Tender For Repair/Maintenance Of Internal Wiring Dbs And Fitting Fixtures Including Day To Day Maintenance At Otm Accommodation In The Area Of Age Br-Ii Under Garrison Engineer Amritsar Cantt, amritsar-Punjab

Military Engineer Services-MES has published Tender For Repair/Maintenance Of Internal Wiring Dbs And Fitting Fixtures Including Day To Day Maintenance At Otm Accommodation In The Area Of Age Br-Ii Under Garrison Engineer Amritsar Cantt. Submission Date for this Tender is 15-05-2024. Electrification Work Tenders in amritsar Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

43233424
Corrigendum : Tender For Repair/Maintenance Of Internal Wiring Dbs And Fitting Fixtures Including Day To Day Maintenance At Otm Accommodation In The Area Of Age Br-Ii Under Garrison Engineer Amritsar Cantt
Open Tender
Indian
Punjab
amritsar
15-05-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Tender For Repair/Maintenance Of Internal Wiring Dbs And Fitting Fixtures Including Day To Day Maintenance At Otm Accommodation In The Area Of Age Br-Ii Under Garrison Engineer Amritsar Cantt

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 03-May-2024 Corrigendum NO 01 BOQ 15-05-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 90000.0 /-
Tender Value
INR 45 Lakhs /-

Attachment

FileName File Description File Size
65d3da63-9982-4b94-9458-0bccb7d537af.html Tender Notice 0 KB
BOQ_728762.xls Tender Document 0 KB
TENDER07.pdf Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

NAME OF WORK: REPAIR/MAINTENANCE OF INTERNAL WIRING DB’S & FITTING FIXTURES INCLUDING DAY TO DAY MAINTENANCE WORK TO OTM ACCN IN THE AREA OF AGE B/R-II UNDER GARRISON ENGINEER AMRITSAR CANTT.
Sl. No. Item Description
1Taking down carefully copper / aluminium point wiring (light, fan, socket or power) complete with fittings such as switches, ceiling roses, pendants, sockets, lamp holders, bracketsetc. and making good disturbed surfaces of walls etc. as per existing finishes by plastering, repairs and white / colour wash etc. ; Complete all as specified and directed by Engineer-in-charge.
2Material and Labour for Point wiring for One light / Onefan / One bell point controlled by one, one way switch.with 1.5 sqmm, PVC insulated but sheathed, stranded copper conductor single core FRLS cable, IS-694 marked, drawn through anexisting metallic/ rigid PVC concealed conduit including replacement of pressed steel terminalmounting boxfor mounting fittinglikeswitches, sockets, and provinding covered with3mm thick plastic laminated bakelite sheet cover fixed with brass screws and cup washers with & including one continuous run of PVC insulated but sheathed, stranded copper conductor single core FRLS cable, IS-694 marked (green colour) of 1.50 sqmm sizeas a earth wire and connected to common earth dolly; Complete all as specified and directed by the Engineer-in-charge.
3Material and Labour for Point wiring for One socket outet point 5 amps on the same boardpoint controlled by one, one way switch.with 1.5 sqmm, PVC insulated but sheathed, stranded copper conductor single core FRLS cable, IS-694 marked, drawn through anexisting metallic/ rigid PVC concealed conduit including replacement of pressed steel terminalmounting boxfor mounting fittinglikeswitches, sockets, and provinding covered with3mm thick plastic laminated bakelite sheet cover fixed with brass screws and cup washers with & including one continuous run of PVC insulated but sheathed, stranded copper conductor single core FRLS cable, IS-694 marked (green colour) of 1.50 sqmm sizeas a earth wire and connected to common earth dolly; Complete all as specified and directed by the Engineer-in-charge.
4Material and Labour for Point wiring for One socket outlet 5 pin 5 Amp controlled by one, one way switch on independentboardcontrolled by one, one way switch.with 1.5 sqmm, PVC insulated but sheathed, stranded copper conductor single core FRLS cable, IS-694 marked, drawn through anexisting metallic/ rigid PVC concealed conduit including replacement of pressed steel terminalmounting boxfor mounting fittinglikeswitches, sockets, and provinding covered with3mm thick plastic laminated bakelite sheet cover fixed with brass screws and cup washers with & including one continuous run of PVC insulated but sheathed, stranded copper conductor single core FRLS cable, IS-694 marked (green colour) of 1.50 sqmm sizeas a earth wire and connected to common earth dolly; Complete all as specified and directed by the Engineer-in-charge.
5Material and Labour for Point wiring for One socket outlet 16 Amps 6 pin controlled by one, one way switch on independentboardcontrolled by one, one way switch.with 2.5 sqmm, PVC insulated but sheathed, stranded copper conductor single core FRLS cable, IS-694 marked, drawn through anexisting metallic/ rigid PVC concealed conduit including replacement of pressed steel terminalmounting boxfor mounting fittinglikeswitches, sockets, and provinding covered with 3mm thick plastic laminated bakelite sheet cover fixed with brass screws and cup washers with & including one continuous run of PVC insulated but sheathed, stranded copper conductor single core FRLS cable, IS-694 marked (green colour) of 2.50 sqmm sizeas a earth wire and connected to common earth dolly; Complete all as specified and directed by the Engineer-in-charge.
6Material and Labour for point wiring for one light point / fan point / bell point (independent point), controlled by one, one way switch with1.50 sqmm size PVC insulated unsheathed 1100 volts grade single core (multi-stranded) copper conductor cable (FR) drawn into and including medium grade PVC conduit concealed (not less than 20 mm dia) all necessary fittings and accessories fixed concealed (including chase cutting in brick/stone masonery wall for fixing conduit and plastering the external surfaces and matching the same with existing suface)and sunk cast ironor pressed steel terminal boxes for mounting fittinglike switches, sockets, lamp holders, sketch fittings and covered with 3 mm thick plastic laminated bakelite sheet cover fixed with brass screws and cup washers including one continuous run of PVC insulated 1.50 sqmm sizecopper conductor cable as in earth wire and connected to common earth dolly; Complete all as specified and directed by Engineer-in-charge.
7Material and Labour for point wiring for One socket outet point 5 amps on the same board , controlled by one, one way switch with1.50sqmm size PVC insulated unsheathed 1100 volts grade single core (multi-stranded) copper conductor cable (FR) drawn into and including medium grade PVC conduit concealed (not less than 20 mm dia) all necessary fittings and accessories fixed concealed (including chase cutting in brick/stone masonery wall for fixing conduit and plastering the external surfaces and matching the same with existing suface)and sunk cast ironor pressed steel terminal boxes for mounting fittinglike switches, sockets, lamp holders, sketch fittings and covered with 3 mm thick plastic laminated bakelite sheet cover fixed with brass screws and cup washers including one continuous run of PVC insulated 1.50 sqmm sizecopper conductor cable as in earth wire and connected to common earth dolly; Complete all as specified and directed by Engineer-in-charge.
8Material and Labour for point wiring for One socket outlet 5 pin 5 Amp controlled by one, one way switch on independentboard (independent point), controlled by one, one way switch with 1.50 sqmm size PVC insulated unsheathed 1100 volts grade single core (multi-stranded) copper conductor cable (FR) drawn into and including medium grade PVC conduit concealed (not less than 20 mm dia) all necessary fittings and accessories fixed concealed (including chase cutting in brick/stone masonery wall for fixing conduit and plastering the external surfaces and matching the same with existing suface)and sunk cast ironor pressed steel terminal boxes for mounting fittinglike switches, sockets, lamp holders, sketch fittings and covered with 3 mm thick plastic laminated bakelite sheet cover fixed with brass screws and cup washers including one continuous run of PVC insulated 1.50 sqmm sizecopper conductor cable as in earth wire and connected to common earth dolly; Complete all as specified and directed by Engineer-in-charge.
9Material and Labour for point wiring for One socket outlet 6pin 16Amp controlled by one, one way switch on independentboard (independent point), controlled by one, one way switch with 2.50sqmm size PVC insulated unsheathed 1100 volts grade single core (multi-stranded) copper conductor cable (FR) drawn into and including medium grade PVC conduit concealed (not less than 20 mm dia) all necessary fittings and accessories fixed concealed (including chase cutting in brick/stone masonery wall for fixing conduit and plastering the external surfaces and matching the same with existing suface)and sunk cast ironor pressed steel terminal boxes for mounting fittinglike switches, sockets, lamp holders, sketch fittings and covered with 3mm thick plastic laminated bakelite sheet cover fixed with brass screws and cup washers including one continuous run of PVC insulated 2.50sqmm sizecopper conductor cable as in earth wire and connected to common earth dolly; Complete all as specified and directed by Engineer-in-charge.
10Material and Labour for point wiring for One light/one fan/one bell point controlled by one, one way switch on independentboard (independent point) for modular fittings with 1.50sqmm size PVC insulated unsheathed 1100 volts grade single core (multi-stranded) copper conductor cable (FR) drawn through anexisting metallic/ rigid PVC concealed conduit including replacement of Metal boxes and modular accessories like cover platesfor mounting fittinglikemodular switches, modular sockets,modular fittings andbrass screws and cup washers including 1.5 sqmm stranded copper conductor PVC insulated FRLS cable green in colour as continuous earth conductor connected to common earth and earth dolly with all accessories ; Complete all as specified and directed by Engineer-in-charge.
11Material and Labour for point wiring for One modular socket outet point 5 amps on the same board controlled by one, one way switch for modular fittings with 1.50sqmm size PVC insulated unsheathed 1100 volts grade single core (multi-stranded) copper conductor cable (FR) drawn through anexisting metallic/ rigid PVC concealed conduit including replacement of Metal boxes and modular accessories like cover platesfor mounting fittinglikemodular switches, modular sockets,modular fittings andbrass screws and cup washers including 1.5 sqmm stranded copper conductor PVC insulated FRLS cable green in colour as continuous earth conductor connected to common earth and earth dolly with all accessories ; Complete all as specified and directed by Engineer-in-charge.
12Material and Labour for point wiring for One modular socket outlet5 pin 5Amp controlled by one, one way switch on independentboard controlled by one, one way switch for modular fittings with 1.50sqmm size PVC insulated unsheathed 1100 volts grade single core (multi-stranded) copper conductor cable (FR) drawn through anexisting metallic/ rigid PVC concealed conduit including replacement of Metal boxes and modular accessories like cover platesfor mounting fittinglikemodular switches, modular sockets,modular fittings andbrass screws and cup washers including 1.5 sqmm stranded copper conductor PVC insulated FRLS cable green in colour as continuous earth conductor connected to common earth and earth dolly with all accessories ; Complete all as specified and directed by Engineer-in-charge.
13Material and Labour for point wiring for One modular socket outlet 3 Pin , 16Amps controlled by one, one way switch on independentboard controlled by one, one way switch for modular fittings with 1.50sqmm size PVC insulated unsheathed 1100 volts grade single core (multi-stranded) copper conductor cable (FR) drawn through anexisting metallic/ rigid PVC concealed conduit including replacement of Metal boxes and modular accessories like cover platesfor mounting fittinglikemodular switches, modular sockets,modular fittings andbrass screws and cup washers including 2.5 sqmm stranded copper conductor PVC insulated FRLS cable green in colour as continuous earth conductor connected to common earth and earth dolly with all accessories ; Complete all as specified and directed by Engineer-in-charge. All as Ser item 12 here in before but with 2.5 sq mm wire and earth wire (green colour) of 2.5 sq mm for 3 Pin 15 Amp modular type socket outlet.
14Material and Labour for point wiring for one modularlight point / fan point / bell point (independent point), controlled by one, one way modular switch with1.50 sqmm size PVC insulated unsheathed 1100 volts grade single core (multi-stranded) copper conductor cable (FR) drawn into and including medium grade PVC conduit concealed (not less than 25 mm dia) all necessary fittings and accessories fixed concealed (including chase cutting in brick/stone masonery wall for fixing conduit and plastering the external surfaces and matching the same with existing suface)and metal terminal boxes for mounting fittinglike modular switches, modular sockets, lamp holders, sketch fittings and covered with modular cover platefixedincluding one continuous run of PVC insulated 1.50 sqmm sizecopper conductor cable as in earth wire and connected to common earth dolly; Complete all as specified and directed by Engineer-in-charge.
15Material and Labour for point wiring for One modular socket outet point 5 amps on the same board, controlled by one, one way modular switch with1.50 sqmm size PVC insulated unsheathed 1100 volts grade single core (multi-stranded) copper conductor cable (FR) drawn into and including medium grade PVC conduit concealed (not less than 25 mm dia) all necessary fittings and accessories fixed concealed (including chase cutting in brick/stone masonery wall for fixing conduit and plastering the external surfaces and matching the same with existing suface)and including metal terminal boxes for mounting fittinglike modular switches, modular sockets, lamp holders, sketch fittings and covered with modular cover platefixedincluding one continuous run of PVC insulated 1.50 sqmm sizecopper conductor cable as in earth wire and connected to common earth dolly; Complete all as specified and directed by Engineer-in-charge.
16Material and Labour for point wiring for One modular socket outet point 5 amps 3 pin on the independent board, controlled by one, one way modular switch with1.50 sqmm size PVC insulated unsheathed 1100 volts grade single core (multi-stranded) copper conductor cable (FR) drawn into and including medium grade PVC conduit concealed (not less than 25 mm dia) all necessary fittings and accessories fixed concealed (including chase cutting in brick/stone masonery wall for fixing conduit and plastering the external surfaces and matching the same with existing suface)and including metal terminal boxes for mounting fittinglike modular switches, modular sockets, lamp holders, sketch fittings and covered with modular cover platefixedincluding one continuous run of PVC insulated 1.50 sqmm sizecopper conductor cable as in earth wire and connected to common earth dolly; Complete all as specified and directed by Engineer-in-charge.
17Material and Labour for point wiring for One modular socket outet point 16amps 3 pin on the independent board, controlled by one, one way modular switch with2.50 sqmm size PVC insulated unsheathed 1100 volts grade single core (multi-stranded) copper conductor cable (FR) drawn into and including medium grade PVC conduit concealed (not less than 25 mm dia) all necessary fittings and accessories fixed concealed (including chase cutting in brick/stone masonery wall for fixing conduit and plastering the external surfaces and matching the same with existing suface)and including metal terminal boxes for mounting fittinglike modular switches, modular sockets, lamp holders, sketch fittings and covered with modular cover platefixedincluding one continuous run of PVC insulated 2.50 sqmm sizecopper conductor cable as in earth wire and connected to common earth dolly; Complete all as specified and directed by Engineer-in-charge.
18Supply and fixingswitch piano flush button single pole one-way 5 Ampere; Complete all as specified and directed by Engineer-in-charge.
19Supply and fixing of socket outlet 5 Ampere, 2 and 3 pins (TOTAL 05 PINS), flush type 250 volts AC; Complete all as specified and directed by Engineer-in-charge.
20Supply and fixing of switch piano flush button single pole one-way 15 Ampere; Complete all as specified and directed by Engineer-in-charge.
21Supply and fixing of socket outlet two-in-one, 3 pin each suitable for 5 and 15 Amperes flush type, 250 volts AC; Complete all as specified and directed by Engineer-in-charge.
22Supply and Fixing Modular switch 6 Amp 1 way 1 module size; Complete all as specified and directed by Engineer-in-charge.
23Supply and Fixing Modular switch 16 Amp 1 way with indicator 1 module size ; Complete all as specified and directed by Engineer-in-charge.
24Supply and Fixing Modular socket shuttered 6 Amp 2/3 pin combined2 module size; Complete all as specified and directed by Engineer-in-charge.
25Supply and Fixing Modular socket 16Amp multipurpose type 2 module size ; Complete all as specified and directed by Engineer-in-charge.
26Supply and Fixing Modular Fan regulator step type 120 watts 2 Module size; Complete all as specified and directed by Engineer-in-charge.
27Supply and Fixing Ceiling rose, surfacebakelite 3 terminal, 240 volts, 5 Amps with back plate of 3 mm thickbakelite, laminated hylem sheet of appropriate size; Complete all as specified and directed by Engineer-in-charge.
28Supply and Fixing lamp holder, PVC / polycarbonate type insulated body with back plate suitable for batten / angle fittings; Complete all as specified and directed by Engineer-in-charge.
29Supply and fixing of single phase call bell ‘DING DONG’, AC 230 volts single pole fixed over and including pressed steel sunk box of size 175 X 100 mm duly covered with 3 mm thick bakelite sheet ; Complete all as specified and directed by Engineer-in-charge.
30Supply and Fixing bell push, flush type, single pole 5 amps; Complete all as specified and directed by Engineer-in-charge.
31Supply and Fixing in repairs metal enclosure (plug & socket type DB) complete including double pole enclosure with two pin, earth plug and socket complete with one SP MCB C Curve type of capacity 20 Amp, 10 KA; Complete all as specified and directed by Engineer-in-charge.
32Supply and Fixing in repairs MCB single pole, 240 volts, 6 to 32 Ampere, rupturing capacity 10 KA, ‘C’ curve type; Complete all as specified and directed by Engineer-in-charge.
33Supply and Fixing in repairsMCB double pole, 240 volts, 40 to 63 Ampere, rupturing capacity 10 KA, ‘C’ curve type; Complete all as specified and directed by Engineer-in-charge.
34Supply and Fixing in repairsMCB double pole higher rating, 240 volts,100 Ampere, rupturing capacity 10 KA, ‘C’ curve type; Complete all as specified and directed by Engineer-in-charge.
35Supply and Fixing in repairssheet metal enclosure for DB’s (Double door type) when MCB’s to be used, single pole and neutral, 4 ways with 200 ampere rated bus bar, 240 volts fixed sunk / flush to the wall; Complete all as specified and directed by Engineer-in-charge.
36Supply and Fixing in repairssheet metal enclosure for DB’s (Double door type) when MCB’s to be used, single pole and neutral, 8 ways with 200 ampere rated bus bar, 240 volts fixed sunk / flush to the wallwith IP-43 and IK-09 protection; Complete all as specified and directed by Engineer-in-charge.
37Supply and Fixing in repairsDistribution Boarddouble Doormade out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coatingsurface mounting SPN 12 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s and isolators etc; Complete all as specified and directed by Engineer-in-charge. (Note : cost of removing old wooden box and making good of surface as original by brick work, plastering, whitewash/colour/distemper etc is included in quated rate)
38Supply and Fixing in repairsMCCB Incomer distribution board double door vertical type made out of CRCA MS sheet surface with insulated material like polyester or with epoxy powder coating surface mounting TPN 4 way, 415 volts with copper bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCCBwith and incl 100 amp 25 kA 4 pole MCCB with thermal - magnetic setting including Suitable type MCB with blank plateincluding taking down old MCCB all as specified and directed ; Complete all as specified and directed by Engineer-in-charge. (Note : The cost of removing old wooden/steel box etc and making good of surface as original by brick work, plastering, whitewash/colour/distemper etc is included in quated rate)
39Material and Labour for sub main wiring with 1100 volt grade two single core FRLSH Wire PVC insulated and unsheathed cable with stranded copper conductor 6 sqmm drawn into and including electrical grade PVC conduit medium grade not less than 25 mm dia with IS 9537 (Part-III) 1983 mark, or relevant ISI mark with all accessories fixed concealed including chase cutting in brick/ stone masonry for fixing conduit and making good the disturb surfaces of wall as per existing including 6 sqmm multi - stranded copper conductor as earth wire in green colour including taking down old unserviceable sub main wiring; Complete all as specified and directed by Engineer-in-charge. NOTE: 3 single core 6 sqmm and PVC conduit shall be measured as one RM.
40Material and Labour for sub main wiring with 1100 volt grade two single core FR Wire PVC insulated and unsheathed cable with stranded copper conductor 10 sqmm drawn into and including electrical grade PVC conduit not less than 25 mm dia with IS 9537 (Part-III) 1983 mark medium grade FRLS, or relevant ISI mark with all accessories fixed concealed including chase cutting in brick/ stone masonry for fixing conduit and making good the disturb surfaces of wall as per existing including 10 sqmm multi - stranded copper conductor as earth wire in green colourIncluding taking down old unserviceable sub main wiring; Complete all as specified and directed by Engineer-in-charge. NOTE: 3 single core 10 sqmm and PVC conduit shall be measured as one RM.
41Material and Labour for sub main wiring with 1100 volt grade two single core FR Wire PVC insulated and unsheathed cable with stranded copper conductor 16 sqmm drawn into and including electrical grade PVC conduit not less than 25 mm dia with IS 9537 (Part-III) 1983 mark medium grade FRLS, or relevant ISI mark with all accessories fixed concealed including chase cutting in brick/ stone masonry for fixing conduit and making good the disturb surfaces of wall as per existing including 16 sqmm multi - stranded copper conductor as earth wire in green colour including taking down old unserviceable sub main wiring; Complete all as specified and directed by Engineer-in-charge. NOTE: 3 single core 16 sqmm and PVC conduit shall be measured as one RM.
42Material and Labour for sub main wiring with 1100 volt grade two single core FR Wire PVC insulated and unsheathed cable with stranded copper conductor 4 sqmm drawn into and including electrical grade PVC conduit not less than 25 mm dia with IS 9537 (Part-III) 1983 mark medium grade FRLS, or relevant ISI mark with all accessories fixed concealed including chase cutting in brick/ stone masonry for fixing conduit and making good the disturb surfaces of wall as per existing including 4 sqmm multi - stranded copper conductor as earth wire in green colour including taking down old unserviceable sub main wiring; Complete all as specified and directed by Engineer-in-charge. NOTE: 2 run of 4 sqmm & 1 run of 4 sqmm as earth wireand PVC conduit shall be measured as one RM.
43Supply and Fixing wall /ceiling mounting LED 18 Watt pride plus/smart line tube light fitting complete withall acessories 1x18 Watt LED , with CCT of 6000k suitable for domestic application, 240 Volts, 50 Hz, and internally pre-wired with 1.5 sqmm twin twisted flexible cable copper conductor and connection; Complete all as specified and directed by Engineer-in-charge.
44Supply and Fixingin repairs wall /ceiling mounting LED 9 Watt tube light fitting complete withall acessories 1x9 Watt LED ,with CCT of 6000k suitable for domestic application, 240 Volts, 50 Hz,and internally pre-wired with 1.5 sqmm twin twisted flexible cable copper conductor and connection; Complete all as specified and directed by Engineer-in-charge.
45Supply and Fixing in repairsdecorative Gate light fitting made up of high grade unbreakable polycarbonate material suitablefor 9 watt LED lamp (B-22 base) including one Nos LED bulb 9 watt with; Complete all as specified and directed by Engineer-in-charge.
46Supply and Fixing in repairsenergy saving new generation 10 watt LED built up, 6000kbulk head luminaire with opal diffuser light fitting complete with all acessories and connection; Complete all as specified and directed by Engineer-in-charge.
47Supply and Fixing in repairsfan regulator electronic step t& socket size and making all necessary connections; Complete all as specified and directed by Engineer-in-charge.
48Material and Labour as in repairsfor earthing complete with galvanised earth plate electrode 600 X 600 X 6 mm thick buried directly in ground (earth pit not less than 2.25 m below ground level) with top edge of earth plate not less than 1.5 m below normal ground level, connected to galvanised earth lead wire 4 mm dia by means of nuts, bolts, check nuts & washers of galvanised iron or steel all as shown on electrical plate No. 3 of MES schedule 2009, Part – I (Specifications) and connected to main switch board / main DB’s / earthing test point including all necessary excavation and earth work in any type of soil, adequate quantity of charcoal dust & common salt all around the earth plate minimum 150 mm in all directions with & including watering pipe 20 mm dia GI medium grade, GI funnel made out of 0.63 mm thick GI sheet, wire gauge, 50 mm thick RCC cover in PCC 1:2:4, type B-1, duly reinforced with 6 mm dia mild steel round bars @ 150 mm both ways center to center with suitable lifting handle to cover, earth pit of PCC 1:3:6 type C-1, GI protection pipe light grade 15 mm bore up to 7.5 m length from earth electrode & engraving of earth marking on nearby building with CM 1:4 plate size 200 X 150 X 15 mm & painting of earth result etc. including testing on; Complete all as specified and directed by Engineer-in-charge. Note: - (i) Earth lead and protection pipe beyond 7.5 m shall be measured and Paid separately. (ii) On testing after completion of job, if desired earth resistance is not obtained, the earthing shall be redone by the contractor without any extra cost to Govt. (iii) Earthing work will be done by contractor ub presence of JE /Engr-in-Charge, the earthing work carried in absence JE /Engr-in-Charge will not neasured & paid for the same. (iv) All earthing material will be approved before bulk procurement and got approved from Engr-in-Charge
49Supply and Fixingin repairs ceiling mounting fitting LED type 36 W fitted in 2x2 ceiling including PVC wire upto 1.5 mtr from ceiling rose to fitting; Complete all as specified and directed by Engineer-in-charge.
50Material and labour in repairs service connection PVC cable 10 Sqmm 2 Core incl GI wire and PVC conduit for fixing in wall /pole incl connection; Complete all as specified and directed by Engineer-in-charge.
51Supply and Fixing in repairsLED flood light fitting 50 Watt with high pressure die cast housing IP65 protection single phase supply including connection with PVC wire; Complete all as specified and directed by Engineer-in-charge.
52Supply and Fixing in repairspost top lantern LED fitting 15 Watt including LED bulb high grade unbreakable polycarbonate suitable for LED bulb including connection with PVC wire; Complete all as specified and directed by Engineer-in-charge.
53Supply and Fixing in repairsbell push, Module type, single pole 5 amps complete; Complete all as specified and directed by Engineer-in-charge.
54Supply and Fixing in repairsLED Blub 9 Watt pin type 220 Volts including connection; Complete all as specified and directed by Engineer-in-charge.
55Supply and Fixing in repairsCeiling light fitting 12 Watt as per sample including connection; Complete all as specified and directed by Engineer-in-charge.
56Supply and Fixing in repairsLED Blub Thread 9 Watt threat type 220 Volts including connection; Complete all as specified and directed by Engineer-in-charge.