Tender For Increasing Capacity Of 5 To 10 Mva Substation Badesara (Aligarh) Under Business Plan 2024-25 (Semi Turn Key Basis)., aligarh-Uttar Pradesh

Dakshinanchal Vidyut Vitran Nigam Limited-DVVNL has published Tender For Increasing Capacity Of 5 To 10 Mva Substation Badesara (Aligarh) Under Business Plan 2024-25 (Semi Turn Key Basis).. Submission Date for this Tender is 03-05-2024. Substation Tenders in aligarh Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

43182025
Corrigendum : Tender For Increasing Capacity Of 5 To 10 Mva Substation Badesara (Aligarh) Under Business Plan 2024-25 (Semi Turn Key Basis).
Open Tender
Indian
Uttar Pradesh
aligarh
03-05-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Tender For Increasing Capacity Of 5 To 10 Mva Substation Badesara ( Aligarh ) Under Business Plan 2024-25 ( Semi Turn Key Basis ) .

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 24-Apr-2024 Date Extended_16 Date 29-04-2024
2 29-Apr-2024 DATE EXTENSION Date 03-05-2024

Key Value

Document Fees
INR 1180 /-
EMD
INR 8000.0 /-
Tender Value
Refer document

Attachment

FileName File Description File Size
84424eb6-3bcb-4785-a431-90869918d30f.html Tender Notice 0 KB
BOQ_1593390.xls Tender Document 0 KB
TenderDocuments16.rar Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

Name of Work:INCRESING CAPACITY OF 5 TO 10 MVA SUBSTATION BADESARA (ALIGARH) UNDER BUSINESS PLAN 2024-25 (SEMI TURN KEY BASIS).
Sl. No. Item Description
1Safe Carriage of followingstoreitemswithloading&unloadingat both ends respectively. (under jurisdiction of DVVNL) to praposed site
2Transformer
310 MVA
433 KV Single Transformer Control Panel.
533 KV VCB 800A, 750 MVA
633 KV CT, 200/100/1-1-1A
733 KV Post Insulator.
833 KV Lightening Arrestors
9Cables
1011 K.V. XLPE AL 3x300 Sq. mm.
11Supply Providing of follwoing materials (Decentralized materials) by contractor with all Associatas accessories like all Type Clamps, Nut& Bolts etc.
12Plinth & foundation of VCB
13Laying of 11 KV CableIncluding cost of sand & bricks
14(i) 3x300 Sq. mm Indoor
15(ii) 3x300 Sq. mm Outdoor
16Making of 11KV cable boxes mounted with switchgears and transformers.
1724 Volt battery and battery charger with cabinet.
18Control Cable
19(i) 4x2.5 Sq. mm.Cu. xlpe
20(ii) 2x2.5 Sq. mm.Cu. Xlpe
21Power T/F earthing (water level)
22(i) Neutral
23(ii)Body
24Painting of Substation Structure
25Erection of following Material & Miscellaneous Electrical Works. (As Per RESPO Norms) :-
26Plinth for 33 KV V.C.B.
27Construction of plinth for the structure of 33 KV VCB & C.T.’s as per details for . (All required materials provided / Supply by the contractor own his cost) :- Excavation of earth of size 2x(2.0x2.0x1.0)m pits for construction of plinth.
28Brick Ballast ratio (1:4:8) (cement, sand & brick ballast) for foundation work 2x(2.0x2.0x0.5)m plinth.
29R.C.C. work in ratio 1:2:4 (cement, coarse sand & stone grit) of 20m size for making plinth of size 2x(2.0x2.0x1.0)m and grouting of foundation bolts 04 Nos. for 33 KV VCB.
3012mm thick plaster with cement mortar in ratio 1:4 (cement & fine sand) of plinth of 0.4m upper side
31Earthing of Power T/F, details as given below:-
32Water level earthing by Boring and lowering of G.I. pipe size 40 mm dia & thickness 3mm into the ground at 20 Mtr depth or upto the water level with the lower end of solid copper cone Approx 225 mm long and 750 gm in weight shall be provided and screwed in pipe as well as bringing out a continuous copper wire 6 SWG from the cone up to the ground surface where it will be bolted to the G.I. earth Strip for Transformer neutral connection, the G.I.Earth strip size 50x6mm will be welded to the G.I. pipe and neutral earthing support & other installed equipment in switchyard. All required material provided / supply by the contractor own his cost.
33Removal of existing 05 MVA Transformer and other accessories equipments.
34Disconnecting HT cable connection from 33KV side &11KV side of5 MVA Power transformers for removing power transformer from plinth after proper shutdown. Dismantling of 11KV cable support structure, copper bus bar structure, M.S.Frame etc.
35Disconnecting copper flexible/Earthing strip from Power transformer neutral & Dismantling neutral earthing systemto facilitate removal of Power transformer from plinth.
36Disconnecting Earthing strip from body of5 MVA Power transformer.
37Safe Shifting of5 MVA Power transformer from existing plinth to safe place in the 33/11 KV substation switchyard.
38H.T. Power Cable Laying (11 KV 3X300sqmm):
39Laying 11 KV, (3x300) mm2 XLPE, Cable from power transformer to 11 KV incoming switch gear in the cable trench 0.45 m wide, 0.90m depth. Providing 150 mm local sand for cushion beneath and 150 mm above the cable (quality of local sand required 0.375 cum/m in length). The cable shall be dully protected by brick. On both side of cable by laying brick vertically and bricks would also be laid bricks along the single cable (minimum 18 Nos. of bricks are to be laid top and outer side along the single cable. The work includes digging of trenches, laying of cable in under ground trenches, joining of terminal’s, back filling of earth and testing and commissioning of power cable etc. Spare cable shall be left over and laid in the trenches in shape of 6 m ring at both ends.
40Preparation of 11 KV Power Cable Jointing Kits:
41Making of 11 KV XLPE Heat shrinkable Indoor/outdoor jointing kits 3x300Sq.mm after duly plumbing and taping of cable, providing, fixing and crimping of proper size good quality lugs
42Installation of 24V Battery and Battery Charger:
43Assembling and installation of the cabinet of 24V battery and battery charger in switch gear control room including grouting of foundation bolts as per drawing of manufacture, including providing the foundation nuts and bolts of proper size. The electrical connection between battery and battery charge with flexible copper lead of size 7/20 SWG shall be done properly. The work includes installation, wiring upto control panel, testing and commissioning complete in all respect.
44Laying of Control Cables (2x2.5)mm2/ (4x2.5)mm :
45Laying of different size of (2x2.5)mm2/ (4x2.5)mm2control cables i.e. from Buchholz realy to Marshalling box Marshalling box to indication protection board in switch gear room, 33 KV CT’s to CT’s Junction Box, 33 KV CT, 33 KV PT, V.C.B. Control Panel Junction Box to 33 KV VCB control panel and control panel to 33 KV VCB outdoor operating mechanism panel from T/F etc. in the cable trench including making proper connection at Buchholz Relay, Marshalling box and indication board as per required for installed equipment.
46Painting of Structures :
47Painting of the all structures with one coat of ready mixed primer and two coats of ISI Mark Aluminium paint after rubbing with sand paper to the surface of the structure including labour and T&P complete in all respect.
48Installation of 33 KV Lightning Arrestors:
49Assembling and installation/mounting of 3 Nos. lighting arrestors on the L.A.’s structure/terminal gentry, complete with earthing and line connections. The work includes fabrication for proper fixing, if required.
50Installation of 33 KV Post Insulators:
51Installation of 3 Nos. PI on structure. The work includes fabrication for proper fixing, if required.
52Installation of 33 KV VCB :
53Assembling and installation of 33 KV VCB on the VCB out door structure on the plinth. Adjustment of operating mechanism in proper alignment for smooth operation of the same. The work also includes fabrication of addition arrangement for proper fixing, if required.
54Installation of 33 KV VCB Control Panel for single T/FControl Panel.
55Carefully and safely shifting of 33 KV VCB control panel from outside of the switch gear room to inside of the switch gear room, grouting with anchor bolts in the floor, work also includes cutting & proper finishing of floor if necessary for completion of work. Placing and fixing of panel on foundation, bolts of proper size in proper position and alignment.
56Installation of 33 KV C.T.’s:
57Installation of 3 Nos. C.T.’s on the C.T’s structure. The work includes fabrication for proper fixing, if required to complete the work.
5833 KV CT’s Junction Box:
59Providing & fixing of junction box of size (400x400x150) mm made of G.I. sheet of 16 SWG in between 33 KV CT’s & control panel. The work also include making proper connection on the junction box and making all connection in between CT’s and control panel complete as per manufacture’s panel drawing including testing and commissioning of work etc. complete the work.
60Making Proper Connection on 10 MVA Power T/F 33 KV/11 KV Sides. Including welding of earthings etc.