Educational and Research Institute Government Departments Closing in 0 days TDR #43183677

Provision Of Ac Facility To Walmart Space , Double Skin Fan Coil Units - Decorative Type Ceiling Suspended -Inside Conditioned Spacesitc Of Double Skin Chilled Water Fan Coil Unit. It Is Proposed To Install These Units Ceiling Suspended Inside The Condit

Issued by Government Departments · Madras, Tamil Nadu
Tender Value
Ref. Documents
Estimated cost
Bid Submission
30 Apr 2024
0 days left
EMD
12500
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Madras → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Provision Of Ac Facility To Walmart Space , Double Skin Fan Coil Units - Decorative Type Ceiling Suspended -Inside Conditioned Spacesitc Of Double Skin Chilled Water Fan Coil Unit. It Is Proposed To Install These Units Ceiling Suspended Inside The Conditioned Area Without False Ceiling. Hence, Aesthetics Of The Unit Is Of Parmount Importance. The Unit Shall Be Constructed Out Of Sandwiched Panels Minimum 43 Mm Thick Rpuf Insulation, With Thermal Break Profile.The Outer Sheet Of The Panel Shall Be 0.8Mm Thick And The Inner Sheet Shall Be 0.63Mm Thick. The Unit Shall Be Provided With Aaluminium Powdercoated Grille For Both Supply Air And Return Air. Ra Grille On The Rear Side. Sa Grille Shall Be Provided In The Front Side. ( Please Refer Enclosed Sketch ) . The Units Shall Be With Blow Through Design, Units Complete With Pre-Filters, Fan Section With Didw Forward Curved Fan Directly Coupled To A Single Phase Motor Operable In 3 Speeds, 3 Row Deep Cooling Coil& Extended Drain Tray. Coil Section Shall Be With Suitable Air Vent And Drain Points.The Coil Section And Drain Tray Sections Shall Be Provided With Sandwiched Insulation.The Unit Shall Be Sizedto Accommodate The Isolation Valves As Well As The Control Valve. The Fcu Shall Be Factory Fitted With Isolation Valves ( Ball Valve With Strainer At Inlet And Without Strainer At Outlet ) , 2 Waymotorised Valve ( On / Off Type ) Motorised Valve With Spring Return ( Valve To Close When The Power Supply Is Cut Off ) , Necessary Interconnections Etc., Price To Include For Room Thermostat Compatable For Bms Integration ( Bacnet Over Mstp ) With On / Off, Fan Speed And Temperature Control With A Digital Display & Upto 15Rmt Of Interconnecting Wiring Between Fcu And Thermostat In Gi Conduits. Price Also To Include Upto 3Rmt Of Copper Flexible Multicore Cable With Plugtop For Power. , 2.0Tr, 800 Cfm , 1.0 Tr, 400 Cfm , Sitc Of Pre Insulated Chilled Water Piping Inside Buildings Inwelded Construction With Ms Erw Pipes With Factory Made Gi Spiral Pipe Jacketed Puf Insulation Complete With All Fittings, Flanges, Pressure Testing As Per Specification. Pipes 150Mm Dia And Below Shall Be C Class As Per Is1239.200 Mm And Above Shall Be As Per Is3589 With Wall Thicness As Specified. Cost To Include Necessary Supports With Puf Saddles. , 40Mm Dia Nb - Jacket Dia Min 140Mm , 32Mm Dia Nb - Jacket Dia Min 125Mm , 25Mm Dia Nb - Jacket Dia Min 125Mm , Copper Chilled Water Pipingsitc Of Copper Soft / Hard Drawn Piping For Smaller Chilled Water Units ( Csu, Fcu, Hiwalls ) With All Fitting And Insulated With Class O Tubular Closed Cell Nitrile Rubber 25Mm Thick Insulation With Factory Made Glass Cloth Backing. Thickness Of The Copper Pipe Shall Be Minimum 22G. Price To Include Necessary Flare Nuts, Adaptors Etc., Copper Pipe Routing Shall Be As Per The Attached Tender Layouts. , 19.1Mm Dia

BOQ

Name of Work: PROVISION OF AC FACILITY TO WALMART SPACE
Sl. No. Item Description
1DOUBLE SKIN FAN COIL UNITS - DECORATIVE TYPE CEILING SUSPENDED -INSIDE CONDITIONED SPACESITC of double skin chilled water Fan Coil Unit. It is proposed to install these units ceiling suspended inside the conditioned area without false ceiling. Hence, aesthetics of the unit is of parmount importance. The unit shall be constructed out of sandwiched panels minimum 43 mm thick RPUF insulation, with thermal break profile.The outer sheet of the panel shall be 0.8mm thick and the inner sheet shall be 0.63mm thick. The unit shall be provided with aAluminium powdercoated grille for both supply air and return air. RA Grille on the rear side. SA Grille shall be provided in the front side. (please refer enclosed sketch). The units shall be with blow through design, units complete with pre-filters, fan section with DIDW forward curved fan directly coupled to a single phase motor operable in 3 speeds, 3 row deep cooling coil& extended drain tray. Coil section shall be with suitable air vent and drain points.The coil section and drain tray sections shall be provided with sandwiched insulation.The unit shall be sizedto accommodate the isolation valves as well as the control valve. The FCU shall be factory fitted with isolation valves (ball valve with strainer at inlet and without strainer at outlet), 2 WayMotorised Valve(On/Off type) motorised valve with spring return (Valve to close when the power supply is cut off), necessary interconnections etc., Price to include for Room Thermostat compatable for BMS integration (Bacnet over MSTP) with On/Off, Fan Speed and Temperature Control with a digital display & upto 15Rmt of interconnecting wiring between FCU and Thermostat in GI conduits. Price also to include upto 3Rmt of copper flexible multicore cable with plugtop for power.
22.0TR, 800 CFM
31.0 TR, 400 CFM
4SITC of Pre Insulated Chilled water piping inside buildings inwelded construction with MS ERW pipes with factory made GI spiral pipe jacketed PUF insulation complete with all fittings, flanges, pressure testing as per specification. Pipes 150mm dia and below shall be C class as per IS1239.200 mm and above shall be as per IS3589 with wall thicness as specified. Cost to include necessary supports with PUF saddles.
540mm dia NB - jacket dia min 140mm
632mm dia NB - jacket dia min 125mm
725mm dia NB - jacket dia min 125mm
8COPPER CHILLED WATER PIPINGSITC of Copper Soft / Hard drawn piping for smaller chilled water units (CSU, FCU, Hiwalls) with all fitting and insulated with class \"O\" tubular closed cell nitrile rubber 25mm thick insulation with factory made glass cloth backing. Thickness of the copper pipe shall be minimum 22G. Price to include necessary flare nuts, adaptors etc., Copper pipe routing shall be as per the attached tender layouts.
919.1mm dia

AI Tender Summary

OUR REF NO 43183677
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 30-04-2024
Authority
Authority Name Indian Institute Of Technology
Work Description Provision Of Ac Facility To Walmart Space , Double Skin Fan Coil Units - Decorative Type Ceiling Suspended -Inside Conditioned Spacesitc Of Double Skin Chilled Water Fan Coil Unit. It Is Proposed To Install These Units Ceiling Suspended Inside The Conditioned Area Without False Ceiling. Hence, Aesthetics Of The Unit Is Of Parmount Importance. The Unit Shall Be Constructed Out Of Sandwiched Panels Minimum 43 Mm Thick Rpuf Insulation, With Thermal Break Profile.The Outer Sheet Of The Panel Shall Be 0.8Mm Thick And The Inner Sheet Shall Be 0.63Mm Thick. The Unit Shall Be Provided With Aaluminium Powdercoated Grille For Both Supply Air And Return Air. Ra Grille On The Rear Side. Sa Grille Shall Be Provided In The Front Side. ( Please Refer Enclosed Sketch ) . The Units Shall Be With Blow Through Design, Units Complete With Pre-Filters, Fan Section With Didw Forward Curved Fan Directly Coupled To A Single Phase Motor Operable In 3 Speeds, 3 Row Deep Cooling Coil& Extended Drain Tray. Coil Section Shall Be With Suitable Air Vent And Drain Points.The Coil Section And Drain Tray Sections Shall Be Provided With Sandwiched Insulation.The Unit Shall Be Sizedto Accommodate The Isolation Valves As Well As The Control Valve. The Fcu Shall Be Factory Fitted With Isolation Valves ( Ball Valve With Strainer At Inlet And Without Strainer At Outlet ) , 2 Waymotorised Valve ( On / Off Type ) Motorised Valve With Spring Return ( Valve To Close When The Power Supply Is Cut Off ) , Necessary Interconnections Etc., Price To Include For Room Thermostat Compatable For Bms Integration ( Bacnet Over Mstp ) With On / Off, Fan Speed And Temperature Control With A Digital Display & Upto 15Rmt Of Interconnecting Wiring Between Fcu And Thermostat In Gi Conduits. Price Also To Include Upto 3Rmt Of Copper Flexible Multicore Cable With Plugtop For Power. , 2.0Tr, 800 Cfm , 1.0 Tr, 400 Cfm , Sitc Of Pre Insulated Chilled Water Piping Inside Buildings Inwelded Construction With Ms Erw Pipes With Factory Made Gi Spiral Pipe Jacketed Puf Insulation Complete With All Fittings, Flanges, Pressure Testing As Per Specification. Pipes 150Mm Dia And Below Shall Be C Class As Per Is1239.200 Mm And Above Shall Be As Per Is3589 With Wall Thicness As Specified. Cost To Include Necessary Supports With Puf Saddles. , 40Mm Dia Nb - Jacket Dia Min 140Mm , 32Mm Dia Nb - Jacket Dia Min 125Mm , 25Mm Dia Nb - Jacket Dia Min 125Mm , Copper Chilled Water Pipingsitc Of Copper Soft / Hard Drawn Piping For Smaller Chilled Water Units ( Csu, Fcu, Hiwalls ) With All Fitting And Insulated With Class O Tubular Closed Cell Nitrile Rubber 25Mm Thick Insulation With Factory Made Glass Cloth Backing. Thickness Of The Copper Pipe Shall Be Minimum 22G. Price To Include Necessary Flare Nuts, Adaptors Etc., Copper Pipe Routing Shall Be As Per The Attached Tender Layouts. , 19.1Mm Dia
Basic Detail
Tender No GEICSR/RAGH/004/2024/ACWALL
Bidding Type Tender
Location
City Madras
State Tamil Nadu
Key Dates
Publish Date 17 Apr 2024
Submission Date 30 Apr 2024
Open Date 01 May 2024
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 12500
Exemption Not Available
Document List
9261433d-149f-4fad-9bc4-cd6143a83c4f.html
BOQ_211957.xls
tenderdocu.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Apr 17, 2024
11:30 IST

Tender Published

Tender notice published.

Completed
Apr 30, 2024
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
May 01, 2024

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

9261433d-149f-4fad-9bc4-cd6143a83c4f.html

xls

BOQ_211957.xls

pdf

tenderdocu.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders