Dakshinanchal Vidyut Vitran Nigam Limited-DVVNL has published Tender For Capacity Increasing 1X8mva Power Transformer To 1X20 Mva Power Transformer Of33/11 Kvsub-Station Cantt Mathura And Construction Of 33 Kv Line Emanating From 132 Kv Sub-Station Aurangabad Distt. Mathura, On Semi-Turnkey Basis. Submission Date for this Tender is 23-04-2024. Power Transformer Tenders in mathura Uttar Pradesh. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | SUB-STATION PART:- 33 KV Line Isolator. |
2 | 33 KV Bus Isolator. |
3 | 33 KV Lightening Arrestors |
4 | 33/11 KV Transformer 20 MVA |
5 | 33 KV VCB 800A, 750MVA with Steel structure |
6 | Control panel I/C for 33 KV single T/F |
7 | 33 KV CT 400/200/1-1A |
8 | 33 KV 1 Ph PT 33 KV/110 V |
9 | 11 KV SWITCH GEARS VCB:- (i) Incoming VCB 600/300/5A, 350MVA, I /C |
10 | (ii) Outgoing VCB 200/100/5A, 350MVA |
11 | (iv) 11 KV Adopter Protection Panel with Bus Bar Arrangement complete all accessories. (L/S Rate) |
12 | (v) HT Para Tape (L/S Rate) |
13 | (vi) Aluminium Lug 300 Sq.mm. (L/S Rate) |
14 | (vii) Four Bolt Clamp for Painther Conductor |
15 | (viii)Copper flat 2500x75x20 mm (L.S.) |
16 | 11KV 3 Core XLPE Cable:- (i)3 × 300 Sq.mm |
17 | (ii) 3 × 185 Sq.mm |
18 | 11KV Cable jointing kit. Heat Shrinkable:- (i) 300 Sq.mm Indoor |
19 | (ii) 300 Sq.mm Outdoor |
20 | (iii) 185 Sq.mm. Indoor |
21 | (iv) 185 Sq.mm. Outdoor |
22 | PCCPole 8.5 mtr. Long for Switch yard Lightening |
23 | 33 KV Terminal Gantry with Plinth & Foundation as per RESSPO Schedule |
24 | Structure for Line & Bus Isolator. with Plinth & Foundation |
25 | 33 KV Post Insulator |
26 | Structure for Post Insulator with Plinth & Foundation |
27 | Structure for Lightening Arrestors with Plinth & Foundation |
28 | 105 Lbs. Rail pieces for T/F |
29 | CT Steel structure with Plinth & Foundation |
30 | Structure for P T with Plinth & Foundation |
31 | 33 KV Fuse Set |
32 | Structure for fuse Set with Plinth & Foundation |
33 | 24 V Battery with Battery Charger and Cabinet. |
34 | Control cable:- (i) 4 × 2.5 Sq.mm. |
35 | (ii) 2 × 2.5 Sq.mm. |
36 | L.T. Cable Al. 3.5x70 Sqmm. |
37 | Earthing of Sub-Station:-(As per RESSPO Schedule) (i) Outdoor Equipment (Earth Mat) |
38 | (ii) Indoor Equipment (Earth Mat) |
39 | Water levelPipe Earthing for Power T/F |
40 | Chemical Pipe Earthing |
41 | CONDUCTOR A.C.S.R. Panther conductor for switch yard |
42 | CONDUCTOR A.C.S.R. Dog conductor for switch yard |
43 | PG Clamp for Panther to Dog Conductor |
44 | PG Clamp for Panther to Panther Conductor |
45 | G.I. Nut, Bolt and Washer"s |
46 | Alluminium Paint for painting of Sub-Station Structure & equipment. |
47 | Red Oxide Paint for painting of Sub-Station Structure & equipment. |
48 | Plinth of 20 MVA T/F 5x5 Mtr. As per drawing with Transformer Cable Stand made by G.I. 65x65x6 mm 3.00 Mtr. Long angle with use of flat 50x6 mm piecees and100x50x6 mm L-shape channelfor Power Transformer nutral earthing |
49 | Plinth & Foundation of 33 KV VCB |
50 | 11 KV Cable laying Including cost of sand and Bricks |
51 | Furniture for control room (Office Chair-2 no ,Office Table -2 No. Sitting branch-1 no. (made of steel) Stool -2 no.(made of steel) Office rack-1 no (made of steel) Fire Fighting equipment with stand complete. Fire extinguisher CO2 type 5.0 Kg no-1 ,Fire extinguisher CO2 type 4.5 Kg.no-1, I.S.I. mark. ,Fire Bucket stand size 1500x1200mm.-no-1, Fire bucket made ofB.P. sheet 20 gage ( conical shape ) having capacity 10 Ltr.- 10” dia -4 no., Chakkered rubbur sheet 2000x1000x10 mm. I.S.I. mark.-no-4, Tool kit Boards OF S/S making and fixing of protection Board alongwith all accessories complete made of sunmica 10 mm sheet size 45×60 Cm.-no-2 ,Supply and fixing of sub-station name board made of M.S. Angle 50×50×6 mm and S.P. Sheet of 18 SWG including painting and writing.-no-1 |
52 | SWITCH YARD LIGHTING ARRANGMENT stone Pade -6 No Cu. PVC Cable 2x4 SQMM -200 Mtr PVC Conduct Pipe -15 mm- 150 Mtr D.P.Switch 63 A for one way control-01 No. Rest for DI Board, D.P. Switch32A-1, D.P. Switch 16 A-1, Kit Kets-6 including wiring.-1 Job LED Light 100 W -6 No.(ISI Mark) |
53 | Dismentling and ShiftingCharges of 11 KV VCB,sform old control room to new Control room |
54 | Dismentling and ShiftingCharge of8 MVA T/F form 33 /11 KV Sub-station Cantt Mathurato Store Mathura |
55 | 33 KV LINE PART:- 11 Mtr. long S.T. Pole |
56 | 33 KV XLPE Cable 3 x 300 Sq mm |
57 | 33 KV Heat Shrinkable cable boxes for 33 KV Cable XLPE 3 x 300 Sq mm |
58 | 33 KV Pin Insulator |
59 | 33 KV Pin with nut |
60 | Earthing complete |
61 | Disc Insulators B&S Type 7000 Kg. |
62 | Disc Fittings for Dog/Raccoon 7000 Kg. |
63 | Stone Pad |
64 | Barbed wire |
65 | The Grouting and making of plinth of the support (1/6 of the full length of the supports) will be done as per norms in the CC 1:4:8 with cement, course sand and brick ballast including back filling and proper ramming.fixing of all clamps and other accessories as per relevant drawing. i)11 Mtr. Long SP-55 poles |
66 | Alluminium Binding wire 6 SWG |
67 | Number Plate with Clamp. |
68 | Danger Board with clamp |
69 | M.S. Bolts, Nuts & Washers |
70 | Aluminum Paint |
71 | Red Oxide |
72 | Earth wire clamp with nut& bolt |
73 | Top Channel 125x65x3200 mm. with Clamps |
74 | P.G. Clamp for Dog Conductor |
75 | ‘E’ Bracket for 33 KV |
76 | Droper Channel 100 x 50 x 3000 mm.with .Clamps. ( for Cable supporting ) |
77 | Lug 300 sqmm |
78 | Insulated Dog Conductor for Cable Connection |
79 | HDPE Pipe 160 mm O/D PN-6, PE-100 Grade UV Stabalized for laying at DoublePole Structure to proposed Double Pole Structure |
80 | G..I. Pipe 160 mm for Double Pole Structure |
81 | Clamps for fixing of Cable and Cable Box |
82 | Clamps for holding of G.I. Pipe 160 mm |
83 | Cable Marker |
84 | Wooden Bushes |
85 | 33 KV Cable Under Ground Work :- Digging of Trench by excavation of earth laying of brick to cover the cable and filling of sand &earth ramming and dressing properly with complete job for laying 33 KV XLPE cablesin loop of sizes 3x300 Sq.mm. including cost of bricks, sand, clamps etc. |
86 | Laying of H.D.P.E. Pipe underground minimum 2.5 Meters below by HDD Method along with laying of 33 KV 3x300 Sq. mm. XLPE Cable in H.D.P.E. Pipe |
87 | Laying of 33 KV, 3x300 sq.mm. XLPE Cable underground in trunches. |
88 | Laying of 33 KV, 3x300 XLPE Cable in G.I. Pipe on Double Pole Structure |
89 | Laying of 33 KV, 3x300 XLPE Cable in Air on Double Pole Structure |
90 | Choping of branches of Tree |
91 | Road restoration charges for Kachhcha / footpath side |
92 | Carriage of following material from Center Store to Site Sub StationPART:- 33/11 KV Transformer 20 MVA |
93 | 33 KV VCB 800A, 750MVA with Steel structure |
94 | Control panel I/C for 33 KV single T/F |
95 | 33 KV CT 400/200/1-1A |
96 | 33 KV 1 Ph PT 33 KV/110 V |
97 | 11 KV SWITCH GEARS VCB:- (i) Incoming VCB 600/300/5A, 350MVA, I /C |
98 | (ii) Outgoing VCB 200/100/5A, 350MVA |
99 | PCCPole 8.5 mtr. Long for Switch yard Lightening |
100 | 33 KV LINE PART:- 11 Mtr. long S.T. Pole |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy