Tender For Rewiring Electrical Installation Ground Floor Of Main Block And Campus Lighting Around Main Block Sree Krishna College Guruvayur Devaswom
Tender Value
Ref. Documents
Estimated cost
Bid Submission
25 Apr 2024
0 days left
EMD
50000
Bank guarantee accepted
Document Fee
2760
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
guruvayur → Kerala
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Rewiring Electrical Installation Ground Floor Of Main Block And Campus Lighting Around Main Block Sree Krishna College Guruvayur Devaswom
BOQ
| Sl. No. | Item Description |
| 1 | Rewiring |
| 2 | 90.2.1.8Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm withspecials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988,fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, includingproviding switch board main and continuous earthing with No.14 SWG bare copper,required quantity ofcopper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular typemetal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SPswitches and making good the surface of wall, colour washing etc. complete. All the terminations in theswitch boards and DB\"s shall be tinned and the wires shall be drawn and fixed along the periphery of thebox using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single Controllight point with 6A, plate ceiling rose - Medium Point |
| 3 | 90.2.1.10Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm withspecials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988,fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, includingproviding switch board main and continuous earthing with No.14 SWG bare copper,required quantity ofcopper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular typemetal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SPswitches and making good the surface of wall, colour washing etc. complete. All the terminations in theswitch boards and DB\"s shall be tinned and the wires shall be drawn and fixed along the periphery of thebox using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single controllight point without ceiling rose - Medium point |
| 4 | 90.2.1.11Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm withspecials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988,fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, includingproviding switch board main and continuous earthing with No.14 SWG bare copper,required quantity ofcopper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular typemetal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SPswitches and making good the surface of wall, colour washing etc. complete. All the terminations in theswitch boards and DB\"s shall be tinned and the wires shall be drawn and fixed along the periphery of thebox using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single controlceiling fan point with 6 A, 3 plate ceiling rose & with socket size stepped electronic regulator - MediumPoint. |
| 5 | 90.2.1.12Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm withspecials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988,fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, includingproviding switch board main and continuous earthing with No.14 SWG bare copper,required quantity ofcopper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular typemetal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SPswitches and making good the surface of wall, colour washing etc. complete. All the terminations in theswitch boards and DB\"s shall be tinned and the wires shall be drawn and fixed along the periphery of thebox using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Call bell pointwith piano type 6 A bell push at one end and 6 A, 3 plate ceiling rose at other end - Medium point |
| 6 | 90.2.1.13Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm withspecials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988,fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, includingproviding switch board main and continuous earthing with No.14 SWG bare copper,required quantity ofcopper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular typemetal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SPswitches and making good the surface of wall, colour washing etc. complete. All the terminations in theswitch boards and DB\"s shall be tinned and the wires shall be drawn and fixed along the periphery of thebox using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Combinedplug point with 6 A, 5 pin plug socket controlled by 6 A switch in the same switch board as that of lightpoints. |
| 7 | 90.2.1.14Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm withspecials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988,fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, includingproviding switch board main and continuous earthing with No.14 SWG bare copper,required quantity ofcopper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular typemetal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SPswitches and making good the surface of wall, colour washing etc. complete. All the terminations in theswitch boards and DB\"s shall be tinned and the wires shall be drawn and fixed along the periphery of thebox using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).IndependentPlug - Medium Point |
| 8 | 90.3.20.3Supply & installation of light fittings on TW round block Supply, conveyance installation testing andcommissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with allaccessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit thefitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wireconforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box typefixture |
| 9 | 90.3.21.3Supply & installation of light fittings on \"C/U\" shaped flat iron bracket Supply, conveyance, installation,testing and commissioning the light fittings of following types made from 0.5mm CRCA sheet completewith all accessories and lamps etc. directly on wall using 2 nos. \"C/U\" brackets made from 20 x 3 mm MSflat, painting the flat iron bracket and giving connections with required length of 16/0.20mm 3 core copperconductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc.as required.1200 mm 1X20W LED Lamp with box type fixture |
| 10 | 90.3.24.3Supply & installation of light fittings suspended on ball & socket arrangement with 19 mm downrod Supply, conveyance, installation, testing and commissioning the light fittings of following typesmade of .5mm thick CRCA sheet accessories and lamps etc. including supplying and fixing ball andsocket arrangements on PVC round block, suspension down rod of 19mm dia MS conduit up to 2x30cmlength including painting and wiring the down rod with 16/0.20mm 3 core round copper conductor flexwire conforming to relevant ISS or extending the original wiring and giving connections etc. arequired.1200 mm 1X20W LED Lamp with box type fixture |
| 11 | od172071/2023_2024Supply, installation , testing and commissioning of 300/305 mm heavy duty exhaust fan 900 rpm in metalbody working on 230V single phase A/C supply in the existing opening including making the holes to suitthe size of the above fan, fixing necessary bolt and nuts making good the damages etc. as requiredincluding giving connections |
| 12 | od172072/2023_2024Supply, installation , testing and commissioning of 150 mm light duty exhaust fan in plastic body with selfopening louvers working on 230V single phase A/C supply in the existing opening including making theholes to suit the size of the above fan, fixing necessary bolt and nuts making good the damages etc. asrequired including giving connections |
| 13 | od172073/2023_2024Supply installation testing and commissioning of LED Flood light fitting 2X60W with efficacy upto150lm/w,Surge protection 10KV,IP68 for LED chamber and IP67 for driver compartment,5 years warrantyLED Chip make Cree/Lumilled/Nichia Power factor 0.9 and giving connection.LM 79&80 certificates to beproduced.(Aston prime K-lite Id 4201/equivalent) |
| 14 | od172074/2023_2024Supply, conveyance, installation, testing and cmmissioning of ceiling fan of all sizes using standardaccessories including wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100Vgrade 3 core round copper conductor flex wire or with extended original wiring etc. as required.1200mmsweep 5 star rated BLDC ceiling fan with service value greater than or equal to 6 complete with 260mmdown rod , canopies, shackeles and blades working on 230V/240V single phase A/C. |
| 15 | 90.4.1Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required. |
| 16 | 90.4.2Supply and installation of suitable size MS belt type fan clamp fabricated from flat iron 40 x 6 mm,150mm long x 2 Nos with M.S. rod bent to shape, neatly painted with 2 coats of enamel paint over a coatof red oxide primer as per IS 732 as required. |
| 17 | 90.4.8Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep includingplastering colour washing etc. as required. |
| 18 | 90.5.1.3Supply and fixing the following types of superior quality 250V A.C call bell on existing M.S. box and givingconnections with required length of 3 core, 16 / 0.20mm 650/1100V grade PVC insulated and PVCsheathed round copper conductor flex wire conforming to relevant ISS or with the extended originalwiring, earthing the MS box and making good the surface as required.Ding dong bell |
| 19 | 90.5.1.8Supply and fixing the following types of superior quality 250V A.C call bell on existing M.S. box and givingconnections with required length of 3 core, 16 / 0.20mm 650/1100V grade PVC insulated and PVCsheathed round copper conductor flex wire conforming to relevant ISS or with the extended originalwiring, earthing the MS box and making good the surface as required.Gong bell 150mm-without MS box |
| 20 | 90.6.10.1Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recessincluding cutting the wall and making good the same in case of recessed conduit as required20 mm |
| 21 | 90.6.10.2Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recessincluding cutting the wall and making good the same in case of recessed conduit as required25 mm |
| 22 | 90.9.1.1Supply and fixing 50 x 50 mm PVC Cable Management System with base and lid along with the followingaccessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall andmaking good the damages in case of recessed installation as required.50x50mm Cable ManagementSystem with base and lid |
| 23 | 90.9.1.2Supply and fixing 50 x 50 mm PVC Cable Management System with base and lid along with the followingaccessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall andmaking good the damages in case of recessed installation as required.External angle 90 degree |
| 24 | 90.9.1.4Supply and fixing 50 x 50 mm PVC Cable Management System with base and lid along with the followingaccessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall andmaking good the damages in case of recessed installation as required.Internal angle 90 degree |
| 25 | 90.9.1.7Supply and fixing 50 x 50 mm PVC Cable Management System with base and lid along with the followingaccessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall andmaking good the damages in case of recessed installation as required.End cap |
| 26 | 90.9.2.1Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with thefollowing accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting thewall and making good the damages in case of recessed installation as required.100 x 50 mm CMS withbase and lid |
| 27 | 90.9.2.3Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with thefollowing accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting thewall and making good the damages in case of recessed installation as required.External angle 90 degree |
| 28 | 90.9.2.5Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with thefollowing accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting thewall and making good the damages in case of recessed installation as required.Internal angle 90 degree |
| 29 | 90.9.2.8Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with thefollowing accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting thewall and making good the damages in case of recessed installation as required.End cap |
| 30 | 1.17.2Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in theexisting surface / recessed steel/ PVC conduit as required.2 x 1.5 sq. mm |
| 31 | 1.17.4Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in theexisting surface / recessed steel/ PVC conduit as required.4 x 1.5 sq. mm |
| 32 | 1.17.6Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in theexisting surface / recessed steel/ PVC conduit as required.6 x 1.5 sq. mm |
| 33 | 1.17.8Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in theexisting surface / recessed steel/ PVC conduit as required.8 x 1.5 sq. mm |
| 34 | 1.17.11Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in theexisting surface / recessed steel/ PVC conduit as required.2 x 2.5 sq. mm |
| 35 | 1.17.13Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in theexisting surface / recessed steel/ PVC conduit as required.4 x 2.5 sq. mm |
| 36 | 1.17.15Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in theexisting surface / recessed steel/ PVC conduit as required.6 x 2.5 sq. mm |
| 37 | 1.17.20Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in theexisting surface / recessed steel/ PVC conduit as required.2 x 4 sq. mm |
| 38 | 1.17.21Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in theexisting surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm |
| 39 | 1.17.22Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in theexisting surface / recessed steel/ PVC conduit as required.4 x 4 sq. mm |
| 40 | 1.17.31Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in theexisting surface / recessed steel/ PVC conduit as required.4 x 6 sq. mm |
| 41 | 1.24.1Supplying and fixing following modular switch/ socket on the existing modular plate & switch boxincluding connections but excluding modular plate etc. as required.5/6 amps switch |
| 42 | 1.24.3Supplying and fixing following modular switch/ socket on the existing modular plate & switch boxincluding connections but excluding modular plate etc. as required.15/16 amp switch |
| 43 | 1.24.4Supplying and fixing following modular switch/ socket on the existing modular plate & switch boxincluding connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet |
| 44 | 1.24.5Supplying and fixing following modular switch/ socket on the existing modular plate & switch boxincluding connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet |
| 45 | 1.26Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modularplate as required. |
| 46 | 1.27.1Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modularswitches in recess etc as required.1 or 2 Module (75mmX75mm) |
| 47 | 1.27.2Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modularswitches in recess etc as required.3 Module (100mmX75mm) |
| 48 | 1.27.4Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modularswitches in recess etc as required.6 Module (200mmX75mm) |
| 49 | 1.27.5Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modularswitches in recess etc as required.8 Module (125mmX125mm). |
| 50 | 90.10.3.15Supply and Fixing the following modular switches & accessories in the existing front plates and givingnecessary connections as required (RoHS compliant )32A DP switch with indicator |
| 51 | 90.10.3.33Supply and Fixing the following modular switches & accessories in the existing front plates and givingnecessary connections as required (RoHS compliant )25A 3pin Shuttered socket |
| 52 | 2.3.3Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V,on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar,interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12way, Double door |
| 53 | 2.3.4Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V,on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar,interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator16way, Double door |
| 54 | 90.11.1.10Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure ofMCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall ,making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP42/43) |
| 55 | 90.11.1.11Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure ofMCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall ,making good the damages, colour washing etc. as required6 way (8+18) - three phase double cover (IP42/43) |
| 56 | 90.11.1.15Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure ofMCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall ,making good the damages, colour washing etc. as required6 way (8+18) - double cover TPN vertical DBwith provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP42/43) |
| 57 | 90.11.1.19Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure ofMCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall ,making good the damages, colour washing etc. as required6 way (8 + 18) - double cover TPN vertical DBwith provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43) |
| 58 | 2.10.1Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breakersuitable for inductive load of following poles in the existing MCB DB complete with connections, testingand commissioning etc. as required.Single pole |
| 59 | 2.10.4Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breakersuitable for inductive load of following poles in the existing MCB DB complete with connections, testingand commissioning etc. as required.Triple pole |
| 60 | 2.11Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 61 | 2.12.1Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB completewith connections, testing and commissioning etc. as required.40 amps |
| 62 | 2.13.1Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete withconnections, testing and commissioning etc. as required.40 amps |
| 63 | 2.13.2Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete withconnections, testing and commissioning etc. as required.63 amps |
| 64 | 2.14.1Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual currentcircuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete withconnections, testing and commissioning etc. as required.25 amps |
| 65 | 2.15.2Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual currentcircuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete withconnections, testing and commissioning etc. as required.40 amps |
| 66 | 2.15.3Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual currentcircuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete withconnections, testing and commissioning etc. as required.63 amps |
| 67 | 2.16Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts \"C\"curve DP MCB complete with connections, testing and commissioning etc. as required. |
| 68 | 2.18Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth,metalenclosed plug top along with 20 amps \"C\" curve, SP, MCB, in sheet steel enclosure, onsurface or inrecess, with chained metal cover for the socket out let and complete with connections, testing andcommissioning etc. as required. |
| 69 | 90.12.7.1Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium powercable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clampsnot exceeding 60cms, making good the damages , colour washing etc. as required.2 core 4 sq mm withfactory made clamp |
| 70 | 90.12.7.42Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium powercable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clampsnot exceeding 60cms, making good the damages , colour washing etc. as required.4 core 25 sq mm withfactory made clamp |
| 71 | 9.1.34Supplying and making end termination with brass compression gland and aluminium lugs for followingsize of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade asrequired.4 X 25 sq. mm (28mm) |
| 72 | od172698/2023_2024Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 2 X 4 sq. mm |
| 73 | 5.4Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, andprovidingmasonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc.with charcoal/ coke and salt as required. |
| 74 | 5.15Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 75 | 90.16.1.1Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and givingconnection as required2.00 mm copper conductor ( 14 SWG) |
| 76 | 90.16.1.2Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and givingconnection as required2.65 mm copper conductor (12 SWG) |
| 77 | 90.16.1.3Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and givingconnection as required3.15 mm copper conductor ( 10 SWG) |
| 78 | 90.16.1.4Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and givingconnection as required4.00 mm copper conductor ( 8 SWG) |
| 79 | 90.16.2.1Supply and laying of the following sizes of B class GI pipe laid 0.6 m below ground level includingexcavating trench of suitable size and refilling etc, as required.15.mm dia. G.I pipe ( medium class) |
| 80 | 90.16.5.1Supply of superior quality copper earth socket for the following size of earth conductor including crimpingetc. as required.2.00 mm (14 SWG) |
| 81 | 90.16.5.2Supply of superior quality copper earth socket for the following size of earth conductor including crimpingetc. as required.2.65 mm (12 SWG) |
| 82 | 90.16.5.3Supply of superior quality copper earth socket for the following size of earth conductor including crimpingetc. as required.3.15 mm (10 SWG) |
| 83 | 90.16.5.4Supply of superior quality copper earth socket for the following size of earth conductor including crimpingetc. as required.4.00 mm (8 SWG) |
| 84 | od172578/2023_2024Supply Installation testing and commissioning of Sub main distribution board 4 way with 3 pole MCCB asincoming and 3 pole MCCB out going conforms to IEC 61539-2 IP43 on wall/floor using Anchor bolt nutetc as required.(L&T/Equivalent) |
| 85 | od172582/2023_2024Supply and providing Cable alley box suitable for 4 way sub switch board left/right side (L&T/equivalent |
| 86 | od172637/2023_2024Supply and providing bottom cable alley box suitable for 4 way sub switch board using suitable nut boltetc as required.(L&T/equivalent) |
| 87 | od172583/2023_2024Supply and providing Corner box suitable for 4 way sub switch board (L&T/equivalent) |
| 88 | od172584/2023_2024Supply and providing metering extension box suitable for 4 way sub switch board with provision forAmmeters Volt meter selector switch and indicators etc. as required.(L&T/Equivalent) |
| 89 | od172588/2023_2024Supply and providing single phase digital Ammeter class1 and giving connection etc asrequired.(L&T/equivalent) |
| 90 | od172589/2023_2024Supply and providing 3 phase digital Volt meter 50-520V class1with selector switch and giving connectionetc as required.(L&T/equivalent) |
| 91 | od172591/2023_2024Supply and providing Danger notice board of size 250X200mm with inscriptions(Both English andMalayalam) and conventional skull and bone in Red color |
| 92 | od172592/2023_2024Supply fixing LED Indicator red Green Black Yellow color 22.5mm cut out |
| 93 | od172593/2023_2024Supply fixing LED Indicator Blue color 22.5mm cut out |
| 94 | od172594/2023_2024Supply and fixing 160/5,15VA,class 1 CT unit using suitable bracket and giving connection. |
AI Tender Summary
Tender Timeline
Apr 17, 2024
11:30 IST
Tender Published
Tender notice published.
CompletedApr 25, 2024
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedApr 29, 2024
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender