Tender For Repair/ Replacement To Internal Electrical Including Light, Summer Appliances, Exhaust Fan, Fittings And Fixtures And All Connected Items Omqs And Otms At Hq Tc Bangalore, bangalore-Karnataka

Military Engineer Services-MES has published Tender For Repair/ Replacement To Internal Electrical Including Light, Summer Appliances, Exhaust Fan, Fittings And Fixtures And All Connected Items Omqs And Otms At Hq Tc Bangalore. Submission Date for this Tender is 11-05-2024. Electrical Maintenance Tenders in bangalore Karnataka. Bidders can get complete Tender details and download the document.




Tender Notice

43205467
Tender For Repair/ Replacement To Internal Electrical Including Light, Summer Appliances, Exhaust Fan, Fittings And Fixtures And All Connected Items Omqs And Otms At Hq Tc Bangalore
Open Tender
Indian
Karnataka
bangalore
11-05-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Repair / Replacement To Internal Electrical Including Light, Summer Appliances, Exhaust Fan, Fittings And Fixtures And All Connected Items Omqs And Otms At Hq Tc Bangalore-Taking Down Ceiling Fansfrom Ceiling, Dismantaling Blades &Refixing Ofthe Same Includingand Connecting Up Includingprovision Of Cable From Ceiling Rose Or Connector To Fan Complete All As Specified And Directed. Note:- Servicing & Overhauling, Rewinding, Painting &Replacement Of Defective Spare Part, Connecting Wire Etc Shall Be Measured & Paid Separately 2 M&Lpainting Of Ceiling Fans Complete In Situ With Synthetic Enamel Paint By Spraying Including Filling Cavities With Filler, One Coat After Cleaning All Dust Etc Complete All As Specified And Directed. 3 Rewinding Of Ceiling Fan1200 / 1400Mm Sweep And Dismantling The Ceiling Fan, Removing The Burnt Winding, Cleaning Slot, Replacement Of Defective Nut Bolts Washer Etc And Rewinding With Using Appropriate Size Of Super Enamelled Copper Winding Wire Thermal Class-E, Including Varnishing Complete All As Specified And Directed. 4 Servicing & Overhaulingonly Of Ceiling Fanat Site By Oiling / Greasing To Reduce The Noice Of The Fans And Connecting The Same Complete All As Specified And As Directed. 5 S&F Repairs Ball Bearing 6201 / 6202 / 6203 As Per Site Requirement Complete All As Specified And As Directed. 6 S&F In Repairscapacitors 1.5 Mfd Forfans Complete All As Specified And As Directed. 7 S&F In Repairs Capacitors 2.5 Mfd Forfans Complete All As Specified And As Directed. 8 S&F In Repairs Stepped Type Electronic Fan Regulator Flush Type 300 Watts With 5 Step Speed Control For Fans Any Sweep 1200 Mm / 1400 Mm Fixed As In Repair Complete All As Specified And Directed 9 S&F In Repairs Down Rod 3 Feet Length Suitable For Ceiling Fans Complete All As Specified And As Directed. 10 Taking Down Exhaust Fans, Of Any Size Or Any Capacity 250 / 300 / 350 / 400 Mm Sweepdismantaling Blades &Refixing Ofthe Same Includingand Connecting Up Includingprovision Of Cable From Ceiling Rose Or Connector To Fan All As Specified And Directed. Note:- Servicing & Overhauling, Rewinding, Painting &Replacement Of Defective Spare Part, Connecting Wire Etc Shall Be Measured & Paid Separately 11 M&L Painting Ofexhaust Fans Of Any Size Or Any Capacity 250 / 300 / 350 / 400 Mm Sweep Complete In Situ With Synthetic Enamel Paint By Spraying Including Filling Cavities With Filler, One Coat After Cleaning All Dust Etc Complete All As Specified And As Directed. 12 Rewinding Of Exhaust Fan 250 / 300 / 350 / 400 Mm Sweep And Dismantling The Ceiling Fan, Removing The Burnt Winding, Cleaning Slot, Replacement Of Defective Nut Bolts Washer Etc And Rewinding With Using Appropriate Size Of Super Enamelled Copper Winding Wire Thermal Class-E, Including Varnishing Complete All As Specified And As Directed. 13 Servicing & Overhaulingonlyof Exhaust Fan 250 / 300 / 350 / 400 Mm Sweepat Site By Oiling / Greasing To Reduce The Noice Of The Fans And Connecting The Same Complete All As Specified And As Directed. 14 S&F Repairs Exhaust Fan By Replacement Of Bearing / Bush Of Any Sizeas Per Site Requirement Complete All As Specified And As Directed. 15 S&F Repairsexhaust Fan Capacitors 2.5 Mfd Forfans All As Specified And Directed 16 S&F Exhaust Fan Blades Of Pvc Body Of Any Size Fixed As In Repair Complete All As Specified And Directed 17 S&F Exhaust Fan Blades Of Metal Body Up To 300 Mm Sweep Size Fixed As In Repair Complete All As Specified And Directed 18 S&F In Repairs Of Exhaust Fan Louvers Of Any Size To Be Fixed In Repair, Placement , Taking Down From Any Height Of Building Complete All As Specified And As Directed. 19 S&F In Repairs Of Exhaust Fan Capacitors 4 Mfd .For Exhaust Complete All As Specified And As Directed. 20 Taking Down Wall Mounted Fansfrom Walls , Dismantaling Blades &Refixing Ofthe Same Includingand Connecting Up Includingprovision Of Cable From Ceiling Rose Or Connector To Fan Complete All As Specified And As Directed.Note:- Servicing & Overhauling, Rewinding, Painting &Replacement Of Defective Spare Part, Connecting Wire Etc Shall Be Measured & Paid Separately 21 Rewinding Of Wall Mounted Fan Of Anysweep And Dismantling The Ceiling Fan, Removing The Burnt Winding, Cleaning Slot, Replacement Of Defective Nut Bolts Washer Etc And Rewinding With Using Appropriate Size Of Super Enamelled Copper Winding Wire Thermal Class-E, Including Varnishingcomplete All As Specified And As Directed. 22 S&F Fan Hook On Rcc Ceilingmade Of Mild Steel Back Plate , Hook And Mounting With Two Nos Expandable Anchor Bolts And Tightening Nuts Including Making Necessary Holes, Fixed As In Repairs, Complete All As Specified And Directed 23 S&F In Repairs Pvc Canopies For Ceiling Fan 1200 / 1400 Mm Sweep, Complete All As Specified And Directed. 24 S&F Led Light Fitting 2 Feet, 10 Watts, 220 Volts, Ac Decorative Box Type With Driver, Holder Including Led Tube Light Connecting Up With 2 Core Flexiblecopper Conductor Cable Of Suitable Size From Ceiling Rose Complete All As Specified And Directed. 25 S&F Led Light Fitting, 20 Watts Led Luminaire Comprises Of Extruded Channel, High Translucent Glare Free And Connecting Up With 2 Core Flexiblecopper Conductor Cable Of Suitable Size From Ceiling Rose Complete All As Specified And Directed.Make : Bajal / Philips / Havells 26 S&F 2 Core Flexible Copper Cable For Connecting From Ceiling Rose To Fans Etc Complete All As Specified And Directed. 27 S&F 15 Watts Led Light Fitting Downlighter, Panel Round Glare Free Light Complete All As Specified And Directed. Make : Bajaj / Philips / Havells / Cg 28 S&F 12 Watts Led Light Fitting Downlighter, Panel Square Glare Free Light Complete All As Specified And Directed.Make : Bajaj / Philips / Havells / Cg 29 S&F10 Watts Led Bulkhead Light Fitting, Ip 65 Protection, Polycarbonatelight Complete All As Specified And Directed. Make : Bajaj / Philips / Havells / Cg 30 Material & Labour Servicing Of Defective Solar Water Heater 100 Litres Capacity With Electric Back Up System After Disconnecting The Existing Water Supply / Electrical Connections From Any Height Of The Building, Including Stripping Out The Hot Water Vessel By Taking Out The Outer Cover, Insulating Materials Etc. And Continuous Brazing Of The Inner Container For Arresting Leakages Including Replacement Of Defective / Worn Out Spare Parts And Re-Assembling The System And Re-Installed At The Same Location, Connecting Up Water / Electrical Connections And Testing For Satisfactory Performance Complete All As Specified And As Directed. 31 All As Per Item No 30.00 Above But For 200 Litres Capacity. 32 All As Per Item No 30.00 Above But For 300 Litres Capacity. 33 S&F In Repair Back Up Kit Of Solar Water Heater Upto3 Kw Complete All As Specified And As Directed. 34 S&F In Repair5mm Thick Toughened Plain Glass Panels Suitable For Solar Water Heater Plate Collector Box, Suitable For Existing Make Complete All As Specified And As Directed. 35 S&F In Repair Heating Element 1.50 Kw With Rubber Gasket Threaded / Push Type 230V For Geyser, Isi Marked Complete All As Specified And As Directed. 36 S&F In Repair Heating Element 2.00 Kw With Rubber Gasket Threaded / Push Type 230V For Geyser, Isi Marked Complete All As Specified And As Directed. 37 S&F In Repairheating Element 3.00 Kw With Rubber Gasket Threaded / Push Type 230V For Geyser, Isi Marked Complete All As Specified And As Directed. 38 M&L Cleaning Of Solar Tank 100 Ltr Capacity By Providing Chemical & Removing All Scale / Dirt / Dust Etc Disconnecting The Existing Water Supply / Electrical Connections From Any Height Of The Building, Connecting Up Water / Electrical Connections And Testing For Satisfactory Performance Complete All As Specified And As Directed. 39 All As Per Item No 38.00 Above But 200 Ltrs Capacitycomplete All As Specified And As Directed. 40 All As Per Item No 38.00 Above But 300 Ltrs Capacitycomplete All As Specified And As Directed. 41 S&Fm Sealphataphat Packing Size 25 Gram Each Packetcomplete All As Specified And As Directed. 42 S&F Metal Paste Each Paking In 500 Grams Complete All As Specified And As Directed. 43 S&F In Repair Of Copper Flexible Cable 3 Core 2.5 Sqmm Pvc Frls Insulated And Sheathed 1100 Volts Gradecomplete All As Specified And As Directed. 44 S&F In Repairthermostat Suitable For Solar Water Heatercomplete All As Specified And As Directed. 45 Taking Down &Refixing Only Geyser 50 / 25 Ltrs Capacity After Repairs In New Position Including Drilling Holes On Wall , Fixing Four Nos Anchor Bolts, Nuts And Washersand Connecting To The Water And Electric Connections And Testing Complete All As Specified And As Directed. 46 Servicing Of Storage Type Electric Water Heater ( Geyser ) Of Capacity 15 / 25 Litres Comprising Of The Following Works: - ( I ) Taking Down Geysers From Existing Positionafter Disconnecting All Electrical & Water Supply Connection. ( Ii ) Opening / Dismantling & Cleaning Of All Parts & Checking For Its Serviceability. ( Iii ) Cleaning / Descaling Of Thermostat & Inner Tank With Descaling Solution & Water Leakage Testing Of Tank & Rectification Of Leakage. ( Iv ) Checking Of Pressure Reducing Valves & Non Return Valve Etc. To Ensures Free Movement / Smooth Operation Of These Components. ( V ) Checking Of Overflow / Vent Pipes And Removing Blockages / Obstructions If Any. ( V ) Reassembling The Geyser, Replacement Of Minor Spare Part Such As Nut, Bolt, Screw, Rubber Packing Etc & Refixing In Same Position, Reconnecting With Electric & Water Supply Connection Complete All As Specified And As Directed. 47 S&F In Repairheating Element 1.50 Kw With Rubber Gasket Threaded / Push Type 230V For Solar Water Heater, Isi Markedcomplete All As Specified And As Directed.Make: Bajaj / Usha Isi Marked 48 S&F In Repairheating Element 2.00 Kw With Rubber Gasket Threaded / Push Type 230V For Solar Water Heater, Isi Marked All As Specified And As Directed.Make: Bajaj / Usha Isi Marked 49 S&F In Repairsafety Valve / High Pressure Valve Isi Marked Suitable For Geyser Of Any Capacitycomplete All As Specified And As Directed. 50 S&F In Repairthermostat Suitable For Geysers 25 To 50 Ltr Capacity And Range 30 To 80 Degree Centigrade And Cut Off At 70 Degree Centigradecomplete All As Specified And As Directed. 51 S&F In Repairofpvc Connection Pipe 15Mm Dia, 450Mm Long Heavy Duty For Hot / Cold Water With Two Brass Union And Washerscomplete All As Specified And As Directed. 52 S&F In Repairofpvc Connection Pipe 15Mm Dia , 600 Mm Long Heavy Duty For Hot / Cold Water With Two Brass Union And Washerscomplete All As Specified And As Directed. 53 S&F In Repairindicator Lamp Square / Round / Rectangular Type Suitable For Geysers Of 25 To 50 Ltr Capacitycomplete All As Specified And As Directed. 54 S&F Inner Assembly 25 Ltrs Geyser And Connecting To The Water And Electric Connections And Testingcomplete All As Specified And As Directed. 55 S&F Mcb Sheet Metal Enclosure With A Two Pin And Earth Plug And Socket Complete With One Single Pole Mcb, 20 A , 240 Voltsfor Geysercomplete All As Specified And As Directed. 56 S&F In Repairmodular Switch Socket Combination6 Pin, 16 Amps Multi Purpose, 3 Modulecomplete All As Specified And As Directed. 57 S&F In Repairof Switch Socket Combination 5 In 1, 3 Pin , 5 And 16 Amps Multi Purpose Flush Typeuniversal, With Indicator Complete All As Specified And Directed. 58 S&F In Repairof Mcb Sp, 6-40 Amps, 240Vcomplete All As Specified And As Directed. 59 S&F In Repair Of Mcb Spn, 40 Amps, 240V Complete All As Specified And As Directed. 60 Taking Down And Connecting The Electric Metersfrom Meter Board And Refixing The Same Including Connecting Up Andprovision Of Cablecomplete All As Specified And As Directed. 61 Servicing / Overhauling Of Electric Energy Meters Of Any Size / Any Capacity Including Testing Of Meters For Running Properly And Accuracy Including Load Testing With Proper Equipments Complete All As Specified And As Directed. 62 S&F In Repair Stepped Type Electronic Fan Regulator Flush Type With 5 Step Speed Control Complete All As Specified And Directed 63 S&F Modular White Cover Plate With Frame, 1 Module Complete All As Specified And Directed 64 S&Fmodular White Cover Plate With Frame, 2 Module Complete All As Specified And Directed 65 S&F Modular White Cover Plate With Frame, 3 Module Complete All As Specified And Directed 66 S&Fmodular White Cover Plate With Frame, 4 Module Complete All As Specified And Directed 67 S&F Modular White Cover Plate With Frame, 6 Module Complete All As Specified And Directed 68 S&Fmodular White Cover Plate With Frame, 8 Module Complete All As Specified And Directed 69 M&L Sub Main Wiring With Two Single Core Pvc Insulated Frls Cable With Copper Conductor Multistranded 1100 Volts Grade 2.50Sqmm In And Including Non-Metallic Rigid Pvc Casing And Capping Andaccessories And Fixing Arrangements Fixed To Surface On Wall, Floor Or Ceiling Etc Including 2.50 Sqmm Pvc Insulated Frls Multistranded Copper Earth Continuity Conductor And Connecting To Main Earth Dolly Complete All As Specified And Directed. Note : One Run Of Earth Continuity Conductor, One Run Of Pvc Casing Cappingand Two Run Of Copper Conductor Together Taken As One Length For Measuring Unit Length. 70 M&L Sub Main Wiring With Two Single Core Pvc Insulated Frls Cable With Copper Conductor Multistranded 1100 Volts Grade 4.00Sqmm In And Including Non-Metallic Rigid Pvc Casing And Capping Andaccessories And Fixing Arrangements Fixed To Surface On Wall, Floor Or Ceiling Etc Including4.00 Sqmm Pvc Insulated Frls Multistranded Copper Earth Continuity Conductor And Connecting To Main Earth Dolly Complete All As Specified And Directed.Note : One Run Of Earth Continuity Conductor, One Run Of Pvc Casing Cappingand Two Run Of Copper Conductor Together Taken As One Length For Measuring Unit Length. 71 S&F In Repairfan Regulater 120 W , 2 Module Complete All As Specified And Directed. 72 S&F In Repair Of Plug Top 3 Pin 16 Amps, 3 Pin Plug, 230 Volts Complete All As Specified And Directed. 73 S&F In Repair Of Plug Top 3 Pin 6 Amps, 3 Pin Plug, 230 Volts Complete All As Specified And Directed. 74 S&F In Repairs Led Surface Mounted Powder Coated Crca Housing 2Ft X 2Ft Liminarie Providing Uniform Illumination 36 Watts, Complete All As Specified And Directed. 75 S&F In Repairs Led High Wattage Bldg Security Lamps 20 Watts, Complete All As Specified And Directed.

Key Value

Document Fees
INR 500 /-
EMD
INR 62000.0 /-
Tender Value
INR 31 Lakhs /-

Attachment

FileName File Description File Size
38bfb620-b8f1-4c65-8d4d-68587f2f6e86.html Tender Notice 0 KB
BOQ_728267.xls Tender Document 0 KB
Tender8201.pdf Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

Name of Work : REPAIR/ REPLACEMENT TO INTERNAL ELECTRICAL INCLUDING LIGHT, SUMMER APPLIANCES, EX FAN, FITTINGS AND FIXTURES AND ALL CONNECTED ITEMS OMQs AND OTMs at HQ TC BANGALORE.
Sl. No. Item Description
1Taking down ceiling fansfrom ceiling, dismantaling blades &refixing ofthe same includingand connecting up includingprovision of cable from ceiling rose or connector to fan complete all as specified and directed. Note:- Servicing & overhauling, rewinding,Painting &replacement of defective spare part, connecting wire etc shall be measured & paid separately
2M&LPainting of ceiling fans complete in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc complete all as specified and directed.
3Rewinding of ceiling fan1200/1400mm sweep and dismantling the ceiling fan, removing the burnt winding, cleaning slot, replacement of defective nut bolts washer etc and rewinding with using appropriate size of super enamelled copper winding wire thermal class-E, including varnishing complete all as specified and directed.
4Servicing & Overhaulingonly of ceiling fanat site by oiling/ greasing to reduce the noice of the fans and connecting the same complete all as specified and as directed.
5S&F Repairs Ball Bearing 6201/6202/6203 as per site requirement complete all as specified and as directed.
6S&F in Repairscapacitors 1.5 mfd forfans complete all as specified and as directed.
7S&F in Repairs capacitors 2.5 mfd forfans complete all as specified and as directed.
8S&F in Repairs stepped type electronic fan regulator flush type 300 watts with 5 step speed control for fans any sweep 1200 mm/1400 mm fixed as in repair complete all as specified and directed
9S&F in Repairs down rod 3 feet length suitable for ceiling fans complete all as specified and as directed.
10Taking down Exhaust fans, of any size or any capacity 250/300/350/400 mm sweepdismantaling blades &refixing ofthe same includingand connecting up includingprovision of cable from ceiling rose or connector to fan all as specified and directed. Note:- Servicing & overhauling, rewinding,Painting &replacement of defective spare part, connecting wire etc shall be measured & paid separately
11M&L Painting ofExhaust fans of any size or any capacity 250/300/350/400 mm sweep complete in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc complete all as specified and as directed.
12Rewinding of Exhaust fan 250/300/350/400 mm sweep and dismantling the ceiling fan, removing the burnt winding, cleaning slot, replacement of defective nut bolts washer etc and rewinding with using appropriate size of super enamelled copper winding wire thermal class-E, including varnishing complete all as specified and as directed.
13Servicing & Overhaulingonlyof Exhaust fan 250/300/350/400 mm sweepat site by oiling/ greasing to reduce the noice of the fans and connecting the same complete all as specified and as directed.
14S&F Repairs Exhaust fan by replacement of Bearing/ bush of any sizeas per site requirement complete all as specified and as directed.
15S&F RepairsExhaust Fan capacitors 2.5 mfd forfans all as specified and directed
16S&F exhaust fan blades of PVC body of any size fixed as in repair complete all as specified and directed
17S&F exhaust fan blades of metal body up to 300 mm sweep size fixed as in repair complete all as specified and directed
18S&F in repairs of exhaust fan louvers of any size to be fixed in repair, placement , taking down from any height of building complete all as specified and as directed.
19S&F in repairs of Exhaust fan capacitors 4 mfd .for exhaust complete all as specified and as directed.
20Taking down Wall Mounted fansfrom walls , dismantaling blades &refixing ofthe same includingand connecting up includingprovision of cable from ceiling rose or connector to fan complete all as specified and as directed. Note:- Servicing & overhauling, rewinding,Painting &replacement of defective spare part, connecting wire etc shall be measured & paid separately
21Rewinding of Wall mounted fan of anysweep and dismantling the ceiling fan, removing the burnt winding, cleaning slot, replacement of defective nut bolts washer etc and rewinding with using appropriate size of super enamelled copper winding wire thermal class-E, including varnishingcomplete all as specified and as directed.
22S&F Fan hook on RCC ceilingmade of mild steel back plate , hook and mounting with two Nos expandable anchor bolts and tightening nuts including making necessary holes, fixed as in repairs, complete all as specified and directed
23S&F in Repairs PVC Canopies for ceiling fan 1200/1400 mm sweep, complete all as specified and directed.
24S&F LED Light fitting 2 feet, 10 Watts, 220 volts, AC decorative box type with driver, holder including LED tube light connecting up with 2 core flexiblecopper conductor cable of suitable size from Ceiling rose complete all as specified and directed.
25S&F LED Light fitting, 20 Watts LED Luminaire comprises of extruded channel, high Translucent glare free and connecting up with 2 core flexiblecopper conductor cable of suitable size from Ceiling rose complete all as specified and directed. Make : BAJAL/PHILIPS/ HAVELLS
26S&F 2 core flexible copper cable for connecting from Ceiling rose to fans etc complete all as specified and directed.
27S&F 15 Watts LED Light fitting Downlighter, Panel Round glare free light complete all as specified and directed. Make : BAJAJ/PHILIPS/ HAVELLS/ CG
28S&F 12 Watts LED Light fitting Downlighter, Panel Square glare free light complete all as specified and directed. Make : BAJAJ/PHILIPS/ HAVELLS/ CG
29S&F10 Watts LED bulkhead Light fitting, IP 65 protection, polycarbonatelight complete all as specified and directed. Make : BAJAJ/PHILIPS/ HAVELLS/ CG
30Material & Labour Servicing of defective solar water heater 100 litres capacity with electric back up system after disconnecting the existing water supply/ electrical connections from any height of the building,including stripping out the hot water vessel by taking out the outer cover, insulating materials etc. and continuous brazing of the inner container for arresting leakages including replacement of defective / worn out spare parts and re-assembling the system and re-installed at the same location, connecting up water/ electrical connections and testing for satisfactory performance complete all as specified and as directed.
31All as per item No 30.00 above but for 200 litres capacity.
32All as per item No 30.00 above but for 300 litres capacity.
33S&F in repair back up kit of solar water heater upto3 KW complete all as specified and as directed.
34S&F in repair5mm thick toughened plain glass panels suitable for solar water heater plate collector box,suitable for existing make complete all as specified and as directed.
35S&F in repair Heating element 1.50 KW with rubber gasket threaded/ push type 230V for Geyser, ISI Marked complete all as specified and as directed.
36S&F in repair Heating element 2.00 KW with rubber gasket threaded/ push type 230V for Geyser, ISI Marked complete all as specified and as directed.
37S&F in repairHeating element 3.00 KW with rubber gasket threaded/ push type 230V for Geyser, ISI Marked complete all as specified and as directed.
38M&L cleaning of solar tank 100 ltr capacity by providing chemical & removing all scale / dirt / dust etc disconnecting the existing water supply/ electrical connections from any height of the building,connecting up water/ electrical connections and testing for satisfactory performance complete all as specified and as directed.
39All as per item No 38.00 above but 200 ltrs capacitycomplete all as specified and as directed.
40All as per item No 38.00 above but 300 ltrs capacitycomplete all as specified and as directed.
41S&FM sealphataphat packing size 25 gram each packetcomplete all as specified and as directed.
42S&F Metal paste each paking in 500 grams complete all as specified and as directed.
43S&F in repair of copper flexible cable 3 core 2.5 sqmm PVC FRLS insulated and sheathed 1100 volts gradecomplete all as specified and as directed.
44S&F in repairthermostat suitable for solar water heatercomplete all as specified and as directed.
45Taking down &Refixing only geyser 50/25 ltrs capacity after repairs in new position including drilling holes on wall ,fixing four Nos anchor bolts,nuts and washersand connecting to the water and electric connections and testing complete all as specified and as directed.
46Servicing of storage type electric water heater (geyser) of capacity 15 /25 litres comprising of the following works: - (i) Taking down geysers from existing positionafter disconnecting all electrical & water supply connection. (ii) Opening / dismantling & cleaning of all parts & checking for its serviceability. (iii) Cleaning / descaling of thermostat & inner tank with descaling solution & water leakage testing of tank & rectification of leakage. (iv) Checking of pressure reducing valves & non return valve etc. to ensures free movement / smooth operation of these components. (v) Checking of overflow / vent pipes and removing blockages / obstructions if any. (v) Reassembling the geyser, replacement of minor spare part such as nut, bolt, screw, rubber packing etc & refixing in same position, reconnecting with electric & water supply connection complete all as specified and as directed.
47S&F in repairHeating element 1.50 KW with rubber gasket threaded/ push type 230V for solar water heater, ISI Markedcomplete all as specified and as directed. Make: BAJAJ/ USHA ISI Marked
48S&F in repairHeating element 2.00 KW with rubber gasket threaded/ push type 230V for solar water heater, ISI Marked all as specified and as directed. Make: BAJAJ/ USHA ISI Marked
49S&F in repairsafety valve / high pressure valve ISI marked suitable for geyser of any capacitycomplete all as specified and as directed.
50S&F in repairthermostat suitable for geysers 25 to 50 ltr capacity and range 30 to 80 degree centigrade and cut off at 70 degree centigradecomplete all as specified and as directed.
51S&F in repairofPVC connection pipe 15mm dia,450mm long heavy duty for hot /cold water with two brass union and washerscomplete all as specified and as directed.
52S&F in repairofPVC connection pipe 15mm dia , 600 mm long heavy duty for hot /cold water with two brass union and washerscomplete all as specified and as directed.
53S&F in repairindicator lamp square/ round / rectangular type suitable for geysers of 25 to 50 Ltr capacitycomplete all as specified and as directed.
54S&F inner assembly 25 ltrs geyser and connecting to the water and electric connections and testingcomplete all as specified and as directed.
55S&F MCB sheet metal enclosure with a two pin and earth plug and socket complete with one single pole MCB, 20 A , 240 Voltsfor geysercomplete all as specified and as directed.
56S&F in repairModular Switch socket combination6 pin,16 amps multi purpose, 3 modulecomplete all as specified and as directed.
57S&F in repairof Switch socket combination 5 in 1, 3 pin ,5 and 16 amps multi purpose flush typeuniversal, with indicator complete all as specified and directed.
58S&F in repairof MCB SP, 6-40 Amps, 240Vcomplete all as specified and as directed.
59S&F in repair of MCB SPN, 40 Amps, 240V complete all as specified and as directed.
60Taking down and connecting the electric metersfrom meter board and refixing the same including connecting up andprovision of cablecomplete all as specified and as directed.
61Servicing/ overhauling of Electric energy meters of any size/ any capacity including testing of meters for running properly and accuracy including load testing with proper equipments complete all as specified and as directed.
62S&F in repair stepped type electronic fan regulator flush type with 5 step speed control complete all as specified and directed
63S&F modular white cover plate with frame, 1 module complete all as specified and directed
64S&Fmodular white cover plate with frame, 2 module complete all as specified and directed
65S&F modular white cover plate with frame, 3 module complete all as specified and directed
66S&Fmodular white cover plate with frame, 4 module complete all as specified and directed
67S&F modular white cover plate with frame, 6 module complete all as specified and directed
68S&Fmodular white cover plate with frame, 8 module complete all as specified and directed
69M&L Sub main wiring with Two single core PVC insulated FRLS cable with copper conductor multistranded 1100 volts grade 2.50sqmm in and including non-metallic rigid PVC casing and capping andaccessories and fixing arrangements fixed to surface on wall, floor or ceiling etc including 2.50 sqmm PVC insulated FRLS multistranded copper earth continuity conductor and connecting to main earth dolly complete all as specified and directed. Note : One run of earth continuity conductor,one run of PVC casing cappingand two run of copper conductor together taken as one length for measuring unit length.
70M&L Sub main wiring with Two single core PVC insulated FRLS cable with copper conductor multistranded 1100 volts grade 4.00sqmm in and including non-metallic rigid PVC casing and capping andaccessories and fixing arrangements fixed to surface on wall, floor or ceiling etc including4.00 sqmm PVC insulated FRLS multistranded copper earth continuity conductor and connecting to main earth dolly complete all as specified and directed. Note : One run of earth continuity conductor,one run of PVC casing cappingand two run of copper conductor together taken as one length for measuring unit length.
71S&F in repairFan Regulater 120 W , 2 module complete all as specified and directed.
72S&F in repair of plug top 3 pin 16 amps, 3 Pin Plug, 230 volts complete all as specified and directed.
73S&F in repair of plug top 3 pin 6 amps, 3 Pin Plug, 230 volts complete all as specified and directed.
74S&F in repairs LED Surface mounted powder coated CRCA housing 2ft x 2ft liminarie providing uniform illumination 36 Watts,complete all as specified and directed.
75S&F in repairs LED High Wattage bldg security Lamps 20 Watts, complete all as specified and directed.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail