, flush mounting type with built- in trandsuer to read frequency of DG set -01 No (iv) Digital power factor meter, 415 volts, 50 Hz, 5 Amps, flush mounting type with built in transduser to read PF of DG set -01No (v) Battery charger suitable for input 220/240 Volts, 50 Hz suitable for charging current and voltage- 01Nos, 150 AH, 12 Volts battery for boost/trickle charging complete with suitable ammeter & voltmeter for measuring the charging current & voltage -01 No (vi) LED indicating lamp 230 volts AC for DG/mainssupply, ON/OFF indicating & different relay/ operation position indication -01 Set (vii) MCCB 4 pole, 100 amps, 35 kA rupturing capacity, 415 volts, adjustable thermal megentic release type for incoming-01 No (viii) Automatic transfer switch (ATS) 100 Amps, 415 Volts, 4 pole, 50 Hz, automatic & manual type with inbuilt time delay with slector switch , indication complete duly connected with MCCBs by 200 amps busbar make:- Legrand, Havells, L & T- 01 No
138(ix) Contol box for automatic and manual swithing ON & OFF of DG set, transfer of load with time delay to engine start and stop having annunciator/ relay complete duly connected with its auxillary relay/ timer to protect DG set from LLOP & HWT with MCBs for relays control / protection as required to indicate fault and auto switching OFF in case fault of DG set complete with all standerd aceessories and fixtures having suitable capacity power pack unit - 01 set (x) Start/ stop push button -01set (xi) All accessories wired with & including suitable size PVC insulated copper conductor cable including connection of same from DG set complete all as required at site-01 Jobcomplete all as specified and directed.
139S & Laying synthic rubber insulated mat 2.5 mm thick for voltage up to 11 kV for eletrical purpose as per IS 15652-20026 suitable for eletrical shok safty of size 2 x 1 mtr complete all as specifiedcomplete all as specified and directed.
140M&L in replacement earthing complete with galvanized steel earth plate electrode 60 cm X 60 cm X 6.0 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level connecting to the GI strip 32 x 6mm, by means nut bolt, nuts, check nuts and washer of the GI Earth wire protected by provision of GI light grade pipe 40 mm incl provision of concrete pit in PCC (1:2:4) type B-1 using 20 mm graded stone aggregated with 40 mm thick cover with RCC (1:2:4) reinforced with XPM (weight not less than 4 Kg / Sqm) and frame of angle iron 25mm X 25 mm X 3mm with lugs 2 Nos and with 6 mm dia MS bar handle made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, taste point made out of phosphorus bronze with fixing arrangement, funnel, wire mesh andearth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding than 50 mtr, all as per electric plate No 3 of SSR Part I 2009 and connection to earth test point all as specified including testing on completion”. complete all as specified and directed.
141S&F energy saving ceiling fan of 1200 mm sweep of 330-370 RPM, 220-240 volts, AC, 50 Hz, ISI marked with five star rating including hanging with the help of fan hook, down rod up to 04 feet and connecting up with provn of 3 core copper flexible cable of size 1.5 sqmm from ceiling rose to fan complete all as specified and directed.Make : Havells, Model: ES-50 Premium or Usha, Model: Energia Star ISI or Crompton Greaves, Model: Empower 50