Tender For Provision Of Improvement And Enhancement Of Old Existing Temporary Shelters And Ancillaries Including Infrastructural Developments Work For Cob Pedi Of 25 Ar Bn, Peren-Nagaland

Assam Rifles-AR has published Tender For Provision Of Improvement And Enhancement Of Old Existing Temporary Shelters And Ancillaries Including Infrastructural Developments Work For Cob Pedi Of 25 Ar Bn. Submission Date for this Tender is 07-05-2024. Civil Work Tenders in Peren Nagaland. Bidders can get complete Tender details and download the document.




Tender Notice

43221379
Tender For Provision Of Improvement And Enhancement Of Old Existing Temporary Shelters And Ancillaries Including Infrastructural Developments Work For Cob Pedi Of 25 Ar Bn
Open Tender
Indian
Nagaland
Peren
07-05-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Tender For Provision Of Improvement And Enhancement Of Old Existing Temporary Shelters And Ancillaries Including Infrastructural Developments Work For Cob Pedi Of 25 Ar Bn

Key Value

Document Fees
INR 1500 /-
EMD
INR 542500.0 /-
Tender Value
INR 2.71 Crore /-

Attachment

FileName File Description File Size
8515b9dd-defb-4c49-86d8-7f819bdb0267.html Tender Notice 0 KB
BOQ_845763.xls Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

Name of Work : Provn of improvement & enhancement of old existing temporary shelters and ancillaries including infrastructural development work for Pedi of 36 AR (Now 25 AR) (Nagaland)
Sl. No. Item Description
1SCHEDULE ‘A’ PART - I
2Supply & Construction of Prefabricated fast eractable modular shelter for SM Bk (18.30 m x 6.10 m x 3.00 m) including Internal and external Electfication & Furniture all as per Drg No. DGAR/COB/01, Sheet No. 1/10 to 10/10).
3SCHEDULE ‘A’ PART - II
4Supply & Construction of Prefabricated fast eractable modular shelter for Security Tower/ Sentry Post/Guard Room (8.4 Mtr (7.9+0.5) height) including Internal and external Electfication & Furniture all as per Drg No. DGAR/COB/07, Sheet No. 1/11 to 11/11).
5SCHEDULE ‘A’ PART - III
6Supply & Construction of PFTS six seated toilet block (PFTS 7.20 m x 2.20 m) for 06 men incl Water supply, Internal & external Electrification and Septic Tank and Soak Pit all as per Drg No. DGAR/COB/06, Sheet No. 1/1 and 1 toDrg No. DGAR/Engr/COB/114, DGAR/COB/06, DGAR/COB/05, Sheet No. 1/3 to 03/03, 1/1, 1/2 to 2/2).
7SCHEDULE ‘A’ PART - IV (Construction of Security fencing)
8Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m in all Kind of soil.
9Providing and laying in position cement concrete of 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) excluding the cost of centering and shuttering - All work up to plinth level.
10Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts.
11Supplying at site Angle iron post & strut of required size including bottom to be split and bent at right angle in opposite direction for 10cm length and drilling holes upto 10 mm dia. etc. complete.
12Supplying and fixing Welded steel wire fabric of required width having rectangular mesh painted with two or more coats of enamel paint of approved shade over a coat of primer (Priming & Painting to be paid for separately).
13Extra for providing and fixing 40x 6 mm flat iron section for barbed wire
14Painting with Two or more coats on new work aluminium paint of approved brand and manufacture to give an even shade.
15Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron "Y" shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre.
16Fencing with angle iron post placed at required distance embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with horizontal lines and two diagonals interwoven with horizontal wires, of barbed wire weighing 9.38 kg per 100 m (minimum), between the two posts fitted and fixed with G.I. staples, turn buckles etc. complete with G.I. barbed wire. (Cost of posts, struts, earth work and concrete work to be paid for separately). Payment to be made per metre cost of total length of barbed wire used.
17SCHEDULE ‘A’ PART - V(Construction of Black Top bitumen Internal Road)
18Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge in all kind of soil.
19Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 m.
20Supply, stacking and Laying, spreading and compacting 90 mm to 45 mm size stone aggregate to WBM with morum as binding materials including 13.2mm sizestone screening in uniform thickness, hand picking, rolling with 3 wheeled road / vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the reqd density.etc complete as per direction of Engineer - in - Charge.
21Supply, stacking and Laying, spreading and compacting 63 mm to 45 mm size stone aggregate to WBM with morum as binding materials including 11.2mm sizestone screening in uniform thickness, hand picking, rolling with 3 wheeled road / vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the reqd density.etc complete as per direction of Engineer - in - Charge.
22Providing and applying tack coat using hot straight run bitumen of grade VG - 10 On W.B.M. @ 0.75 Kg / sqm, including heating the bitumen, spraying the bitumen with mechanically operated spray unit fitted on bitumen boiler, cleaning and preparing the existing road surface as per specifications.
232.5 cm premix carpet surfacing with 2.25 cum and 1.12 cum of stone chippings of 13.2 mm and 11.2 mm size respectively per 100 sqm and 52 kg and 56 kg of hot bitumen per cum of stone chippings of 13.2 mm and 11.2 mm size respectively, including a tack coat with hot straight run bitumen, including consolidation with road roller of 6 to 9 tonne capacity etc. complete (tack coat to be paid for separately). with paving Asphalt grade VG - 10 heated and then mixed with solvent at the rate of 70 grams per kg of asphalt etc complete and all as per direction of Engineer - in - Charge.
24Providing and laying seal coat of premixed fine aggregate ( passing 2.36 mm and retained on 180 micron sieve) with bitumen using 128 kg of bitumen of grade VG - 10 bitumen per cum of fine aggregate and 0.60 cum of fine aggregate per 100 sqm of road surface, including rolling and finishing with road roller all complete
25SCHEDULE ‘A’ PART - VI (Construction of Retaining Wall)
26Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m in all kinds of soil.
27Providing and laying in position cement concrete of 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) excluding the cost of centering and shuttering - All work up to plinth level.
28Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with Cement mortar 1:6 (1 cement : 6 coarse sand).
29Random rubble masonry with hard stone in superstructure above plinth level and upto floor five level, including leveling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) at window sills, ceiling level and the like with Cement mortar 1:6 (1 cement : 6 coarse sand).
30Providing and laying 50 mm thick cement concrete 1:2:4 (1 cement: 2 coarse sand :4 graded stone 20 mm nominal size agg) excluding the cost of centering and shuttering.
31Raised and cut Pointing on stone work with cement mortar 1:3 (1 cement : 3 sand) with raised and cut pointing.
32Supply and stacking at site 20mm size stone aggregates
33Providing and fixing on wall unplasticised rigid PVC pipes 75 mm diain weep holes.
34Providing and laying in position cement concrete of 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) excluding the cost of centering and shuttering - All work up to plinth level.
35Providing and laying in position cement concrete of 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources) excluding the cost of centering and shuttering - All work up to plinth level.
36SCHEDULE ‘A’ PART - VII (Constructionof Storm Drainage)
37Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge in All kinds of soil.
38Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m in All kinds of soil.
39Providing and laying in position cement concrete of 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources) excluding the cost of centering and shuttering - All work up to plinth level.
40Providing and laying in position cement concrete of 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) excluding the cost of centering and shuttering - All work up to plinth level.( For Drain Bed and wall)
41Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with Cement mortar 1:6 (1 cement : 6 coarse sand).
4212 mm cement plaster of mix 1:4 (1 cement: 4 fine sand).
43SCHEDULE ‘A’ PART - VIII (Construction of PCC Footpath with Chequered Tiles)
44Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge in All kinds of soil.
45Supply, stacking and Laying, spreading and compacting 90 mm to 45 mm size stone aggregate to WBM with morum as binding materials including 13.2mm sizestone screening in uniform thickness, hand picking, rolling with 3 wheeled road / vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the reqd density.etc complete as per direction of Engineer - in - Charge.
46Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering, all work up to plinth 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size).
47Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand) with Ordinary cement without any pigment
48Centering and shuttering including strutting, propping etc. and removal of form for Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
49Finishing walls with Premium Acrylic Smooth exterior paint on new work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)with Silicone additives of required shade.
50SCHEDULE ‘A’ PART - IX (Provn of earthwork in excavation in over areas)
51Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge in All kinds of soil.
52SCHEDULE ‘A’ PART - X (Addn/Altn of existing Cook House cum Dining HallBldg No. AR/66)
53Repair to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sqm and under incl cutting the patch in proper shape, racking out joints and plastering the surface of the walls, including disposal of rubbish to the dumping ground within 50m lead etc. complete with CM 1:4( 1 cement : 4 coarse sand).
54Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead for thickness of tiles 10 mm to 25 mm.
55Providing and laying vitrified floor tiles in sizes 600mm x 600mm(thickness to be specified by the manufacturer) with water absorption less than 0.08%, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.
56Providing and laying Vitrified tiles in sizes 600 x 600mm (thickness to be specified by manufacturer), of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete
57Providing and laying Polished Granite stone flooring in required design of Black,Cherry/Ruby Red or equivalent colour and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge
58Finishing walls with Acrylic Smooth exterior paint with silicone additive of required shade on new work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm).
59Providing and finishing with two or more coats applied @ 1.43 ltr/10 Sqm over existing cement paint surface Premium Acrylic smooth exterior paint with silicon additives of required shadeincluding removing of old water proofing cement paint by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc complete.
60Providing and applying white cement based putty of average thickness 1mm, of approved brand and manufacturer , over the plastered wall surface to prepare the surface even and smooth complete.
61Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on new work (two or more coats) over and including water thinnable priming coat with cement primer.
62Distempering with oil bound washable distemper approved brand and manufacturer to given an even shad in old work (one or more coats) incl preparation of old surface by removing old paint by scrapping, sand papering incl necessary repairs to scratches etc complete.
63Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade,One or more coats on old work.
64Half brick work with common burnt clay F.P.S (non modular) bricks of class designation 7.5 in superstructure in plinth level in Cement mortar 1:4 (1 cement : 4 coarse sand).
65Providing and laying 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix 1:4 (1 cement : 4 fine sand)
66Providing and laying in position cement concrete of 1:3:6 with 20 mm graded stone aggregates including centering and shuttering etccomplete in drain.
67Providing and making plinth protection 50 mm thick of cement concrete (1:3:6) with stone aggr 20 mm nominal size) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth.
68Dismantling cement asbestos sheets or other hard board in ceiling,including stacking of serviceable materials and disposal of unserviceable materials within 50 metres lead.
69Dismantling wood work in frames, trusses, purlins and rafters up to 10 metres span and 5 metres height including stacking the material within 50 metres lead.
70Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angleof size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting /making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge of GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8mm drop; made of G I sheet having galvanizing of 100gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns(minimum), including factory painted after bending.
71Dismantling roofing of GS Sheet roofing,including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres.
72Providing and fixing of PPGI profile Sheet of 0.50mm (+0.05%) total coated thickness with zinc coating 120 gm per sqm in 240 mpa steel grade, 5-7 microns epoxy primer on both sides of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scrateches during transportation and should be supplied single length upto 12m or as desired by Engineer - In - Charge . The sheets should be fixed using self drilling/ self tapping screws of size 5.5x55mm with EPDM seal, complete to the existing truss and purlins etc complete.
73Providing and fixing PPGI sheet ridges or hips of width (500- 600mm) overall width plainsheet of 0.50 mm (+0.05%) total thickness , zinc coating fixed 120grms per sqm as per IS :277 using self drilling or self tapping screws complete.
74Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead of area 3 sq. metres and below.
75Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with inbuilt roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rodof required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.Three track three panels sliding window made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension.
76Providing and fixing fly proof wire gauge to windows, doors and ventilators with MS flat 15x3mm and nuts & bolts completeof Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides.
77Renewing glass panes, with putty and nails wherever necessary including racking out the old putty with float glass panes of thickness 4 mm.
78Providing and fixing 35mm thick factory made laminated flush door shutters decorative type, core of block boards construction with frame of 1st class hard wood including stainless steel butt hinges with screws etc complete.
79Providing and fixing of mosquito proof shutters using galvanized MS wire gauge of average width of aperature 1.4mm in both directions with wire of dia 0.63mm for door of 35mm with 2nd class teak wood.
80Providing and fixing aluminium handles of size : 100 mm, transparent or dyed to required colour or shade, with necessary screws etc. complete
81Providing and fixing aluminium tower bolts of size : 100x10 mm with necessary screws etc. Complete.
82Supply and fixing aluminum sliding door bolts, transparent or dyed to required colour or shade, with nuts and screws etc complete of size 250x16mm.
83Providing and fixing nickel plated M.S. pipe curtain rods with nickel plated bracketsof 25 mm dia (heavy type).
84Providing and fixing 20 mm nominal dia CPVC pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints completeas per direction of Engineer in Charge
85Providing and fixing 15 mm nominal dia CPVC pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints completeas per direction of Engineer in Charge
86Providing and fixing 25 mm nominal dia CPVC pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge
87Providing and fixing of 15mm nominal bore CP bib cock of approved quality.
88Providing and fixing of 20 mm dia brass stop cock of approved quality etc. Complete.
89Providing and fixing 15mm nominal bore C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.
90Providing and fixing of PTMT towel rail ring trapezoidal shape 215mm long, 200mm wide with minium distances of 37mm from wall face with concesled fittings arrangement of approved qaulity of 600mm long.
91Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, incl painting of fittings and brackets, cutting and making good the walls wherever requireWhite Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps.
92Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing of Rectangular shape 1500x450 mm.
93Providing and fixing on wall unplasticised rigid PVC pipes incl jointing with seal ring, single socketed pipes of 75 mm dia.
94Construction of brick masonry manhole in cement mortar (1:4) with RCC top slap with (1:2:4) mix foundation concrete (1:4:8) mix inside plastering 12 mm thick with CM (1:3) finished with floating coat of neat cement and making channel in cement concrete (1:2:4) etc complete with common burnt clay FPS (non modular) bricks.
95Providing and fixing of 15mm nominal bore CP angle cock of approved quality.
96Providing and fixing 25mm nominal bore gun metal gate valve with CI wheel of approved quality ( screwed end)
97Providing and fixing 3 layer PN - 16 Pipe, 40 mm OD (SDR-7.4) PP-R pipes confirming to IS:15801 UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, including trenching, refilling & testing of joints complete as per direction of Engineer-in-Charge.
98Providing and fixing 3 layer PN - 10 Pipe, 50 mm OD (SDR-7.4) PP-R pipes confirming to IS:15801 UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, including trenching, refilling & testing of joints complete as per direction of Engineer-in-Charge.
99Providing and fixing 40mm nominal bore gun metal gate valve with CI wheel of approved quality ( screwed end)
100Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable and 1.5 sq.mm. FR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required (Group B) .
101Supply and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
102Supplying and fixing 5/6 amps Piano switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
103Supplying and fixing 15/16 amps Piano switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
104Supply and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
105Supply and fixing brass batten/ angle holder including connection etc. as required.
106Providing and fixing 63 Amp TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc.
107Supplying and fixing 12 way, Double door, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).
108Supply and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of single pole in the existing MCB DB complete with connections, testing and commissioning etc. as required.of 16amp.
109Supply and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of single pole in the existing MCB DB complete with connections, testing and commissioning etc. as required.of 5amp.
110Supplying and fixing3 pin 5/6 amps Piano socket outlet on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
111Supplying and fixing 6 pin 15/16 amps Piano socket outleton the existing modular plate & switch box including connections but excluding modular plate etc. as required.
112Supplying and drawing 2x2.5 Sqm mm of FR PVC insulatedcopper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required.
113Supply, fixing, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FR PVC insulated, copper conductor, single core cable etc. as required.
114Supply, fixing,testing and commissioning of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required Upto 450 mm sweep.
115Earthing with GI earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pippe of 2.7 metre long etc. (but with charcoal/ coke and salt) as required.
116Wiring for for light/power plug with 4x4sqmm FR PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit along with 2 Nos 4sqmm FR PVC insulated copper conductor single core cable for loop earthing as required
117Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
118Supply, fixing,testing and commissioning of 20 watt LED fluorescent fitting / compact fluorescent fitting of all types, with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FR PVC insulated, copper conductor,single core cable and earthing etc. as required.
119SCHEDULE ‘A’ PART - XI (Addn/Altn of existing Single Offrs accommodation Bldg No. AR/Offr/COB/01)
120Repair to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sqm and under incl cutting the patch in proper shape, racking out joints and plastering the surface of the walls, including disposal of rubbish to the dumping ground within 50m lead etc. complete with CM 1:4( 1 cement : 4 coarse sand).
121Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead for thickness of tiles 10 mm to 25 mm.
122Providing and laying vitrified floor tiles in sizes 600mm x 600mm(thickness to be specified by the manufacturer) with water absorption less than 0.08%, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.
123Providing and laying Vitrified tiles in sizes 600 x 600mm (thickness to be specified by manufacturer), of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete
124Providing and laying Polished Granite stone flooring in required design of Black,Cherry/Ruby Red or equivalent colour and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge
125Providing and laying of ceramic glazed wall tiles of approved makein all colours of any size in walls/skirting over 12 mm thick bed ofCM (1:3) and jointing with grey cement slurry @ 3.3 kg per sqm incl pointing the joints with white cement complete.
126Finishing walls with Acrylic Smooth exterior paint with silicone additive of required shade on new work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm).
127Providing and finishing with two or more coats applied @ 1.43 ltr/10 Sqm over existing cement paint surface Premium Acrylic smooth exterior paint with silicon additives of required shadeincluding removing of old water proofing cement paint by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc complete.
128Providing and applying white cement based putty of average thickness 1mm, of approved brand and manufacturer , over the plastered wall surface to prepare the surface even and smooth complete.
129Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on new work (two or more coats) over and including water thinnable priming coat with cement primer.
130Distempering with oil bound washable distemper approved brand and manufacturer to given an even shad in old work (one or more coats) incl preparation of old surface by removing old paint by scrapping, sand papering incl necessary repairs to scratches etc complete.
131Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade,One or more coats on old work.
132Half brick work with common burnt clay F.P.S (non modular) bricks of class designation 7.5 in superstructure in plinth level in Cement mortar 1:4 (1 cement : 4 coarse sand).
133Providing and laying 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix 1:4 (1 cement : 4 fine sand)
134Providing and laying in position cement concrete of 1:3:6 with 20 mm graded stone aggregates including centering and shuttering etccomplete in drain.
135Providing and making plinth protection 50 mm thick of cement concrete (1:3:6) with stone aggr 20 mm nominal size) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth.
136Dismantling cement asbestos sheets or other hard board in ceiling,including stacking of serviceable materials and disposal of unserviceable materials within 50 metres lead.
137Dismantling wood work in frames, trusses, purlins and rafters up to 10 metres span and 5 metres height including stacking the material within 50 metres lead.
138Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angleof size24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting /making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge of GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8mm drop; made of G I sheet having galvanizing of 100gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns(minimum), including factory painted after bending.
139Dismantling roofing of GS Sheet roofing,including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres.
140Providing and fixing of PPGI profile Sheet of 0.50mm (+0.05%) total coated thickness with zinc coating 120 gm per sqm in 240 mpa steel grade, 5-7 microns epoxy primer on both sides of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scrateches during transportation and should be supplied single length upto 12m or as desired by Engineer - In - Charge . The sheets should be fixed using self drilling/ self tapping screws of size 5.5x55mm with EPDM seal, complete to the existing truss and purlins etc complete.
141Providing and fixing PPGI sheet ridges or hips of width (500- 600mm) overall width plainsheet of 0.50 mm (+0.05%) total thickness , zinc coating fixed 120grms per sqm as per IS :277 using self drilling or self tapping screws complete.
142Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead of area 3 sq. metres and below.
143Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with inbuilt roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.Three track three panels sliding window made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension.
144Providing and fixing fly proof wire gauge to windows, doors and ventilators with MS flat 15x3mm and nuts & bolts completeof Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides.
145Renewing glass panes, with putty and nails wherever necessary including racking out the old putty with float glass panes of thickness 4 mm.
146Providing and fixing 35mm thick factory made laminated flush door shutters decorative type, core of block boards construction with frame of 1st class hard wood including stainless steel butt hinges with screws etc complete.
147Providing and fixing of mosquito proof shutters using galvanized MS wire gauge of average width of aperature 1.4mm in both directions with wire of dia 0.63mm for door of 35mm with 2nd class teak wood.
148Providing and fixing aluminium handles of size : 100 mm, transparent or dyed to required colour or shade, with necessary screws etc. complete
149Providing and fixing aluminium tower bolts of size : 100x10 mm with necessary screws etc. Complete.
150Supply and fixing aluminum sliding door bolts, transparent or dyed to required colour or shade, with nuts and screws etc complete of size 250x16mm.
151Providing and fixing factory made 30 mm thick door shutter made of solid PVC foam profile Decorative finish (both side wood grained finish). The styles & rails shall be of size 75 mm x 30 mm having wall thickness 5 mm. The styles, top & bottom rails shall have one side wall thickness of 15 mm integrally extruded on the hinge side of the profile for better screw holding power. The styles and rails shall be reinforced with M.S. tubes of size 33 mm x 17 mmx 1 mm, painted with primer , all four corners of reinforcement to be welded or sealed. Solid PVC extruded bidding (push fit type) will be set inside the styles and the rails with a cavity, to receive single piece extruded 5mm PVC sheet as panel. The styles and rails will be mitred cut and joint with the help of PVC solvent cement & self driven self tapping screws. Single piece extruded solid PVC lock rail of size 100 mm x 30 mm with wall thickness 5 mm & 15 mm integrally extruded in the middle of the lock rail & fixed with styles with the help of PVC solvent cement & self driven self tapping screws of size 100mm x 8 mm complete as per manufacturer"s specifications and direction of Engineer-in-charge.
152Providing and fixing nickel plated M.S. pipe curtain rods with nickel plated bracketsof 25 mm dia (heavy type).
153Providing and fixing 20 mm nominal dia CPVC pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints completeas per direction of Engineer in Charge
154Providing and fixing 15 mm nominal dia CPVC pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints completeas per direction of Engineer in Charge
155Providing and fixing 25 mm nominal dia CPVC pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge
156Providing and fixing of 15mm nominal bore CP bib cock of approved quality.
157Providing and fixing of 20 mm dia brass stop cock of approved quality etc. Complete.
158Providing and fixing 15mm nominal bore C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.
159Providing and fixing of PTMT towel rail ring trapezoidal shape 215mm long, 200mm wide with minium distances of 37mm from wall face with concesled fittings arrangement of approved qaulity of 600mm long.
160Providing and fixing White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required.
161Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings.
162Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing of Rectangular shape 1500x450 mm.
163Providing and fixing on wall unplasticised rigid PVC pipes incl jointing with seal ring, single socketed pipes of 110 mm dia.
164Providing and fixing on wall unplasticised rigid PVC pipes incl jointing with seal ring, single socketed pipes of 75 mm dia.
165Construction of brick masonry manhole in cement mortar (1:4) with RCC top slap with (1:2:4) mix foundation concrete (1:4:8) mix inside plastering 12 mm thick with CM (1:3) finished with floating coat of neat cement and making channel in cement concrete (1:2:4) etc complete with common burnt clay FPS (non modular) bricks.
166Providing and fixing of 15mm nominal bore CP angle cock of approved quality.
167Providing and fixing 25mm nominal bore gun metal gate valve with CI wheel of approved quality ( screwed end)
168Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable and 1.5 sq.mm. FR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required (Group B) .
169Supply and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
170Supplying and fixing 5/6 amps modular switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
171Supplying and fixing 15/16 amps modular switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
172Supply and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
173Supply and fixing brass batten/ angle holder including connection etc. as required.
174Providing and fixing 63 Amp TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc.
175Supplying and fixing 8 way, Double door, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).
176Supply and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of single pole in the existing MCB DB complete with connections, testing and commissioning etc. as required.of 16amp.
177Supply and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of single pole in the existing MCB DB complete with connections, testing and commissioning etc. as required.of 5amp.
178Supplying and fixing3 pin 5/6 amps modular socket outlet on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
179Supplying and fixing 6 pin 15/16 amps modular socket outleton the existing modular plate & switch box including connections but excluding modular plate etc. as required.
180Supplying and drawing 2x2.5 Sqm mm of FR PVC insulatedcopper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required.
181Installation,testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FR PVC insulated, copper conductor, single core cable etc. as required.
182Installation,testing and commissioning of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required Upto 450 mm sweep.
183Earthing with GI earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pippe of 2.7 metre long etc. (but without charcoal/ coke and salt) as required.
184Wiring for for light/power plug with 4x4sqmm FR PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit along with 2 Nos 4sqmm FR PVC insulated copper conductor single core cable for loop earthing as required
185Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
186Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc complete as required.
187Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run).
188Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
189Supply, fixing,testing and commissioning of 20 watt LED fluorescent fitting / compact fluorescent fitting of all types, with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FR PVC insulated, copper conductor,single core cable and earthing etc. as required.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail