Repair Maintenance And Improvementof Lt Panel Including Lt Switch Gear, Earthing, Timer Panel, Lt Poles, Pole Box,Outdoor Street Lights, Flood Lights, Area Lights, Lt Distribution Network And Connected Items At 25 Weu, Receiver, Transmitter, Nirbhay Vihar, lucknow-Uttar Pradesh

Military Engineer Services-MES has published Repair Maintenance And Improvementof Lt Panel Including Lt Switch Gear, Earthing, Timer Panel, Lt Poles, Pole Box,Outdoor Street Lights, Flood Lights, Area Lights, Lt Distribution Network And Connected Items At 25 Weu, Receiver, Transmitter, Nirbhay Vihar. Submission Date for this Tender is 13-05-2024. Electrification Work Tenders in lucknow Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

43228274
Repair Maintenance And Improvementof Lt Panel Including Lt Switch Gear, Earthing, Timer Panel, Lt Poles, Pole Box,Outdoor Street Lights, Flood Lights, Area Lights, Lt Distribution Network And Connected Items At 25 Weu, Receiver, Transmitter, Nirbhay Vihar
Open Tender
Indian
Uttar Pradesh
lucknow
13-05-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Srepair Maintenance And Improvementof Lt Panel Including Lt Switch Gear, Earthing, Timer Panel, Lt Poles, Pole Box, Outdoor Street Lights, Flood Lights, Area Lights, Lt Distribution Network And Connected Items At 25 Weu, Receiver, Transmitter, Nirbhay Vihar And Adjoining Area Of Age E / M Ext ( Elect ) Under Ge E / M Lucknow

Key Value

Document Fees
INR 500 /-
EMD
INR 97000.0 /-
Tender Value
INR 48.50 Lakhs /-

Attachment

FileName File Description File Size
dd4c531f-13a0-48de-b247-3d40dd29bef0.html Tender Notice 0 KB
BOQ_728680.xls Tender Document 0 KB
Tender26.pdf Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

Name of Work: REPAIR MAINTENANCE AND IMPROVEMENTOF LT PANEL INCLUDING LT SWITCH GEAR, EARTHING, TIMER PANEL, LT POLES, POLE BOX,OUTDOOR STREET LIGHTS, FLOOD LIGHTS, AREA LIGHTS, LT DISTRIBUTION NETWORK AND CONNECTED ITEMS AT 25 WEU, RECEIVER, TRANSMITTER, NIRBHAY VIHAR AND ADJOINING AREA OF AGE E/M EXT (ELECT) UNDER GE E/M LUCKNOW
Sl. No. Item Description
1Excavation in trenches in soft / Loose soilnot exceeding 1.5 mtr deep and not exceeding 1.5 mtr wide and getting out complete all as specified and as directed by the Engineer-in-Charge.
2Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm thick complete all as specified and as directed.
3Removing excavated soil to a distance not exc 50 m and depositing where directed at level n exc 1.5 m above the starting point.
4M&L for providing dry river sand as in sand cushioning below and above cable thickness as specified in SSR to under ground cable including punning down of sand in layer all as specified and directed by Engg-in-Charge. Note: for measurement purpose punned thickness of sand will be consider.
5Supply and Laying of bricks well burnt sub class B (old size) laid flat for cable protection width equal to the length of bricks complete all as specified and directed by Engineer-in-Charge.
6Deployment of tools & manpower for Boring of hole under road / pavement / hard standing or any other situation by manual means suitable for passing of 40 to 80 mm bore pipe and making good both ends all specified and directed
7Supply, laying or fixing in replacement, jointing and testing LT under ground electric power cable crossed linked polyethylene (XLPE) insulated, galvanised steel strip or wire armoured,ISI-7098 marked, with aluminium conductor multi stranded, heavy duty 1100 Volts grade of size 10 Sqmm cross sectional area, 2 core, complete all as specified laid in trenches / laid under floor or fixed naked on walls / on poles / in ducts / in GI pipes etc. with and including MS Clamps, nuts, bolts, washers complete all as specified and directed. Note :-Excavation, earth work, sand cushioning, protection bricks / tiles / block and pipe shall be measured and paid separately under appropriate items.
8All as per Item No 07 but cable of size 16 Sqmm 4 core.
9All as per Item No 07 but cable of size 35 Sqmm 3.5 core.
10All as per Item No 07 but cable of size 50 Sqmm 3.5 core.
11All as per Item No 07 but cable of size 70 Sqmm 3.5 core.
12All as per Item No 07 but cable of size 95 Sqmm 3.5 core.
13All as per Item No 07 but cable of size 120 Sqmm 3.5 core.
14All as per Item No 07 but cable of size 240 Sqmm 3.5 core.
15M&L for 40 mm bore mild steel galvanised water tubing, light grade with all fittings and fixed to walls or laid onfloors / fixed to poles / or passing under road crossing, for protection of UG cable including taking down old GI pipe complete all as specified and directed by Engr-in-Charge.
16M&L for 50 mm bore mild steel galvanised water tubing, light grade with all fittings and fixed to walls or laid onfloors / fixed to poles / or passing under road crossing, for protection of UG cable including taking down old GI pipe complete all as specified and directed by Engr-in-Charge.
17M&L for 80 mm bore mild steel galvanised water tubing, light grade with all fittings and fixed to walls or laid onfloors / fixed to poles / or passing under road crossing, for protection of UG cable including taking down old GI pipe complete all as specified and directed by Engr-in-Charge.
18M&L for 100 mm bore mild steel galvanised water tubing, light grade with all fittings and fixed to walls or laid onfloors / fixed to poles / or passing under road crossing, for protection of UG cable including taking down old GI pipe complete all as specified and directed by Engr-in-Charge.
19M&L for cutting of PCC / Hard standing / WBM road not exceeding 20 cm in width not exceeding 30 cm in depth for passing of LT cable and making good of disturbed surface to with PCC 1:3:6 type C2 using 40 mm graded stone aggrigate to match with the existing surfaces complete all as specified and directed .
20S&F in replacementwheather proof pole mountingjunction box, base and door of junction boxmade out of SMC having outside dimention333 x 233 x 120 mm, inside dimention 300 x 200 x 105 mm, single door front openable provided withhinged cover and locking arrangements with 4 Nos aluminium bas bar 63 Amps, mounted on porcelin insulator including M&L for MCB SP10-1No, fixed on box in Din rail complete with electrical connection fixed to pole with suitable sizeFI clamp nut bolts and washer including embossing / painting of danger notice of size not less than 10 cm x 7.5 cm with letters, figures and conventional skull and bones in signal red colour on front face of junction box body complete all as directed by Engr-in-Charge.
21Supply and errectionin replacement05 mtr continuously tapered hot dip galvanised Octagonal cross sectional pole with single dipping method having bottom 130 mm A/F and top 70 mm A/F 3 mm thick confirming to ASTM A 572 Gr with yield 450mpa cut and folded to form an octagonal section and welded in accordance with AWS for wind loading as per IS 875 part 3 1987.Poles shall be provided with base plate of size 225x225x12 mm which shall be free from any lamination or incursion with no cutting or welding on the pole after hot dip galvanising with single arm 1000 mm long bracket tilted to 150 degree from horizontal toward vertices suitable for mounting on the octagonal pole, of company recommendationand one no TPN Connecton 3 phase 4 wire 100 Amps, and one number MCB SP 6 Amps. A triangular flat MS plat of 6mm thick duly coated with GI shall be welded between cap of the octagonal pole and bracket. Welding work shall be done 250mm on bracket and 150 mm on pole"s cap including all RCC work type (1:2:4) type B-1 including 04 Nos foundation nut bolt and plate as per pole manufacturer"s drawing and earth work all as per requirement complete all as specified and directed. Note Cost of construction of RCC foundation including construction material, necessary earth work and excavatonas per manufacturer design forabove polecompleteall as required at site and as directed by Engr-in-charge are deemed to be included in the quoted rate.
22Supply and errectionin replacement07 mtr continuously tapered hot dip galvanised Octagonal cross sectional pole with single dipping method having bottom 130 mm A/F and top 70 mm A/F 3 mm thick confirming to ASTM A 572 Gr with yield 450mpa cut and folded to form an octagonal section and welded in accordance with AWS for wind loading as per IS 875 part 3 1987.Poles shall be provided with base plate of size 225x225x12 mm which shall be free from any lamination or incursion with no cutting or welding on the pole after hot dip galvanising with single arm 1000 mm long bracket tilted to 150 degree from horizontal toward vertices suitable for mounting on the octagonal pole, of company recommendationand one no TPN Connecton 3 phase 4 wire 100 Amps, and one number MCB SP 6 Amps. A triangular flat MS plat of 6mm thick duly coated with GI shall be welded between cap of the octagonal pole and bracket. Welding work shall be done 250mm on bracket and 150 mm on pole"s cap including all RCC work type (1:2:4) type B-1 including 04 Nos foundation nut bolt and plate as per pole manufacturer"s drawing and earth work all as per requirement complete all as specified and directed. Note Cost of construction of RCC foundation including construction material, necessary earth work and excavatonas per manufacturer design forabove polecompleteall as required at site and as directed by Engr-in-charge are deemed to be included in the quoted rate.
23M&L for taking out LT electric pole 9 metre long, removing embadded portion, shifting / removing of same LT pole 9 mtr from one place to another places of entier Cantt area,refixing the pole including necessary excavation and earth work , PCC 1:4:8 type D2 in foundations below pole, PCC 1:3:6 type C2 around poles and PCC 1:3:6 type C1 as in plinth block, disposal of surplus soil to a distance not exceeding 50 m and depositing where directed.
24M&L for taking out LT electric Octagonal pole 5/7 mtr, removing from foundation, shifting / removing of same LT pole from one place to another places of entier Cantt area,refixing the pole including construction of RCC foundation with construction material, necessary earth work and excavaton, nut bolt, as per manufacturer design disposal of surplus soil to a distance not exceeding 50 m and depositing where directed.
25Material and labour for renewal of earthing complete with galvanized iron earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m deep below normal ground connected togalvanized steel strip of size 32 x 6 mm by means of bolts nuts check nuts and washer of galvanized steel, watering pipe of 20 mm bore, galvanised iron, medium grade, and 40 mm bore galvanised iron light grade for earth wire protectionincluding all excavation earth work in any type of soil, PCC pit in PCC 1:2:4 type B-1 and RCC 1:2:4, type B1 for precast chamber cover 50 mm thick, reinforced with welded steel wire fabric or XPM Jali (weight not less than 4.00 Kg / sqm),with charcoal, salt, funnel complete all as shown in the electrical plate No 3 of SSR part –I and testing on completion.
26Supply, installing, testing and commissioning in replacementfactory made, CPRI approved Timer panel board (Dimention of Cubical / enclosure not less than 600 mm x 450 mm x 450 mm), confirming to IS 5039, cubical compartmentalized, out door type, double door, plate form mounted, suitable for 415 volts, 3 phase, 4 wire, 50 HzAC supply system, having bus bar chamber with insulated aluminium bus bars four pole installed on porcelain / SMC insulator. The timerpanel shall be dust and vermin proofIP-54 class protection, outer shell made of of 3.15 mm CRCA sheet, inner shell made of 2.0 mm thick CRCA sheet, 40 x 40 x 6 mm thick MS angle iron frame work, the cubical have bottom support of angle iron 50 x 50 x 6mm duly powder coated with zink metal coating, front and rear opening type, with apron for cable entry closing locking arrangement including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked,1100 volts grade of appropriate size ( but not less than 2.5 Sqmm)and comprising of the following:-
27(a) Incoming :- (i)MCCB 4 pole , 63Amps,50 Hz,415 Volts, 16 KA, with thermal magnetic release - 01 Nos (ii)3 pole power contractor AC 3rating 40 Amp, 240 Volt AC -01 Nos (iii) Astronomical Digital Timer Switch240 V AC -01 Nos (iv)Digital VAF+PF meter with RS 485 Cl-1 -01No (v) CTsratio 200/5 A ,class 1, ISI marked -01 sets of three (vi) Indicating lamp- 01 set of three (vii)Four Pole, Aluminium bus bar 150 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators.
28(b) Outgoing (i)MCCB 4 pole , 40Amps,50 Hz,415 Volts, 16 KA thermal magnetic release- 02 Nos Note - Plateform of panel fixed with PCC 1:4:8 type D-2 with 40mm graded crused stone ,15 cm thick in foundation,brick work in CM 1:6 with sub class B old size bricks ,rendring 15 mm thick in CM 1:6 on exposed surface and 100 mm thick PCC padding 1:3:6,type C-1 using 20mm graded crushed stone aggregate on Top and grouting bolts etc for panel.The plate form shall be such that it is of a height 45 cm above the nearest road level. All out going feeder shall be connected by cable through suitable size gland plate/glands. All MCCB with adjustable protection for over load and shortcircuit protection and confirming to IEC60947-II/IS 13947 -II (Latest Version). The MCCBs shall have spreader links and barriers as standard feature of manufacture.
29Supply, installing, testing and commissioning in replacement factory made, CPRI approvedLT Panel board (Dimention of Cubical / enclosure not less than 900 mm x 600 mm x 500mm), confirming to IS 5039, cubical compartmentalized, out door type, double door, plate form mounted, suitable for 415 volts, 3 phase, 4 wire, 50 HzAC supply system, having bus bar chamber with insulated aluminium bus bars four pole installed on porcelain / SMC insulator. The panel shall be dust and vermin proofIP-54 class protection and outer shell made of of 3.15 mm CRCA sheet, inner shell made of 2.0 mm thick CRCA sheet, 50 x 50 x 6mm thick MS angle iron frame work, the cubical have bottom channel of size 75 x 40 mm, duly powder coated with zink metal coating, front and rear opening type, with apron for cable entry closing locking arrangement including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked,1100 volts grade of appropriate size ( but not less than 2.5 Sqmm)and comprising of the following:-
30(a) Incoming :- (i)MCCB 4 pole , 200Amps,50 Hz,415 Volts, 36 KA, with thermal magnetic release - 01 Nos (ii) Digital VAF+PF meter with RS 485 CL1 -01No (iii) CTsratio 400/5 A ,class 1, ISI marked -01 sets of three (iv)Indicating lamp- 01 set of three (v) Four Pole , Aluminium bus bar 400 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators. (b) Outgoing (i) MCCB 4 pole , 63Amps,50 Hz,415 Volts, 36 KA thermal magnetic release- 06 Nos
31Note - Plateform of panel fixed with PCC 1:4:8 type D-2 with 40mm graded crused stone ,15 cm thick in foundation,brick work in CM 1:6 with sub class B old size bricks ,rendring 15 mm thick in CM 1:6 on exposed surface and 100 mm thick PCC padding 1:3:6,type C-1 using 20mm graded crushed stone aggregate on Top and grouting bolts etc for panel.The plate form shall be such that it is of a height 45 cm above the nearest road level. All out going feeder shall be connected by cable through suitable size gland plate/glands. All MCCB with adjustable protection for over load and shortcircuit protection and confirming to IEC60947-II/IS 13947 -II (Latest Version). The MCCBs shall have spreader links and barriers as standard feature of manufacture.
32Supply, installing, testing and commissioning in replacement factory made, CPRI approved out door type busbar panel board (Dimention of Cubical / enclosure not less than 600 mm x 450 mm x 450mm) confirming to IS 5039, made out of3.15 mm thick MS sheet and MS angle section 50 x 50 x 6 mm suitable for 3 phase 4 wire 415 Volt, 50 Hz, overall powder coated with zink metal coating comprising the following:- (a)FP, Aluminium bus bar 500 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators. (b) Incoming MCCB 250 Amps 36 KA, 415 Vots, 50 Hz, FP.– 1 No (c)LED Indicator lamp RYB - 01 set of three.
33Note - Plateform of panel fixed with PCC 1:4:8 type D-2 with 40mm graded crused stone ,15 cm thick in foundation,brick work in CM 1:6 with sub class B old size bricks ,rendring 15 mm thick in CM 1:6 on exposed surface and 100 mm thick PCC padding 1:3:6,type C-1 using 20mm graded crushed stone aggregate on Top and grouting bolts etc for panel.The plate form shall be such that it is of a height 45 cm above the nearest road level. All out going feeder shall be connected by cable through suitable size gland plate/glands. All MCCB with adjustable protection for over load and shortcircuit protection and confirming to IEC60947-II/IS 13947 -II (Latest Version). The MCCBs shall have spreader links and barriers as standard feature of manufacture.
34Supply and installed steel tubular swaged pole type 410 SP - 31 (9 mtr long) complete with MS base plate of size 300 x 300 x 6mm thick at bottom, welded at the centre with through hole of 14 mm dia at a height of 300 mm above the coping finial cap and painted with two coats of aluminium paint over a coat of red oxide primer, making of strip of 300 mm width (balck and yellow in alternate band) upto 1500 mm height with one synthetic enamel paint, writing pole No with stencil with white colour in black background with synthetic enamel paint including excavation upto required depth and PCC type C-2 1:3:6 (using 40mm graded) at bottom and PCC type B-1 1:2:4 (20mm graded) for mass filling and pole coping (60x60x30cm) and rendering of coping with 5 mm thick in 1:3 cement mortar complete all as specified and directed.
35Material & Labour for preparation old painted steel surface of LT tubular pole pole 9 / 11 meter long above coping, including MS clamp and applying two coat of aluminium paint, making of strip of 300 mm width (balck and yellow in alternate band) upto 1500 mm height with one synthetic enamel paint, rewriting pole No with stencil with white colour in black background with synthetic enamel paint, complete all as specifeid and directed.
36Supply, fix, connecting andtesting in replacementMCCB 63 Amp 4 pole 25 KA 415 volts 50 Hzthermal magnetic release with spreader after taking down old existing unserviceableMCCB complete all as directed.
37Supply, fix, connecting andtesting in replacementMCCB 100 Amp 4 pole 25 KA 415 volts 50 Hzthermal magnetic release with spreader after taking down old existing unserviceableMCCB complete all as directed.
38Supply, fix, connecting andtesting in replacementMCCB 125 Amp 4 pole 25 KA 415 volts 50 Hzthermal magnetic release with spreader after taking down old existing unserviceableMCCB complete all as directed.
39Supply, fix, connecting andtesting in replacementMCCB 160 Amp 4 pole 25 KA 415 volts 50 Hzthermal magnetic release with spreader after taking down old existing unserviceableMCCB complete all as directed.
40Supply, fix, connecting andtesting in replacementMCCB 200 Amp 4 pole 36 KA 415 volts 50 Hzthermal magnetic release with spreader after taking down old existing unserviceableMCCB complete all as directed.
41Supply, fix, connecting andtesting in replacementMCCB 250 Amp 4 pole 36 KA 415 volts 50 Hzthermal magnetic release with spreader after taking down old existing unserviceableMCCB complete all as directed.
42Supply, fix, connecting andtesting in replacementMCCB 400 Amp 4 pole 36 KA 415 volts 50 Hzthermal magnetic release with spreader after taking down old existing unserviceableMCCB complete all as directed.
43Supply, fix, connecting andtesting in replacementMCCB 630 Amp 4 pole 36 KA 415 volts 50 Hzthermal magnetic release with spreader after taking down old existing unserviceableMCCB complete all as directed.
44Supply and fix in repair Isolator 100 Amps 4 pole fixed in position& connecting complete all as specified and directed
45Supply, fixing, connecting andtesting in replacementMCCB 200 Amp 4 pole 25 KA 415 volts 50 Hz thermal magnetic release with sheet metal enclouser of 1.6 mm thick MS sheet factory made with poweder coat paint including connecting with existing system.after taking down old existing unserviceableMCCB & enclouser complete all as directed.
46S&F Cable jointing kit for 1100 V (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core 25 to 50 Sqmm XLPE armoured aluminium conductor LT UG cable.
47S&F Cable jointing kit for 1100 V (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core 70 to 120 sqmm XLPE armoured aluminium conductor LT UG cable.
48S&F Cable jointing kit for 1100 V (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core 150 to 185 sqmm XLPE armoured aluminium conductor LT UG cable.
49S&F Cable jointing kit for 1100 V (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core 240 to 300 sqmm XLPE armoured aluminium conductor LT UG cable.
50M&L plain cement concrete cast in situ 1:3:6 type C1 using 20 mm graded stone aggregateas in copings for electric pole and other similar work water troughs and the like, weathering, slightly rounded or chamfered angles etc including use & waste form work and demolition of old coping all as specified and directed
51S&F in repair cross arms bracings supports clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paints complte all as specified and directed.
52Supply and fix in replacement of 45 W LED Street light fitting having epoxy powder coated pressure die cast aluminium housing front cover with polycarbonate lens, with elegantly designed heat sink for efficient thermal management, sturdiness & excellent corrosion resistant.IP lens for better distribution . street lightshould haveIP 66 protectionand impact resistance ofIK 07 , Lumen efficiency of LED not less than 100>_ lumen per wattsystem efficency ,power factor >0.95, THD<10% at Full load CRI> 70% ,Street light should have built in potted IP 66 electronic LED driver with APFC, lower THD, open circuit protection , over voltage protection , surge voltage protection 5KV in built & 10KV SPD ,andprovided with company LOGO ingraved on housing of the Streetlightcomplete including taking down of oldUNSV fittings all as specified and directed by Engr -in-Charge. Note :-The contractor should take approval of techincal specification ofluminaries and driver from department before procurement .
53Supply and fix in replacement of 60 W LED Street light fitting having epoxy powder coated pressure die cast aluminium housing front cover with polycarbonate lens with silicon gasket, with elegantly designed heat sink for efficient thermal management, sturdiness & excellent corrosion resistant.IP lens for better distribution and toughened glass fixed to housing withscrews, street lightshould haveIP 66 protectionand impact resistance ofIK 07 , Lumen efficiency of LED not less than 110>_ lumen per wattsystem efficency ,power factor >0.95, THD<10% at Full load CRI> 70% ,Street light should have built in potted DriverTHD, open circuit protection , over voltage protection , surge voltage protection 5KV in built & 10KV SPD ,andprovided with company LOGO ingraved on housing of the Streetlightcomplete including taking down of oldUNSV fittings all as specified and directed by Engr -in-Charge. Note :-The contractor should take approval of techincal specification ofluminaries and driver from department before procurement .
54Supply and fix in replacement of 90 W LED Street light fitting having epoxy powder coated pressure die cast aluminium housing front cover with polycarbonate lens with silicon gasket, with elegantly designed heat sink for efficient thermal management, sturdiness & excellent corrosion resistant.IP lens for better distribution and toughened glass fixed to housing withscrews, street lightshould haveIP 66 protectionand impact resistance ofIK 07 , Lumen efficiency of LED not less than 110>_ lumen per wattsystem efficency ,power factor >0.95, THD<10% at Full load CRI> 70% ,Street light should have built in potted Driver THD, open circuit protection , over voltage protection , surge voltage protection 5KV in built & 10KV SPD ,andprovided with company LOGO ingraved on housing of the Streetlightcomplete including taking down of oldUNSV fittings all as specified and directed by Engr -in-Charge. Note :-The contractor should take approval of techincal specification ofluminaries and driver from department before procurement . .
55Supply and fix in replacement of 120 W LED flood light fitting having epoxy powder coated pressure die cast aluminium housing front cover with polycarbonate lens with silicon gasket, with elegantly designed heat sink for efficient thermal management, sturdiness & excellent corrosion resistant.IP lens for better distribution and toughened glass fixed to housing withscrews , flood lightshould haveIP 66 protectionand impact resistance ofIK 07 , Lumen efficiency of LED not less than 110>_ lumen per wattsystem efficency ,power factor >0.95, THD<10% at Full load CRI> 70% ,Street light should have built in potted IP 66 electronic LED potted driver with open circuit protection , over voltage protection , surge voltage protection 5KV in built & 10KV SPD andprovided with company LOGO ingraved on housing of the flood lightcomplete including taking down of oldUNSV fittings all as specified and directed by Engr -in-Charge. Note :-The contractor should take approval of techincal specification ofluminaries and driver from department before procurement
56Supply and fix in replacementLED 10-12 watt bollard light fitting, having epoxy powder coated pressure die cast aluminium housing Light optic / Diffuser - High impact polycarbonate / Optic colour temprature 5700 K CRi>70,THD<10% PF >.90surge protection 4 KV inbuilt, Rated voltage and frequency 240 Volt,50 Hz street furniture with touch if aesthetic innovative design with uniformly lit diffuser at the upper portion acts a beacon of path guidance in a landsscape IP 65 environmental complete with foundation work nut, bolt and washer etc complete all as specified and directed by Engr in Charge.
57S&F in replacement 40 watt LED Post top energy saving light fitting 240V,50Hz AC, environmental friendly, aesthetically designed electronic constant current,IK07, having epoxy powder coated pressure die cast aluminium housing Top cover spun Al sheet powder coated,front cover Clear acrylic diffuser with indirect symmetrical light distributio, IP-65 luminaire with high powerLED as light source of capacity 40 Watt, 5700K PF >0.9, THD<10% and light efficiency 85>_ ,CRI > 70,Surge protection 5KV incl dismentling taking down unsv fitting any type all as specified and directed.
58Supply and fixingin repair GI Bracket made of40 mm dia GI pipe medium grade 1.5 metre long, bend to shape for street light for steel / RCC pole as per site requirement including MS clamp with nut, bolt, washers complete all as specified and directed by Engineer-in-Charge
59Supply and fix in replacement electronic driver sutaible 45 to 90 watt LED street light / flood light fitting, with constant current, including taking down light fitting from pole and refixing the same place after repairing complete all as specified and directed.
60Supply and fix in replacement electronic driver sutaible 120 to 150 watt LED street light / flood light fitting, with constant current, including taking down light fitting from pole and refixing the same place after repairing complete all as specified and directed.
Disclaimer :