National Institute Of Technology-NIT has published Tender For Electrical Renovation Of Mba Hostel A Block To Accommodate International Students, Including Kitchen Facilities. Submission Date for this Tender is 07-05-2024. Electrification Work Tenders in calicut Kerala. Bidders can get complete Tender details and download the document.
FileName | File Description | File Size |
c1b62d6f-4984-40c2-9f0d-639ae22e015c.html | Tender Notice | 0 KB |
BOQ_845184.xls | Tender Document | 0 KB |
EMUJE2016LAM.pdf | Tender Document | 0 KB |
Tendernotice_1.pdf | Tender Document | 0 KB |
Sl. No. | Item Description |
1 | WIRING IN STEEL & PVC CONDUIT |
2 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable insurface /recessedmediumclassPVCconduit,withmodular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
3 | Group C |
4 | Wiringforcircuit/submainwiringalongwithearthwirewiththe followingsizesofFRLSPVCinsulatedcopper conductor,single corecableinsurface/recessedmediumclassPVCconduitas required. |
5 | 4 X 16 sq. mm + 2 X 6 sq. mm earth wire |
6 | SupplyinganddrawingfollowingsizesofFRLSPVCinsulated copperconductor, singlecorecableintheexistingsurface/ recessed steel/ PVC conduit as required. |
7 | 3 x 1.5 sq. mm |
8 | 3 x 2.5 sq. mm |
9 | 3 x 4 sq. mm |
10 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
11 | 20 mm |
12 | 25 mm |
13 | 32 mm |
14 | Supplying and fixing following modular switch/ socket on the existing modularplate&switchboxincludingconnectionsbutexcluding modular plate etc. as required. |
15 | 5/6 A switch |
16 | 2 way 5/6 A switch |
17 | 15/16 A switch |
18 | 6 pin 15/16 A socket outlet |
19 | TV antenna socket outlet |
20 | 15/16A modular socket, 3 module |
21 | 10A modular 1way switch, 2 Module |
22 | Supplyingand fixingtwo module steppedtypeelectronicfan regulatorontheexistingmodularplateswitch boxincluding connections but excluding modular plate etc. as required. |
23 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
24 | Supplyingandfixingfollowingsize/modules,GIboxalongwith modular base & cover plate for modular switches in recess etc. as required. |
25 | 1 or 2 Module (75mmX75mm) |
26 | 3 Module (100mmX75mm) |
27 | 6 Module (200mmX75mm) |
28 | Supplying and fixing suitable size GI box withmodular plate and cover in front on surface or in recess, including providing and fixing 3pin 5/6Amodularsocketoutlet and 5/6Amodularswitch, connections etc. as required. |
29 | Supplying and fixing suitable size GI box withmodular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 &15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
30 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
31 | Supply and fixing following size DLP plastic trunking including all necessory accessories. |
32 | DLP Pastic Trunking105x50mm with cover including all accessories (end cap, junctions, joints, wall crossing, VDI accessories etc. as per site condition) |
33 | MCCB, MCB & DB"S |
34 | Supplying and fixing following way,horizontal type three pole and neutral,sheetsteel,MCBdistributionboard, 415V,onsurface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
35 | 6 way (4 + 18), Double door |
36 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles intheexistingMCBDBcompletewithconnections,testingand commissioning etc. as required. |
37 | Single pole |
38 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
39 | Supplying and fixing followingrating, four pole, (threephase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30mA in the existingMCBDB complete with connections, testing and commissioning etc. as required. |
40 | 63A |
41 | Supplying and fixing 40 A to 63 A rating, 415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles intheexistingMCBDBcompletewithconnections,testingand commissioning etc. as required. |
42 | 4P 63A |
43 | TP 40-63A |
44 | MISC. CIVIL ITEMS |
45 | Providing brick work (in width 225 mm or more) with F.P.S. bricks of class designation 7.5 in cement mortar 1:4 (1cement : 4 coarse sand) at all levels. |
46 | Providing 15mm thick cement plaster of mix 1:4 (1cement : 4 fine sand) at all levels, |
47 | BLDC |
48 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLOC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
49 | ELECTRICAL FIXTURES |
50 | Indoor Lighting |
51 | Supply and fixing of following LED Luminaires |
52 | 1x1 or nearest size of 15/18 W surface mounting type (square type), 5700K, CRI >80, Efficacy >100 lm/watt, THD <10%cool white LED luminaire with white flat light opal diffuser, Robust PDC aluminum housing with LEDs complete with all accessories etc, as required. (Crompton -LCTLSNE-18-FO-CDL(1X1)) *** Bidder should submit OEM warranty certificate minimum 02 year or above along with supply of product at site. |
53 | 18/20 watt 4 feet T8 LED tube with efficacy 100lm/W. (T8 LED-Crompton LGT8-20-865-2 or compatible) |
54 | Box type tube fittings (Batten ), complete with side holders etc, as required.(Batten- Crompton ECO DIJB12LT8-20 1XT8 or compatible) |
55 | LED Bulk head Luminaires 10W(Crompton SUNRISE,LBHE-10-WW/T/CDL or equvalent) with Efficacy >100 lm/W, CCT>3400K (WW/CDL/T) ANSI, IP 65 Protected.Including necessory clamps, screws, fastners etc. as required. |
56 | Skirting light with white LED (3 module) onthe existing switch box/ cover including connections etc. as required. (Legrand or equvalent) |
57 | 10 watt 2 feet LED batten with efficacy 100lm/W. (LED-Crompton CCS-103-10-65-SL-DP-NWH or compatible) |
58 | 5 watt 1 feet LED batten with efficacy 100lm/W. (LED-Crompton CCS-103-05-65-SL-DP-NWH or compatible) |
59 | Supply and fixing of following Exhaust Fan with necessory arrangement |
60 | Supplying and fixing of 150mm sweep ventilating fan speed~1350rpm with back flaps including connection etc. as required. Make: crompton/almonard or Equivalent |
61 | LABOUR |
62 | Removing of following items and handing over to EMU safely. |
63 | Removing tube light and fixture with/with outrad/clamp from cealing/wall handing over to EMU store safely as required. |
64 | Removing cealing fan withrad, regulator from switch board, handing over to EMU store safely including stacking of fan leafs as required. |
65 | Removing of point wiring including cealing rose, conduit, wires, switches(modular/piano type) switch board, clamps etc. as required and handing over to the store/yard. |
66 | Removing of switch board of any size including wires, switches(modular/piano type) switch board, clamps etc. as required and handing over to the store/yard. |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail