Tender For Special Repair To Roling Shutters And Certain Misc Br Works To Bldg No T 201 Of 45 Ad Regt Basantar River At Misa Camp Under Ge S Tezpur, tezpur-Assam

Military Engineer Services-MES has published Tender For Special Repair To Roling Shutters And Certain Misc Br Works To Bldg No T 201 Of 45 Ad Regt Basantar River At Misa Camp Under Ge S Tezpur. Submission Date for this Tender is 11-05-2024. Door Tenders in tezpur Assam. Bidders can get complete Tender details and download the document.




Tender Notice

43186579
Tender For Special Repair To Roling Shutters And Certain Misc Br Works To Bldg No T 201 Of 45 Ad Regt Basantar River At Misa Camp Under Ge S Tezpur
Open Tender
Indian
Assam
tezpur
11-05-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Tender For Special Repair To Roling Shutters And Certain Misc Br Works To Bldg No T 201 Of 45 Ad Regt Basantar River At Misa Camp Under Ge S Tezpur

Key Value

Document Fees
INR 500 /-
EMD
INR 49600.0 /-
Tender Value
Refer document

Attachment

FileName File Description File Size
ccd76bf7-f3b4-4da9-b198-2ddaa050e595.html Tender Notice 0 KB
Addldocus.pdf Tender Document 0 KB
BOQ_728018.xls Tender Document 0 KB
Tenderdocuments8863.pdf Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

Name of Work: SPL REPAIR TO ROLING SHUTTERS AND CERTAIN MISC B/R WORKS TO BLDG NO T-201 OF 45 AD REGT (BASANTAR RIVER) AT MISA CAMPUNDER GE (S) TEZPUR
Sl. No. Item Description
1Taking down cement plaster on brick/concrete surfaces of walls and ceiling including racking out jointing hacking for key, scrubbing down with water etc.Complete all as specified and as directed.
2Taking down chowkhats incl shutterrs (without taking off shutters from the frame) exc 1.5 sqm and n.exc 4 sqm each .Complete all as specified and as directed.
3Taking down chowkhats incl shutterrsn exc 1.5 sqm ,complete all as specified and directed by engr in charge
4Dismantling water tanks of capacity exc 500litres & not exc 1000 litres and removing to store.Complete all as specified and as directed.
5Demolition of Reinforced Cement Concreteof any description specifically provided for.Complete all as specified and as directed.
6Dismantling of rolling shutter exc 18 sqm but not exc 22 sqm.Complete all as specified and as directed.
7Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
8Dismantling unframed timber scantlings 40 sq. cm and over in section, in any position, complete all as sfd and as directed.
9Demolition of Cement Concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed.
10Taking up or down steel tubing of size 15 mm and connections, including cleaning for refixing or removal to store.Complete all as specified and as directed.
11Taking up or down steel tubing of size 20 mm and connections, including cleaning for refixing or removal to store.Complete all as specified and as directed.
12Dismantling of AC sheet corrugated / Semi corrugated sheets in wall cladding or in roof covering as in desired colour, size and patterncomplete all as specified and directed by engr- in- charge.
13S&F 1000 Ltrs capacity rotational moulded polythene water storage tank (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and as directed.
14S & F20 mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete as specified and directed.
15M&L for R C C1:1.5:3(20mm gradded agg) as in roof slab supported on wall, beam , landing ,deck slab etc.
16Use and waste Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and as directed.
17S&F 10mm dia and over TMT bars as in reinforcement,cut to length bent to shape etc as required incl binding with MS wire annealed not less than 0.90m dia.complete all as specified and as directed.
18S&F 20 mm Ball brass valves,high pressure,with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed all as specified and directed
19S&F 15mm bore medium grade galvanished tube with all fitting & fixed complete to walls or ceiling & laid in floors complete all as specified and as directed.
20S&F 20mm bore medium grade galvanished tube with all fitting & fixed complete to walls or ceiling & laid in floors complete all as specified and as directed.
21S & F 125 mm x 63 mm double rebate factory made 100 % solid wood polymer composite (WPC) lead free , termite proof , water proof , fire redardent door frame complete all as specified and directed by engr in charge .(Note - minimum density 750 Kg /Cum )
22S & F 30mm thick moulded factory made 100 % solid wood polymer composite (WPC) lead free termite proof , water proof , fire retardentand door shutter with prelaminated sheet in desired colourcomplete all as specified and as directed.(Note - minimum density 600 Kg /Cum )
23S/F 35 mm thick PVC mosquto proof door shutter consisting of frame made out ofM. S. tube of gauge thickness and size of 20 mm x 20 mm lipped with 5 mm Plain pvc sheet with stainless steel net with prelaminated sheet in desired colour complete all as specified and directed by engr in charge.(Note - minimum density 600 Kg /Cum )
24M&L 15 mm thick rendering in cm (1:6) on other than fair faces of brick work finished even & smooth without using extra cement.
25M&L 15mm thick rendering in cm (1:4) on fair faces of brick work with using WPC @ 2% finished even & faircomplete all as specified and as directed.
26M&Lapplying two coats of acrylic emulsion distemper over a coat primer over a coat of 1 mm thick alayer of wall care putty by smart painting method on walls complete all as specified and as directed.
27M&L two coats of acrylic emulsion distemper over a coat of primer over a coat of 1 mm thick layer of wall care putty by smart painting method including preparation of old surfaces by complete removal of existing treatment complete all as specified and as directed.
28M&L two coats of acrylic emulsion distemper by smart painting method including preparation of old surfaces by complete removal of existing treatment complete all as specified and as directed.
29M & L for two coats of exterior emulsion antifungus paint over a coat of primer over a coat of 1 mm thick wall care putty by smart painting method to wall including complete including preparation of surface as specified and directed
30M & L for two coats of exterior emulsion antifungus paint over a coat of primer over a coat of 1 mm thick wall care putty by smart painting method to wall including complete including preparation after complete removal of existing treatment as specified and directed
31Supply only integral water proofing compound
32S&Fceramic Vitrified digital tiles 10-12 mm thick (Square/rectangular) of size1200mmx1200 mm, in floors etc, set and jointed in neat cement slurry and pointed in white or Coloured cement to match icluding 15mm thick in Cement Mortar 1:6 screed bed. complete all as specified and as directed.
33S&F ceramic Vitrified digital tiles10 to 12 mm thick (Square/rectangular) of size1200mmx1200 mm, in vertical surface etc, set and jointed in neat cement slurry and pointed in white or Coloured cement to match , including necessary cutting of tiles icluding 10mm thick in Cement Mortar 1:4 screed bed complete all as specified and directed .
34M & L for Granite 18-20 mm thick (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including bull nosing complete all as specified and directed
35S&F 200 mm long aluminium handle, cast type, anodised
36S/F 150mm long aluminum anodized barred tower bolts of extruded section.
37S/F 100mm size stainless steel butt hinges, medium weight, cold rolled.
38S&F 200 mm aluminium anodisedbarrel tower bolt, of extruded sectionand fixed in position
39S/FBrass Mortice lock of four levers, vertical type, size 65 mm as in desired designcomplete all as sfd and as directed by engr in charge
40S&F Floor door stopper of aluminium alloy bodyand tongue, anodised,with hard drawn steel spring,fixed in repairs in floor complete all as specified and as directed.
41M&L for Anodised aluminium snap grid (605 x 605mm) frame work for false ceiling all as specified directed
42S&F 4mm thick Non asbestos fibre cement building boards fixed on Aluminium framework complete all as directed.
43S & F in repair 300mm, ordinary rat tail rod pattern door springs including roller and roller plate complete
44S & F in repairs fancy curtain rails, Harrison rails, stainless steel,chromium plated with fixing brackets, stops, rollers, clampsetc.
45S&F in repair 15mm bore fancy type chromium platedbib taps with crutch or butterfly handle screwed down for iron pipes.
46Demolition of reed lathing plaster complete all as specified and directed.
47M & L Brick work built in CM 1:6 with sub class "B"old sizebricks straight or curved on plan exceeding 6 m mean radius complete all as specified and as directed..
48M&L brick work using sub class ‘B’ bricks (old size) straight or curved on plan to any radius in half brick work built in CM 1:4 complete all as specified.
49M&L for preparation old surfacesof CGI Sheet roofing and applyingtwo coat ofroofpaint of any shade over a coat red oxide primercomplete all as specified and as directed
50S&F in repair Door closer hydraulically regulated, designation No. 2, universal type, suitablefor door shutters of 701 to 850 mm in width and of weight between 36 to 60 kg and fixed, complete all as specified and as directed.
51M&L for for sand cushioning layer 40 mm thick over sub base for fixing of interlocking tilesspread levelled to reqd level complete all as specified and directed.
52S & F Machine pressed precast concrete interlocking paver block gloosy fineshed laid over sand cushioning layer of 40 mm thick of any shape and design complete all as specified and directed. size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade. NOTE - ( Sand cushioning layer will be measured and paid seperately )
53S & F powder coated Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified
54S & F powder coated Anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specifiedcomplete all as specified
55S/F 5.50mm thick mirror finished ordinary quality sheet glass in squares exc 0.5 sqm in each pane fixed in aluminium frame.
56S & FPowder coated aluminium grill of design DG-104 pattern made out of 10 mm dia rod fixed withand including stranded aluminium frame of F section of size 23.40x 15.3 x 1.4 mm thick all as per manufacture instructions complete all asspecified and directed
57M & L Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified as specified and directed
58M & L Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall/eaves board, fixed with selftapping screws as specified and directed
59M & L for 2nd class hard wood in scantling wrought finished as in framed work all as specified and directed.
60M & L for Preparing old/ new surfaces of wood and wood based materials, new or old, of any description and girth, not otherwise described and treated with Cerosete oil , complete all as specified and directed by engr in charge .
61M&L for preparation oldpaintedsurfacesof woodsurfaces over 10 cm width or girthand applyingone coat ofsynthetic enamel paint over one coat of primer complete all as specified and as directed
62M&L for preparation new surfacesof steeland ironsurfaces over 10 cm width or girthand applyingtwo coat ofsynthetic enamel paint over a coat of red oxide primer complete all as specified and as directed
63S & F of Fe-410 Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc.
64S&F Mild steelFramed work such as door or gates of angle or other section, grills, gratings, etc, with ends of bars shouldered and/or riveted ,or forged into spikes, framed guard bars; barred iron doors, ladders; framed balusters; walk ways,railings, and similar work Fe 410 -W (Gde- E- 250) Quality "A"
65M&L for dismantling various components of rolling shutter for cleaning dust , replacement of old unserviceable parts including necessary welding , greasing and re assembly in original position and finally re fixing in its original of existing inluding making good to existing surface . (Note : Parts to be replaced shall be paid and measured seprately supply only )
66Supply only spigot pipe of suitable for rolling shutter of size 4.90 Rm x 4.10 Rm
67Supply only coil spring suitable for rolling shutter of size 4.90 Rm x 4.10 Rm
68Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete,including fixture and fittings such as switches,ceiling roses,pendants,regulators,sockets,light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors etc.Complete all as specified and as directed
69Material and labour point wiring for one light/fan/exhaust fan point controlled by one, one wayswitch using1.5 sqmm nominal cross sectional areamultistrandedcopper conductor ,PVC insulated unsheathedFRLSH cables in and including 20 mm dia or higher size PVC concealed conduits and fittings of medium grade, including metal flush box suitable for modular cover plate with frame of suitable size 1 M to 8 M and 1.5 sqmm nominal cross sectioanl area multistranded copper conductor FRLSHPVC insulated unsheathed earth wire and connecting to earth dolly andbrass screws, washers etc. complete all as specified and directed. (Rate deemed to be inclusive of cutting chases and making good disturbed surface).Complete all as specified and as directed
70All as per item No.69 above but One 3 pin 5 Amps socket out let points on independent board
71All as per item No.69 above but5 Amp socket on same boardwith other switches.
72M & L for point wiring for socket out let on 16 Amps independent Boards controlled by one, one wayswitch using 2.5 sqmm nominal cross sectional areamultistrandedcopper conductor, PVC insulated unsheathed FRLSH cables in and including 20 mm dia or higher size PVC concealed conduits and fittings, including metal flush box suitable for modular cover plate with frame of suitable size of 3M and 2.5 sqmm nominal cross sectioanl area multistranded copper conductor FRLSHPVC insulated unsheathed earth wire and connecting to earth dolly andbrass screws, washers etc. complete all as specified and directed. (Rate deemed to be inclusive of cutting chases and making good disturbed surface).
73Supply and fix Modular switch one way 6 Amp.
74Supply and fix modular socket outlet 2 in 1, 3 pin 10 A.
75Supply and fix modular socket outlet 2 in 1,3 pin16 Amps
76Supply and fix Modular switch one way 16 Amp.
77Material and labour for ceiling rose polycarbonate isolated body 3 ways terminals.
78Supply and fix modular type electronic fan regulator.
79Supply & fixing in repair lamp holder, PVC/polycarbonate type with back plate straight or angular suitable for batten fittings complete all as specified.
80Supply and fixing in repair modular white cover plate with frame 3 modules complete all as specified and as directed.
81Supply and fixing in repair modular white cover plate with frame 6 modules complete all as specified and as directed.
82Supply and fixing in repair modular white cover plate with frame 8 modules complete all as specified and as directed.
83Supply and fixingin repair modular metal flush box 3 modules complete all as specified and as directed.
84Supply and fixingin repair modular metal flush box 6 modules complete all as specified and as directed.
85Supply and fixingin repair modular metal flush box 8 modules complete all as specified and as directed.
86Supplying and fixing in repair two single core, 4 sqmm nominal cross sectional areamultistrandedcopper conductor FRLSH cable, PVC insulated unsheathed 1100 Volts gradedrawing in and including suitable size PVC conduit (ISI marked),concealed, including4 sqmm nominal cross sectional areamultistrandedcopper conductor FRLSH cable, PVC insulated unsheathed 1100 Volts grade earthwirecomplete all as specified. (Rate deemed to be inclusive of cutting chases and making good disturbed surface).
87Supply and fixed in repair 18 W LED light fitting wall mounted batten 4"ft ,minimumm lumen output 100 lumen/Wat, extruded polycarbonate, enivromental friendly, heat sink provided for efficent heat dissipation and integrated electronic driver for 18 watt,6500K including necessary connection complete all as specified and directed.
88Supply and fixed in repair security light fittings 30 watts, minimumm lumen output 100 lumen/Watt, made up of pressure dia cast housing with prismatic polycarbornate diffuser and individual LED with secondary optic and IP65 including necessary connection complete including 25mm dia light grade GI bracket with nut bolt and clamp complete with all accessories including connected with twin core twisted flexible copper conductor of suitable size complete all as directed.
89Supply and fixed in repair recessed mounted 2" x 2 " LED luminaire 36 watts for grid ceiling minimumm lumen output 100 lumen/Watt, pre-treated CRCA frame powder coated with diffused Profied including necessary connection complete all as specified and directed. MAKE:CG/Bajaj/ Philips & equivalents.
90Supply & fix in replacement of LED bulb 15 watt 6500 k complete all as specified and as directed.
91Supply and fixed in repairs epoxy powder coated sheet metal enclosure for DBs, double door (when MCBs to be used), Single pole and neutral 240 V, 8 ways with mounting fitted with bus bar, DIN channel , neutral link and incoming contact complete all as directed.
92Supply and fixed in repairsMCB SP,6 to 32 Amps, "C" series 10kA, 240 Volts and to be housed in DBs including necessry connection complete all as specified and directed.
93Supply and fixed in repairs MCB SPN 6-32 Amps,"C" series 10kA, 240 Volts and to be housed in DBscomplete including necessry connectionall as specified and directed.
94Taking down of AC ceiling fan of any sweep & any height and opening the fan and oiling, greasing andreplacementofunserviceable accessories and servicing, complete overhauling and re-assembling and testing complete for efficient functioning and hanging it back in position including provn of 0.5 Sqmm copper flexible twin twisted cable (length not exceeding 0.5 metre) from ceiling rose to fan as directed by the Engr-in-Charge.
95S & F ventilating exhaust fan300 mm sweep 230 volt AC complete with louver and all accessories including cutting hole of suitable size, making good surface by doing plaster and applying two coat of distemper complete with fixing arrangement to wall connected with twin core twisted flexible copper conductor (23/.0076) of suitable size all as directed.
96Material and labour for earthing complete with galvanised mild steel earth plate electrode 600x600x6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI wire 4 mm dia as earth strip electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth strip encased inand including 40 mm dia GI "lightgrade" pipe from upper end of earth plate upto equipments,20 dia bore GI pipe "light grade" as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe andPCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS round bars 6mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as describedin electric plate of SSR Part I completeall as specified and directed and testing on completion.
97Supply, laying / fixing / connecting, testing and commissioning of 10 Sqmm 2 core LT under ground cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured,electric cable (heavy duty) with multistranded aluminium conductor,1100 Volts grade in trenches/on wall/poles laid in ducts/inside protection pipe of the following cross sectional area including cable glands,lugs and suitable size of MS saddle clips (where ever cable laid in ceilings / walls without cable duct) all as directed by the Engr-in-Charge.Note 1:-The contract sum shall be arrived at after deducting amount of schedule of credit from the total quoted amount. Note 2-Contractor"s supervisor and main worker would wear shirt/T-shirt of colour sky blue/brown/yellow preferable embossed with contractor"s firm name while carrying out any activities in defence area for better check of security purpose.Note 3:-The tenderer (all eligible contractors) shall ascertain the taxes & levies as on date. The subject tender caters all the taxes & levies as on date including the latest notification of GST issued as on date ( issued by Central Board of Indirect Taxes and Customs)
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail