Military Engineer Services-MES has published Tender For Repair /Maintenance Of Water Supply Pumping/Distribution Network At Various Locations Under The Aor Of Age E/M Under Ge Khumbathang.. Submission Date for this Tender is 07-05-2024. Water Supply Project Tenders in Khumbathang Jammu And Kashmir. Bidders can get complete Tender details and download the document.
FileName | File Description | File Size |
89a07372-ada7-45b5-8693-d5e6e45d6d8b.html | Tender Notice | 0 KB |
BOQ_728008.xls | Tender Document | 0 KB |
Tender40.pdf | Tender Document | 0 KB |
Tendernotice_1.pdf | Tender Document | 0 KB |
Sl. No. | Item Description |
1 | M&L in replacement for tracer/antifreezing cable required to keep the pipe warm to avoid freezing,of GI and DIpipe complete all as specified and directed by Engr-in-Charge. |
2 | Supply and fixing in replacement of damaged nitrile insulation 19 mm thick over PPR/GI pipe of 20 mm bore size complete all as specified and directed by Engr-in-Charge. |
3 | Supply and fixing in replacement of damaged nitrile insulation 19 mm thick over PPR/GI pipe of 32/40 mm bore size complete all as specified and directed by Engr-in-Charge. |
4 | Supply and fixing in replacement of damaged nitrile insulation 19 mm thick over PPR/GI pipe of 50 mm bore size complete all as specified and directed by Engr-in-Charge. |
5 | Supply and fixing in repair 3 layer PPR polypropylene random copolymer pipes SDR 7.4 (PN16) & SDR 11 UV of 25 mm bore stablished and antimicrobial welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings to be laid in trenches/wall/floor complete all as specified and directed by Engr-in-Charge. Note:- all connected fittings like elbow, tee, reducer coupler will be count in RM |
6 | All as per item No 5.00 above but size of pipe 32 mm bore complete all as specified and directed by Engr-in-Charge. |
7 | All as per item No 5.00 above but size of pipe 40 mm bore complete all as specified and directed by Engr-in-Charge. |
8 | All as per item No 5.00 above but size of pipe 50 mm bore complete all as specified and directed by Engr-in-Charge. |
9 | Supply and fixing in repair 3 layer PPR Gate valve 32 mm complete all as specified and directed by Engr-in-Charge. |
10 | Supply and fixing in repair 3 layer PPR Gate valve 20 mm complete all as specified and directed by Engr-in-Charge. |
11 | Supply and fixing in repair 3 layer PPR Gate valve 25 mm complete all as specified and directed by Engr-in-Charge. |
12 | Supply and fixing in repair 3 layer PPR Gate valve 40 mm complete all as specified and directed by Engr-in-Charge. |
13 | Supply and fixing in repair 3 layer PPR Gate valve 50 mm complete all as specified and directed by Engr-in-Charge. |
14 | Making connection of PP-R distribution branch with PP-R main of size 16 to 40 mm by providing and fixing tee including cutting and making fusion jointetc. complete all as specified and directed by Engr-in-Charge. |
15 | Making connection of PP-R distribution branch with PP-R main of size 50 to 75 mm by providing and fixing tee including cutting and making fusion jointetc. complete all as specified and directed by Engr-in-Charge. |
16 | Excavation in trenches exceeding 1.5m wide and not exceeding 1.5m in depth and getting out in hard and rock soil complete all as specified and directed by Engr-in-Charge. |
17 | Returning, filling including spreading leveling watering and well ramming in layers not exceeding 25 mm in any type of soil complete all as specified and directed by Engr-in-Charge. |
18 | Removing surplus excavated material from site not exceeding 50 mtrs from starting point and depositing where directed at level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engr-in-Charge. |
19 | Supply and fixing in reapair GI tubing galvanized medium grade laid in trenches/walls including all necessary fittings clamps etc complete and connecting to existing system size of pipe 25 mm dia bore complete all as specified and directed by Engr-in-Charge. |
20 | All as per item No 19.00 above but size of pipe 40 mm bore complete all as specified and directed by Engr-in-Charge. |
21 | All as per item No 19.00 above but size of pipe 50 mm bore complete all as specified and directed by Engr-in-Charge. |
22 | Supply and fixing in repair gun metal gate valves with iron wheel head screwed both ends for GI pipe of the size 25 mm diacomplete all as specified and directed by Engr-in-Charge. |
23 | All as per item No 22.00 above but size of pipe 40 mm bore complete all as specified and directed by Engr-in-Charge. |
24 | All as per item No 22.00 above but size of pipe 50 mm bore complete all as specified and directed by Engr-in-Charge. |
25 | Supply and fixingin repair sluice valve of size 100 mm bore ISI marked, flanged ends drilled pressure rating PN-1.6 conforming to IS 14846-2000 having stainless steel spindle with cast iron operational wheel at top complete all as specified and directed by Engr-in-Charge. |
26 | Supply and fixing in repair 100 mm bore NRV for CI/DI pipe line complete all as specified and directed by Engr-in-Charge. |
27 | Supply and fixing in repair automatic star delta starter 415 volts 3 phase suitable for 7.5 HP motor complete all as specified and directed by Engr-in-Charge. |
28 | Supply and fixing in repair automatic star delta starter 415 volts 3 phase suitable for 20 HP motorcomplete all as specified and directed by Engr-in-Charge. |
29 | Deduct Credit for Demolished/Dismantled material Rs (-) 19,550.00 (Minus) as listed in Schedule "A" Sec-II (Credit Schedule) Note :Tenderers will not quote against this item being a tentative amount, to be considered to arrive at the "Contract Sum". |