Tender For Maintenance And Repairs Of Ceiling Fan And Exhaust Fan Including Replacement Of Parts And Other Connected Works Of Otm / Md Accommodation Of Bareilly Cantt Under Ge ( West ) Bareilly, bareilly-Uttar Pradesh

Military Engineer Services-MES has published Tender For Maintenance And Repairs Of Ceiling Fan And Exhaust Fan Including Replacement Of Parts And Other Connected Works Of Otm / Md Accommodation Of Bareilly Cantt Under Ge ( West ) Bareilly. Submission Date for this Tender is 13-05-2024. Ceiling Fan Tenders in bareilly Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

43225578
Tender For Maintenance And Repairs Of Ceiling Fan And Exhaust Fan Including Replacement Of Parts And Other Connected Works Of Otm / Md Accommodation Of Bareilly Cantt Under Ge ( West ) Bareilly
Open Tender
Indian
Uttar Pradesh
bareilly
13-05-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Maintenance And Repairs Of Ceiling Fan And Exhaust Fan Including Replacement Of Parts And Other Connected Works Of Otm / Md Accommodation Of Bareilly Cantt Under Ge ( West ) Bareilly

Key Value

Document Fees
INR 500 /-
EMD
INR 66000.0 /-
Tender Value
INR 33 Lakhs /-

Attachment

FileName File Description File Size
e83b0ad4-df22-45ef-9d2d-3d7400f0b56a.html Tender Notice 0 KB
BOQ_728616.xls Tender Document 0 KB
completetender8174.pdf Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

NAME OF WORK: MAINT AND REPAIRS OF CEILING FAN AND EXHAUST FAN INCL REPLACEMENT OF PARTS AND OTHER CONNECTED WKS OF OTM/MD ACCN OF BAREILLY CANTT UNDER GE (WEST) BAREILLY.
Sl. No. Item Description
1Taking down ceiling fans 1200/1400 mm sweep & removing/cleaning of dust properly, oiling and greasing of bearing including re-fixing and connecting up with all requisite accessories complete all as specified and directed.
2Re-winding of ceiling fan burnt motor of 1200/1400 mm sweep including internally and externally cleaning of fans and removing the burnt coil and re-winding of fans by super enameled copper wire of appropriate size and re-assembling the fans and connecting with flexible copper wire of one mtr length and testing after repair complete all as specified and directed.
3Taking down exhaust fan of 450/300 mm sweep and removing/cleaning the dust properly including oiling and greasing complete all as directed.
4Re-winding of exhaust fan burnt motor of 450/300 mm sweep with appropriate size of super enameled copper wire, including re-assembling the fans and connecting with flexible copper wire of one mtr length complete all as directed.
5Supply and Fixingin repairs bush of ceiling fans of any size complete all as directed.
6Supply and Fixingin repairsinsulating rubber real including Supply and replacing nuts, bolts with washers complete all as specified and directed
7Supply and Fixingin repairsshaft of fans (as per sample) of suitable size complete all as specified and directed
8Supply and Fixingin repairs fan pins of suitable size for various type of fans / ceiling fans complete all as specified and directed.
9Supply and Fixingin repairs flexible wire 23/0.0076 PVC insulated copper conductor twin core complete all as specified and directed.
10Supply and Fixingin repairsfan conopy, suitable for various type ceiling fan all as per sample and directed.
11Supply and fixing PVC exhaust fan 250/300 mm with louvers with complete fixing and connection all as directed and specified by Engr-in-Charge.
12Supply and fixing PVC Wall mounting fan of 400 mm size with ocsilating mechanism, motor and allall fittingsand connection all as directed and specified by Engr-in-Charge.
13Supply and fixing PVC Wall mounting fan of 400 mm size with ocsilating mechanism, motor and allall fittingsand connection all as directed and specified by Engr-in-Charge.
14Suply and fixing louvers in repairs of steel for exhaust fan of size 250/300/450 mm all as directed and specified by Engr-in-Charge.
15Cutting of wall for fixing exhaust fan ofPVC/Iron fan of size 250/300/450 mm including fixing requirment at site by grouting fully threaded bolt and nuts including connection complete with one meter copper wire and repair complete, painting of wall all as directed & specified by Engr-in-Charge.
16Taking down carefully existing Aluminum/Copper point wiring (light/ Fan / Socket/Power Point) complete fittings etc. making good to disturbed surface of wall/Floor etc to match the existing surface/ finishes all as directed.
17M&L for concealed pointwiring for one light/ fan/ bell point controlled by one switch with1.5 Sqmm (Nominal area) PVC insulated, unsheathed, stranded copper, conductor cable FRLS (1100Volts grade) drawn in and including PVCconduits of 20 mm dia withall fittings and accessories alongwith PVC insulated cable withcopper conductor of size 1.5 Sqmm as earth continuity conductor including fixing of 1. 2mm thick MS sunk terminal boxdulyflushed to wall with 3mm thick plastic laminated/ebonite sheet cover fixed with screws,cap and washers incl. making good the disturbed surfaces complete all as directed & specified by Engr-in-Charge.
18All as per item no.17 here in before but for socket outlet 3/5 pin 5 amp. on the same board.
19All as per item No 17 here-in-before but for switch socket combination 5 Amps 3/5 Pinpoint on independent board .
20All as per per item No 17 here-in-before but for one light point controlled by two Nos of2 way switchescomplete all as specified anddirected.
21M&L for concealedpoint wiring with 2.5 Sqmm (Nominal area)PVCinsulated,unsheathed, multi stranded Copper conductor cable drawn in and including PVC rigid PVC conduit 25mm or higher sizewith all its fittngs and accessories for one 3 pin/6 pin 15 Amps socket out let point independent alongwith PVC insulated cable with solid copper conductor 1.5 Sqmm (nominal area) continuous earth wire, and connected to earth dolly including fixing of 1.20mm sunk pressed steel terminal box suitably flushedto wall with 3mm thick Hylum sheet cover fixed with screws & cup washers incl. making good complete all as specified anddirected.
22S&FSwitch piano, flush type single pole, one way 5 Amp complete all as specified anddirected.
23S&FSwitch piano, flush type single pole, one way 15 Amp complete all as specified anddirected.
24S&F Socket outlet 2 in 1, 3 pin, 5A flushtype complete all as specified anddirected.
25S&F Socket outlet 2 in 1, 6 pin, 15/5A flushtype complete all as specified anddirected.
26S&FSwitch piano, flush type single pole, two way 5 Amp complete all as specified anddirected.
27Supply and Fixingin repairs Modular switches 1 way, 6 A, 1 module complete all as specified anddirected.
28Supply and Fixingin repairsModular switches 1 way, 16 A, 1 module complete all as specified anddirected.
29Supply and Fixingin repairssocket outlet ,3/5 pin 5ampflush type complete all as specified anddirected.
30Supply and Fixingin repairs socket outlet 2 in one, 3/5 pin5 and 15 Amp flush type complete all as specified anddirected.
31Supply and Fixingin repairsModular sockets6 A, 2/3 pin combined2 module complete all as specified anddirected.
32Supply and Fixingin repairs Modular sockets6 A/16 A, 2/3 pin combined2 module complete all as specified anddirected.
33Supply and Fixingin repairs buzzer, capton ding dong,AC,230V,Single Pole complete all as specified anddirected.
34Supply and Fixingin repairs Modular fan regulatorsstep type, 120 W, 2 module complete all as specified anddirected.
35Supply and Fixingin repairsfan regulator resistance/electronic step type single phase 230 volt. complete all as specified anddirected.
36Supply and Fixingin repairs Condenser 2.5 Mfd make- Havells ,Usha ,Bajaj, Universal complete all as specified anddirected.
37Supply and Fixingin repairs Condenser 3.5 Mfd make- Havells ,Usha ,Bajaj, Universal complete all as specified anddirected.
38Supply and Fixingin repairsMCB SPN20 to 32 Amps240 volts.10kA complete all as specified anddirected.
39Supply and Fixingin repairsMCB SP 6 to 32 Amps240 volts, 10 kA. complete all as specified anddirected.
40Supply and Fixingin repairs MCB TPN 63 Amps,415V,10kA complete all as specified anddirected.
41Supply and Fixingin repairsMCCB TPN 100 Amps, 415V, 16kA ,Thermal Magnetic Release complete all as specified anddirected.
42Taking down unserviceable existing sub main wiring of aluminium conductorstranded cable upto and including of any size single core including earth wire from existing conduit or wooden battens including taking out unserviceable wooden gutties etc, matching with the existing surfaces complete all as specified and as directed.
43M & L Sub main wiring concealed type with two single core cable PVC insulated cable with 4.0Sqmm (Nominal area) multi stranded copper conductor cable 1100 volts gde incl earth continuity conductor using PVC insulatedcable of copper conductor of size 4.0 Sqmm connected to common earth dolly anddrawing into rigid PVC conduit of 25mm dia medium grade size incl. making good the disturbed surface complete complete all as specified anddirected. (Note : PVC conduit and its accessories including 2 runs of cable & 1 run of earth continuity conductor cable unsheathed shall be measured and paid as single unit).
44M & L Sub main wiringconcealed type with two single core cable PVC insulated cable with6.0Sqmm (Nominal area) multi stranded copper conductor FRLS cable 1100 volts gde incl earth continuity conductor using PVC insulatedcable of stranded copper conductor of size6.0Sqmm connected to common earth dolly anddrawing into rigidPVC conduitsof 25 mm dia medium gradesize incl. making good the disturbed surfacescomplete all as specified anddirected. (Note : PVC conduit and its accessories including 2 runs of cable & 1 run of earth continuity conductor cable unsheathed shall be measured and paid as single unit)
45S&F in replacement sheet metal enclosure DB"s 415 Volts, IP-42, vertical suitable for mounting MCCB"s, TPN,4 way with 200 Amps rated copper bus bar complete all as directed by Engineer-in-charge.
46Supply and Fixingin repairs double door MCB distribution boards sheet steel, powder coated DBs suitable for MCBs fitted with bus bar, neutral link earth bar and din rail single phase and neutral confirms to IS : 13032-1991 of 4 wayscomplete all as specified and directed.
47Supply and Fixingin repairs double door MCB distribution boards sheet steel, powder coated DBs suitable for MCBs fitted with bus bar, neutral link earth bar and din rail single phase and neutral confirms to IS : 13032-1991 of 8 wayscomplete all as specified and directed.
48Supply and Fixingin repairs double door MCB distribution boards sheet steel, powder coated DBs suitable for MCBs fitted with bus bar, neutral link earth bar and din rail single phase and neutral confirms to IS : 13032-1991 of 12 ways complete all as specified and directed.
49S&F LEDtube light with ALUMINIUMextruded battern 20watt 4 feetWhite colour including dismentiling and taking down any type of FTL/LEDcomplete all as specified and directed.
50S&F in repairs building scurity light led type 20 watt including GI pipe bracket 32 mm dia with clamp including complete connection wih copper wire all as directed and specified by Engr-in-Charge.
51S&F LED mirror light fixture 10 Watt LEDin aluminium extructed 6000K 50Hz 240V all as directed and specified by Engr-in-Charge..
52S&F machine screw for fitting hylem sheet complete all as specified anddirected.
53S&F 2"x 2" LED recess/ surface mounted fitting 36 Watt, 230V, withintegrated electronic driver high transcluent frosted diffuser, connector block, etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed.
54S&F 1"x 1" LED recess/ surface mounted fittingupto18 Watt, 230V, withintegrated electronic driver high transcluent frosted diffuser, connector block, etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed.
55S&F recess/surface mounted LED downlighter of round/square upto 12 Watt concealed /surfacemounted with removable driver complete all as specifid and directed.
56S&F in replacement of PVC non metallic casing caping of 25mm size with accessories such as saddle etc. complete all as specified anddirected.
57Supply and fixing 1.5 sqmm copper wire in replacement of old wire complete all as specified anddirected.
58Supply and fixing 2.5 sqmm copper wire in replacement of old wire complete all as specified anddirected.
59Supply and fixing 4.0 sqmm copper wire in replacement of old wire complete all as specified anddirected.
60Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVCinsulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 10 sq. mm nominal cross section in service connections complete all as specified anddirected.
61Supply and fixing in repairs LED post top lantern with die cast aluminium spigot, spun aluminium powder coated top cover, Alumnium PDC heat sink, opal PC diffuser and clear acrylic of complete all as specified anddirected.
62S&F repairs paino switch flush type 5 Amps single pole one way complete all as specified and directed.
63S&F repairs paino switch flush type 15 Amps single pole one way complete all as specified and directed.
64S&Fceiling fan 1200 mm sweep 230 V 50 Hz complete with motor, blade, canopy and down rod complete all as specified and directed.
65Supply and fixing exhaust fan 250/300 mmin metal body with louvers inclfixing and connection all as directed and specified by Engr-in-Charge.
66Notes :- (i) For Serial No 01 to 14: The contractor has to complete the work assigned for said items with in 10 days from issue of fan through gate pass failing in which recovery at the rate of Rs. 25per day per complaint shall be deduct. (ii) For Serial No 15 to 68 : The Contractor has to complete the work assigned for above items with in 72 hours failing in which recovery at the rate 25 Rs. Per day per complaint(iii) The contractor has to maintain a separate complaint slip book and complaint register for attending complaint. The contractor rep have to collect daily complaint slip from the E/M complaint cellon the same day at 09 AM and get them signed from user after completing the job and submit to E/M complaint cell. (ii) Tenderers may note that amount as given in schedule of credit will be deducted from the total amount to worked out the net contract sum at the time of Acceptance of tender.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail