| 1 | SCHEDULE \"A\" E/M ITEMS |
| 2 | Material & Labour for LT panel Board cubical outdoortype compact415 Volts AC 50 Hz, fabricated of Thermoplastic (Polycarbonate), insulated, shock proof, dust proof, water proof, anti-corrosive and confirming to IP 65/66 complete including aluminiumbus bar 400 Amps 4 strip mounted on porcelain insulated & enclosed in chamber & connection from incoming and out going with openable shutter both sides comprising of following :- (a) Aluminium Bus bar RYB and N of 400 Amp capacity one set(b) MCCB160 Amp FP 36 KA - 01 No (Incoming)(c) MCCB100/63 amp FP 25 KA- 4 Nos (out going)(d) Digital MFM with inbuilt RS-485 port indicating Currents, Voltage, Frequency (e) LED Indicating lamps for Main Suppy R\", Y\" B\"- 01 Set of 3 |
| 3 | Supply & Laying XLPE insulated, armoured heavy duty electric cable of 16 Sqmm 4 core size with aluminium conductor, 1100 volts grade of cross-sectional area, Complete all as specified & directed by Engineer-in-Charge.Make: Polycab/ Asian/ Gloster |
| 4 | Excavation in trenches not exceeding 1.5 Metre wide and not exceeding 1.5 Metre in depth and getting out any type of soil, Complete all as specified & directed by Engineer-in-Charge. |
| 5 | Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25cm thick, Complete all as specified & directed by Engineer-in-Charge. |
| 6 | Removing excavated material not exceeding 50 Metre and depositing where directed at a level not exceeding 1.5 Metre above the starting point, Complete all as specified & directed by Engineer-in-Charge. |
| 7 | Supply & Fixing of GI steel tubing light grade 80mm dia for laying in ground and road crossing along the pole in coping etc., for cable protection including necessary fittings, clamps for supports, etc., Complete all as specified & directed by Engineer-in-Charge.Make: - Tata/Jindal/Surya Prakash/Swastik |
| 8 | Material & Labour for cutting existing road/hard standing not exceeding 45cm x 45cm in wide & depth getting out excavated material for laying cable/GI tube, returning filling & well ramming watering finish suraface 10cm from top using PCC 1:3:6; including removal of surplase soil, Complete all as specified & directed by Engineer-in-Charge. |
| 9 | Supply and laying double wall corrugated (DWC) high density polythene pipes having corrugation on the outer wall and plain surface on the inner wall confirming to ISI 14930 ( Part I and II) for protection of underground cables of size 50mm outer dia with all fittings. laid in trenches / road/ nallah or fixed along wall. poles or laid under floor (including cutting floor/Road and making good to match with existing adjoining surface etc for cable protection, Complete all as specified & directed by Engineer-in-Charge.NOTE:- Excavation and earth work shall be measured and paid separately Make:- Rex/Poly/Gemini |
| 10 | Supply & Fixing LED street light of capacity 60 Watt, LM6 high pressure die cast aluminium housing, IP 66 protection, THD<20%, PF>0.95, Operating Voltage 140-270V AC, 50HZ, Complete all as specified & directed by Engineer-in-Charge.Make:- Wipro / Philips/Crompton Greaves. |
| 11 | Supply and fixing Octagonal Hot-Dip galvanized street light poles including Junction box with single/double arm bracket following specifications:- Height7 mtrs, Top dia 70mm, Bottom dia 130mm, sheet thickness 3mm, base plate 220mm x 220mm x 12mm, including one 3 phase terminal for connection of incoming and outgoing cable and including one MCB 6A SP, 10 KA mounted on base plate, fitted inside the slot given for junction including proper size of lugs, nuts & washers, RCC foundation & foundation bolt M20 x 750 x 4 Nos as per OEM specifications or as directed by Engineer-in-Charge. Make:- Utkarsh/Bajaj /India tube and co/ India electric poles mfg co / Bombay tubes/ The national tubing co/ Kalinga tubes/ Singh profile |
| 12 | Supply, laying & testing PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 1.5 Sqmm, 3 core, 1100 Volts grade, Complete all as specified & directed by Engineer-in-Charge.Make:- Plaza/ Finolex/ Anchor/ Havells/ L&T/ POLYCAB |
| 13 | Supply and fixing automatic timer operated solar panel cleaning system (Total Panel-177) including pipe, elbowe, bend, tee, coupler, sprayers and electrical wiring with following materials :-(i) 1 inch upvc pipe as per site requirementMake: Astral/Finolex /Truflo/ Hil/ Prince/Supreme(ii) 1 inch elbow - 150 Nos(iii) 1 inch bend - 90 Nos(iv) 1 inch tee - 40 Nos(v) 1 inch coupler - 60 Nos(vi) 1 ½ inch tee - 45 Nos(vii) 1/2 inch upvc pipe - 490 RMMake: Astral/Finolex /Truflo/ Hil/ Prince/Supreme(viii) 1/2 inch tee - 35 Nos (ix) 1/2 inch thread tee - 400 Nos(x) 1/2 inch thread elbow - 60 Nos(xi) Spayer - 460 Nos(xii) 1/2 inch bend & tee - 35 Nos(xiii) 1/2 inch coupler - 10 Nos (xiv) UPVC Solution - 5 KG(xv) Electrical wiring - 215 RM(xvi) Aqua Machine - 15 Nos(xvii) Timer - 02 Nos(xviii) 1 HP Submersible Pump - 02 Nos |
| 14 | Supply & Fixing Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) of capacity 1000 ltrs hoisted and fixed in position, Complete all as specified & directed by Engineer-in-Charge.Make:- Sintex/Polycon / Rolex/ Vectus/ Infra |
| 15 | Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches complete all as specified as per site requirement complete of sizes of nominal dia:- Make:- Finolex / Astral/ Dutron /SFMC/ FUSION/ JAIN PLUMBING |
| 16 | 32 mm OD |
| 17 | 50 mm OD |
| 18 | Supply & Fixing CPVC Gate /ball valves as per requirement of the site of the following:- Make:- Finolex / Astral/ Dutron /SFMC/ FUSION/ JAIN PLUMBING |
| 19 | 32 mm OD |
| 20 | 50 mm OD |
| 21 | Material & Labour for submain wiring with two runs of 2.5 Sqmm single core PVC insulated but unsheathed multi stranded copper conductor FRLS 1100 volts grade cable drawn through and including PVC conduit / PVC Casing caping and one run of 2.5 Sqmm single core PVC insulated but unsheathed multistranded copper conductor 1100 volts grade cable as earth conductor in concealed/surface casing caping but shall be increased as per actual site requirement in accordance with clause No. 19.125 of SSR Part-I) ISI marked with wall thickness not less than 1.8mm including conduit accessories like bends, tees, junction boxes etc fixed concealed/recessed in wall or ceiling etc., Complete all as specified & directed by Engineer-in-Charge.Make:- Anchor/Havells/Finolex/ RPG/Nicco/ Plaza |
| 22 | Supply & Fixing MCB (DB) SPN 4 way double door 415 V made of sheet metal enclosure for MCB\"s as incomming and SPN/SP MCB as outgoing, Complete all as specified & directed by Engineer-in-Charge.Make:- Hager / Legrand/ schneider |
| 23 | Supply & Fixing MCB SPN pole 240 volt C curve 10 KA, ISI marked as per IS/IEC 60898-1 2002of 16/32 Amps capacity IP 20, Complete all as specified & directed by Engineer-in-Charge.Make:- Hager / Legrand/ schneider |
| 24 | Supply & Fixing MCB SP 240 volt C curve 10 KA, ISI marked as per IS/IEC 60898-1 2002 of 6/32Amps capacity IP 20, Complete all as specified & directed by Engineer-in-Charge.Make:- Hager / Legrand/ schneider |
| 25 | Supply and fixing in replacement LED flood light fitting of 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP-66 protection luminaire with aluminium die-cast housing, toughened glass and unique lens system, for enhanced illumination. and mounting accessories, Complete all as specified & directed by Engineer-in-Charge.Make:- Wipro/ philips/ Crompton |
| 26 | Supply, installed, testing and commissioning submersible pump set, electric drivern 3 phase, 415 V (+10 or -10), confirming IP 68, CI Body, CI/Bronze impeller of head range 16 m, discharge 1000-600 LPM capacity of size 50mm including installation, starter, coupling with discharge pipe, etc.Complete all as specified & directed by Engineer-in-Charge. Make :- Kirloskar/ Crompton/ KSB/ Mather & Platt/ Jyoti/ Grandfos pumps india Pvt Ltd / CRI pumps/ Suguna pumps |
| 27 | Material & Labour weather proof flexible three core flat cables copper conductor insulated with PVC sheathed for submersible pump motor with voltage grade upto 1100, 6.0 Sqmm including proper lugs and fittings, Complete all as specified & directed by Engineer-in-Charge.Make:- Finolex / Anchor/ Havells/ RPG |
| 28 | Material & Labour for plain cement concrete (PCC) in foundation using 1:4:8 mix type D-2 using 40mm graded aggregate for foundation/ support, Complete all as specified & directed by Engineer-in-Charge. |
| 29 | Material & Labour for PCC Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concreteusing 1:2:4 type B-2, 20mm graded aggregate for foundation, including necessary formwork, Complete all as specified & directed by Engineer-in-Charge. |
| 30 | Material & Labour for fabrication and installation Framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165, Complete all as specified & directed by Engineer-in-Charge. |
| 31 | Earthing complete with galvanised steel earth plate electrode 60cm × 60cm × 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion, Complete all as specified & directed by Engineer-in-Charge. |
| 32 | Supply and laying double wall corrugated (DWC) high density polythene pipes having corrugation on the outer wall and plain surface on the inner wall confirming to ISI 14930 ( Part I and II) for protection of underground calbes of size 63 mm outer diawith all fittings. laid in trenches / road/ nallah or fixed along wall. poles or laid under floor (including cutting floor/Road and making good to match with existing adjoining surface etc for cable protection, Complete all as specified & directed by Engineer-in-Charge.NOTE:- Excavation and earth work shall be measured and paid separately Make:- Rex/Poly/Gemini |
| 33 | Supply, installation & testing Solar Water heating system of capacity 200 LPD consisting of flat plate collector box fabricated from aluminium extruded sections by means of gas welding or brazing leak proof fully insulated with glass wool (48Kg/M3) with supporting structure duly painted with synthetic enamel black paint over a coat of zinc chromate red oxide primer provided with absorber made from copper sheet & copper tubes with protective coating complete with header grommet, storage tank made from stainless steel sheet of minimum 20 SWG thickness with puff insulation of minimum 50 mm girth outer including brass socket & nipple fully insulated with glass wool with cold & hot water piping, gun metal valves, coil type stainless steel heat exchanger complete conforming to IS-12933 & 12976 with necessary wiring and electric backup arrangement fixed on roof, connected to cold water tankcapable to supply hot water at 60° C, including taking down old unserviceable solar water heater, Complete all as specified & directed by Engineer-in-Charge. Make :- SINTEX/BHEL/TATA /BP SOLAR INDIA LIMITED/Honey well / Bosch / Racold |
| 34 | Material & Labour for fabrication and installation Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165, including taking down old unserviceable framed work, Complete all as specified & directed by Engineer-in-Charge. |
| 35 | Supply and laying of CPVC pipes SDR 11 & Plain CPVC SDR 1125mm DIA fittings on walls/ceiling or laying in floors, Complete all as specified & directed by Engineer-in-Charge.Make:- Finolex / Ashirvad /Supreme / Astral/ Truflo/ Hil/ Prince/ Dutron /SFMC |
| 36 | Supply and fixing Ball brass valves, high pressure, with polythene float and flynutcomplete, screwed for iron pipe or brass ferrule and fixed, Complete all as specified & directed by Engineer-in-Charge. |
| 37 | Supply and fixing in repair Rotational moulded polyethylene water storage tanks 750 Ltrs cap (cylindrical vertical with closed top) hoisted and fixed in position, Complete all as specified & directed by Engineer-in-Charge.Make:- Sintex/Polycon / Rolex/ Vectus/ Infra |
| 38 | Supply and fixing in repair Hot water pipe duly insulated with glass wool and aluminium cladding 20mm bore, Complete all as specified & directed by Engineer-in-Charge. |
| 39 | Supply and fixing electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc., Complete all as specified & directed by Engineer-in-Charge.Make:-Crompton/Racold/Havells |
| 40 | Supply & Fixing Hot/Cold water connection pipe 450 mm length, Complete all as specified & directed by Engineer-in-Charge. |
| 41 | Supply & Fixing 16A 3 Pin Plug Top 240V, Complete all as specified & directed by Engineer-in-Charge.Make:- Anchor(Panasonic)/ Havells/legrand |