Border Security Force-BSF has published Tender For Augmentations And Replacement Of Defective Over Head Line Into Ug Cable With Bifurcation Of Essential And Non Essential Power Supply From Substation To Shq Adm Block Under Shq Bsf Kupwara. Submission Date for this Tender is 27-04-2024. Overhead Line Tenders in kupwara Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

43181433
Tender For Augmentations And Replacement Of Defective Over Head Line Into Ug Cable With Bifurcation Of Essential And Non Essential Power Supply From Substation To Shq Adm Block Under Shq Bsf Kupwara
Open Tender
Indian
Jammu And Kashmir
kupwara
27-04-2024

Tender Details

Augmentations And Replacement Of Defective Over Head Line Into Ug Cable With Bifurcation Of Essential And Non Essential Power Supply From Substation To Shq Adm Block Under Shq Bsf Kupwara As Per Work Schedule

Key Value

Document Fees
Refer document
EMD
INR 11802.0 /-
Tender Value
INR 5.90 Lakhs /-

BOQ Items

Name of work:-Augmentations & Replacement of defective over head line into UG Cable with bifurcation of essential & non essential power Supply from substation to SHQAdm block under SHQ BSF Kupwara
Sl. No. Item Description
1Supplying andLaying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in groundin the existing RCC/ hume / meta l/ DWC HDPE pipe (of item no 5) including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.(I)3.5x50sq. mm
2Supplying andLaying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in groundin the existing RCC/ hume / meta l/ DWC HDPE pipe (of item no 5) including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.(II)3.5x95sq. mm
3Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size armoured alluminum conductorin the existing RCC/ HUME/ METAL pipe as required for road crossing in already laid pipe. (I)3.5x50sq. mm
4Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size armoured alluminum conductorin the existing RCC/ HUME/ METAL pipe as required for road crossing in already laid pipe.(II)3.5x95sq. mm
5Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade offollowing size armoured alluminume conductorin the existing masonry open duct/on air/along the existing pole as required. (I)3.5x50sq. Mm
6Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade offollowing size armoured alluminume conductorin the existing masonry open duct/on air/along the existing pole as required. (II)3.5x95sq. Mm
7Supplying and making end termination with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE aluminum conductor cable of 1.1 KV grade as required. (I)3½ X 50 sq. mm (35mm)
8Supplying and making end termination with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE aluminum conductor cable of 1.1 KV grade as required.(II)3½ X 95 sq. mm (45mm)
9Supplying and laying of following sizeDWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc.conforming toIS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. (I)90 mm dia (OD-90 mm & ID-76 mm nominal)
10Supplying and laying of following sizeDWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc.conforming toIS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. (II)120 mm dia (OD-120 mm & ID-103 mm nominal)
11Providing, installation and testing of415 V, 3 phase, 4 wire, 50 Hz A.C. outdoor type (Water proof) Cable Junction box of sixe 600mmx600mm x450mm deepfabricated out of 2 mm thick CRCA sheetcomplete with having locking arrangement and providing detachable gland plate at thebottom of the panel, earthing stud (02 nos) complete with 400 amps 4 nos Aluminum bus bar R,Y,B & N (Black), with LED Pilot light (22.5 mm dia) with protection MCBs -03 Nos suitable rating insulators, duly painted with powder coated of approved colour, brand &having 04 nos legs (minimum height 60cm) welded with the base made out of 50mm X 50mm X 5mm angle iron duly paintedof suitable size of the joint box to be fixed on ground with 1:3:6 cement concrete foundation etc complete as required. The location , size of cable should be marked with the radium on the panel as per the direction of Engg in charge.(Joint Box should beas per design &drawing approved by Engg in charge)
12SITC of indoortype compartmentalized panelup to depth of 450 mmas per drawing (to be given by Engg in charge)suitable for 415 Volt, 3 phases, 50 Hz made out of 2 mm thick CRCA sheet with required hardware duly painted with powder coated .Panel having separate detachable gland plate, both side opening with locking arrangment, earth bar/stud,400A/415V 8 strip aluminum bus bar (for two panel) duly PVC sleeved, connection inter–connection withbus bars having 25% extra capacity of the rated MCCBswith spreader links and solid copper conductor cable 10 sqmm/ solid aluminium rod for MCBs (where required) for incoming/Outgoing cables, links forspare MCCBs, heavy duty connectors/ terminals for three and single phase cable connections for MCBs and fixing the panel on angle iron frame duly painted ofsuitable sizeof panel made out ofsize 50mmx50mmx5mmminimum height from floor 30cm including small panel fan -02 nos with louvers for exhaust etc complete as required and dismentling the existing panel , incoming/outgoing connection wires etc complete as required.Panel should have following instruments mounted on it andall the distribution locations marked on it(Panel size should beas per design &drawing approved by Engg in charge).
13Instruments:- (i) VAF Digital voltmeter/Ampere/frequency meter of size 96 sqmm x 96 sqmm flush mounted minimum range 0-500 V/A(2 No.)(ii)CT"s ratio 200/5-04 set, 100/5 -04 set.(iii) LED Pilot light (22.5 mm dia) with protection MCBs -06 Nos
14Providing and fixing following rating and breaking capacity Triple pole 415 volt MCCB with thermomagnetic release with spreaders link in existing cubicle panel board ( in item no 10) including drilling holes in cubicle panel, making connections, etc. as required.(As per direction of engg incharge)63 Amp TPMCCB 16 KA
15Providing and fixing following rating and breaking capacity Triple pole 415 volt MCCB with thermomagnetic release with spreaders link in existing cubicle panel board ( in item no 10) including drilling holes in cubicle panel, making connections, etc. as required.(As per direction of engg incharge) 100 Amp, TPMCCB15-18 KA
16Providing and fixing following rating and breaking capacity Triple pole 415 volt MCCB with thermomagnetic release with spreaders link in existing cubicle panel board ( in item no 10) including drilling holes in cubicle panel, making connections, etc. as required.(As per direction of engg incharge) 125 Amp, TPMCCB 15-18 KA
17Providing and fixing following rating and breaking capacity Triple pole 415 volt MCCB with thermomagnetic release with spreaders link in existing cubicle panel board ( in item no 10) including drilling holes in cubicle panel, making connections, etc. as required.(As per direction of engg incharge)200 Amp,TPMCCB 25 KA,
18Providing and fixing following rating onload changeover switch Conforms to IEC 947-3, EN - 60947-3 AC-23A, Front operated 4 Pole 415V, 50Hz. (Open execution) in existing cubicle panel board ( in item no 09) including drilling holes in cubicle panel, making connectionsi/c dismentling the existing feeder pilar alongwith electrical acessories.320 Amp
19Drilling the road without breaking the road surface (Asphalt) for laying of cable for feeding power supply by making up to following size of holes at both ends complete. Up to 110 mm bore dia