| 1 | Supply , laying , testing & CommissioningUG cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (Heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm, 4 core,some cable shall be laid at new place with suitable thimbles complete all as specified and directed by Engr-in-Charge. |
| 2 | Description all as per item No-01 butsize 16 sq mm, 4 core. |
| 3 | Description all as per item No-01 butsize 25 sq mm, 4 core. |
| 4 | Description all as per item No-01 butsize 50 sq mm, 3.5 core. |
| 5 | Description all as per item No-01 butsize 70 sq mm, 3.5 core. |
| 6 | Description all as per item No-01 butsize 95 sq mm, 3.5 core. |
| 7 | Description all as per item No-01 butsize 120 sq mm, 3.5 core. |
| 8 | Taking out of old serviceable / unserviceable PVC under ground LTcable of any size and type fixed on pole, wall or laid in floors, trenches, across road crossing etc ,including taking out of cable covers of precast PCC / RCC slab or brick cover etc setting aside serviceable materialsin safe custody for reuse and or unserviceable materials consider as schedule of credit complete all as specified and as directed.Note:-i). Dismantling of clamps nuts bolts etc, taking out of GI pipe in cable protection shall be measured and paid separately under respective item of this schedule. ii).Cost for making good the disturbed surfaces of floors / walls in cement mortar 1:3 shall deemed to be included in the unit rate quoated . However cost for making good the disturbed surfaces of roads with PCC and hard core filling is out of scope of this work and shall be measured and paid separetely under respective item 20 of this schedule. |
| 9 | Laying only of serviceable LT UG cable 95 sq mm, 3.5 core. of any size and type in trenches, floors, across road crossing, or fixed on poles, walls, or passing through pipe, cable obtained from item No. 8 here-in-before complete all as specified and as directed.Note:-i). Handling of UG cable to working site as ordered shall be carried out by the firm and rate for the same shall deem to be included in the unit rate . |
| 10 | Laying only of serviceable LT UG cable 120 sq mm, 3.5 core. of any size and type in trenches, floors, across road crossing, or fixed on poles, walls, or passing through pipe, cable obtained from item No. 8 here-in-before complete all as specified and as directed.Note:-i). Handling of UG cable to working site as ordered shall be carried out by the firm and rate for the same shall deem to be included in the unit rate . |
| 11 | Laying only of serviceable brick / PCC slab coverobtained from item No 8 here-in-before for cable protection cover laid width wise along length of cable complete all as specified and as directed. |
| 12 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth and getting out in any type ofsoil for laying of LT UG cablescomplete. Note:- The Ratequoted deemed to including cutting and removal of PSP Sheets wherever occured during excavation and the same shall be stacked at desired location as directed at site |
| 13 | Returning, filling in,including spreading levelling, watering and well ramming in layers not exceeding 25 cm thickin hard dense soil |
| 14 | Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point |
| 15 | Dry coarse sand as cushioning to under ground cable provided with layer of 8 cms deep before laying the cable and 15 cms deep after laying and stretching the cable, punned to 18 cm thick complete all as specified and as directed by Engr-in-Charge. NOTE Only punned thickness shall be measured for payment purpose. |
| 16 | Sub class \"B\" old size bricks well burnt as covering to under ground cables , laid dry, flat over the cables on sand cushioning with width equal to length of the brick as mechanical protection to cable, complete all as specified and directed. |
| 17 | M&L Plain cement concrete 1:4:8 type D2 using 40mm graded stone aggregate for foundation of poles complete all as specified and as directed. |
| 18 | M & L PCC 1:3:6 type C1 using 20 mm graded stone aggregate for coping of poles/road/plinth blocks of LT poles etc incl fair finishing the exposed surfaces even and smooth without using extra cement includingnecessary form work complete all as specified and directed. |
| 19 | Supply and laying of DWC (Double Wall Corrugated) HDPE Pipe, ISI Marked IS 16205 Part-II, of outer dia of 63 mm and inner dia 50 mm with smooth internal and profiled external surface for non pressure under ground cable including all connected accessories like coupler, \"O\" Ring etc, for protection of cablecomplete all as specified and as directed. |
| 20 | Supply and laying of DWC (Double Wall Corrugated) HDPE Pipe, ISI Marked IS 16205 Part-II, of outer dia of 77 mm and inner dia 63 mm with smooth internal and profiled external surface for non pressure under ground cable including all connected accessories like coupler, \"O\" Ring etc, for protection of cablecomplete all as specified and as directed. |
| 21 | M & L for cutting through existing road surfaces i.e. surfacing PCC soling etc, and making trench of minimum 500mm wide 100cm in depth along the cross section of road for laying of pipes or UG cables, including returning filing in, well ramming & removal of surplus spoil to a distance not exc. 50 mtrs & repairs to road surfaces to match with existing specification after laying the pipes/cable etc. all as specified and directed. |
| 22 | S & F cable route indicator made out of 25 x25 x 4 mm angle iron, 300 mm long embedded in PCC block of suitable size with moulded lettter LT CABLEsuitably inscribed on CI circular plate 6 mm thick 60 dia complete incl neccessary PCC 1:3:6, type C-2 (using 40 mm graded aggrregate)block of suitable size and neccessary earth work and excavation all as specified and directed. |
| 23 | Supplying, laying and spreading (thickness as directed by Engineer-in-Charge) dry/loose coarse aggregates (granite, trap, Basalt), grading I, 90 to 40 mm or grading 2, 63 to 40 mm size, including well ramming,under 2/4 pole structure including cleaning and uprooting the wild grass and other vegitation complete all as per direction by Engineer-in-charge. |
| 24 | Brick work using old size bricks, straight or curved on plan exceeding 6.00 metre mean radius built in cement mortar (1:6), including dismantling of UNSV brick work complete all as specified and as directed by Engineer-in-Charge. |
| 25 | Rendering 10 mm thickon fair faces of brick work or concrete surfaces, finished even and smooth (without using extra cement) on walls in cement mortar (1:6) complete, all as specified and as directed by Engineer-in-Charge. |
| 26 | Supply and Fixing GI tubing light grade 40mm dia along the wall/in trenches/in duct/in culvert/road crossing and including provisioning of suitable mild steel flat iron clamps and bolts, nuts and double washers etc for holding of GI pipe alongwith poles including taking out old broken GI pipes, complete all as specified and as directed by Engr-in-Charge. |
| 27 | Supply and Fixing GI tubing light grade 50mm dia along the wall/in trenches/in duct/in culvert/road crossing and including provisioning of suitable mild steel flat iron clamps and bolts, nuts and double washers etc for holding of GI pipe alongwith poles including taking out old broken GI pipes, complete all as specified and as directed by Engr-in-Charge. |
| 28 | Supply and Fixing GI tubing light grade 80mm dia along the wall/in trenches/in duct/in culvert/road crossing and including provisioning of suitable mild steel flat iron clamps and bolts, nuts and double washers etc for holding of GI pipe alongwith poles including taking out old broken GI pipes, complete all as specified and as directed by Engr-in-Charge. |
| 29 | Supply and fixing aluminium thimbles in replacement suitable for under ground LTcables of following sizes including cutting of exsting burn/dammaged cable after disconnecting from exsting position ,extending the cable from cable loop including neccesory earth work and reconnecting the same. of Size of16 Sqmm |
| 30 | Description all as per Item No. 28 but size25 Sqmm |
| 31 | Description all as per Item No. 28 but size35 Sqmm |
| 32 | Description all as per Item No.28 but size50 Sqmm |
| 33 | Description all as per Item No. 28 but size70 Sqmm |
| 34 | Description all as per Item No. 28but size95 Sqmm |
| 35 | Description all as per Item No. 28but size120 Sqmm |
| 36 | Description all as per Item No. 28 but size185 Sqmm |
| 37 | Supply & FixingPVC insulated sheathed service wiretwin core 6 Sqmm aluminium solid conductor 1100 volts grade incl taking down old unserviceable one complete all as specified and directed. |
| 38 | Supply & FixingPVC insulated sheathed service wiretwin core 10 Sqmm aluminium solid conductor 1100 volts grade incl taking down old unserviceable one, complete all as specified and directed. |
| 39 | Supply & FixingPVC insulated sheathed service wiretwin core 16 Sqmm aluminium solid conductor 1100 volts grade incl taking down old unserviceable one complete all as specified and directed. |
| 40 | Supply and FixingChange Over Switches ON-Load320Amps 4 poleSheet metal enclosercomplete all as specified and directed. |
| 41 | Supply and FixingChange Over Switches ON-Load200Amps 4 poleSheet metal enclosercomplete all as specified and directed. |
| 42 | Supply and FixingChange Over Switches ON Load100Amps 4 poleSheet metal enclosercomplete all as specified and directed. |
| 43 | Supply and FixingMCCB 250Amps 4 pole 25 KAwithadjustablethermal and fixed magnetic setting, fixed in repairs complete all as specified and directed. |
| 44 | Supply and FixingMCCB 200Amps 4 pole 25 KA with Sheet metal encloser withadjustablethermal and fixed magnetic setting, fixed in repairs complete all as specified and directed. |
| 45 | Supply and FixingMCCB 160Amps 4 pole 25 KAadjustablethermal and fixed magnetic setting,complete all as specified and directed. |
| 46 | Preparation of old painted surface of 9 Mtr. steel tubular poles above the top of PCC coping.Painting of pole from top of coping to a height of 1.5mtr (bottom portion of pole) with two coats of synthetic enamel paintin black and yellow alternate strip and painting the rest portion of pole of (approx length 7 mtr)including painting of cross arms/clamps etc complete with two coats of synthetic enamel aluminium paintand to the entiresatisfaction of Engineer-in-Charge complete all as specified and directed |
| 47 | M & L for preparation of old cement based painted surfaces of RCC pole 9 mtr by cleaning of depositedmaterials,and painting withone coat of exterior emulsion weather coat paint of approved make and colour complete all as specified and directed byEngineer-in-Charge |
| 48 | M&L for fault detection in damaged UG cables using cable fault detector/locator, vehicle mounted to accuracy of 2m for various locations inside Air Force Stnfor UG cables of any sizeupto240 Sqmm including excavation & earthwork in any type of strata of size 4x2x0.6m to visually inspect/repair the damaged cable when and where directed by Engr-in-charge. |
| 49 | S & fix LT Cable joining kitstraight through heat shrinkable complete with jointing materials suitable for LT armoured cable 4 core of size 10 to 50 Sqmm all as directed. |
| 50 | S & fix LT Cable joining kitstraight through heat shrinkabale complete with jointing materials suitable for LT Armoured cable 4 core of size 70 to 120 Sqmm all as directed (Make 3M / Reychem) |
| 51 | S & fix LT Cable joining kitstraight through heat shrinkable complete with jointing materials suitable for LT armoured cable 4 core of size 150 to 240 Sqmm all as directed. |
| 52 | S & fix LT Cable end joining kitheat shrinkable complete with jointing materials suitable for LT armoured cable 4 core of size 10 to 50 Sqmm all as directed. |
| 53 | S & fix LT Cable end joining kitheat shrinkable complete with jointing materials suitable for LT armoured cable 4 core of size 70 to 120 Sqmm all as directed. |
| 54 | S & fix LT Cable end joining kitheat shrinkable complete with jointing materials suitable for LT armoured cable 4 core of size 150 to 240 Sqmm all as directed. |
| 55 | Supplying, Installing, Testing and Commissioning Outdoor type Cubical Feeder Pillar Box of size 1.00m x.0.90m x 0.50m, platform mounted factory made totally enclosed dust and vermin proof (protection class IP-54) single shutter front opening with locking arrangement complete made of angle iron 50 mm x 50 mm x 6 mm thick frame work, outer shell made out of 3.15 mm thick MS sheet and inner shell made out of 2.0mm thick MS sheet duly painted with powder coated paint over a coat of red oxide primer over outside and inside complete.The panel board shall be equipped with the following accessories :- |
| 56 | (a) Aluminium Busbar 300 Amps Capacity TPN colour coded with heat shrinkable sleeves - 01 Set(b) Incoming MCCB 125 Amps FP 415 Volts AC with adjustable thermal magnetic trip release 25 KA,with double break contacts with spreader and phase barrier -01 Nos(c) Outgoing MCCB 63 Amps FP 415 Volts AC with adjustable thermal magnetic trip release 16 KA,with double break contacts with spreader and phase barrier -04 Nos(d) Indicator Lamp RYB - 01 Set of Three(e) Digital Voltmeter Square Flush Pattern 0-500 V of size 96 Sqmm with Selector Switch -01 Nos(f) Digital Ammeter Square Flush Pattern 0-200 A of size 96 Sqmm with Selector Switch and CT Coils -01 Nos.Notes:-1. The minor items such as Lugs, Nuts and Bolts, Washers, Top Insulators, Sleeves, provision of extra holes in bus bar etc. shall be provided by the Contractor as directed. The Quoted Rate shall be deemed to include the cost of the same and nothing extra shall be admissible from the department on this account what-so-ever.2. All internal wiring shall be done with suitable size of PVC insulated solid copper conductor FRLS cable conforming to IS-694.3. The Panel drawings shall be got approved from GE before placing the Order.4. The bus connection for cable from main bus bar to outgoing MCCB will be connected through suitable rating bus bar strip type duly insulated. |
| 57 | Supply, installation , commissioning and testing LT feeder pillar boxin replacement of suitable size,outdoor cubical type floor mounted factory madeof CPRI approved factory, totally enclosed vermin proof with front and rear opening with IP-54 protection as per IS - 8623 duly powder coated , fabricated out of 3.15 mm thick mild steel sheet mounted on frame of mild steel angle iron 60 cm x 60 cm x 6mm and , 45 cm aboveground level duly supported with mild steel angle iron struts 60 cm x 60 cm x 6mm thick and embedded in PCC foundation inPCC 1:2:4, type B-1 , using 20 mm graded crushed stone aggregate , with suitable 415 Volt, 3 phase, four wirecopper bus bar of rating capacity 400 Amps duly drilled holes for connections, R-Y-B-N insulated with different colour code and sleeved mounted on insulators complete prewired and cable connection with copper conductor wire upto Aluminium bus bars including all incoming and outgoing cable connections with suitable size of copper lugs/ glandincluding supply and fixing of MCCB four pole, 415V,I/C- 200 Amp. 25KA-01No Outgoing 63 Amp 4 pole- 05 Nos. including taking out old unserviceable, complete all as specified and directed by Engr - in- Charge. |
| 58 | Supply , installation, Commissiong & Testing of LT feeder pillar compartmentalised design of size not less than 70 x 70 x 25 cm suitable for 440 volt 3 phase 4 wire system made out of 3.15 mm CRCA sheet powder coated having gasketed front two hinged doors with locking arrangement including bottom and top detachable gland plate complete with suitable size of rust proof nuts, bolts, and washers etc..complete with mounting accessories including the following components:-(a) Four 30cms long Aluminiumbus bar 200 Ampmounted on epoxy insulators provided with rust proof nuts bolts and washers (b)I/C MCCB-125 AmpLED indicating lamps - 3 nos. (Red ,Yellow, Blue) |
| 59 | M & L forrepair Any Size of LTPanelofPanel door ,hinged nut .bolitsclampand Welding and fabrication work as required complete all as specified.and directed by Engr - in- Charge |
| 60 | Supply & Fixing inRepairs Digital 3 phase Voltmeter class 1 flush mounting of Size 96x96 mm Suitable for 240 voltage complete all as directed by Engr-in- Charge. |
| 61 | Supply & Fixing inrepairs Digital 3 phase Ammeter5A class 1 flush mounting of Size 96x96 mm Suitable for 440 voltage with selector switch in LT panel and DG set LT panel complete all as directed by Engr-in- Charge. |
| 62 | Cutting of tree branches of anygirth along HT/ LT OH lines & street light pole at a distance not less than 2 meter on either side of the pole cleaning of bushes and shrubes of any type along entire RM of pole. Cleaning /prunning should be carried out as and when required during entire running period of contract or as when directed by E-I-C. A fine of one time quated rate per running meter will be deducted if the over groth is found along the pole all as directed by Engr-in- Charge. |
| 63 | SCHEDULE \"A\" PART-II (Schedule of credit) Credit amount of Rs (Refer schedule of credit) for retrieved material mentioned in Sch \"A\" Part-II of Tender documents in PDF form will be deducted offline during acceptance of tender of lowest bidder. |
| 64 | Note: (1) The repair has to carried out as and when required basis and accordingly site will be available in piecemeal wise and as directed by Enginer-in-Charge in the domestic area of Air Force station. |