Tender For Improvement To Certain Smq / Omq At Afs Salua; 1 Taking Down Cement Plaster Of Any Description On Brick Or Stone Walls, Etc. Including Raking Out Joints, Hacking For Key, Scrubbing Down With Water Etc And Removing The Debries Outside Of Mod Land, Complete All As Specified And Directed. 2 Demolition Of Un-Reinforced Cement Concrete Of Any Description And In Any Position Not Otherwise Specifically Provided For And Disposal Of Unserviceable Materials, Debris And Rubbish To A Distance Not Exceeding 100 M, Complete All As Specified And Directed. 3 Cutting Holes In Brick Walls Built In Cement Mortar Or Cement Lime Mortar And Stone Walls For Inserting Holdfasts And Making Good Dismantled Portion In Cement Mortar 1:3 Or In Cement Concrete 1:2:4 Type B-1 ( 20Mm Graded Stone Aggregate ) Exc Half Brick But Not Exc One Brick Thick, Complete All As Specified And As Directed. 4 Dismantling Floor, Hearth Or Wall Tiling Including Cement Mortar Bedding ( But Not Backing ) , Removing Serviceable Tiles To Store And Rubbish Off The Premises, Complete All As Specified And Directed. 5 Taking Down Chowkats Or Frame, N.Exc 1.5 Sqm Each With Shutters ( Without Taking Off Shutter From The Frame ) Complete All As Specified And Directed. 6 Demolition Of Stone Slabs And Tiles Of Any Description Or Any Thickness In Floors, Aprons Etc Laid, Bedded And Pointed In Cement Mortar Complete All As Specified And Directed. 7 Taking Up Or Down Gi Tubing Of 15Mm Bore And Connections, Including Cleaning For Refixing Or Removal To Store, Complete All As Specified And Directed. 8 M&L Brickwork With Fly Ash Bricks, Straight Or Curved On Plan Exc6m Mean Radius Built In Cement Mortar 1:6, Complete All As Specified And Directed. 9 M & L For Rendering 15 Mm Thickon Fair Faces Of Brick Work Or Concrete Surfaces In Cement Mortar 1:4 And Finished Even And Smooth Without Using Extra Cement, Complete All As Specified And Directed. 10 M & L For Rendering 15 Mm Thickon Other Than Fair Faces Of Brick Work Or Concrete Surfaces In Cement Mortar 1:4 And Finished Even And Smooth Without Using Extra Cement, Complete All As Specified And Directed. 11 Supply Only Liquid Water Proofing Compound Approved Quality, Complete All As Specified And Directed. 12 M & L Forpcc ( 1:2:4 ) Type B-0 ( Using 12.5Mm Graded Stone Aggregate ) As In Roof Paddingincluding Formwork, If Required, Complete All As Specified And Directed. 13 M&L For Non Skidcoloured Ceramic Tiles 7 To 8 Mm Thick ( Square / Rectangular ) Area Of Each Tile Exceeding 0.11 Sqm But N.Exc 0.18 Sqm, In Floors Etc, Set And Jointed In Neat Cement Slurry And Pointed With White Or Coloured Cement To Match Over And Including 15Mm Thick Screed Bed Of Cement Mortar 1:6, Complete All As Specified And Directed. 14 M&L For Non Skidcoloured Ceramic Tiles 7 To 8Mm Thick Of Approved Shade And Pattern ( Square / Rectangular ) Area Of Each Tile Exceeding 0.18 Sqm But N.Exc 0.38 Sqm, In Floors Etc, Set And Jointed In Neat Cement Slurry And Pointed With White Or Coloured Cement To Match Over And Including 20Mm Thick Screed Bed Of Cement Mortar 1:6, Complete All As Specified And Directed. 15 M&L For Non Skidcoloured Ceramic Tiles 7 To 8Mm Thick Of Approved Shade And Pattern ( Square / Rectangular ) Area Of Each Tile Exceeding 0.18 Sqm But N.Exc 0.38 Sqm, As In Skirting, Dado, Riser To Steps Etc, Etc, Set And Jointed In Neat Cement Slurry And Pointed With White Or Coloured Cement To Match Over And Including 10Mm Thick Rendering In Cement Mortar 1:4, Complete All As Specified And Directed. 16 M&L Forglazed Coloured Ceramic Tiles Of Size 350X250x7mm / 450X300x7mm To 8Mm Thick In Vertical Surface Set And Jointed In Neat Cement Slurry Pointed With White Or Coloured Cement To Match Over And Including 10Mm Thick Rendering Incement Plaster 1:4, Complete All As Specified And Directed. 17 M&L For Scratch Free Dark Shade Vitrified Ceramic Tiles 10 Mm Thick ( Square / Rectangular ) Polished, Area Of Each Tiles Not Exceeding 0.36 Sqm, In Floors Etc. Set And Jointed In Neat Cement Slurry And Pointed With White Or Coloured Cement To Match Over And Including 20Mm Thick Screed Bed Of Cement Mortar 1:6, Complete All As Specified And Directed. 18 M&L For Scratch Free Dark Shade Vitrified Ceramic Tiles 10 Mm Thick ( Square / Rectangular ) Polished, Area Of Each Tiles Not Exceeding 0.36 Sqm, As In Skirting, Dado, Riser To Steps Etc, Set And Jointed In Neat Cement Slurry And Pointed With White Or Coloured Cement To Match Over And Including 10Mm Thick Rendering In Cement Mortar 1:4, Complete All As Specified And Directed. 19 M&L For 18-20Mm Thick Granite ( Of Any Type ) Tiles Machine Cut, Bedded And Jointed With Grey Cement Slurry And Pointed With White Cement With Admixture Of Pigment To Match The Shade Of Granite Stone Including Grinding And Polishing Complete As In Floor, Cooking Platforms And Like Complete Over And Including 15Mm Thick Screed Bed In Cement Mortar 1:6, Complete All As Specified And Directed. 20 M & L For Pcc ( 1:2:4 ) , Type B-1 ( Using 20 Mm Graded Crushed Stone Aggregate ) In In Lintels Upto 1.5M Clear Span, Cills, Steps; Seismic And Other Similar Bands, Plinth Courses, String Courses, Lacing Courses, Parapets And Railings Upto 60 Cm In Height, Copings, Kneelers, Apex Stones, Bed Plates, Kerbs, Water Troughs And The Like Including Weathering, Slightly Rounded Or Chamfered Angles And Throating, Including Formwork If Required , Upto A Height Of 10.00 Mtr Including Necesasary Scaffolding Complete All As Specified And As Directed 21 M & L For Steel Formwork To Sides And Soffits Of Floor Or Roof Beams, Beam Haunchings, Girders, Bressummers, Lintels, Cantilevers, Shelves Including Supports, Overhangs, Etc. Also Splays Between Floors And Beams, Etc ( Rough Finished Surfaces ) Complete All As Specified Anddirected. 22 M & L For Steel Form Work To Side Of Concrete Foundations, Footings, Bases Of Columns, Raft And Raft Beams, Sides And Soffits ( If Any ) Of Foundation And Plinth Beams; And Similar Work; Vertical Or To Batterfor Rough Finished Surface Of Concrete In Flat Complete All As Specified And Directed. 23 M & L For Steel Form Work To Sides Of Pillars, Posts, Struts, Piers, Columns And Stanchions And Similar Work Vertical Or To Batterfor Rough Finished Surface Of Concrete In Flat Complete All As Specified And Directed. 24 M&L Reinforced Cement Concrete M 25 ( Design Mix ) Using20mm Graded Aggregate In Beams, Cantilevers, Bressummers, Lintels Over 1.5M Span And The Like Complete All As Specified And Directed. ( Note : Reinforcement And Form Work Will Be Measured And Paid Separately Under Relevant Items ) 25 M&L For Rcc M-25 ( Design Mix ) ( Using 20Mm Graded Crushed Stone Aggregate ) As In Foundations, Including Rafts, Footings, Foundation Beams; Etc; Basement Slabs, Under-Reamed Piles And Mass Concrete Complete All As Specified And Directed. ( Note : Reinforcement And Form Work Will Be Measured And Paid Separately Under Relevant Items ) 26 M&L Reinforced Cement Concrete M 25 ( Design Mix ) Using20mm Graded Aggregate In Columns, Pillars, Piers, Posts And Struts And The Like Complete All As Specified And Directed. ( Note : Reinforcement And Form Work Will Be Measured And Paid Separately Under Relevant Items ) 27 S & F Tmt Steel Bars 10 Mm Dia And Over Cut To Length, Bend To Shape Required, Including Cranking, Bending Spirally For Hooping For Columns, Hooking Ends And Binding With And Including Mild Steel Wire ( Annealed ) Not Less Than 0.9 Mm Dia Or Securing With Clips Quality Complete All As Specified And Directed. 28 S & F Mild Steel Tmt Bars 5Mm Dia And Over Upto And Including 10Mm Dia In Strirrups, Spacers And Binders Spirally For Hooping For Columns, Hooking Ends And Binding With Mild Steel Wire ( Annealed ) Not Less Than 0.9 Mm Dia Or Securing With Clips Etc Complete All As Specified And Directed. 29 M&L For Pcc ( 1:4:8 ) Type D-2 ( Using 40Mm Graded Stone Aggregate ) As In Foundation Filling And Mass Concrete Complete All As Specified And As Directed. 30 Excavation In Trenches, N Exc 1.5 M Wide And N Exc 1.5 M In Depth For Foundation, Etc. Or For Shafts, Wells, Cesspits, Manholes, Pier Holes, For Lying Of Cable Etc. N Exc 10 Sq M On Plan And N Exc 1.5 M In Depth And Getting Out In Hard / Dense Soilcomplete All As Specified And Directed. 31 Excavation In Trenches, N Exc 1.5 M Wide And N Exc 1.5 M In Depth For Foundation, Etc. Or For Shafts, Wells, Cesspits, Manholes, Pier Holes, For Lying Of Cable Etc. N Exc 10 Sq M On Plan And N Exc 1.5 M In Depth And Getting Out In Soft / Loose Soilcomplete All As Specified And Directed. 32 Returning, Filling In, Including Spreading, Levelling, Watering And Well Ramming In Layers Not Exc 25 Cm In Hard / Dense Soil Complete All As Specified And As Directed. 33 Returning, Filling In, Including Spreading, Levelling, Watering And Well Ramming In Layers Not Exc 25 Cm In Soft / Loose Soil Complete All As Specified And As Directed. 34 Removing Excavated Material ( Soils ) To A Distance Exc. 250M But Not Exceeding 1.5 Km Including Loading / Unloading Etc And Depositing Where Directed At A Level N Exc. 1.5 M Above The Starting Pointcomplete All As Specified And As Directed 35 Removing Excavated Material ( Soils ) To A Distancenot Exc. 50M And Depositing Where Directed At A Level N Exc. 1.5 M Above The Starting Pointcomplete All As Specified And As Directed 36 M & Lfor Sand Cushioning Foror Filling Under Floor Or In Foundations Or Under Ground Cable With Locally Available Sand For Protection Of Cable Including Spreading And Consolidations, Complete All As Specified And Directed. ( Note:- Thickness After Consolidation Be Measured For Payment ) 37 M & L For Preparation Of New Plastered Surfaces Of Wall And Applying Two Coats Of Oil Distemper Emulsion ( Ist Quality ) Of Approved Manufacturer Over A Coat Of Priming Paintover And Including 2Mm Thick Wall Care Puttycomplete All As Specified And Directed 38 M & L Forpreparation Ofnewly Plastered Surfaces Of Wall And Applying Two Coats Ofcement Base Paint Over A Coat Of Alkali Resistant Primer , Complete All As Specified And Directed. 39 M & L Forpreparation Of Old Plastered Surfaces Of Wall And Applying Two Coats Ofoil Distemper Emulsion ( Ist Quality ) Of Approved Manufacturerover A Coat Of Primer Paint, Complete All As Specified And Directed. 40 M & L Forpreparation Ofnewly Plastered Surfaces Of Wall And Finishing Walls With Premium Acrylic Smooth Exterior Paint With Silicone Additives Of Required Shade: New Work ( Two Or More Coats Applied @ 1.43 Ltr / 10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg / 10 Sqm Over New Surfaces, Complete All As Specified And Directed. 41 M & L For Providing Precast Cement Concrete Louvres And Jallies, 45Mm Thick ( Mea Sured Solid ) , Including All Mouldings But Excluding Frame, Type B-0 1:2:4 ( 12.5Mm Graded Agg. ) Set In Cm ( 1:4 ) Of Size 600X600mm , Design As Approved By Ge Complete All As Specfied And As Directed. 42 S & F Steel Windows With Side Hung Shutter Including Projecting Type Hinges As With Steel Handle, Steel Peg Stay Complete With Glazing Bars Dovetailed Or Welded Including Double Lead For Glass And Wiremesh Complete All As Specified And Directed. 43 S & F Steel Windows With Side Hung Shutter Including Projecting Type Hinges As With Steel Handle, Steel Peg Stay Complete Without Glazing Bars Dovetailed Or Welded Including Double Lead For Glass And Wiremesh Complete All As Specified And Directed. 44 S&F 3Mm Thick Sheet Glass, Ordinary Quality And Glazing In Aluminium Section In Square Not Exc 0.5 Sq. M In Each Pane Complete All As Specified And Directed. 45 S & Fstainless Steel Wire Cloth. 0.36Mm Nominal Dia Of Wire And Average Width Of Aperture 1.40Mm And Fixed With Stainless Steel Wire Staples, Complete All As Specified And Directed. 46 M & L For Preparation Of Newor Previously Untreated Steelor Iron Surfaces Of Any Description Over 10Cm Width Or Girthand Applying Two Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxideprimer Complete All As Specified And Directed. 47 Taking Down Old Roof Treatment Materials Fromsurface Of Old Concrete Roof By Picking, Sweeping Clean And Washing Down With Water Using Wire Brush Brooming Down, Removal Of Unserviceable Material Obtained From Demolition To A Distance Of N. Exc 1000Mbeyond The Lead, Including Loading, Unloading And Stacking At The Destination And Applying The Following Treatment All As Directed In Order Of Precedence As Stated :- ( I ) Rendering 15Mm Thick In Cm ( 1:4 ) On Existing Roof Surface True To Level.Ii ) Applying One Coat Of Industrial Bitumen 85 / 25 @ 1.20 Kg / Sqm. ( Iii ) Supply And Laying 3Mm Thick App Based Polymeric Membrane Of Approved Manufactured With Weight Not Less Than 3.60 Kgs Per Sqm Reinforced With Non-Woven Polyester Fabric / Matt Weighing Not Less Than 160Gms Per Sqm Having Softening Point Not Less Than 150 Mm Centigrade, Having Tensile Strength Of 650 N / 5Cm And 350 N / 5Cm In Longitudinal And Transverse Directions Respectively Of The Reinfocred Tearing Strength Of 180 N By Torch Application . Polymeric Membrane Shall Be Taken To A Height Of 30Cm ( Minimum ) And Then Inserted Inside The Groove Of Parapet Wall And Shall Be Finished By A Membrane Flashing. ( Iv ) Applying One Coat Of Aluminium Paint Over App Membrane. 48 Item No 47 Contd....Note :- ( I ) Laying App Based Polymeric Membrane Shall Be Done Torch On Method As Per Manufactures Instructions. . ( Ii ) A Minimum Overlap Of 100Mm And 75Mm Should Be Made At The Endand Sides Of The Polymeric Membrane Respectively And Sealed Alloverlaps And Joints As Per Manufacturers Instruction. ( Iii ) App Based Polymeric Membrane Shall Beof Any One Of The Approved Makes As Specified Here-In-After And Shall Conform To Specifications Given In Is 16540-2017 / Is 16532-2017. ( Iv ) Contractor Shallproduce Necessary Test Certificate Of The Manufacturer To The Engr-In-Chage Before Incorporation In The Work. ( Vi ) Necessary Independent Tests Shall Also Be Carried Out By The Contractor Without Any Extra Cost To The Deptt As Per Relevant Is Specifications And Membranes With Satisfactory Test Results Shall Only Be Incorporated In The Work ( Vii ) The Work Shall Be Executed Through Authorised Applicators Of Original Manufacturer Only ( Viii ) Removal Of Surplus Materials To A Distance Not Exc 1000M Beyond The Lead Is Deemed To Be Included In The Quoted Rate Of Item. 49 S&F Gi Tubing Of 15Mm Dia Medium Grade With All Fitting And Fixed Complete To Walis And Ceilings Or Laid In Floors Complete All As Specified And Directed. 50 S&F In Repairs For15mm Bore , Fancy Type Chromium Plated Bib Tap, Cast Copper Alloy With Capstan Head Long Body And Cup, Screwed Down, Screwed For Iron Pipe Or For Brass Ferrule Complete All As Specified And Directed. 51 S&F In Repair Sinks With Drainage Board Made Of Stainless Steel1 Mm Thick Kitchen Or Laboratory With Plugs, Washers And Wastes; Including Bedding In Cement Mortar To Dwarf Wall Or Including Fixing Cantilever Brackets And Connecting Union To Pipe Overall Size 915Mm X 460Mm Bowl Size 410Mm X 330Mm X 160Mm , Incl 40Mm Dia Waste Pipe Of Polythelene Of Low Or High Density, 40Mm Bore Chromium Plated Brass Waste Fitting With Long Screwed Shanks And Fly Nuts, Flange End Bedded In Red Lead Cement & Other End Fixed, Making Holes In Walls For Brackets And Fixed In Cm ( 1:3 ) If Required, Complete All As Specified And As Directed. 52 M & L For 60Mm Thick Machine Pressed Precast Concrete Interlocking Paver Block Any Shape And Size Confirming To Is 15658-2006 , M-35 Grade, Paver Block Coloured With Grey Cement And Pigment Laid Over Sand Cushioning All As Specified And Directed. ( Note : Sand Cushioning Shall Be Measured And Paid Under Respective Item ) 53 M & L For50mm Thick Pcc 1:4:8 Type D-2 Using 40Mm Graded Stone Aggregate As In Sub Base Flooring Including Formwork, If Required, Complete All As Specified And Directed. 54 M & L For Surface Excavation N Exc 30 Cm Deep And Averaging 15Cm Deep And Getting Out Soft / Loose Soil , Complete, All As Specified And Directed. 55 M & Lfor Hardcore Of Gauge N Exc. 63 Mm Broken Stone Or Boulders Deposited, Spread And Levelled In Layers N Exc. 15 Cm Thick, Watered And Rammed To A True Surface , Complete All As Specified And Directed 56 S&F Perforated Cutlery Drawerlength 500-550 Mm, Depth- Exc 490 Mm , Height -90 Mm Made Of Stainless Steel Of Grade Is:202.Includinggood Quality Telescopic Channel Set For Movement , If Required, Including Necessary Fixing Arrangement To The Kitchen Cabinet / Cupboard Boardwith Glue / Nails / Screw Etc All As Specified And Directed. 57 S&F Plain Basket Drawer Length 500-550 Mm, Depth- Exc 500 Mm , Height -100 Mm Made Of Stainless Steel Of Grade Is:202. ( Allowable Tolerance Limit 20Mm In Dimension ) Including Good Quality Telescopic Channel Set For Movement, If Required, Including Necessary Fixing Arrangement To The Kitchen Cabinet / Cupboard Boardwith Glue / Nails / Screw Etc All As Specified And Directed. 58 S&F Cup And Saucer Basket Length 500-550 Mm, Depth- Exc 500 Mm , Height -100 Mm Made Of Stainless Steel Of Grade Is:202. ( Allowable Tolerance Limit 20Mm In Dimension ) Including Good Quality Telescopic Channel Set For Movement, If Required, Including Necessary Fixing Arrangement To The Kitchen Cabinet / Cupboard Boardwith Glue / Nails / Screw Etc All As Specified And Directed. 59 S&F Thali Basket Drawer Length 500-550 Mm, Depth- Exc 500 Mm , Height -200 Mm Made Of Stainless Steel Of Grade Is:202. ( Allowable Tolerance Limit 20Mm In Dimension ) Including Good Quality Telescopic Channel Set For Movement, If Required, Including Necessary Fixing Arrangement To The Kitchen Cabinet / Cupboard Boardwith Glue / Nails / Screw Etc All As Specified And Directed. 60 S&F D-Tray Dia Of Tray 750 Mm Dia Made Of Stainless Steel Of Grade Is:202. ( Allowable Tolerance Limit 20Mm In Dimension ) Including Good Quality Telescopic Channel Set For Movement, If Required, Including Necessary Fixing Arrangement To The Kitchen Cabinet / Cupboard Boardwith Glue / Nails / Screw Etc All As Specified And Directed. 61 S&F Auto Closing Waste Bin Made Of Stainless Steel Of Grade Is:202. ( Allowable Tolerance Limit 20Mm In Dimension ) Including Good Quality Telescopic Channel Set For Movement, If Required, Including Necessary Fixing Arrangement To The Kitchen Cabinet / Cupboard Boardwith Glue / Nails / Screw Etc All As Specified And Directed. 62 S&F Bottle Pull Out Made Of Stainless Steel Of Grade Is:202. ( Allowable Tolerance Limit 20Mm In Dimension ) Including Good Quality Telescopic Channel Set For Movement, If Required, Including Necessary Fixing Arrangement To The Kitchen Cabinet / Cupboard Boardwith Glue / Nails / Screw Etc All As Specified And Directed. 63 S & Ffactory Made Ready To Install Non-Toxic, Lead & Cadmium Free, Single Extruded, Water Proof, Termite Proof, Fire Retardant, Excellent Screw Holding Capacity, Solid Pvc Boards 18Mm Thick , One Side Decorative Choice Lamination And Other Side Balacing White As In Cup Board Shutters Fixed To Door Frame With And Including Continious ( Piano ) Hinges, Stainless Steel , Bright Finish Or Electrogalvanised And Width Of Flaps 40Mm ( When Open ) And Stainless Steel Screws Completeall As Specified And Directed. 64 S & Ffactory Made Ready To Install Non-Toxic, Lead & Cadmium Free, Single Extruded, Water Proof, Termite Proof, Fire Retardant, Excellent Screw Holding Capacity, Solid Pvc Boards 18Mm Thick Ofwhite Colour In Cup Board Shelves Fixed To Guide Rails With Stainless Steel Screws Etc Including All Required Accessory And Builders Hardware If Required, Completeall As Specified And Directed. 65 S&F 35Mm Hinge With Self-Closing Cup Cc 48Mm, Clip On, 4 Hole Plate, Hinge With Arm Cover For Kitchen Cabinet / Cup Board Etc Complete All As Specified And As Directed. 66 S & F 125Mm Long Stainless Steel Mirror Finish Modular Kitchen Cabinet Handle Complete All As Specified And As Directed. 67 S & F 150Mm Long Stainless Steel Mirror Finish Modular Kitchen Cabinet Handle Complete All As Specified And As Directed. 68 S & F For Brass Knobs 35-40Mm Dia Complete All As Specified And As Directed. 69 S & F Shelf Support For Kitchen Shelves Complete All As Specified And As Directed. 70 S & F L-Clip For Kitchen Shelves Complete All As Specified And As Directed. 71 Supply, Fixing And Installation Of Wall Mounted Electric Kitchen Chimney Of Size 75Cm, Metal Body, Compact Design Havingsuction Capacity Not Less Than 1400 M3 / Hr Auto Clean Type Touch Control With Wave Sensor Duct Dia 150Mm Including Free Kit For Installation With Duct Cover Of Adequate Size , Complete All As Specified And As Directed. 72 M & L Forconcealed Sub Main Wiring With Two Single Core Pvc Insulated Unsheathed, Multistranded Flexible Copper Conductor 1100Volts Grade, Frlsh Type, Cables 4 Sqmm Drawn Through In And Including Rigid Pvc Heavy Duty Concealed Conduits Medium Grade Not Less Than 20Mm Dia Including 4 Sqmm 1100 Volts Grade, Frlsh Type, Pvc Insulated Unsheathed Multi Stranded Flexible Copper Conductor Cable As Continuous Earth Wire And Connecting To Common Earth Terminals Complete All As Specified And Directed.Note:- ( I ) Two Single Cable For Phase And Neutral One Single Core Green Earth Wire Including One Meter Pvc Conduit Is Measured As One Unit. ( Ii ) Pvc Conduit And Its Accessories Is Deemed To Be Included In This Item Rates. ( Iii ) Unit Rate Include For Cutting Chases For Conduits And Sinking For Boxes Andmaking Good To Wall, Floors Etc. 73 S & F Vertical Type Wall Mounted Storage Water Heater Of Capacity 25 Ltrs Bee 5 Star Rated Or Minimum Standing Loss Of 0.511 Kwh , 240V, 50Hz With Maximum Power Consumption Of 2 Kw , Dry Powder Fero Glass Line Coating Technology For Inner Tank With Incoloy Heating Element , Abs Outer Body , 2 Nos Pvc Connection Pipe With Length Of 450 Mm Length For Hot And Cold Water Supply With Complete Accessories Complete All As Specified And As Directed. 74 S & F Switch Socket Combination, 2 In 1, Multipurpose, Suitable For 6 Pin, 5 / 6 Amp And 15 / 16 Amp Flush Type Including Connection Complete All As Specified And As Directed. 75 M & L For Point Wiring With 1.5 Sqmm Frlsh &Pvc Insulated Unsheathed Single Core Multi Stranded Copper Conductor Concealed Type 1100 Volt Grade Drawnin And Includingnon-Metalicpvcrigid Conduit Of Minimum 20Mm Medium Gradesize For One Light / Fan Point / Bell Point Controlled By One Way Switch Including One 1.5Sqmm Pvc Insulated ( Green Colour ) Unsheathedcopperconductorfor Earth Continuity Conductor And Connected To Earth Dolly And To Be Terminatedto Newsunken / Pressedflushmetalboxesof Thickness 1.2Mm Coveredwith3mm Thick Hylum Sheetasperrequirementatsiteformounting Switches , Sockets , Fanregulatorsetcincludingtestingoncompleteallasspecifiedandasdirected.Note: - ( I ) Rate Quoted Shall Include For Cost Of Making Ms Box And Concealed In Wall Including Cutting And Sinking Of Boxes And Making Good Tothe Walls ( No Extra Payment Will Be Made For The Same ) ( Ii ) Provision Of Blank Plates As Per Site Requirement ( No Extra Payment Will Be Made For The Same ) 76 M & L Forconcealed Sub Main Wiring With Two Single Core Pvc Insulated Unsheathed, Multistranded Flexible Copper Conductor 1100Volts Grade, Frlsh Type, Cables 6 Sqmm Drawn Through In And Including Rigid Pvc Heavy Duty Concealed Conduits Medium Grade Not Less Than 20Mm Dia Including 6 Sqmm 1100 Volts Grade, Frlsh Type, Pvc Insulated Unsheathed Multi Stranded Flexible Copper Conductor Cable As Continuous Earth Wire And Connecting To Common Earth Terminalsincluding Taking Down Of Old Wiringcomplete All As Specified And Directed.Note:- ( I ) Two Single Cable For Phase And Neutral One Single Core Green Earth Wire Including One Meter Pvc Conduit Is Measured As One Unit. ( Ii ) Pvc Conduit And Its Accessories Is Deemed To Be Included In This Item Rates. ( Iii ) Unit Rate Include For Cutting Chases For Conduits And Sinking For Boxes Andmaking Good To Wall, Floors Etc. 77 S & F Copper Wound Exhaust Fan, Steel Bodymade Of Sturdy Engineering Plastic With Louvers Shutter, Ac Single Phase 230V Of Size 250Mm Sweep With, Blades, Complete With Mounting Arrangment As Per Site Requirementand Connecting Wire Up To Nearest Ceiling Rose In Flexible Pvc Pipe Complete All As Specified And Directed. 78 S & F Switch Piano Flush Type, Single Pole, One Way, 5 / 6 Amp, 230 Volts Complete All As Specified And Directed. 79 S&F Ceiling Rose, 3 Phase, Phase / Polycarbonate, Isolated Body, Complete All As Specified And Directed. 80 Material & Labour Earthing Complete Withgalvanised Steel Earth Plate Electrode 60Cmx60cmx6 Mm Thickness Burried Directly In Ground ( Earth Pit Not Less Than 2.25Mtr Deep Below Normal Ground Level ) With Top Edge Of Earth Plate Not Less Than 1.5 Mtr Below Normal Ground Level Connected To And Incl Galvanised Earth Lead Wire Of 4.00Mm Dia By Means Of Nuts & Bolts, Check Nuts And Washers Of Galvanised Incl Pcc Pit Of 1:2:4 Type B-1, Cover Reinforced With Xpmweightnot Less Than 4 Kg / Sqm And 6Mm Dia Bar Handle, Earth Pit Angle Iron Frame Of Size 25Mm X 25Mm, Excavation And Earth Work In Anytype Of Soil, Charcoal Dust, Salt, Medium Grade Gi Watering Pipe 20Mm Dia With Funnel And Wire Mesh And Light Grade Gi Protection Pipe Of 40Mm Bore From Top Edge Of Earth Plate Upto Main Distribution Board Complete Allto As Shown In Electrical Plate No 3 Of Mes Sch 2009 ( Part I ) Connected Main Switch Board All As Specified And Testing On Completion, Including Disposal Of Surplus Soil To A Distance Not Exceeding 50M , Complete All As Specified And As Directed. [ Note : ( A ) The Unit Rate Includes For Protection Pipe And Earth Lead Upto 7.5 M. Any Variation In Length Of Earth Leas And Protection Pipe Beyond 7.5 M Shall Be Measured And Paid Seperately. ( B ) Excavation / Earthwork Is Deemed To Be Included In The Quoted Rate. ] 81 Supply And Laying 50Mm Bore Gi Pipe ( Light Grade ) With All Fittings Laid In Trenches Complete All As Specified And As Directed. 82 Supply And Laying 80Mm Bore Gi Pipe ( Light Grade ) With All Fittings Laid In Trenches Complete All As Specified And As Directed. 83 Supply, Laying And Testinglt Cable Xlpe Insulated, Screened, Pvc Bedded, Galvanised Steel Strip Or Wire Armoured Electric Power Cable ( Heavy Duty ) Stranded Aluminium Conductor 1100 Volt Grade Of Size 95 Sqmm, 3.5 Core Complete All As Specified And Directed. 84 Supply, Laying And Testinglt Cable Xlpe Insulated, Screened, Pvc Bedded, Galvanised Steel Strip Or Wire Armoured Electric Power Cable ( Heavy Duty ) Stranded Aluminium Conductor 1100 Volt Grade Of Size 70 Sqmm, 3.5 Core Complete All As Specified And Directed. 85 Supply, Laying And Testinglt Cable Xlpe Insulated, Screened, Pvc Bedded, Galvanised Steel Strip Or Wire Armoured Electric Power Cable ( Heavy Duty ) Stranded Aluminium Conductor 1100 Volt Grade Of Size 35 Sqmm, 3.5 Core Complete All As Specified And Directed. 86 Supply, Laying And Testinglt Cable Xlpe Insulated, Screened, Pvc Bedded, Galvanised Steel Strip Or Wire Armoured Electric Power Cable ( Heavy Duty ) Stranded Aluminium Conductor 1100 Volt Grade Of Size 25 Sqmm, 4 Core Complete All As Specified And Directed. 87 M & L For Manual Boring Under Road And Foot Path For Inserting 40 / 50 / 80Mm Bore Gi Tubing For Drawing Ug Cable, Removal Of Soil Etc Complete All As Specified And Directed. 88 Supply, Layingin Trenches Burnt Bricks Old Size Of 230 X 115 X 75Mm Fly Ash Bricks For Cable Protectioncomplete All As Specified And Directed. 89 M & L For Fabricating, Installation, Testing And Commissioning Of Lt Bus Bar Feeder Pillar Box Outdoor Type Having Provision Of Double Door Opening Into Two Halves With Rubber Beadings Cubical Type Of Size 1.00 X 0.75 X 0.40 Mtr As Directed, Made Out Of 3.15Mm Crca Sheet Compartmentalised With Rubber Beadings, Angle Iron 40 X 40 X 5Mm Shall Be Used For Making Lugs / Frame , Duly Painted With Powder Coated Internally And Externally, Including Aluminium Bus Bar 375 Amps, And Suitable Cable Glands Of Required Size As Per Site Requirement Of Lt Cable Entry Including Foundation Work As Required At Site And Comprising Following:- ( A ) Incoming- Mccb 4 Pole 415 Volts Adjatable Thermal And Fixed Magnetic Settingicu= 100% Ics Type Of Capacity 250 Amps, 25 Ka Breaking Capacity-01 Nos ( B ) Outgoing ( I ) Mccb 3 Pole 415 Volts Adjatable Thermal And Fixed Magnetic Settingicu= 100% Ics Type Of Capacity 100 Amps, 16 Ka Breaking Capacity-03 Nos ( Ii ) Mccb 3 Pole 415 Volts Adjatable Thermal And Fixed Magnetic Settingicu= 100% Ics Type Of Capacity 63 Amps, 16 Ka Breaking Capacity-04 Nos ( C ) Led Indicating Lamps For Main Supplyindicating R, Y B- 01 Set Of 3 ( D ) Vif Digital Meter With Suitable Cts For Ampere And Voltage Display Note ( I ) Pre-Dispatch Inspection At Oem / Factory Premise Shall Be Carried Out By Rep Of Accepting Officer. ( Ii ) Prior To Manufacture, The Contractor Shall Get The Ga Drg Approved From Accepting Officer. ( Iii ) After Installation Of Transformer At Site, The Pre-Commissioning Test Shall Be Carried Out By Sei / Ei. ( Iv ) The Rate Quoted Shall Be Inclusive Of Disconnection Of All Existing Electrical Connections And Reconnecting With The New Panel With New Thimbles And Nut Bolts, Washers Etc And Taking Out Of Old Unserviceable Panels As Directed By Engineer-In Charge. 90 M & L For Fabricating / Cutting / Welding, Installation, Testing And Commissioning Of Lt Bus Bar Feeder Pillar Box Outdoor Type Having Provision Of Double Door Opening Into Two Halves With Rubber Beadings Cubical Type Of Size 1.00 X 0.75 X 0.40 Mtr As Directed, Made Out Of 3.15Mm Crca Sheet Compartmentalised With Rubber Beadings, Angle Iron 40 X 40 X 5Mm Shall Be Used For Making Lugs / Frame , Duly Painted With Powder Coated Internally And Externally, Including Aluminium Bus Bar 200 Amps, And Suitable Cable Glands Of Required Size As Per Site Requirement Of Lt Cable Entry Including Foundation Work As Required At Site And Comprising Of Mccb 100 Amps, 3 Pole -01 No As Incomer And Mccb32 Amps, 16 Ka Breaking Capacity -04 Nos As Outgoing And Suitable Insulators Complete All As Specified And As Directed. 91 Supply, Installation , Testing, Commissioning, Integration And Maintaining The Advance Metering Infrastructure ( Ami ) Of Smart Meters Of Different Makes Having Valid Bis Certification Mark With Specific Cm / L Number ( Not More Than 33% Of Particular Make ) To Ensure Interchangeability At Later Date Using Communication Technology Including Gprs / Rf / Hybrid ( Rf + Cellular ) As Per Cea / Trai Regulations In Order To Achieve Overall Economy In Operation And Maintenance . The Ami Software And Associated Infrastructure Should Be Capable Of Handling Atleast 500 Nos Of Meters In The Present Phase Of Work Of Different Makes Having Valid Bis Licence With Bis:16444 With Expansion Capacity Upto 1500 Nos Of Meters ( During Further Phases Of Smart Meters Work ) Without Any Additional Infrastructure And Cost Implication ( Except Rf / Gprs Meters, Dcu And Software As The Case May Be ) , Including Training And Knowledge Transfer, All Expenditure Incl Periodic Charges Of Telecom Operator From Installation Till Date Of Physical Completion, Obtaining Audit Of Software For Smart Meters By Cert-India Empanelled Firms / Cert Auditor Of Armed Forces, Comprising All As Specified Having Minimum Parameters / Specification As Under:- 92 Smart Rf / Cellular / Hybrid ( Rf+Cellular ) Single Phase Ac Meter Tamper Proof, Static Meter Of Class 1.0, 315 V, 50 Hz, 10 A-60 A Having Valid Bis Licence Of Is-16444 And Relevant Iec Standards With Inbuilt Radio Frequency Communication Facilitywith Self Healing Mesh Network With Default And On Demand Display, Billing Data Generation Facility, Anti-Tamper Features, Microprocessor And Led / Lcd Based Circuitry Including Smc Meter Box Of Minimum Size 250 X 250 X 160 Mm Or As Suitable For 1 Phase Meter With Viewing Glass, Concealed Hinge And Earth Bolt Plugged Complete All As Specified And Directed. Meter Should Support Sending The Following Data : 15 Min Instantaneous Data For Voltage, Current, Power Factor, Power, Cumulative Energy And Frequency, Monthly Billing Survey For Cumulative Energy And Max Demand To Software Meter Should Have Connect / Disconnect Functionality Operable From Mdm / Billing Software And Prepaid Features Would Be Mdm / Billing End As Per Prevalent Is . The Communication System Shall Support: ( A ) On Demand Energy Transfer ( B ) Two Way Communication With Dcu / Hes ( C ) Clock Synchronisation Facility With Hes ( Head End System ) ( D ) Communication Including Different Makes Of Meter Shall Be Such That It Should Communicate With Same Dcu Directly Or Via Mesh Network. ( E ) Meter Protocol Shall Be Open Interface System In Accordance Of Transmission Control Protocol / Internet Protocol. ( F ) The Cost Of The Meter Would Include 2 Years Recurring Sim Charges During The Defect Liability Period. ( G ) The Contractor Shall Keep Sufficient No Of Smart Meter In Reserve For Immediate Replacement In For Faulty Meters To Ensure Zero Downtime. 93 Contd From Boq Item No. 92Notes: ( A ) The Contractor Would Be Responsible From Removing The Existing Meter, Noting Down The Reading And Depositing It With The Mes. ( B ) It Would Be Possible To Run The Meter In Both Prepaid And Postpaid Mode ( C ) The Meters Would Carry 5 Year Warranty. ( D ) The Oem Would Need To Share The Authentication / Encryption Keys Of The Meters Along With Relevant Protocol Details With The Department. The Department Would Need Complete Support Of The Oem To Be Able To Integrate The Meter With Any Software Of The Department Choice. 94 Supply / Planning / Setup / Tuning Of Rf / Gprs / Hybrid ( Rf+Gprs ) Communication Infrastructure Including The Network Management And Headend For The Project The Ip-67 Protection Data Concentrator Units ( Dcu ) Compatible For Remote Automatic Metering Infrastructure ( Ami ) Solution And Capable Of Communicating With The Smart Energy Meter In The Corresponding Frequency Band And With The Data Server Through Gprs / Ethernet. It Would Have Internal Memory To Store Data Of At Least 200 Modules. It Would Have Inbuilt Battery Back-Up. It Would Have Ip-67 Protection. It Would Support Auto Discovery Of The Meters And Self Healing Mechanism For The Breaks In The Rf Network.It Would Have The Following Minimum Features: ( 1 ) It Shall Be Able To Configure The Communication With Underlying Nodes / Meters ( 2 ) It Should Be Able To Pull Data At Conifigurable Frequency From The Nodes / Meters. It Shall Be Able To Prioritise Control Commands. ( 3 ) Dcu Would Support On Demand Data From Nodes. ( 4 ) Dcu Would Support Data Transfer Via Cellular / Optical Fibre Communication. In Case Of Cellular Communication, It Would Support Dynamic Ip Sim From Any Telecom Service Provider ( Minimum 5G / 4G And Fallback To 3G / 2G ) Working In The Location. ( 5 ) Dcu Would Be Able To Communicate To The Nearest Meters Directly. For Farther Meters, It Would Allow Communication Through Exisiting Meters Via Mesh Or Other Formation ( Repeater Meters Etc ) . ( 6 ) Dcu Would Allow More Than One Make Of Meters For The Communication. ( 7 ) Quoted Rates Deemed To Include For Hosting And Gprs Charges / Communication Charges / Broadband Charges For Minimum 2 Years Of Defect Liability Period After Completion. ( Make : Elmeasure / Secure / Schneider / Cyan Cannode As Per Bearing Is No Is-16444 ) 95 Contd From Boq Item No. 94One Lot Of Hes ( Head End System ) / Gateway As Per Design Shall Be Capable Of Meter Data Acquisition At User Selected Period, Mantain Time Synchronism With Smart Energy / Water Meter And Mantain Communication Device Status And Will Provide Visual Interface To View The Data / Events With Following Features: ( A ) Remote Smart Meter Data Reading At Configurable Intervals ( Upto 1500 Meters ) ( B ) Acquisition Of Meter Data On Demand. ( C ) Two Way Communication With Meter / Dcu / Mdms. ( D ) Command For Connect And Disconnect The Smart Meter. ( E ) Audit Report And Event Alarm Logging. ( F ) Encryption Of Data For Source Communication. ( G ) Mantain Time Sync With Dcu / Meter. ( H ) Store Raw Data For Duration Of One Week. ( J ) Setting Of Smart Meter Configurable Parameter. ( K ) Communication Device Status And History. ( L ) Critical And Non Critical Meter Event Like Temer / Power Failure Etc. 96 Supply And Installation Of Single Phase Meter As Repeaters Complete All As Specified And As Directed. 97 Supply And Setup Of Meter Data Management ( Mdm ) System Including Supply And Configuration Of The Web Based Software With Following Modules: ( I ) Meter Data Management Modulethe Meter Data Management Module Would Be Deemed For Collecting The Data From The Meter To Dcu And Server And Vice Versa, Make The Data Available In Bidirectional Mode Ton The Currency Recharge, Online Payment Gateway, Post Paid Billing Modules, Scheduling Maintenance, Low Balance Warning, Quarter Wise Kva Allocation / Tripping, Tariff Regulations, Software Customisations Etc All As Directed By The Engr-In-Charge. ( Ii ) Secure Mobile App / Pc Based / Swipe Machine / Online Payment Gateway / All Upi Platform For All Users Assigned By The Bso / Ge ( A ) 15 Min Instantenous Data From All The Meters For Minimum Seven Parameters- Cumulative Energy, Power, Current, Voltage, Power Factor And Frequency. ( B ) Abstract Download For Monthly And Quarterly Billing Survey Data For Cumulative Energy And Max Demand And Tampering Features. ( Iii ) Billing Module: The Billing Module Capable To Create Data Sheet For Currency Recharges, Recharge History, Maximum Demand Individually, User Complaint Registers, Cheque / Payment Reconcillations, Fixed Charges, Energy Bill Details Etc. ( Iv ) Occupation And Vacation Module: Provision To Enter Admin Controls For Transfers / Vacations. The System Would Support Occupation / Vacation Based On The Unit Categories. The System Would Support Automatic Data Capture On Occupation And Vacation Events. ( V ) Customer Module: The System Would Include A Customer Portal For The Resident / Occupant To Log In And View Their Own Energy / Billing Data. There Would Be Android And Ios Mobile Apps For The User To Monitor Its Own Data And Balance On Regular Basis. 98 Contd From Boq Item No. 97.. ( Vi ) Energy Accounting Modulethe System Would Include Features Of Energy Accounting. The System Would Be Able To Account For Total Energy Block Wise, Facility Wise And Would Also Allow Calculations Of Unaccounted Energy In Case Tally With Incomer Eb Energy Meter. ( Vii ) Communication Modulethe System Would Provide Communication Of Energy Data And Bills Via Print, Email And Sms Methods. ( Viii ) Meter Master Data: The System Would Support Meter Master Data Repository. The System Would Support Meter Replacement Process. ( Ix ) Excel Export:The System Would Support Export Of Metering And Billing Data In Excel Format. ( X ) Customer Care Module - The Software Would Include A Customer Care Module Where The User Would Be Log In Any Complaints. The Service Provider Would Monitor The Complaints And Carry Out The Necessary Activities For The Complaints Resolution. ( Xi ) Meter Installation Module - The Software Would Include An App Based Meter Installation Module Where The Meter Installation Or Changes Can Be Captured On The App Itself And The Readings May Be Demonstrated To The User If Required On The App Itself. ( Xii ) Activities Communication - The Software Support Communication Of The Various Activities Such As Occupation, Vacation, Meter Change. Personal Detail Change Etc. With The User As Well As The Department On Email. ( Make For Mdms : Elmeasure / Secure / Hpl Or Any Techno Commercially Equivalent Make Approved By Ge And Make For Customer Care Solutions Module- Schneider / Innologix / Sap Orany Techno Commercially Equivalent Make Approved By Ge ) 99 Contd From Boq Item No. 97 & 98...Notes: The Additional Functional Requirements Of Mdms Are As Follows: ( A ) Asset Management:I ) Meter Location ( Apartment, Shop, Industry / Address Etc ) .Ii ) Consumer Information ( Name, Account, Id Etc ) Iii ) Meter Details ( Meter No. 1 Phase / 3 Phase, With Or Without Relay Etc ) .Iv ) Meter Configuration ( Demand Integration Period, Load Profile Capture Period Etc ) .V ) Gis Information ( Connection, Feeder / Transformer / Pole Etc ) B ) Meter Data:I ) Accept Meter Data From Hes Process, Store 1500 Meter Data At Least For 6 Month And Analyze.Ii ) Schedule And On Demand Meter Reads And Pinging Of Meter.Iii ) Storage Of All Connected Meter Events And Alarm. ( Storing Of 5 Years Data Or More Via Archiving ) Iv ) Provide Complete History And Audit Trail For All Data For 30 Days ( Configurable Period ) V ) Handle Net Metering / Meters At The Same Premises.Vi ) Manage At A Minimum 15 Mint Interval Data. ( C ) Data Validation, Estimation And Editing ( Vee ) : I ) Registered Read Data: Daily Billiing Cycle, As Well As Derived Billing Determinants Like Tou.Ii ) Interval Data: Variable Intervals And Variable Units Of Measure.Iii ) Calculated Data: Derived Or Computed Such As Determinants Billing And Aggregated Loads.Iv ) Event Data: Event And Alarm Data From Meters, Network Equipment And Mdms Itself. 100 Contd From Boq Item No. 97, 98 & 99 ( D ) Billing Determinants:I ) Configuration Multiple Tou / Tod Options By Customer Type, Day Type ( Weekend, Weekdays, And Holidays ) And By Season.Ii ) Processing Of Interval Data Into Billing Determinants.A ) Total Consumptionb ) Consumption In Different Time Blocks For Tou Billing.C ) Maximum Demand ( Kw And Kva ) D ) Number Of Tamper Countse ) Average Power Factorf ) Ability For Check Metering, Sub Metering Prepaid Metering And Net Metering ( E ) Exceptions:I ) Capture And Log Data Exceptions, Problems And Failures And Send Emails / Sms.Ii ) Generate Exceptions Fora ) Meter Tamper Alertsb ) Communication Module Health Alertsc ) Communication Is Less / More Than Pre-Defined Average Consumptiond ) Negative Consumptione ) Power Outagef ) Demand / Loadg ) Renewable Energy / Ev ( F ) Customer Services:I ) Access To Current And Historical Consumption And Interval Data, Outage Flags, Voltage And Power Quality Indications.Ii ) Email / Sms Notification Of Configured Alarms And Events To Selected Users.Iii ) Web Portal To Provide The Consumer Near Real Time Online Views Of Usage And Cost, Alerts And Notifications And Mobile App. 101 Contd From Boq Item No. 97, 98 , 99 & 100 ( G ) Analysis:I ) Consumption / Load Profiles.A ) Configurable Period ( Hours, Day, Month, Year Etc ) B ) Day Type ( Weekend, Holiday , Festival Wise Etc ) C ) Tariff, Customer Type, Or Any User Specified Collection Of Meters.Ii ) Peak And Off Peak Load Patterns By Aggregating All Loads Of Dt / Feeder / Consumer Group.Iii ) Dt / Feeder Wise Energy Audit.Iv ) Load Forecasting, Load Research.V ) Ability To Configure The System To Effectively Visualise Consumption Trends, Identify Unusual Patterns, And Visualise Load Analysis To Understand Which Assets Are Being Over Utilised. ( Vi ) Analysing Tamper Event Data. ( H ) Reporting:I ) Daily Data Collection Report.Ii ) Usage Exceptionsiii ) Vee Validations Failures.Iv ) Physical Meter Events ( Install, Remove, Connect, Disconnect ) And Meter Resent Report.V ) Meter Flags.Vi ) Meter Inventory.Vii ) Defective Meters.Viii ) Interface Exception Reports Between Mdm And Other Subsystems Eg. Billing, Outage Etc. 102 Desgign, Testing, Commissioning And Integration Of Different Devices Of Different Makes / Equipment / Software As Per Functional Requirements Including Water Charges, Furiture Charges And License Fee.Software Note: ( A ) The Software Would Be Hosted Either On Gcc Server Or On Nic Server. ( B ) The Software Would Contain Two Year Defect Liability. ( C ) Rates Deemed To Include All Operating Expenses Such As Gprs Charges, Hosting Charges Etc. ( D ) Geshall Provide Public Fund Account Details And Contractor Shall Be Responsible For Necessary Arrangement ( Tri Partite ) With Mes And Payment Gateway Integrator ) . ( E ) The Software Would Be Scalable And Expandable For Meters And System Of Different Make Complying With Is16444. The Software Would Be Able To Consumer Web Services Of The Future Projects If Rrequired. ( F ) The Software Would Enable The Features Of Refund Calculation In Case Of Quarter Vacation. ( G ) The Software Sample Approval Would Be Based In Integration Demontstraining Of At Least Four Makes Of The Meters ( 2 Rf At Least And 2 Cellular At Least ) ( H ) The Software Would Support Other Charges Such As Water Charges, Lices Fee, Furniture Charges And Other Allied Charges. ( I ) The Software Would Allow Supporting Both Prepaid And Postpaid Billing Plans. Separate Groups Can Be Created For The Same. 103 Contd From Boq Item No. 102.Note:I ) Cyber Audit: Audit Of Software For Smart Meters Will Be Done By Cert-India Empanelled Firm / Cert Auditor Of Armed Forces. The Cost Of Audit Shall Be Borne By The Contractor.Ii ) Cyber Security: The Following Guidelines / Strategies Shall Be Taken Care Of By The Amisp / Contractor For Making The Entire Ami System Including The Service Provider Immune To Cyber Attacks:A ) All The Hardware, Od And Application Software Shall Be Hardened.B ) Application, Scanning And Hardware Scanning Tools Shall Be Provided To Identify Vulnerability And Security Threats.C ) Data Shall Be Encrypted At System / Device / Technology Level.D ) While Procuring Cyber Security Items Testing Must Be Done And The System Must Be Secure By Design.E ) Residual Information Risk Shall Be Calculated By Contractor And Same Shall Be Submitted For Perusal Of Cyber Audit Teams.F ) Penetration And Vulnerability Assesment Test From Certified Auditors During Feild Acceptance Test ( Fat ) Site Acceptance Test ( Sat ) ( 122 Meter ) And Operation And Maintenance Period. 104 Hosting The System To Government Community Cloud In Place Of Server For Hosting And Management Of Supplied Software Application With Standby Server Comprising All As Specified Having Minimum Items / Specification As Under:- 105 Hosting The Web Based Software Gcc Location Cloud Note: The Gcc Location Would Be As Per The Approved Meity List. In Case A Csp Is Removed From The Panel, The Contractor Would Migrate To A New Supplier. 106 Supply Of Vending Station Desktop With Configuration Of I5, 8 Gb Ram, 1 Tb Hard Disk, 21.5 Monitor, Windows 10 / 11, Ms Office, Wireless Keyboard And Mouse, Cd Rom Read / Write, Usb Ports Including Video Card, Etc. Note ( 1 ) Internet Connection Shall Be Provided In The Name Of The Department, Charges Shall Be Borne By The Contractor. 107 Supply And Fixing Ups With Following Specifications Complete All As Specified And Directed By The Engr-In-Charge: ( A ) Capacity 1000 / 1200 Va Without Output Voltage 230 V Ac +10% Of Frequency 50 Hz + 1% ( B ) Min 30 Min Backup With Full Battery Condition ( C ) Battery Warranty Of At Least 2 Years. 108 Supply And Fixing Of Laser Jet Printer With Single Function Black And White With Usb Connection With Printing Speed Of Min 18 Pages Per Minute With Resolution Of 600 X 600 X 2Dpi Complete All As Specified And Directed By The Engr-In-Charge 109 General Note:Certain DoS And DontS Have To Be Strictly Implemented To Ensure Privacy And Security Of Consumers For Amc Of Smart Metering:DoS:A ) User Id Must Not Reveal Identity And Loactions.B ) User Id To Be Kept In Confidentiality By Competent Authority Mantaining The Overall System.C ) Any Breach Of Information From Server / Cloud Should Immidiately Be Reported To Local Military Authority.D ) Sys Logs By Installing Siem Log Collectors Should Be In Place To Mantain Records.E ) Regular Change Of Passwords In Imperative System Driven Periodic Change Of Passwords To Be Ab-Initio Built Into The Application.DontS:A ) No Personal Identifiable Information ( Piis ) To Be Used In The System.B ) Tampering Of Meter.C ) Disclosure Of Information Of Consumer To Anybody Other Than The Consumer.D ) Access To Servers By Only Authorised Person. 110 ( Comprehensive Operation Work During Defects Liability Period ) :Provision For Comprehensive Operation Including Routine Maintenance Including Repairs / Replacement Of Defective Meters / Dcu And Other Associated Components ( Software / Hardware ) Required To Make The System Alongwith All 122 Smart Meter Functional At All Times Including Periodic Charges Of Telecom Operator, Smart Meter Billing From Completion Of Work Till The Completion Of Defect Liability Period Of 2 Years. 111 Sch A Part-Ii ( Schedule Of Credit ) Note :- Amount Of Rs 32, 800.00Indicated In Tender Documents As Schedule Of Credit Shall Be Deducted From The Total Quoted Amount Of Boq.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 29-Apr-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 06-05-2024

Key Value

Document Fees
INR 2000 /-
EMD
INR 495000.0 /-
Tender Value
INR 4.20 Crore /-

Attachment

FileName File Description File Size
8f182a51-d978-4f7d-b730-4e583a4625c5.html Tender Notice 0 KB
BOQ_727940.xls Tender Document 0 KB
TENDER.pdf Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

Name of Work: IMPROVEMENT TO CERTAINSMQs/OMQAT AFS SALUA
Sl. No. Item Description
1Taking down cement plaster of any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water etc and removing the debries outside of MOD land, complete all as specified and directed.
2Demolition of un-reinforced cement concrete of any description and in any position not otherwise specifically provided for and disposal of unserviceable materials, debris and rubbish to a distance not exceeding 100 m, complete all as specified and directed.
3Cutting holes in brick walls built in cement mortar or cement lime mortar and stone walls for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or in cement concrete 1:2:4 type B-1 (20mm graded stone aggregate) exc half brick but not exc one brick thick,complete all as specified and as directed.
4Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and directed.
5Taking down chowkats or frame, n.exc 1.5 Sqm each with shutters (without taking off shutter from the frame) complete all as specified and directed.
6Demolition of stone slabs and tiles of any description or any thickness in floors, aprons etc laid, bedded and pointed in cement mortar complete all as specified and directed.
7Taking up or down GI tubing of 15mm bore and connections, including cleaning for refixing or removal to store, complete all as specified and directed.
8M&L brickwork with Fly ash bricks, straight or curved on plan exc6m mean radius built in cement mortar 1:6, complete all as specified and directed.
9M & L for rendering 15 mm thickon fair faces of brick work or concrete surfaces in cement mortar 1:4 and finished even and smooth without using extra cement, complete all as specified and directed.
10M & L for rendering 15 mm thickon other than fair faces of brick work or concrete surfaces in cement mortar 1:4 and finished even and smooth without using extra cement, complete all as specified and directed.
11Supply only liquid water proofing compound approved quality, complete all as specified and directed.
12M & L forPCC ( 1:2:4) Type B-0 (using 12.5mm graded stone aggregate) as in roof paddingincluding formwork, if required, complete all as specified and directed.
13M&L for non skidcoloured ceramic tiles 7 to 8 mm thick (square /rectangular) area of each tile exceeding 0.11 Sqm but n.exc 0.18 Sqm, in floors etc, set and jointed in neat cement slurry and pointed with white or coloured cement to match over and including 15mm thick screed bed of cement mortar 1:6, complete all as specified and directed.
14M&L for non skidcoloured ceramic tiles 7 to 8mm thick of approved shade and pattern(square /rectangular) area of each tile exceeding 0.18 Sqm but n.exc 0.38 Sqm, in floors etc, set and jointed in neat cement slurry and pointed with white or coloured cement to match over and including 20mm thick screed bed of cement mortar 1:6, complete all as specified and directed.
15M&L for non skidcoloured ceramic tiles 7 to 8mm thick of approved shade and pattern (square /rectangular) area of each tile exceeding 0.18 Sqm but n.exc 0.38 Sqm, as in skirting, dado, riser to steps etc,etc, set and jointed in neat cement slurry and pointed with white or coloured cement to match over and including 10mm thick rendering in cement mortar 1:4, complete all as specified and directed.
16M&L forglazed coloured ceramic tiles of size 350x250x7mm/450x300x7mm to 8mm thick in vertical surface set and jointed in neat cement slurry pointed with white or coloured cement to match over and including 10mm thick rendering incement plaster 1:4, complete all as specified and directed.
17M&L for scratch free dark shade vitrified ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed with white or coloured cement to match over and including 20mm thick screed bed of cement mortar 1:6, complete all as specified and directed.
18M&L for scratch free dark shade vitrified ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, as in skirting, dado, riser to steps etc, set and jointed in neat cement slurry and pointed with white or coloured cement to match over and including 10mm thick rendering in cement mortar 1:4, complete all as specified and directed.
19M&L for 18-20mm thick Granite (of any type) tiles machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete as in floor, cooking platforms and like complete over and including 15mm thick screed bed in cement mortar 1:6, complete all as specified and directed.
20M & L for PCC (1:2:4) , type B-1 (using 20 mm graded crushed stone aggregate) in in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands,plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including formwork if required ,upto a height of 10.00 mtr including necesasary scaffolding complete all as specified and as directed
21M & L for steel formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc (rough finished surfaces ) complete all as specified anddirected.
22M & L for steel form work to side of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batterfor rough finished surface of concrete in flat complete all as specified and directed.
23M & L for steel form work to sides of pillars, posts, struts, piers, columns and stanchions and similar work vertical or to batterfor rough finished surface of concrete in flat complete all as specified and directed.
24M&L Reinforced cement concrete M 25 (Design Mix) using20mm graded aggregate in Beams, cantilevers, bressummers, lintels over 1.5m span and the like complete all as specified and directed. (Note : Reinforcement and form work will be measured and paid separately under relevant items)
25M&L for RCC M-25 (Design Mix) (using 20mm graded crushed stone aggregate) as in foundations, including rafts, footings, foundation beams; etc; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. (Note : Reinforcement and form work will be measured and paid separately under relevant items)
26M&L Reinforced cement concrete M 25 (Design Mix) using20mm graded aggregate in columns, pillars, piers, posts and struts and the like complete all as specified and directed. (Note : Reinforcement and form work will be measured and paid separately under relevant items)
27S & F TMT steel bars 10 mm dia and over cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality complete all as specified and directed.
28S & F Mild steel TMT bars 5mm dia and over upto and including 10mm dia in strirrups, spacers and binders spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips etc complete all as specified and directed.
29M&L for PCC (1:4:8) type D-2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and as directed.
30Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, for lying of cable etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/dense soilcomplete all as specified and directed.
31Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, for lying of cable etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soilcomplete all as specified and directed.
32Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in hard/dense soil complete all as specified and as directed.
33Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and as directed.
34Removing excavated material(Soils) to a distance exc. 250m but not exceeding 1.5 KM including loading/unloading etc and depositing where directed at a level n exc. 1.5 m above the starting pointcomplete all as specified and as directed
35Removing excavated material(Soils) to a distancenot exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting pointcomplete all as specified and as directed
36M & Lfor sand cushioning foror filling under floor or in foundations or under ground cable with locally available sand for protection of cable including spreading and consolidations, complete all as specified and directed. (Note:- Thickness after consolidation be measured for payment)
37M & L for preparation of new plastered surfaces of wall and applying two coats of oil distemper emulsion(Ist quality) of approved manufacturer over a coat of priming paintover and including 2mm thick wall care puttycomplete all as specified and directed
38M & L forpreparation ofnewly plastered surfaces of wall and applying two coats ofcement base paint over a coat of alkali resistant primer , complete all as specified and directed.
39M & L forpreparation of old plastered surfaces of wall and applying two coats ofoil distemper emulsion (Ist quality) of approved manufacturerover a coat of primer paint, complete all as specified and directed.
40M & L forpreparation ofnewly plastered surfaces of wall and finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm over new surfaces, complete all as specified and directed.
41M & L for providing precast cement concrete louvres and jallies, 45mm thick (mea sured solid), including all mouldings but excluding frame, Type B-0 1:2:4 (12.5mm graded agg.) set in CM (1:4) of size 600x600mm , design as approved by GE complete all as specfied and as directed.
42S & F steel windows with side hung shutter including projecting type hinges as with steel handle, steel peg stay complete with glazing bars dovetailed or welded including double lead for glass and wiremesh complete all as specified and directed.
43S & F steel windows with side hung shutter including projecting type hinges as with steel handle, steel peg stay complete without glazing bars dovetailed or welded including double lead for glass and wiremesh complete all as specified and directed.
44S&F 3mm thick Sheet glass, ordinary quality and glazing in aluminium section in square not exc 0.5 sq. m in each pane complete all as specified and directed.
45S & FStainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, complete all as specified and directed.
46M & L for preparation of newor previously untreated steelor iron surfaces of any description over 10cm width or girthand applying two coats of synthetic enamel paint over a coat of red oxideprimer complete all as specified and directed.
47Taking down old roof treatment materials fromsurface of old concrete roof by picking, sweeping clean and washing down with water using wire brush brooming down, removal of unserviceable material obtained from demolition to a distance of n. exc 1000mbeyond the lead, including loading, unloading and stacking at the destination and applying the following treatment all as directed in order of precedence as stated :- (i)Rendering 15mm thick in CM (1:4) on existing roof surface true to level. ii) Applying one coat of industrial bitumen 85/25 @ 1.20 Kg/Sqm. (iii) Supply and laying 3mm thick APP based polymeric membrane of approved manufactured with weight not less than 3.60 Kgs per Sqm reinforced with non-woven polyester fabric/matt weighing not less than 160gms per Sqm having softening point not less than 150 mm centigrade, having tensile strength of 650 N/5cm and 350 N/5cm in longitudinal and transverse directions respectively of the reinfocred tearing strength of 180 N by torch application . Polymeric membrane shall be taken to a height of 30cm(minimum) and then inserted inside the groove of parapet wall and shall be finished by a membrane flashing. (iv)Applying one coat of aluminium paint over APP membrane.
48Item No 47 Contd....Note :- (i)Laying APP based polymeric membrane shall be done torch on method as per manufactures instructions. . (ii) A minimum overlap of 100mm and 75mm should be made at the endand sides of the polymeric membrane respectively and sealed alloverlaps and joints as per manufacturers instruction.(iii) APP based polymeric membrane shall beof any one of the approved makes as specified here-in-after and shall conform to specifications given in IS 16540-2017/IS 16532-2017.(iv)Contractor shallproduce necessary test certificate of the manufacturer to the Engr-in-Chage before incorporation in the work. (vi)Necessary independent tests shall also be carried out by the Contractor without any extra cost to the Deptt as per relevant IS specifications and membranes with satisfactory test results shall only be incorporated in the work(vii)The work shall be executed through authorised applicators of original manufacturer only(viii) Removal of surplus materials to a distance not exc 1000m beyond the lead is deemed to be included in the quoted rate of item.
49S&F GI tubing of 15mm dia medium grade with all fitting and fixed complete to walIs and ceilings or laid in floors complete all as specified and directed.
50S&F "in repairs "for15mm bore , fancy type chromium plated bib tap, cast copper alloy with capstan head long body and cup, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
51S&F " in repair "sinks with drainage board made of stainless steel1 mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm ,incl 40mm dia waste pipe of polythelene of low or high density, 40mm bore chromium plated brass waste fitting with long screwed shanks and fly nuts, flange end bedded in red lead cement & other end fixed, making holes in walls for brackets and fixed in CM (1:3) if required, complete all as specified and as directed.
52M & L for 60mm thick Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 , M-35 Grade, paver block coloured with grey cement and pigment laid over sand cushioning all as specified and directed. (Note : sand cushioning shall be measured and paid under respective item)
53M & L for50mm thick PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in sub base flooring including formwork, if required, complete all as specified and directed.
54M & L for surface excavation n exc 30 cm deep and averaging 15cm deep and getting out soft/loose soil , complete, all as specified and directed.
55M & Lfor hardcore of gauge n exc. 63 mm broken stone or boulders deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface , complete all as specified and directed
56S&F perforated Cutlery DrawerLength 500-550 mm, Depth- exc 490 mm , Height -90 mm made of stainless steel of Grade IS:202.includinggood quality telescopic channel set for movement ,if required, including necessary fixing arrangement to the kitchen cabinet/cupboard boardwith glue/nails/screw etc all as specified and directed.
57S&F Plain basket Drawer Length 500-550 mm, Depth- exc 500 mm , Height -100 mm made of stainless steel of Grade IS:202. ( allowable tolerance limit 20mm in dimension ) including good quality telescopic channel set for movement,if required, including necessary fixing arrangement to the kitchen cabinet/cupboard boardwith glue/nails/screw etc all as specified and directed.
58S&F Cup and saucer basket length 500-550 mm, Depth- exc 500 mm , Height -100 mm made of stainless steel of Grade IS:202. ( allowable tolerance limit 20mm in dimension ) including good quality telescopic channel set for movement,if required, including necessary fixing arrangement to the kitchen cabinet/cupboard boardwith glue/nails/screw etc all as specified and directed.
59S&F Thali basket Drawer Length 500-550 mm, Depth- exc 500 mm , Height -200 mm made of stainless steel of Grade IS:202. ( allowable tolerance limit 20mm in dimension ) including good quality telescopic channel set for movement,if required, including necessary fixing arrangement to the kitchen cabinet/cupboard boardwith glue/nails/screw etc all as specified and directed.
60S&F D-tray dia of tray 750 mm dia made of stainless steel of Grade IS:202. ( allowable tolerance limit 20mm in dimension ) including good quality telescopic channel set for movement,if required, including necessary fixing arrangement to the kitchen cabinet/cupboard boardwith glue/nails/screw etc all as specified and directed.
61S&F auto closing waste bin made of stainless steel of Grade IS:202. ( allowable tolerance limit 20mm in dimension ) including good quality telescopic channel set for movement,if required, including necessary fixing arrangement to the kitchen cabinet/cupboard boardwith glue/nails/screw etc all as specified and directed.
62S&F bottle pull out made of stainless steel of Grade IS:202. ( allowable tolerance limit 20mm in dimension ) including good quality telescopic channel set for movement,if required, including necessary fixing arrangement to the kitchen cabinet/cupboard boardwith glue/nails/screw etc all as specified and directed.
63S & Ffactory made ready to install Non-toxic, lead & cadmium free, single extruded, water proof, termite proof, fire retardant, excellent screw holding capacity, solid PVC boards 18mm thick , one side decorative choice lamination and other side balacing white as in cup board shutters fixed to door frame with and including continious (Piano) hinges, stainless steel , bright finish or electrogalvanised and width of flaps 40mm(when open) and stainless steel screws completeall as specified and directed.
64S & Ffactory made ready to install Non-toxic, lead & cadmium free, single extruded, water proof, termite proof, fire retardant, excellent screw holding capacity, solid PVC boards 18mm thick ofwhite colour in cup board shelves fixed to guide rails with stainless steel screws etc including all required accessory and builders hardware if required, completeall as specified and directed.
65S&F 35mm hinge with self-closing cup CC 48mm, clip on, 4 hole plate, hinge with arm cover for kitchen cabinet/cup board etc complete all as specified and as directed.
66S & F 125mm long stainless steel mirror finish modular kitchen cabinet handle complete all as specified and as directed.
67S & F 150mm long stainless steel mirror finish modular kitchen cabinet handle complete all as specified and as directed.
68S & F for brass knobs 35-40mm dia complete all as specified and as directed.
69S & F shelf support for kitchen shelves complete all as specified and as directed.
70S & F L-clip for kitchen shelves complete all as specified and as directed.
71Supply, Fixing and Installation of wall mounted Electric Kitchen Chimney of size 75cm, metal body,compact design havingsuction capacity not less than 1400 m3/hr Auto clean type touch control with wave sensor duct dia 150mm including free Kit for installation with duct cover of adequate size ,complete all as specified and as directed.
72M & L forconcealed sub main wiring with two single core PVC insulated unsheathed, multistranded flexible copper conductor 1100Volts grade, FRLSH type, cables 4 Sqmm drawn through in and including rigid PVC heavy duty concealed conduits medium grade not less than 20mm dia including 4 Sqmm 1100 Volts grade, FRLSH type, PVC insulated unsheathed multi stranded flexible copper conductor cable as continuous earth wire and connecting to common earth terminals complete all as specified and directed. Note:- (i)Two single cable for phase and neutral one single core green earth wire including one meter PVC conduit is measured as one unit. (ii)PVC conduit and its accessories is deemed to be included in this item rates. (iii) Unit rate include for cutting chases for conduits and sinking for boxes andmaking good to wall, floors etc.
73S & F vertical type wall mounted storage water heater of capacity 25 Ltrs BEE 5 Star rated or minimum Standing Loss of 0.511 kWh , 240V, 50Hz with Maximum power consumption of 2 KW , dry powder fero glass line coating technology for inner tank with incoloy heating element , ABS outer body , 2 Nos PVC connection pipe with length of 450 mm length for hot and cold water supply with complete Accessories complete all as specified and as directed.
74S & F Switch socket combination, 2 in 1, multipurpose, suitable for 6 pin, 5/ 6 Amp and 15/ 16 Amp flush type including connection complete all as specified and as directed.
75M & L for point wiring with 1.5 Sqmm FRLSH &PVC insulated unsheathed single core multi stranded copper conductor concealed type 1100 volt grade drawnin and includingnon-metalicPVCrigid conduit of minimum 20mm medium gradesize for one light/ fan point/ bell point controlled by one way switch including one 1.5Sqmm PVC insulated (green colour) unsheathedcopperconductorfor earth continuity conductor and connected to earth dolly and to be terminatedto newsunken /pressedflushmetalboxesof thickness 1.2mm coveredwith3mm thick hylum sheetasperrequirementatsiteformounting switches , sockets , fanregulatorsetcincludingtestingoncompleteallasspecifiedandasdirected. Note: - (i) Rate quoted shall include for cost of making MS box and concealed in wall including cutting and sinking of boxes and making good tothe walls (No extra payment will be made for the same) (ii) Provision of blank plates as per site requirement (No extra payment will be made for the same)
76M & L forconcealed sub main wiring with two single core PVC insulated unsheathed, multistranded flexible copper conductor 1100Volts grade, FRLSH type, cables 6 Sqmm drawn through in and including rigid PVC heavy duty concealed conduits medium grade not less than 20mm dia including 6 Sqmm 1100 Volts grade, FRLSH type, PVC insulated unsheathed multi stranded flexible copper conductor cable as continuous earth wire and connecting to common earth terminalsincluding taking down of old wiringcomplete all as specified and directed. Note:- (i)Two single cable for phase and neutral one single core green earth wire including one meter PVC conduit is measured as one unit. (ii)PVC conduit and its accessories is deemed to be included in this item rates. (iii) Unit rate include for cutting chases for conduits and sinking for boxes andmaking good to wall, floors etc.
77S & F copper wound exhaust fan, steel bodymade of sturdy Engineering plastic with louvers shutter, AC single Phase 230V of size 250mm sweep with, blades, complete with mounting arrangment as per site requirementand connecting wire up to nearest ceiling rose in flexible PVC pipe complete all as specified and directed.
78S & F switch piano flush type, single pole, one way, 5/6 Amp, 230 volts complete all as specified and directed.
79S&F ceiling rose, 3 phase, phase/polycarbonate, isolated body,complete all as specified and directed.
80Material & Labour Earthing complete withgalvanised steel earth plate electrode 60cmx60cmx6 mm thickness burried directly in ground (earth pit not less than 2.25mtr deep below normal ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level connected to and incl galvanised earth lead wire of 4.00mm dia by means of nuts & bolts, check nuts and washers of galvanised incl PCC pit of 1:2:4 type B-1, cover reinforced with XPMweightnot less than 4 Kg/Sqm and 6mm dia bar handle, earth pit angle iron frame of size 25mm x 25mm,excavation and earth work in anytype of soil, charcoal dust, salt, medium grade GI watering pipe 20mm dia with funnel and wire mesh and light grade GI protection pipe of 40mm bore from top edge of earth plate upto main distribution board complete allto as shown in electrical plate No 3 of MES Sch 2009 (Part I) connected main switch board all as specified and testing on completion, including disposal of surplus soil to a distance not exceeding 50m , complete all as specified and as directed. [Note : (a)The unit rate includes for protection pipe and earth lead upto 7.5 m. Any variation in length of earth leas and protection pipe beyond 7.5 m shall be measured and paid seperately. (b)Excavation/earthwork is deemed to be included in the quoted rate.]
81Supply and laying 50mm bore GI Pipe (light grade)with all fittings laid in trenches complete all as specified and as directed.
82Supply and laying 80mm bore GI Pipe (light grade)with all fittings laid in trenches complete all as specified and as directed.
83Supply, laying and testingLT cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured electric power cable( heavy duty ) stranded aluminium conductor 1100 volt grade of size 95 sqmm, 3.5 core complete all as specified and directed.
84Supply, laying and testingLT cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured electric power cable( heavy duty ) stranded aluminium conductor 1100 volt grade of size 70 sqmm, 3.5 core complete all as specified and directed.
85Supply, laying and testingLT cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured electric power cable( heavy duty ) stranded aluminium conductor 1100 volt grade of size 35 sqmm, 3.5 core complete all as specified and directed.
86Supply, laying and testingLT cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured electric power cable( heavy duty ) stranded aluminium conductor 1100 volt grade of size 25 sqmm, 4 core complete all as specified and directed.
87M & L for manual boring under road and foot path for inserting 40/50/80mm bore GI tubing for drawing UG cable, removal of soil etc complete all as specified and directed.
88Supply, layingin trenches burnt bricks old size of 230 x 115 x 75mm Fly ash bricks for cable protectioncomplete all as specified and directed.
89M & L for fabricating,Installation, Testing and Commissioning of LT Bus bar Feeder Pillar box outdoor type having provision of double door opening into two halves with rubber beadings cubical type of size 1.00 x 0.75 x 0.40 mtr as directed, made out of 3.15mm CRCA sheet compartmentalised with rubber beadings, angle iron 40 x 40 x 5mm shall be used for making lugs/frame , duly painted with powder coated internally and externally, including aluminium bus bar 375 Amps, and suitable cable glands of required size as per site requirement of LT cable entry including foundation work as required at site and comprising following:- (a) Incoming- MCCB 4 Pole 415 Volts adjatable thermal and fixed magnetic settingIcu= 100% Ics type of capacity 250 Amps, 25 kA breaking capacity-01 Nos (b) Outgoing (i) MCCB 3 Pole 415 Volts adjatable thermal and fixed magnetic settingIcu= 100% Ics type of capacity 100 Amps, 16 kA breaking capacity-03 Nos (ii) MCCB 3 Pole 415 Volts adjatable thermal and fixed magnetic settingIcu= 100% Ics type of capacity 63 Amps, 16 kA breaking capacity-04 Nos (c)LED Indicating lamps for Main Supplyindicating R", Y" B"- 01 Set of 3 (d)VIF Digital meter with suitable CTs for Ampere and Voltage display Note (i) Pre-dispatch inspection at OEM/factory premise shall be carried out by Rep of Accepting Officer. (ii) Prior to manufacture, the contractor shall get the GA drg approved from Accepting Officer. (iii) After installation of transformer at site, the pre-commissioning test shall be carried out by SEI/EI. (iv)The rate quoted shall be inclusive of disconnection of all existing electrical connections and reconnecting with the new panel with new Thimbles and nut bolts, washers etc and taking out of old unserviceable panels as directed by Engineer-in Charge.
90M & L for fabricating/cutting/welding, Installation, Testing and Commissioning of LT Bus bar Feeder Pillar box outdoor type having provision of double door opening into two halves with rubber beadings cubical type of size 1.00 x 0.75 x 0.40 mtr as directed, made out of 3.15mm CRCA sheet compartmentalised with rubber beadings, angle iron 40 x 40 x 5mm shall be used for making lugs/frame , duly painted with powder coated internally and externally, including aluminium bus bar 200 Amps, and suitable cable glands of required size as per site requirement of LT cable entry including foundation work as required at site and comprising of MCCB 100 Amps, 3 Pole -01 No as incomer and MCCB32 Amps, 16 kA breaking capacity -04 Nos as outgoing and suitable insulators complete all as specified and as directed.
91Supply, installation , testing, commissioning, integration and maintaining the Advance Metering infrastructure (AMI) of smart meters of different makes having valid BIS certification mark with specific CM/L number (not more than 33% of particular make) to ensure interchangeability at later date using communication technology including GPRS/RF/Hybrid (RF + cellular) as per CEA/TRAI regulations in order to achieve overall economy in operation and maintenance . The AMI software and associated infrastructure should be capable of handling atleast 500 Nos of meters in the present phase of work of different makes having valid BIS licence with BIS:16444 with expansion capacity upto 1500 Nos of meters (during further phases of smart meters work)without any additional infrastructure and cost implication (except RF/GPRS meters, DCU and software as the case may be), including training and knowledge transfer, all expenditure incl periodic charges of telecom operator from installation till date of physical completion, obtaining audit of software for smart meters by CERT-India empanelled firms / CERT Auditor of Armed Forces, comprising all as specified having minimum parameters / specification as under:-
92Smart RF/Cellular/Hybrid (RF+Cellular) Single Phase AC Meter Tamper Proof, Static Meter of Class 1.0, 315 V, 50 Hz, 10 A-60 A having valid BIS licence of IS-16444 and relevant IEC standards with inbuilt Radio Frequency communication facilitywith self healing mesh network with default and on demand display, billing data generation facility, anti-tamper features, Microprocessor and LED/LCD based circuitry including SMC Meter Box of minimum size 250 X 250 X 160 mm or as suitable for 1 Phase meter with viewing glass, concealed hinge and earth bolt plugged complete all as specified and directed. Meter Should support sending the following data : 15 min instantaneous data for voltage, current, power factor, power, cumulative energy and frequency, monthly billing survey for Cumulative Energy and Max Demand to software Meter should have connect / disconnect functionality operable from mdm/billing software and prepaid features would be MDM / Billing end as per prevalent IS . The communication system shall support: (a) On demand energy transfer (b) Two way communication with DCU/HES (c) Clock Synchronisation facility with HES (Head End System) (d) Communication including different makes of meter shall be such that it should communicate with same DCU directly or via Mesh Network. (e) Meter Protocol shall be open interface system in accordance of transmission control protocol/internet protocol. (f) The cost of the meter would include 2 years recurring sim charges during the defect liability period. (g) The contractor shall keep sufficient No of smart meter in reserve for immediate replacement in for faulty meters to ensure zero downtime.
93Contd from BOQ Item No. 92 Notes: (a) The contractor would be responsible from removing the existing meter, noting down the reading and depositing it with the MES. (b) It would be possible to run the meter in both prepaid and postpaid mode (c) The meters would carry 5 year warranty. (d) The OEM would need to share the Authentication / Encryption keys of the meters along with relevant protocol details with the department. The department would need complete support of the OEM to be able to integrate the meter with any software of the department choice.
94Supply / Planning / Setup/Tuning of RF/GPRS/Hybrid (RF+GPRS) Communication infrastructure including the Network Management and Headend for the project the IP-67 protection Data Concentrator Units (DCU) compatible for remote Automatic Metering Infrastructure (AMI) solution and capable of communicating with the smart energy Meter in the corresponding frequency band and with the data server through GPRS/Ethernet. It would have internal memory to store data of at least 200 modules. It would have inbuilt battery back-up. It would have IP-67 protection. It would support auto discovery of the meters and self healing mechanism for the breaks in the RF network.It would have the following minimum features: (1) It shall be able to configure the communication with underlying nodes / meters (2) It should be able to pull data at conifigurable frequency from the nodes / meters. It shall be able to prioritise control commands. (3) DCU would support on demand data from nodes. (4) DCU would support data transfer via cellular / optical fibre communication. In case of cellular communication, it would support dynamic IP sim from any telecom service provider (minimum 5G/4G and fallback to 3G/2G) working in the location. (5) DCU would be able to communicate to the nearest meters directly. For farther meters, it would allow communication through exisiting meters via mesh or other formation (repeater meters etc). (6) DCU would allow more than one make of meters for the communication. (7) Quoted rates deemed to include for hosting and GPRS charges/communication charges/broadband charges for minimum 2 years of defect liability period after completion.(Make : Elmeasure/Secure/Schneider/Cyan Cannode as per bearing IS No IS-16444)
95Contd from BOQ Item No. 94 One Lot of HES (Head End System) / Gateway as per design shall be capable of meter data acquisition at user selected period, mantain time synchronism with smart energy /water meter and mantain communication device status and will provide visual interface to view the data/events with following features: (a) Remote smart meter data reading at configurable intervals (upto 1500 meters) (b) Acquisition of meter data on demand. (c) Two way communication with meter/DCU/MDMS. (d) Command for connect and disconnect the smart meter. (e) Audit report and event alarm logging. (f) Encryption of data for source communication. (g) Mantain time sync with DCU/meter. (h) Store raw data for duration of one week. (j) Setting of smart meter configurable parameter. (k) Communication device status and history. (l) Critical and non critical meter event like temer/power failure etc.
96Supply and Installation of single phase meter as repeaters complete all as specified and as directed.
97Supply and Setup of Meter Data Management (MDM) system including supply and configuration of the Web based Software with following modules: (i) Meter Data Management Module The meter data management module would be deemed for collecting the data from the meter to DCU and server and vice versa, make the data available in bidirectional mode ton the currency recharge, online payment gateway, post paid billing modules, scheduling maintenance, low balance warning, quarter wise KVA allocation/tripping, tariff regulations, software customisations etc all as directed by the Engr-in-Charge. (ii) Secure Mobile App/PC Based/Swipe Machine/Online Payment Gateway/all UPI platform for all users assigned by the BSO/GE (a) 15 min instantenous data from all the meters for minimum seven parameters- Cumulative Energy, Power, Current, Voltage, Power Factor and Frequency. (b) Abstract Download for Monthly and quarterly billing survey data for cumulative energy and max demand and tampering features. (iii) Billing Module: The billing module capable to create data sheet for currency recharges, recharge history, maximum demand individually, user complaint registers, cheque/payment reconcillations, fixed charges, energy bill details etc. (iv) Occupation and Vacation Module: Provision to enter admin controls for transfers/vacations. The system would support occupation/ vacation based on the unit categories. The system would support automatic data capture on occupation and vacation events. (v) Customer Module: The system would include a customer portal for the resident /occupant to log in and view their own energy / billing data. There would be android and iOS mobile apps for the user to monitor its own data and balance on regular basis.
98Contd from BOQ Item No. 97.. (vi) Energy Accounting Module The system would include features of energy accounting. The system would be able to account for total energy block wise, facility wise and would also allow calculations of unaccounted energy in case tally with incomer EB energy meter. (vii) Communication Module The system would provide communication of energy data and bills via print, email and sms methods. (viii) Meter Master Data: The system would support meter master data repository. The system would support meter replacement process. (ix) Excel Export:The system would support export of metering and billing data in excel format. (x)Customer Care Module - the software would include a customer care module where the user would be log in any complaints. The service provider would monitor the complaints and carry out the necessary activities for the complaints resolution. (xi) Meter Installation Module - The software would include an app based meter installation module where the meter installation or changes can be captured on the app itself and the readings may be demonstrated to the user if required on the app itself. (xii) Activities Communication - The software support communication of the various activities such as occupation, vacation, meter change. personal detail change etc. with the user as well as the department on email. (Make for MDMS : Elmeasure/Secure/HPL or any techno commercially equivalent make approved by GE and Make for Customer Care Solutions Module- Schneider/Innologix/SAP orany techno commercially equivalent make approved by GE )
99Contd from BOQ Item No. 97 & 98... Notes: The additional functional requirements of MDMS are as follows: (a) Asset Management: i) Meter Location (Apartment, shop, industry/address etc). ii) Consumer Information (Name, Account, ID etc) iii) Meter details (Meter No. 1 phase/3 phase, with or without relay etc). iv) Meter Configuration (Demand integration period, load profile capture period etc). v) GIS information (connection, feeder/transformer/pole etc) b) Meter data: i) Accept meter data from HES process, store 1500 meter data at least for 6 month and analyze. ii) Schedule and on demand meter reads and pinging of meter. iii) Storage of all connected meter events and alarm. (storing of 5 years data or more via archiving) iv) Provide complete history and audit trail for all data for 30 days (configurable period) v) Handle net metering/meters at the same premises. vi) Manage at a minimum 15 mint interval data. (c) Data validation, Estimation and Editing (VEE): i) Registered Read Data: Daily Billiing Cycle, as well as derived billing determinants like TOU. ii) Interval Data: Variable intervals and variable units of measure. iii) Calculated Data: Derived or computed such as determinants billing and aggregated loads. iv) Event Data: Event and alarm data from meters, network equipment and MDMS itself.
100Contd from BOQ Item No. 97,98 & 99 (d) Billing Determinants: i) Configuration multiple TOU/TOD options by customer type, day type (Weekend, Weekdays, and holidays) and by season. ii) Processing of interval data into billing determinants. a) Total consumption b) Consumption in different time blocks for TOU billing. c) Maximum demand (KW and KVA) d) Number of tamper counts e) Average power factor f) Ability for check metering, sub metering prepaid metering and net metering (e) Exceptions: i) Capture and log data exceptions, problems and failures and send emails/SMS. Ii) Generate exceptions for a) Meter tamper alerts b) Communication module health alerts c) Communication is less/more than pre-defined average consumption d) Negative consumption e) Power Outage f) Demand/Load g) Renewable Energy/EV (f) Customer Services: i) Access to current and historical consumption and interval data, outage flags, voltage and power quality indications. ii) Email/SMS notification of configured alarms and events to selected users. iii) Web portal to provide the consumer near real time online views of Usage and Cost, Alerts and Notifications and Mobile App.
101Contd from BOQ Item No. 97,98 ,99 & 100 (g) Analysis: i) Consumption/load profiles. a) Configurable period (hours, day, month, year etc) b) Day type (Weekend, holiday , festival wise etc) c) Tariff, customer type, or any user specified collection of meters. ii) Peak and off peak load patterns by aggregating all loads of DT/Feeder/consumer group. iii) DT/feeder wise energy audit. iv) Load forecasting, load research. v) Ability to configure the system to effectively visualise consumption trends, identify unusual patterns, and visualise load analysis to understand which assets are being over utilised. (vi) Analysing tamper event data. (h) Reporting: i) Daily data collection report. ii) Usage exceptions iii) VEE validations failures. iv) Physical meter events (install, remove, connect, disconnect) and meter resent report. v) Meter flags. vi) Meter inventory. vii) Defective meters. viii) Interface exception reports between MDM and other subsystems eg. billing, outage etc.
102Desgign, testing, commissioning and integration of different devices of different makes/ equipment/software as per functional requirements including water charges, furiture charges and license fee.Software Note: (a) The software would be hosted either on GCC Server or on NIC Server. (b) The software would contain two year defect liability. (c)Rates deemed to include all operating expenses such as GPRS charges, hosting charges etc. (d) GEshall provide Public Fund account details and contractor shall be responsible for necessary arrangement (Tri Partite) with MES and payment gateway integrator). (e) The software would be scalable and expandable for meters and system of different make complying with IS16444. The software would be able to consumer web services of the future projects if rrequired. (f) The software would enable the features of refund calculation in case of quarter vacation. (g) The software sample approval would be based in integration demontstraining of at least four makes of the meters (2 RF at least and 2 cellular at least) (h) The software would support other charges such as water charges, lices fee, furniture charges and other allied charges. (i) The software would allow supporting both prepaid and postpaid billing plans. Separate groups can be created for the same.
103Contd from BOQ Item No. 102. Note: i) Cyber Audit: Audit of Software for Smart Meters will be done by CERT-India Empanelled firm/CERT Auditor of Armed Forces. The cost of Audit shall be borne by the contractor. ii) Cyber Security: The following guidelines/strategies shall be taken care of by the AMISP/Contractor for making the entire AMI system including the service provider immune to Cyber Attacks: a) All the hardware, OD and application software shall be hardened. b) Application, scanning and hardware scanning tools shall be provided to identify vulnerability and security threats. c) Data shall be encrypted at system/device/technology level. d) While procuring cyber security items testing must be done and the system must be secure by design. e) Residual information risk shall be calculated by Contractor and same shall be submitted for perusal of Cyber Audit Teams. f) Penetration and vulnerability assesment test from Certified auditors during feild acceptance test (FAT) site acceptance test (SAT) (122 Meter ) and Operation and Maintenance period.
104Hosting the system to Government Community Cloud in place of server for hosting and management of Supplied Software application with standby server comprising all as specified having minimum items / specification as under:-
105Hosting the web based software GCC location cloud Note: The GCC location would be as per the approved MEITY list. In case a CSP is removed from the panel, the contractor would migrate to a new supplier.
106Supply of vending station desktop with configuration of i5, 8 GB RAM, 1 TB Hard disk, 21.5 " monitor, Windows 10/11, MS office, wireless keyboard and mouse, CD ROM Read/Write, USB ports including video card, etc. Note (1)internet connection shall be provided in the name of the department, charges shall be borne by the Contractor.
107Supply and fixing UPS with following specifications complete all as specified and directed by the Engr-in-Charge: (a) Capacity 1000/1200 VA without output voltage 230 V AC +10% of frequency 50 Hz + 1% (b) Min 30 min backup with full battery condition (c) Battery warranty of at least 2 years.
108Supply and fixing of laser jet printer with single function black and white with USB connection with printing speed of min 18 pages per minute with resolution of 600 X 600 X 2DPI complete all as specified and directed by the Engr-in-Charge
109General Note: Certain DO"s and DONT"s have to be strictly implemented to ensure Privacy and Security of Consumers for AMC of Smart Metering: DO"s: A) User ID must not reveal identity and loactions. B) User ID to be kept in confidentiality by Competent Authority mantaining the overall system. C) Any breach of information from Server/Cloud should Immidiately be reported to Local Military Authority. D) Sys Logs by Installing SIEM log collectors should be in place to mantain records. E) Regular Change of passwords in Imperative System driven periodic change of passwords to be ab-initio built into the application. DONT"s: A) No personal identifiable information (PIIs) to be used in the system. B) Tampering of Meter. C) Disclosure of information of consumer to anybody other than the consumer. D) Access to servers by only authorised person.
110(COMPREHENSIVE OPERATION WORK DURING DEFECTS LIABILITY PERIOD): Provision for comprehensive operation including routine maintenance including repairs/replacement of defective meters/DCU and other associated components (software/hardware) required to make the system alongwith all 122 Smart Meter functional at all times including periodic charges of telecom operator, smart meter billing from completion of work till the completion of defect liability period of 2 years.
111Sch "A" Part-II (SCHEDULE OF CREDIT) Note :- Amount of Rs 32,800.00indicated in Tender Documents as Schedule of Credit shall be deducted from the total quoted amount of BOQ.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail