| 1 | SITC of Modular boxwith cover plate:2 Modular/ 3 Modular/4 Modular- as per specification document TS 01. |
| 2 | SITC of Modular box with cover plate :6 Modular as per specification document TS 01. |
| 3 | SITC of Modular box with cover plate:8 Modular as per specification document TS 01. |
| 4 | SITC of Modular boxwith cover plate :12 Modular as per specification document TS 01. |
| 5 | SITC of6 A , One way Switch as per Specification document TS 01. |
| 6 | SITC of 16A One WaySwitch with Indication as per Specification document TS 01. |
| 7 | SITC of 2 Module ceiling fan regulator-120 Was per Specification document TS 01. |
| 8 | SITC of 20 AOne Way DP Switch with Indication as per Specification document TS 01. |
| 9 | SITC of Ceiling Rosesas per Specification document TS 01. |
| 10 | SITC of Flexible PVC Conduitas per Specification document TS 01. |
| 11 | SITC of25 mm Width Casing capingas per Specification document TS 01. |
| 12 | SITC of 6/16A 3-pin Socketas per Specification document TS 01. |
| 13 | SITC of 25 A socketas per Specification document TS 01. |
| 14 | SITC of 10 A / 16 A SP MCBas per Specification document TS 01. |
| 15 | SITC of 25 A SP MCBas per Specification document TS 01. |
| 16 | SITC of 63 A FP MCBas per Specification document TS 01. |
| 17 | SITC of 63 A DP RCCB-30mAas per Specification document TS 01. |
| 18 | SITC of 40 A DP MCBas per Specification document TS 01. |
| 19 | SITC of 40 A DP RCCB-30mAas per Specification document TS 01. |
| 20 | SITC of 4 kV, 40 kAType 2 Surge diverter as per Specification document TS 01. |
| 21 | SITC of Incomer Point Wiring - 6 Sq. mm size FRLS Wire as per Specification document TS 01. |
| 22 | SITC of AC Point Wiringas per Specification document TS 01. |
| 23 | SITC of Primary Power Point Wiringas per Specification document TS 01. |
| 24 | SITC of Secondary power point wiring ( Located in a separate box)as per Specification document TS 01. |
| 25 | SITC of Primary Light/Fan Point Wiringas per Specification document TS 01. |
| 26 | SITC of Secondary Light point wiringas per Specification document TS 01. |
| 27 | SITC of 1200mm Dia Ceiling fan including down rod and safety wire as per Specification document TS 03. |
| 28 | SITC of Exhaust Fan ( PVC Body with Louver) 200 mm Sweepas per Specification document TS 04. |
| 29 | SITC of Exhaust Fan ( MetalicBody with Louver) 450 mm Sweepas per Specification document TS 05. |
| 30 | SITC of Indoor LEDlight fixture Min 2500 Lumen as per Specification document TS 06 |
| 31 | SITC of Surface Mount Round LightMin 1200 Lumen as per Specification document TS 07. |
| 32 | SITC of RecessedRound Light Min 1500 Lumenas per Specification document TS 08. |
| 33 | SITC of 10 W LED, Min 1000 LumensSurface mounted mirror light fixtureas per Specification document TS 09. |
| 34 | SITC of 70W, Min 7000 lumen Outdoor light as per Specification TS 09-OL. |
| 35 | SITC of 1100 V grade 4 corex 16 sq.mm PVC insulated strip/Roundarmoured cable with Copper conductoras per Specification document no. TS 10. |
| 36 | SITC of 1100 V grade 4 corex 25 sq.mm PVC insulated strip/Roundarmoured cable with Copper conductoras per Specification document no. TS 10. |
| 37 | End terminations of LT Cable: 4 C X 16 Sq. mm / 4 C X 25 Sq. mm Copper conductor as per Specification document no. TS 11. |
| 38 | Brick Protection of LT cableas per Specification document No. TS 12 |
| 39 | Cable Route Marker as per Specification dcoument No. TS 13 |
| 40 | Copper Earth pit as per specification and drawing document No. TS 14 |
| 41 | Lightning Protection System: Cross units for (500mm/1000mm air terminal) with intermediate plate for round and flat cond. up to 40 mm, Cross unit for aboveground and underground connections, For connecting conductors in cross and T arrangement, Material of clamp: St/tZn, Clamping range Rd / Fl: 8-10 / 30-40 mm. Intermediate plate: yes along with Conductor of Diameter Ø- 8 mm for (500mm air terminal) Cross-section- 50 mm2, of Material- Aluminium. The Terminal shall be provided with concrete base of 17 kg and plastic support for concrete base 17 kg. Necessary U-bolt clamps,cross unit, flat strip holder etc. are also included in the scope of this item. Model Similar to M/s DEHN or Equivalent. |
| 42 | Lightning Protection System: Air Terminal Unit of 2000 mm lengthwith intermediate plate for round and flat cond. up to 40 mm, Cross unit for aboveground and underground connections, For connecting conductors in cross and T arrangement, Material of clamp: St/tZn, Clamping range Rd / Fl: 8-10 / 30-40 mm. Intermediate plate: yes along with Conductor of Diameter Ø- 8 mm for (500mm air terminal) Cross-section- 50 mm2, of Material- Aluminium. The Terminal shall be provided with concrete base of 17 kg and plastic support for concrete base 17 kg. Necessary U-bolt clamps,cross unit, flat strip holder etc. are also included in the scope of this item. Model Similar to M/s DEHN or Equivalent. |
| 43 | Supply and installation of 25 X 3 mm GI Strip Conductor for Lightning/earthing conductor.Cross units without intermediate plate for two flat conductors-Cross unit for aboveground and underground connections. Material: Zinc. Necessary U-bolt clamps,cross unit, flat strip holder etc. are also included in the scope of this item. Flat strip holder with cleat, flat design, with slot, St/tZn at every 1mtr interval. Strip holder with cleat - flat design, Twin screw cleat with M6 screws, Height of conductor holder: 10 mm. Conductor holder support Fl: 30 x 3.5 mm. Material of conductor holder: St/tZnMaterial thickness: 3 mm. GI strip holder of material- Dow moulded compound, having height- 19mm, Slot Size- 25x6 mm shall also be included in this item. Model Similar to M/s DEHN or Equivalent. |
| 44 | Supply, Installation, Testing and Commissioning of Test Links |
| 45 | Supply , Installation , testing and commissioning of Earth electrode with MS Rod ( maintenance free earthing ) for earthing Pit for Lightning arrestor grounding as per specification. |
| 46 | PCC Work as per Specification document No. TS 16 |
| 47 | Excavation and Back filling with disposal of excess earth as directed by Engineer-in-Charge as per Specification. |
| 48 | Providing and Fixing in position Suspended false ceiling system using 600x600mm Aerated Calcium Silicate Ceiling tiles (plain/ cosmos/ spinton model) Tiles having 15mm Densified edges as per Technical Specification document No. TS 17. |
| 49 | Providing and Fixing in position Suspended false ceiling system using 12mm thick Calcium Silicate Boards, 100% Humidity resistance, Incombustible as per BS476 part IV as per Technical Specific Document No. TS 18. |
| 50 | Supply, Installation , Testing & Commissioning of type NP2 150 mm Dia Hume Pipe as per Specification document No. TS 20. |
| 51 | Photo Luminiscent Signages for Toilet, Exit, Staircase, Lift etc.Board Thickness 3 mm as per Specification document No. TS 21 |
| 52 | SITC of Insect Killers as per Specification |