Indian Institute Of Management-IIMA has published Tender For Repair Replacement Of Main Gate Shutter At Paschim Vihar Post Office New Delhi. Submission Date for this Tender is 07-05-2024. Gates Supply Tenders in lucknow Uttar Pradesh. Bidders can get complete Tender details and download the document.
FileName | File Description | File Size |
f0d3a888-cef4-4d9b-9270-55e6b8bab8ed.html | Tender Notice | 0 KB |
Amcpaintingtender2024.pdf | Tender Document | 0 KB |
BOQ_845101.xls | Tender Document | 0 KB |
Tendernotice_1.pdf | Tender Document | 0 KB |
Sl. No. | Item Description |
1 | Preparing the surface properly by scrapping/ rubbing with sand paper to remove the grease/ oily/ chipped/ powdered/ peeling/ fungus/ algae etc. Applying suitable Putty so as to adhere to the old painted / cemented surface. Again rubbing the surface with sand paper so as to get a smooth and even surface. Then applying suitable primer which can adhere to the putty/ old paint/ cement and the new paint (to be Applied) in required no. of coats. Again rubbing with sand paper to get the even and smooth surface and Then applying any of the following Paint in required no of Coats so as to get smooth even and uniform color finish over the wall. Each and every stage is required to be inspected by the concerned engineer/ officer and photographed before applying the other stage. |
2 | White washing with lime to give an even shade : New work (three or more coats) |
3 | Colour washing such as green, blue or buff to give an even shade : |
4 | New work (two or more coats) with a base coat of white washing with lime |
5 | New work (two or more coats) with a base coat of whiting |
6 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour :New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre |
7 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour Old work (one or more coats) |
8 | EXTERIOR FINISHING |
9 | Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm) |
10 | Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm |
11 | Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) |
12 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) |
13 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr/10 sqm |
14 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture |
15 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture |
16 | Finishing walls with ready mixed Premium acrylic emulsion paint (Company Depot Tinted) having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade with silicon additives. New work (Two or more coats applied @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm. |
17 | Applying priming coat: |
18 | With ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood |
19 | With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works |
20 | With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel work (second coat) |
21 | Painting with silicon & acrylic emulsion based water thinnable sealer of approved brand and manufacture on wet or patchy portion of plastered surfaces : |
22 | One coat |
23 | Two coats |
24 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer’s specifications including appropriate priming coat, preparation of surface, etc. complete. |
25 | On steel work |
26 | On concrete work |
27 | Painting on G.S. sheet with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : New work (two or more coats) including a coat of approved steel primer but excluding a coat of mordant solution |
28 | Applying a coat of mordant solution on G.S. sheet: |
29 | With a solution of 38 gms of copper acetate in a litre of soft water |
30 | With a solution made of 13 gms of hydrochloric acid in a solution of 13 gms each of copper chloride, copper nitrate and ammonium chloride dissolved in a litre of soft water |
31 | Painting (two or more coats) on rain water, soil waste and vent pipes and fittings with black anticorrosive bitumastic paint of approved brand and manufacture, over and including a priming of ready mixed zinc chromate yellow primer on new work: |
32 | 100 mm diameter pipes |
33 | 150 mm diameter pipes |
34 | Painting (two or more coats) on rain water, soil waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour over a priming coat of approved steel primer on new work. |
35 | 100 mm diameter pipes |
36 | 150 mm diameter pipes |
37 | Painting with oil type wood preservative of approved brand and manufacture: New work (two or more coats) |
38 | Providing and applying two coats of fire retardant paint on cleaned wood / ply surface @ 3.5 sqm per litre per coat including preparation of base surface as per recommendations of manufacturer to make the surface fire retardant. |
39 | Coal tarring two coats on new work using 0.16 Litre and 0.12 litre coal tar per sqm in the first coat and second coat respectively. |
40 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
41 | Painting with aluminium paint of approved brand and manufacture to give an even shade .Two or more coats on new work |
42 | Painting with acid proof paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work |
43 | Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade : Two or more coats on new work |
44 | Varnishing with varnish of approved brand and manufacture : |
45 | Two or more coats of glue sizing with copal varnish over an under coat of flatting varnish |
46 | Two or more coats glue sizing with spar varnish or an under coat of flatting varnish |
47 | French spirit polishing : Two or more coats on new works including a coat of wood filler |
48 | Polishing on wood work with ready mixed wax polish of approved brand and manufacture : New work |
49 | Floor polishing on masonry or concrete floors with wax polish of approved brand and manufacture. |
50 | Lettering with black Japan paint of approved brand and manufacture |
51 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour Old work (one or more coats) |
52 | Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. |
53 | One or more coat |
54 | Two or more coats |
55 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. |
56 | One coat |
57 | Two coats |
58 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. |
59 | With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre |
60 | With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre |
61 | White washing with lime to give an even shade : |
62 | Old work (two or more coats) |
63 | Old work (one or more coats) |
64 | Painting on G.S. sheet with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Old work (one or more coats) |
65 | Painting (two or more coats) on rain water, soil, waste and vent pipes and fittings with black anticorrosive bitumastic paint of approved brand and manufacture over and including a priming coat of ready mixed zinc chromate yellow primer on new work : 75 mm diameter pipes |
66 | Painting (one or more coats) on rain water, soil waste and vent pipes and fittings with black anticorrosive bitumastic paint of approved brand and manufacture on old work : |
67 | 75 mm diameter pipes |
68 | 100 mm diameter pipes |
69 | 150 mm diameter pipes |
70 | Painting (two or more coats) on rain water, soil waste and vent pipes and fittings with aluminium paint of approved brand and manufacture over a priming coat of ready mixed zinc chromate yellow primer on new work : |
71 | 75 mm diameter pipes |
72 | 100 mm diameter pipes |
73 | 150 mm diameter pipes |
74 | Painting (one or more coats) on rain water, soil waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour on old work : |
75 | 75 mm diameter pipes |
76 | 100 mm diameter pipes |
77 | 150 mm diameter pipes |
78 | Painting with oil type wood preservative of approved brand and manufacture: Old work (one or more coats) |
79 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : One or more coats on old work |
80 | Painting with aluminium paint of approved brand and manufacture to give an even shade: One or more coats on old work |
81 | Painting with acid proof paint of approved brand and manufacture of required colour to give an even shade : One or more coats on old work |
82 | Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade : One or more coats on old work |
83 | French spirit polishing : One or more coats on old work |
84 | Polishing on wood work with ready made wax polish of approved brand and manufacture :Old work |
85 | Re-lettering with black Japan paint of approved brand and manufacture |
86 | Painting (one or more coats) with black Japan paint of approved brand and manufacture to give an even shade |
87 | Finishing walls with water proofing cement paint of required shade |
88 | Old work (one or more coats applied @ 2.20 kg/10 sqm) over priming coat of primer applied @ 0.80 litrs/10 sqm complete including cost of Priming coat. |
89 | Old work (one or more coats @ 2.20 kg/10 sqm) complete. |
90 | Old work (Two or more coats on existing cement paint surface applied @ 3.28 ltr/10 sqm. |
91 | Old work (One or more coats) applied @ 1.82 ltr/10 sqm. |
92 | Finishing walls with Acrylic Smooth exterior paint of required shade : |
93 | Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface |
94 | Old work (One or more coat applied @ 0.90 ltr/10 sqm). |
95 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade |
96 | Old work (Two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface |
97 | Old work (one or more coats applied @ 0.83 ltr/10 sqm). |
98 | Varnishing with varnish of approved brand and manufacture |
99 | One or more coats with copal varnish |
100 | One or more coats with spar varnish |
101 | Melamine polishing on wood work (one or more coat). |
102 | Varnishing with flatting varnish of approved brand and manufacture one or more coats on old work. |
103 | Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos. 2.Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs. 3.On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs. 4.On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) |
104 | Providing and fixing double scaffolding system (cup lock type) on the exterior side of building/structure, upto 25 metre height, above ground level, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40 mm dia M.S. tube, placed 1.5 metre centre to centre, horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube challis, M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and/ or pointing and/ or applying chemical and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc,wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as perdirections and approval of Engineer-in-charge. Note:- (1) The elevational area of the scaffolding shall be measured forpayment purpose. (2) The payment will be made once only for execution of all items for such works. |
105 | Painting runway/taxi track/apron marking with adequate nos of coats to give uniform finish with road marking paint of superior make as approved by the Engineer-in-charge, including cleaning the surface of ail dirt, scales, oil, grease and other foreign material etc. and lining out complete. |
106 | New work (Two or more coats) |
107 | Old work (One or more coats) |
108 | Painting road surface marking with adequate nos of coats to give uniform finish with ready mixed road marking paint conforming to IS : 164, on bituminous surface in white/yellow shade, including cleaning the surface of all dirt, scales, oil, grease and foreign material etc. complete. |
109 | New work (Two or more coats) |
110 | Old work (One or more coats) |