Tender For Special Repair To Parameter Lights And Electrical Infrastructure At Af Stn Udhampur, udhampur-Jammu And Kashmir

Military Engineer Services-MES has published Tender For Special Repair To Parameter Lights And Electrical Infrastructure At Af Stn Udhampur. Submission Date for this Tender is 22-05-2024. Electrification Work Tenders in udhampur Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

43234973
Tender For Special Repair To Parameter Lights And Electrical Infrastructure At Af Stn Udhampur
Open Tender
Indian
Jammu And Kashmir
udhampur
22-05-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Special Repair To Parameter Lights And Electrical Infrastructure At Af Stn Udhampur

Key Value

Document Fees
INR 1000 /-
EMD
INR 115000.0 /-
Tender Value
INR 60 Lakhs /-

Attachment

FileName File Description File Size
917b9a0e-446c-4467-b22e-5d517e2fafbe.html Tender Notice 0 KB
BOQ_728757.xls Tender Document 0 KB
Tender42.pdf Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

Name of Work : SPECIAL REPAIR TO PARAMETER LIGHTSAND ELECTRICAL INFRASTRUCTURE AT AF STN UDHAMPUR
Sl. No. Item Description
1M & L for LED Street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics with suitable size of SPD"s complete with IP 66 protection, PF>= 0.90, lumen efficacy>= 100 lumen/watts, 5700 K, including 3 core flexible copper cord size 2.5 sqmm, PVC insulated and PVC unsheated (from junctiion box to street light fittings) to be fixed in the bracket at existing pole/bldg or other extra welding works complete all as specified and directed by Engr-in-Charge. Note :- (i)T&P required for fixing of lights above the security pole such as ladder, Crane vehicle, Hand Glooves, Electric shock Proof shoes for electrician, menpower etc, are inclusive in the quoted rate. (ii)Rate of necessary arrangement for fixing LED light on existing bracket like reducer or extention of pipe by suitable size of GI pipe as per dia of LED light by welding etcare inclusive in the item rate. (iii) Contractor is responsible for taking the shutdown of electric fence of IPSS under 39 Wing and any damage to elelctric fence will be repaired by the contractor are inclusive in the quoted rate. (i)A certificate from the manufacturer for warranty minimum upto 05 years shall be obtained and submitted to GE/AGE. (iv) Any touch up of the existing surface due to changing of fittings shall be done by contractor with similar surface finish without extra cost to the department. (v) CA No shall be written on each fitting before installation. (vi)Driver shall be potted antivibration type. (vii). LM-79 and LM-80 test report with 1 Lakh burning hours LED life from NABL lab shall be povided. (viii)CRI (Colou Rendring Index) of fixture shall be > 70. (ix) CCT (Colout Correlated Temprature of fixture shal be 5700K ± 300 K. (x) System Lumen Efficacy shall be >100Lm/W (xi)5KV separate Surge Protector shall be provided as a part of fitting. (xii) 5 years Warrantee shall be provided by contractor suppoted by OEM covering all parts of luminaire.
2S & F street light bracket made out of 25/32/40 mm dia GI mediumgrade tubing not less than 1.5 Mtr long bend to shape including pole clamps made out of 50 x 6 FI and nut bolts and washers including two coat of Aluminium painting over one coat of red oxide painting complete all as specified and directed by Engr-in-Charge.
3Supply and fixing cable 1.5 Sqmm 3 core cable, PVC insulated and PVC round sheathed, copper conductor (flexible) industrial cable, 1100 volt, confirming to IS :694 including taking down of unsv cable. Note: Quoted rates include following fixing arrangement:- 1.cable shall be fixed by passing through poles upto light fitting 2. if passing through poles is not feasible cable shall be drawn through PVC conduit (20 mm) properly fixed to pole & boundary wall with clamps
4LT Cable junction box outdoor shall be made out of Polycarbonate with glass fiber reinforced size not less than 205mm x 255mm x 112 mm(the cable size upto 25 sqmm). The polycarbonate junction box shall be environmental friendly, recyclable, halogen & silicon free, anti acid & anti corrosive. The Junction Box shall be rated for Degree of ingress Protection IP 65 in accordance with IEC 60529.Weatherproof, UV resistant. The gasket material of junction box shall be Polyurethane and the gasket shall be internally embedded. The Junction Box shall be complies with requirements of the standards IEC 60998. The Junction Box with 25 Amp Connectors or Terminal Trip or Bus Bar. The Junction Box / Enclosure shall be tested as per IEC including one No & 4 pole connector withone No MCB SP "C" curved 6-32 Amps and chromium plated clamps and nut bolts, cable glands or cable grommets with lock nuts of 2 Nos for each box including fixing arrangement on the wall/ pole with help of suitable size of iron strip/ hole pastner/ nut bolt etc complete all as per manufacturer’s Make : Cat Part :- DK 2500 B of Hensel or equivalent of Siemens/GE Power/Legrand as approved by GE.
5Supply and fixing of following sizes of GI tubing light grade bore cut to size and fixed along the pole /road/wall for cable protection all as required at site or directed by Engineer-in -charge Note :- (Wherever reqmt of clamp, nuts, bolts and washers, rate shall be included in the quoted rate)
6GI tubing light grade of 25 mm size including fitting
7GI tubing light grade of 50 mm size including fitting
8GI tubing light grade of 80 mm size including fitting
9Supply and LayingCable XLPE insulated screened PVC bedded galvanized steel strips or wire armoured,cables (heavy duty) ISI marked with stranded aluminium conductor, 1100 volts grade and connecting and testing and laying in trenches, under floors/ roads or on walls complete including taking down old complete all as specified and directed offollowing sizes :- Note:-Earth work, excavation shall be measured & paid separately under respective item of Schedule and wherever cable laying on walls and uses of thimbles, clamps etc rates shall deemed to be included in the quoted rates). The saddles for fixing on wall shall be of GI saddle fixed with drilling/holling/screws/hole fastners etc shall be installed at each 60 Cm approx distance all as directed and specified by Engr-in-Charge.
1016 Sqmm,4 core cable
1110 Sqmm/, 4 core cable
1295 Sqmm,3½ core cable
13150 Sqmm,3½ core cable
14Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for laying of cable and foundation of poles, stays and getting out in any type of soil, all as specified and directed by Engr-in-Charge.
15Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick each layer in any type of soil complete all as specified and as directed by Engineer-in-Charge.
16Removing surplus excavated material to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete, all as specified and as directed by Engineer-in-Charge.
17M & L for Sand cushioning to underground cable, provided with a layer 8 cm before and 15 cm after laying and stretching jointing and testing the cable all as specified and directed. by Engineer-in-Charge. Note: Punned thickness of sand shall be measured.
18M& L for Common burnt sub class ‘B’ brick laid flat in trenches over and across the length of cable with length of brick perpendicular to the direction of cable adjacent/abutting each other complete all as specified and directed for cable protection.
19Supply and fix heat shrinkable End termination kits and accessories of following capacities and type:-
20(a) Outdoor/indoor 120 to 150 Sqmm 3.5/4 core cable jointing kit for 1.1 KV grade cable
21(b) Outdoor/indoor 70 to 95 Sqmm 3.5/4 core cable jointing kit for 1.1 KV grade cable
22(c) Outdoor/indoor 10 to 16 Sqmm 3.5/4 core cable jointing kit for 1.1 KV grade cable
23Supply and fix heat shrinkable straight through joint kit and accessories of following capacities and type:-
24Straight through joint kit indoor/outdoor al conductor cable of size120 to 150 Sqmm and 3.5/4 core
25Straight through joint kit indoor/outdoor al conductor cable of size 70 to 95 Sqmm and 3.5/4 core
26Outdoor/indoor 10 to 16 Sqmm 3.5/4 core cable jointing kit for 1.1 KV grade cable
27Outdoor/indoor 10 to 16 Sqmm 3.5/4 core cable jointing kit for 1.1 KV grade cable
28M & L for installing/erecting of octagonal galvanised iron pole suitable for security/street light including single arm standard bracket, "J" type bolts, Excavation, Returing and filling works and removal of surplus soil to a distance not exc 50 mtr complete with PCC (1:3:6) type C-2 foundation of size 60x60x90 cm, size of pole 07 mtr height Hot deep galvanised octagonal pole with 130 mm bottom A/F 70 mm top A/F, made upto 03 mm thick HT sheet alongwith base plate (with bracket)including 1 mtr long hot dip galvanised single arm standard bracket made upto 40 NB dia GI pipe suitable to mount on pole all as specified and directed by Engineer-in-Charge.
29S&F of outdoor type timer panel factory made CPRI approved polycarbonate 3.15mm Thickness (shock proof,rust free, corrosion free,dust proof, acid and chemical resistant,fire retardant, powder coated with 7 tank process having high impact,made of halogen and silica free,recyclable material), UV resistant, having highgrade gasketmadeof polyurethane,should withstand glow wire test at 650C should be flame retardant,the feeder pillar panel should be as per ERDA Certification with switchgear assemblies as per IEC 60 439-1.following tests performed and passed and satisfactory : (1) Temperature Rise (2) Dielectric properties (3) short circuit withstand current Rate peak & short time withstand current and Rated conditional short circuit current (4) Effectiveness of protective circuits. (5) Clearance & creep age distance. (6) Mechanical operation, mounted on angle iron frame of size 40mm X40mmX6mm thick Complete with necessary PCC 1:3:6 foundation work of size 0.30 mtr depth and plinth of high 0.45mtr as directed at site.
30INSTRUMENT CHAMBER :- (i) RYB Phase indicating light LED type- 01 Set. (ii) Control MCB 6 A SP C Series - 01 Set. INCOMING:- (i) MCCB 63 Amps, 4 Pole, 10 KA, 50 Hz, 415 Volts-01 No. (ii) Power Contactor 3 Pole, 70 Amps. 50 Hz, 415 Volts- 01 No. (iii) Time Switch electronic type, QT one dial daily, 240/415 Volts, 50 Hz- 01 No. (iv) Auto Manual Selector Switch 6 A SP- 01 No. . (v) RED Phase indicating light LED type- 01 No.. Panel wiring for control circuit with copper flexible 1.5 Sq mm& powerwiring 10 Sqmm flexible. Note: In Case of failure, manual system should also be provided. The panel manufacturer should have following Govt. Approved Certificates: 1.Panel shall be installed at least 45 cm above ground 2.All civil/electrical work & material is deemed to be included in the quoted rates
31Supply & installation , testing & Commissining CPRI approved outdoor cubical type IP 54,LT feeder piller box suiable for 415 V, 3 phase 50 Hz , AC supply system, dust,weather& vermin proof, made of 3.15 mm thick CRCA sheet for outer shell and 2 mm thick for inner shell having TPN copper busbars of rating 600 Amp Cap.Bottom base channel of MS section not less then 100mmx50mmx5mm thick, entire panel shall have a common aluminium earth bar of size 25mm x5mm at the rear with 2 no earth stud,powder coated with 7 tank process double door both side opening single door system lockable/openable by key from both sides having flush pattern fancy locks with louvers. cable entry with glands, foundation/grouting on & including PCC as per site requirement with the following :- (a) Bus bar electrolytic grade copper and supported on Non-hygroscopic, non carbonising, corrosion resistance SMC insulator 600 Amp,4 pole, not less then 60 CM long mounted on insulators for incoming supply - 01 Setof 4 strips) (b)Phase indicator lamp RYB LED type-01 Set (c) digital voltmeter and ammeter 02 Nos. (d) CT of suitable ratio ( Set of three) Incoming: (a) MCCB 320 Amp 415V,50 Hz,FP,,36 ka, Ics= 100% Icu with thermal, magnetic trip, adjustable type overload settings: 0.67 - 1.0 x In , short circuit settingrelease 6 to 12 ln qty -01 Note:- 1.Panel shall be installed at least 60 cms above ground level 2. All civil/electrical work & material is deemed to be included in the quoted rates 3. Drawing of panel shall be got approved from GE
32Supply & installation and testing & Commissining CPRI approved outdoor cubical type IP 54,LT feeder piller box suiable for 415 V, 3 phase 50 Hz , AC supply system, dust,weather& vermin proof, made of 3.15 mm thick CRCA sheet, powder coated with 7 tank process,TPN copper busbars of rating 300 Amp Cap.Bottom base channel of MS section not less then 45mmx45mmx5mm thick, entire panel shall have a common aluminium earth bar of size 25mm x5mm at the rear with 2 no earth stud,double door both side opening single door system lockable/openable by key from both sides having flush pattern fancy locks with louvers. cable entry with glands, foundation/grouting on & including PCC as per site requirement with the following :- (a) Bus bar electrolytic grade copper and supported on Non-hygroscopic, non carbonising, corrosion resistance SMC insulator 200 Amp,4 pole, not less then 45 CM long mounted on insulators for incoming supply - 1 Set (Set of 4 strips) (b) Phase indicator lamp RYB LED type-01 Set (Set of three). (c) Digital Voltmeter & Ammeter - 02 Nos (d) CT Ration 100/05 CL 1.0 Tape Wound - 01 Set (Set of three) Incoming: (a) MCCB 160 Amp, 415V, 50 Hz,FP,,25 ka, Ics= 100% Icu fixed type, Qty -01 complete all as specified and directed by Engr-in-Charge. Note :- 1.Panel shall be installed at least 60 cm above ground 2.All civil/electrical work & material is deemed to be included in the quoted rates 3. Drawing of panel shall be got approved from GE
33Disconnecting and taking down old unserviceable of bus bar chamber and supply and fixing of Weather proof outdoor bus bar chamber, made out of 3.15 mm thick CRCA sheet comprising4 Nos Copper strips each of 400 Amps, powder coated with 7 tank process60 cm long duly insulated mounted on insulatorscomplete with 4 No’s mounting legs made out of 50 mm x 50 mm x 6 mm angle iron grouted in PCC block of size 30 cm x 30 cm x 90 cm (30 cm depth below ground level and 60 cm above ground level) in cement concrete 1:3:6, type C-2 (using 40 mm grade crushed stone aggregate), andconnections with size of aluminium thimbles, nuts, bolts & washers including cable glands at entry and outlet points including excavation and earth work, returning filling and removal of surplus soils, including taking out old unserviceable bus bar chamber complete all as specified and directed by Engr-in-charge .as per site requirement with the following :- (a) Bus bar electrolytic grade copper and supported on Non-hygroscopic, non carbonising, corrosion resistance SMC insulator 400 Amp,4 pole, not less then 60 CM long mounted on insulators for incoming supply - 1 Set Set of 4 strips) (b) Phase indicator lamp RYB LED type-01 Set (c) C.T"s of suitable ratio (Set of three) (d) Red,Yellow,Green Phase indicating Lights LED type 220V AC- 01 Set. (Set of three). (e)Incoming:- MCCB 250 amps , 36 KA 4 pole, Ics= 100% of Icu, adjustable type Qty- 01 No (f) Outgoing:-(i) MCCB 250 amps , 36 KA 4 pole, Ics= 100% of Icu, adjustable type Qty- 01 No (ii) MCCB 63 amps , 16 KA 4 pole, Ics= 100% of Icu, adjustable type Qty- 03 Nos Note:- The panel manufacturer should have following Govt. Approved Certificates: 1.Panel shall be installed at least 60 cm above ground 2.All civil/electrical work & material is deemed to be included in the quoted rates 3.Drawing of Lt feeder panel shall be got approved from GE.
34M & L for fixing of Weather proof outdoor bus bar chamber, made out of 3.15 mm thick MS sheet comprising4 Nos Copper strips each of 300 Amps, 60 cm long duly insulated mounted on insulatorscomplete with 4 No’s mounting legs made out of 50 mm x 50 mm x 6 mm angle iron grouted in PCC block of size 30 cm x 30 cm x 90 cm (30 cm depth below ground level and 60 cm above ground level) in cement concrete 1:3:6, type C-2 (using 40 mm grade crushed stone aggregate), andconnections with size of aluminium thimbles, nuts, bolts & washers including cable glands at entry and outlet points including excavation and earth work, returning filling and removal of surplus soils, powder coated with 7 tank processincluding taking out old unserviceable bus bar chamber complete all as specified and directed by Engr-in-charge .as per site requirement with the following :- (a) Bus bar electrolytic grade copper 400 amps 4 pole two set not less than 30 cm long each connected through HRC fuse arrangement of suitable capacity natural link and supported on Non-hygroscopic, non carbonising, corrosion resistance SMC insulator 400 Amp,4 pole, not less then 60 CM long mounted on insulators for incoming supply - 1 Set (Set of 4 strips) (b) Phase indicator lamp RYB LED type -01 Set (c) C.T"s of suitable ratio(Set of three) (d) Red,Yellow,Green Phase indicating Lights LED type 220V AC- 01 Set. (Set of three). (e)Incoming:- MCCB 250 amps , 36 KA 4 pole, Ics= 100% of Icu, adjustable type Qty- 01 No (f) Outgoing:-(i) MCCB 200 amps , 36 KA 4 pole, Ics= 100% of Icu, adjustable type Qty- 01 No (ii) MCCB 100 amps , 16 KA 4 pole, Ics= 100% of Icu, adjustable type Qty- 01 No Note:- The panel manufacturer should have following Govt. Approved Certificates: 1.Panel shall be installed at least 60 cm above ground 2.All civil/electrical work & material is deemed to be included in the quoted rates 3.Drawing of Lt feeder panel shall be got approved from GE.
35M&L Earthing complete as per electrical plate No 3 of MES SSR Part I with galvanised steel plate earth electrode 60 cm x 60 cm x 6.0mm, burried directly vertically in ground in a pit of depth not less than 2.5 metres below ground level with the top edge of earth plate at a depth not less than 1.5 m below normal ground level, connected to galvanisediron or steel strip 25x4 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel. Earthing wire protected by galvanised iron or steel pipe 50 mm bore medium grade and connected to continuous earth wire on pole/ test point.Watering pipe shall be 20mm bore GI medium grade. The earthing shall be inclusive ofexcavation and earth work in any type of soil,charcoal, salt,funnel , PCC pit and RCC cover complete all as specified & directed by Engr-in-Charge. Note 1- following items deemed to be included in quoted rate (a) Earth electrode. (b) Main earthing lead from earth electrode to test point and further to equipment to be earthed upto 7.5 metre. (c) Material and labourfor connecting earth electrode and earthing lead as specified. (d) Adequate quantity of charcoal dust and common salt as per direction. (e) All labour involved including testing of earth net work. (f) Excavation and earth work or drilling hole for electrode. (g) P.C.C. pit and C.I. cover. (h) Funnel with watering pipe, wire mesh and copper lugs etc. as specified. (j) G.I. protection pipe of size ordered specified for protection of earthing lead from mechanical injury or tempering. Note 2 - On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost.
36M&L Earthing complete as per electrical plate No 3 of MES SSR Part I with galvanised steel plate earth electrode 60 cm x 60 cm x 6.0mm, burried directly vertically in ground in a pit of depth not less than 2.5 metres below ground level with the top edge of earth plate at a depth not less than 1.5 m below normal ground level connected to and including galvanised iron or steel earth strip 32 x 6 mmby means of bolts, nuts, check nuts and washers of galvanised iron or steel. Earthing wire protected by galvanised iron or steel pipe 50 mm bore medium grade and connected to continuous earth wire on pole/ test point.Watering pipe shall be 20mm bore GI medium grade. The earthing shall be inclusive ofexcavation and earth work in any type of soil,charcoal, salt,funnel , PCC pit and RCC cover complete all as specified & directed. Note 1- following items deemed to be included in quoted rate (a) Earth electrode. (b) Main earthing lead from earth electrode to test point and further to equipment to be earthed upto 7.5 metre. (c) Material and labourfor connecting earth electrode and earthing lead as specified. (d) Adequate quantity of charcoal dust and common salt as per direction. (e) All labour involved including testing of earth net work. (f) Excavation and earth work or drilling hole for electrode. (g) P.C.C. pit and C.I. cover. (h) Funnel with watering pipe, wire mesh and copper lugs etc. as specified. (j) G.I. protection pipe of size ordered specified for protection of earthing lead from mechanical injury or tempering. Note 2 - On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost.