Public Works Department-PWD has published Tender For Restoration Of Road Cut Reru To Dhogri. Submission Date for this Tender is 14-05-2024. Road Repair Tenders in jalandhar Punjab. Bidders can get complete Tender details and download the document.
FileName | File Description | File Size |
51c4b7d5-4ce1-4864-b4e0-f7ec51828620.html | Tender Notice | 0 KB |
BOQ_247918.xls | Tender Document | 0 KB |
Copa_Condition.pdf | Tender Document | 0 KB |
SBD.pdf | Tender Document | 0 KB |
Technical_Conditions.pdf | Tender Document | 0 KB |
Tendernotice_1.pdf | Tender Document | 0 KB |
Sl. No. | Item Description |
1 | PART-IREPAIR WORK Excavation in Soil (any type) using Hydraulic Excavator CK 90 Excavation with hydraulic excavator of 0.9 cum bucket capacity including cutting trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, including all lift and combined lead up to 60 mtr.. |
2 | Compaction of earth work & Preparation of sub grade including loosening, leveling of earth 225mm thick top layer, rough dressing of soil, final dressing of earth to give level, camber, watering, rolling with road roller, compacting the bed to achieve minimum dry density as given in the Table 300-2 as per Technical clause 305 of MORT&H specifications. (In case of link roads earth work to be done by villagers) |
3 | Providing & Laying of Fine sand Filling including , loading, unloading, carriage and laying at site, watering & rolling with road roller compacting the bed as per Satisfaction of Engineer in Charge |
4 | Construction of granular sub-base by providing material as per grading-III ( Table 400-I of MORT&H 5th revision), mixing in a mechanical mix plant at OMC, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per technical clause 401 of MORT&H specifications |
5 | Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density complete as per technical clause 406 of MORT&H specifications |
6 | Providing and applying primer coat with bitumen emulsion SS on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.85kg/sqm complete as per technical clause 502 of MORT&H specifications |
7 | Providing and applying tack coat with bitumen emulsion RS using emulsion pressure distributor at the rate of 0.25 kg per sqm on the prepared bituminous surface/ granular surface treated with prime coat after cleaning the surface complete as per technical clause503 of MORT&H specifications |
8 | Providing and laying Densegraded Bituminous Macadam 50mm to 75mm thick (Grading II) with Continuous type hot mix plant using crushed aggregates of specified grading, premixed with bituminous binder VG-30 @ 4.5%, laying with a Paver Finisher Mechanical to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction complete as per technical clause 505 of MORT&H specifications NOTES : - (i) Job mix formula for thedense bituminous macadam shall be provided by the agency and shall be got approved from Punjab PWD, B&R Research Laboratory Patialabefore adoption at site for execution.. (ii) The specification of this item for analytic purpose is kept with bitumen content @ 4.50% weight of mix variation as compared with job mix formula shall be paid / deducted accordingly. The limits of variation shall be worked out with the approved formula.TECHNICAL NOTE : - (i) Apart from the confirmity with the grading and quantity requirement of invidual ingredients exhibited above the mix aggregate i.e.coarse and fine aggregate for dense bituminous concrete shall meet all requirements set forth clause 505 of MORT & H specifications. (ii) The final grading for the aggregates required fordense bituminous macadam confirming to table 500.10 of MORT & H specifications shall be determined after getting the dense bituminous macadam designed from Punjab PWD, B&R Research Laboratory Patiala after obtaining 60 %of material. The design mix so finally approved shall be termed as the approved mix. Theaggregates shall be hydrophobic and of low porosity. Theaggregates shall satisfy the physical requirement set fourthin table 500-6 (addendum to latest revision). (iii) The approved mix shall exhibit the following details, source and location of all material: - (a) Binder expressed as percentage by weight of total mix. (b) Course expressed as percentage by weight of total mix. (c) Crushed bajri expressed as percentage by weight of total mix. (d) Fine aggregate expressed as percentage by weight of total mix (e) A single definite percentage passing each sieve for mixed aggregates. (f) Density of dense bituminous macadam after compaction will be not less than 2.30 gm/CC. |
9 | Providing and laying Bituminous Concrete 30mm to 45mm thick ( Grading-II ) with Continuous type hot mix plant using crushed aggregates of specified grading, premixed with bituminous binder VG-30 @ 5.4%, laying with a Paver Finisher Mechanical to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction complete as per technical clause 507 of MORT&H specifications NOTES : - (i) Job mix formula for the bituminous concrete shall be provided by the agency and shall be got approved from Punjab PWD, B&R Research Laboratory Patiala before adoption at site for execution. (ii) The specification of this item for analytic purpose is kept with bitumen content @ 5.4% weight of mix variation as compared with job mix formula shall be paid / deducted accordingly. The limits of variation shall be worked out with the approved formula.TECHNICAL NOTE : - i.) Apart from the confirmity with the grading and quantity requirement of invidual ingredients exhibited above the mix aggregate i.e.coarse and fine aggregate for bituminous concrete shall meet all requirements set forth clause 507 of MORT & H specifications. ii) The final grading for the aggregates required for bituminous concrete confirming to table 500.17 of MORT & H specifications shall be determined after getting the bituminous concrete designed from Punjab PWD, B&R Research Laboratory Patiala after obtaining 60 % of material. The design mix so finally approved shall be termed as the approved mix. The aggregates shall be hydrophobic and of low porosity. The aggregates shall satisfy the physical requirement set fourth in table 500-6 (addendum to latest revision). iii) The approved mix shall exhibit the following details, source and location of all material: - (a) Binder expressed as percentage by weight of total mix. (b) Course expressed as percentage by weight of total mix. (c) Crushed bajri expressed as percentage by weight of total mix. (d) Fine aggregate expressed as percentage by weight of total mix (e) A single definite percentage passing each sieve for mixed aggregates. (f) Density of bituminous concrete after compaction will be not less than 2.35 gm/CC. |
10 | Construction of embankment with earth obtained from roadway cutting or excavation including spreading, grading to required slope and compacting to meet requirement of table 300-2 as per technical clause 305 of MORT&H specifications |
11 | Providing and making Rumble Strips 15-20mm high at centre, 250mm wide placed at 1m centre to centre over freshly laid bituminous layer by using close graded premix surfacing material type B at approved locations to control speed and marked with 100mm wide white strips of thermoplastic road marking paint. The close graded premix surfacing material type B shall conform to technical clause 512 and thermoplastic road marking paint shall conform to technical clause 803 of MORT&H specifications |
12 | Road marking with hot applied thermoplastic compound 2.5mm thick including reflectorising glass beads @ 0.25kg per sqm area as per IRC:35 1997 complete as per technical clause 803 of MORT&H specifications |
13 | Reinforced cement concrete M-15 grade ordinary kilometre stone for Plan Roads of standard design as per IRC 8-1980 fixing in position including painting and printing etc. complete as per technical clause 804 of MORT&H specifications |
14 | Providing & Fixing Reinforced cement concrete M-15 grade 200 metre stone of standard design as per IRC 26-1967 fixing in position including painting and printing etc. complete as per technical clause 804 of MORT&H specifications |
15 | Reinforced cement concrete M-15 grade Boundary Pillars of standard design as per IRC 25-1967 fixing in position including painting and printing etc. complete as per technical clause 806 of MORT&H specifications |
16 | Reinforced cement concrete M-15 grade Village Board of standard design fixing in position including painting and printing etc. complete as per PWD specifications |
17 | Place Identification sign board 900x600mm rectangular as per IRC 67- 2012 with high intensity Microprismatic grade retro reflective Sheeting Type IV as per ASTM D 4956 – 09 and as per IRC 67 – 2012 fixed over 4mm thick aluminium Composite material (ACM) sheeting having aluminium skin thickness of 0.4 to 0.5 mm on both sided and fixing the same with suitable size aluminium alloy rivets @ 200 mm c/c to back support frame of 25x25x3mm angle iron supported on two square hollow steel section post 60x60x3.2mm conforming to IS 4923 firmly fixed to ground in foundation concrete M-25 of size 0.45x0.45x0.60m for vertical post complete as per clause 801 of MORT&H specifications. Supplier shall provide a warranty as per clause 6.9 of IRC 67-2012 for retro reflective sheeting & a certified copy of test reports from an independent test laboratory conforming to clause 6.7 of IRC 67-2012 |
18 | Cautionary sign board 600x600x600mm triangular as per IRC 67- 2012 with high intensity Microprismatic grade retro reflective Sheeting Type IV as per ASTM D 4956 – 09 and as per IRC 67 – 2012. fixed over 3mm thick aluminium Composite material (ACM) sheeting having aluminium skin thickness of 0.25 to 0.3 mm on both sided and fixing the same with suitable size aluminium alloy rivets @ 200 mm c/c to back support frame of 25x25x3mm angle iron supported on a square hollow steel section post 60x60x3.2mmmm conforming to IS 4923 without cost of definition plate firmly fixed to ground in foundation concrete M-25 of size 0.45x0.45x0.60m for vertical post complete as per clause 801 of MORT&H specifications. Supplier shall provide a warranty as per clause 6.9 of IRC 67-2012 for retro reflective sheeting & a certified copy of test reports from an independent test laboratory conforming to clause 6.7 of IRC 67-2012 |
19 | Mandatory sign board 600mm circular as per IRC 67- 2012 with high intensity Microprismatic grade retro reflective Sheeting Type IV as per ASTM D 4956 – 09 and as per IRC 67 – 2012. Fixed over 3mm thick aluminium Composite material (ACM) sheeting having aluminium skin thickness of 0.25 to 0.3 mm on both sided and fixing the same with suitable size aluminium alloy rivets @ 200 mm c/c to back support frame of 25x25x3mm angle iron supported on a square hollow steel section post 60x60x3.2mm conforming to IS 4923 without cost of definition plate firmly fixed to ground in foundation concrete M-25 of size 0.45x0.45x0.60m for vertical post complete as per clause 801 of MORT&H specifications. Supplier shall provide a warranty as per clause 6.9 of IRC 67-2012 for retro reflective sheeting & a certified copy of test reports from an independent test laboratory conforming to clause 6.7 of IRC 67 2012 . |
20 | Definition Plate 600x200mm rectangular as per as per IRC 67- 2012 with high intensity Microprismatic grade retro reflective Sheeting Type IVas per ASTM D 4956 – 09 and as per IRC 67 – 2012. specifications. Fixed over 3mm thick Aluminium Composite Material (ACM) sheeting having aluminium skin thickness of 0.25 to 0.3 mm on both sided and fixing the same with suitable size aluminium alloy rivets @ 200 mm c/c to back support frame welded with vertical post of sign board complete as per clause 801 of MORT&H specifications. Supplier shall provide a warranty as per clause 6.9 of IRC 67-2012 for retro reflective sheeting & a certified copy of test reports from an independent test laboratory conforming to clause 6.7 of IRC 67-2012 . |
21 | Vediography of road |
22 | Credit for Soil Excavated Including all taxces and Royalty |
23 | Add extra cost of Cutlural Cess @ 1% on Total costas items mentioned above |
24 | Routine Maintenance Work (Part-II) Routine Maintenance work for 2nd year to 5th year |
25 | Routine Maintenance work 2nd Year after completion |
26 | Routine Maintenance work 3rd Year after completion |
27 | Routine Maintenance work 4th Year after completion |
28 | Routine Maintenance work 5th Year after completion |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail