Madhyanchal Vidut Vitran Nigam Limited has published Tender For For 5Nos.250 Kva New Substation Shanker Nagar, Near Maunt Marry School, Basant Park And Kalpana Apartment And Modern School And1 No. 400 Kva T/F Near Subhas Park And I/C Of T/F250 To 400 Kva 2 No. At Kankata Park Kapurthala & Pragati Bazar Kapu. Submission Date for this Tender is 24-04-2024. Feeder Pillar Tenders in mahanagar Uttar Pradesh. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Safe Loading carriage & unloading of following material from central store to JE Store/work site. |
2 | ST pole 11/9 mtr |
3 | 11/0.4 KV 250KVA T/F |
4 | 11/0.4 KV 400KVA T/F |
5 | LT Cable 1x240//630/ 400 sqmm |
6 | 11KV XLPE Cable 3x70 sqmm |
7 | 11KV XLPE Cable 3x120 sqmm |
8 | 11KV XLPE Cable 3x120/-70 sqmm Termination Kit |
9 | 11KV Polymer Insulator |
10 | 33KV Disc Insulator |
11 | 33KV Disc Fitting |
12 | 33KV Breaker |
13 | 33KV Control Pannel |
14 | ABC Cable 3x120/95/50/25sqmm |
15 | V Type X-Arm |
16 | 33KV Bus Isolator |
17 | Safe Carriage of 9/11 Mtr ST pole/PCC Pole from Dump site to pit site |
18 | Fabrication erection of substation type double pole on ST pole along with fixing of necessary clamp ,accessories required including supply and fixing of MS channel on top dropperwith arrangement of fixing of 3 Nos pin insulator as per RESPO specification ,making 11 KV Bus bar by single core PVC .Only pole and pin with insulator clamp nut bolt provided by department |
19 | Fabrication and fixing of V-Type x-arm on existing single/double pole mounting ofinsulator and making section for bifurcation of feeder only x-arm and insulator provided by department |
20 | Laying of LT Cable 1x240/400/630 sqmm with suitable size of Al lugall material provide by department |
21 | Hoisting of LT Cable on pole through GI Pipe required size clamping on pole only cable provided by department |
22 | Proper Jumpering of LT Cable on O/H Line |
23 | Making 11KV Bus bar on newly erected Double pole and tapping of 11KV line |
24 | Prepare proper space for construction of plinth |
25 | Construction of T/F plinth of size 2x2x1.2 Mtr with first class bricks and masonry work in the ratio 1:4 cement and course sand fiiling of structure completely as per norms with RCC Top 1:2:2 cement sand and course sand stone gritt with MS bar and MS channel for resting of T/F. All material provide by contractor exept T/F |
26 | Fabrication and fixing of wiremesh fencing around the11/0.4KV T/F and DP Box made as per requirement 2mtr height 45x45x5 mm angle frame and 1 No horizontal runner by 40x5 mm MS flat then welding of wiremeshon it50x25mm made of 12 SWG ,diagonal bracing of all the frame panel welded with MS flat 25x3mm support, grouting properly by cement concrete and course sand all material provided by contractor |
27 | Fabrication and fixing of DP box stand made of MS Angle ,grouting and plinthing of the same all material provided by contractor |
28 | Fabrication and fixing of Metallic Distribution Pillar boxon stand with Nut bolt made of 20 SWG BP Sheet with door 18 SWG BP Sheet ,with fixing of 2 Nos MS Angle for mounting of Fuse unitthen fixing of fuse unit500 Amp 650 Volt and 3 Nos copper Bus Bar and 1 No Al Busbarall material arrange by contractor |
29 | Earthingof Pipe type with 60 feet deep boring and providing Jindal make pipe "B" class 1" dia and GI strip 25x5 6mtr long attached with clamps and GI pipe |
30 | Laying of 11 KV cable 3 x70 sqmm in pukka road by digging of trench upto 1 Mtr Deep putting cable boxing with bricks and sand refilling of earth and proper ramming. |
31 | Laying of 11 KV cable 3 x120 sqmm in pukka road by digging of trench upto 1 Mtr Deep putting cable boxing with bricks and sand refilling of earth and proper ramming |
32 | Laying of 11 KV cable 3 x120 sqmm in pukka roadDouble circuit by digging of trench upto 1 Mtr Deep putting cable boxing with bricks and sand refilling of earth and proper ramming |
33 | Hoisting of cable will be passed throughGI pipe required size dulyclamped with pole at the bottom ,middle and top of the pole |
34 | High pressure testing of 11KV Cable by high pressure equipment |
35 | Proper jumpering of cable both side with supply system |
36 | Erection and commissioning of AB Conductor 3x120+1x95/50+1x16 sqmm and 3x95+1x70+1x16 sqmm on existing/ newly erected pole. The department shall supply only ABC. |
37 | Supply and fixing of clamps |
38 | Holding clamp |
39 | Bracing angle set |
40 | LT Clamp for pole with GI Strip and schckle insulator |
41 | Crimping Al Lugs 240/400/630 sqmm |
42 | Copper L-Piece for T/F |
43 | Nut bolts off size |
44 | Danger board with clamp |
45 | Sundry Item |
46 | Hume Pipe 150x2000mm |
47 | Pipe and cable holding clamp |
48 | Grouting binding nuzzling of stay set complete including fixing of necessary clamps accessories All Materialmaterial provided by contractor |
49 | Ordinary Earthing by MS Earth rod2500 mm longby GI wire all material provide by Contractor |
50 | Fixing and installation of 11KV /33KV O/D typeXLPE Jointing Kit ,olny jointing kit provide by department |
51 | Providing fabrication and fixing of DO Fuse set |
52 | Providing Fabrication and fixing of 11KV TPMO Set |
53 | Groutingof pole by cement course sand and brick ballast Civil material provided by Contractor |
54 | Painting of ST pole by 2 coat of red oxide and 2 coat of Al paint provided by contractor |
55 | Safe installation of 11/0.4 KV 250 KVA T/F its connection from 11KV line and LT line mounting of copper L-piece providing and fixing of al lugs Labour &T&P Provided by contractor |
56 | Safe installation of 11/0.4 KV 400 KVA T/F its connection from 11KV line and LT line mounting of copper L-piece providing and fixing of al lugs Labour &T&P Provided by contractor |
57 | Dismantling of 250 KVA T/F by opening of all the HT/LT Connection and its carriage upto JE Dump store /Central Store |
58 | Construction of plinth of size 2x1.5x0.9 mtr suitable for upper structure for VCB including grouting of anchor bolts in proper alignment and level including excavation of foundation base concreting in CC 1:6:12 cement,fine sand,brick ballast ,1st class brick work in cement morter of ratio 1:4 ratio 1:4:8 and RCC work in ratio 1:2:4 cement, course sand and stone gritt of 20 mm |
59 | Installation of 33 KV VCB complete work with making earth connection ,earth mat,earthing with GI strip 50x6mm including control wiring ,commissioning & testing only VCB provided by department |
60 | Dismantling of damaged 33 KV Bus Isolator from structure after opening from supply system |
61 | Assembling and installation of isolator adjusting of opening mechanism in proper alignment to ensure smooth operation |
62 | Fabrication of Isolator Structure3.5 Mtr height digging of two No pits of size 1.075x0.9x0.3 mtr providing stone pad at the bottom of the pit and grouting of two legs of the structure in CC (Cement ,course sand and stone gritt )of the ratio 1:4:8 in block of of 1.075x0.3 mtr including all civil material ,T&P complete in all respect .The work includes dragging ,shifting ,erecting of 2 legs with runner on proper alignment and level and plumb. Both plinth of the isolator structure shall be properly finished with smoothing of edges |
63 | Paing of all the structure by two coat of red oxide and two coat of Al enamel paint |
64 | Making 33KV Busbar by using 33KV Disc insulator with Disc fitting and Panther Conductor |
65 | Shifting carefully 33KV Control panel from outside to control room including fixing, bolting,& grouting |
66 | Proper connection of 33 KV Copper control Cable from panel to incoming VCB, earthing ,testing and commissioningonly VCB provide by department rest all material and labor provided by contractor |
67 | GST will be paid extra as per rule. |