}

Tender For Electrical Works On Orv Sagar Kanya => Limited, visakhapatnam-Andhra Pradesh

Hindustan Shipyard Limited has published Tender For Electrical Works On Orv Sagar Kanya => Limited. Submission Date for this Tender is 20-04-2024. Electrical Maintenance Tenders in visakhapatnam Andhra Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

43175308
Tender For Electrical Works On Orv Sagar Kanya => Limited
Limitted
NCB
Andhra Pradesh
Visakhapatnam
20-04-2024

Tender Details

Tender For Electrical Works On Orv Sagar Kanya-- 1 Magnetic CompassMagnetic compass calibration / deviation to be carried out during sea trials. Same to be proved and show to SS during sea trials/sailing.Qty - 01 No 2 Telephones1) Two new telephones are required in wet lab (stbd) and cabin no. 418. Lines also to be examined repaired for frequent connection issues in these two rooms.Qty - 02 Nos2) F-deck cabin 421 and 423 new phones are required. Conduit pipe of length 1m is required for the phone connection cable.Qty - 02 Nos3) F-deck cabin 418 phone connection and telephone required.Qty - 01 No4) Crew galley (2nd deck): one telephone in galley and one in the crew mess room with new cable connection required.Qty - 02 NosNote: Any Spares & consumables required are under vendor scope. 3 Air circuit breakers1) Following air circuit breakers to overhaul no volt trip overload trip reverse power trip short circuit to calibrate and test and breakers to be fitted in place and tested2) Alternators breakers:660v 1600amp stype: AEG ME 1600.Qty - 05 Nos3) Propulsion motors:660v 1600amps.Qty - 05 Nos 4) Tranformers:660v 630amps.Qty - 05 Nos5) Tranformers:390v 630amps.Qty - 01 No6) Non essential breaker: 390v 1000amps.Qty - 01 No7) Transfer line breaker: 390v630 amps.Qty - 01 No8) Bow thruster breaker: 660v 800amps.Qty - 01 No9) Azimuth thruster breakers:660v 800amps.Qty - 01 No10) Spare ACB in engine control room to be serviced.Qty - 01 NoNote: Any Spares & consumables required are under vendor scope. 4 Calibration of Meters1) CALIBRATION : Following meters on main switch board to be calibrated and certificates to be provided2) Double frequency meter 45 to 55hz.Qty - 05 Nos3) Double volt meters 0 to 800volts ac.Qty - 05 Nos4) Ammeters 0 to 3000amps ac.Qty - 05 Nos5) Kilowatt meters 0 to 1200kw.Qty - 05 Nos6) Following ammeters, voltmeters, pressure and temperature indicator in ECR console to be calibrated and certificates to be produced7) Voltmeters.Qty - 05 Nos8) Ammeters 0 to 3000amps AC.Qty - 05 Nos9) Pressure indicators.Qty - 05 Nos10) Temperature indicators.Qty - 04 Nos11) E Shaft tachometer of main electrical propulsion motors on bridge and ECR.Qty - 02 Nos12) The following electrical measuring instruments to be calibrated and certificates to be produced13) Multimeter:make: motwane dm 3540.Qty - 01 No14) Megger:make: meco 2853.Qty - 02 Nos15) Tong tester:make: kyroitsu 2805.Qty - 01 No 5 Various Meters in Engine room to be calibrated and certificate to be issuedNote : Scope of work is enclosed (4 pages). Qty - 01 LS1) Various Meters in Engine room to be calibrated and certificate to be issued, below are mentioned with full details. Some items are also mentioned at above.2) PANEL BOARD:BTRANGE/METER: AMMETER(0-4000) K OHMS 0-100 LOCATION: ECR.Qty - 01 No3) PANEL BOARD: TRANSFORMER 1 RANGE/METER: AMMETER 0-1500AMMETER/CT 0-600 LOCATION: ECR.Qty - 01 No4) PANEL BOARD: PM 1PORT FWD RANGE/METER: AMMETER 0-2000 AMMETER/CT 0-600 LOCATION: ECR.Qty - 01 No5) PANEL BOARD: PM 2 PORT AFT RANGE/METER: AMMETER 0-2000 AMMETER/CT 0-600 LOCATION: ECR.Qty - 01 No6) PANEL BOARD: DG#1RANGE/METER: AMMETER 0-3000, K WATT 120-0-1200,FREQUENCY MTR 45-55,DIF VOLT MTR 0-800 LOCATION: ECR.Qty - 01 No7) PANEL BOARD: DG#2RANGE/METER: AMMETER 0-3000, K WATT 120-0-1200, FREQUENCY MTR 45-55,DIF VOLT MTR 0-800 LOCATION: ECR.Qty - 01 No8) PANEL BOARD: DG#3RANGE/METER: AMMETER 0-3000, K WATT 120-0-1200, FREQUENCY MTR 45-55,DIF VOLT MTR 0-800 LOCATION: ECR.Qty - 01 No9) PANEL BOARD: DG#4RANGE/METER: AMMETER 0-3000, K WATT 120-0-1200, FREQUENCY MTR 45-55,DIF VOLT MTR 0-800 LOCATION: ECR.Qty - 01 No10) PANEL BOARD: DG#5RANGE/METER: AMMETER 0-3000, K WATT 120-0-1200, FREQUENCY MTR 45-55,DIF VOLT MTR 0-800 LOCATION: ECR.Qty - 01 No11) PANEL BOARD: PM#3 STBD FWD RANGE/METER: AMMETER 0-2000 AMMETER/CT 0-600 LOCATION: ECR.Qty - 01 No12) PANEL BOARD: PM#4 STBD AFT RANGE/METER: AMMETER 0-2000AMMETER/CT 0-600 LOCATION: ECR.Qty - 01 No13) PANEL BOARD: TRANSFORMER#2 RANGE/METER: AMMETER 0-1500 AMMETER/CT 0-600 LOCATION: ECR.Qty - 01 No14) PANEL BOARD: ATRANGE/METER: AMMETER 0-4000 LOCATION: ECR.Qty - 01 No15) PANEL BOARD: LIGHT CONSUMERS RANGE/METER: OHAM METER 10-0 LOCATION: ECR.Qty - 01 No16) PANEL BOARD: LIGHTING CONSUMERS RANGE/METER: VOLT METER 0-250 AMMETER 0-800 LOCATION: ECR.Qty - 01 No17) PANEL BOARD: ESSENTIAL CONSUMERS RANGE/METER: VOLTMETER 0-500 ,AMMETER 0-2400,DIF AMMETER 0-500 LOCATION: ECR.Qty - 01 No18) PANEL BOARD: ESSENTIAL CONSUMERS RANGE/METER: FREQUENCY METER 45- 55,AMMETER 0-1600K WATT METER -40-400,VOLT MTR 0-500 LOCATION: ECR.Qty - 01 No19) PANEL BOARD: ESSENTIAL CONSUMERS RANGE/METER: AMMETER 0-2400,VOLTMETER 0- 500,DIF AMMETER 0- 200 LOCATION: ECR.Qty - 01 No20) PANEL BOARD: NON ESSENTIAN CONSUMERS RANGE/METER: VOLTMETER 0-500 AMMETER 0-1600 LOCATION: ECR.Qty - 01 No21) PANEL BOARD: NON ESSENTIAN CONSUMERS RANGE/METER: OHAM METER 10-0 DIF AMMETER 0-300 LOCATION: ECR.Qty - 01 No22) PANEL BOARD: E1RANGE/METER: ARMATURE VOLTMETER 0-1 ARMATURE CURRENT 0-1 EXCITAION CURRENT 50-50 LOCATION: ECR.Qty - 01 No23) PANEL BOARD:E2RANGE/METER: ARMATURE VOLTMETER 0-1 ARMATURE CURRENT 0-1 EXCITAION CURRENT 50-50 LOCATION: ECR.Qty - 01 No24) PANEL BOARD:E3RANGE/METER: ARMATURE VOLTMETER 0-1 ARMATURE CURRENT 0-1 EXCITAION CURRENT 50-50 LOCATION: ECR.Qty - 01 No25) PANEL BOARD:E4RANGE/METER: ARMATURE VOLTMETER 0-1 ARMATURE CURRENT 0-1.Qty - 01 No26) EXCITAION CURRENT 50-50 LOCATION: ECR.Qty - 01 No27) PANEL BOARD: DC DB 24V RANGE/METER: VOLTMETER 0-30 AMMETER 0-100 LOCATION: ECR.Qty - 01 No28) PANEL BOARD: DB P11 FANS ENGING ROOM AFT RANGE/METER: AMMETER 0-100 4NOS LOCATION: ECR ENTRANCE.Qty - 01 No29) PANEL BOARD: DB-P3RANGE/METER: AMMETER 0-30 2NOS LOCATION: PURIFIER ROOM.Qty - 01 No30) PANEL BOARD: DB 07 RANGE/METER: VOLTMETER 0-50 AMMETER 0-75 LOCATION: TRANSFORMER ROOM.Qty - 01 No31) PANEL BOARD: M S W P/P FWD RANGE/METER: AMMETER 0-50 LOCATION: A/E ROOM.Qty - 01 No32) PANEL BOARD: DB P7 COOLING PUMPRANGE/METER: AMMETER 0-100 LOCATION: A/E ROOM.Qty - 03 Nos33) PANEL BOARD: DB P4RANGE/METER: AMMETER 0-100 LOCATION: A/E ROOM.Qty - 04 Nos34) PANEL BOARD: A/C SEA WATER COOLING P/P RANGE/METER: AMMETER 0-180 LOCATION: FERTILIZER ROOM.Qty - 01 No35) PANEL BOARD: A/C SEA WATER COOLING P/P RANGE/METER: AMMETER0-60 LOCATION: FERTILIZER ROOM.Qty - 02 Nos36) PANEL BOARD: FIRE&BILGE P/P RANGE/METER: AMMETER 0-100 .Qty - 03 Nos37) LOCATION: FERTILIZER ROOM.Qty - 01 No38) PANEL BOARD: EMG FIRE&BILGE P/P RANGE/METER: AMMETER 0-100 LOCATION: FERTILIZER ROOM.Qty - 01 No39) PANEL BOARD: HARBOUR SERVICE PUMP RANGE/METER: AMMETER 0-180 LOCATION: H/T CAMPARTMENT.Qty - 01 No40) PANEL BOARD: DB-P13 FANS ENG ROOM RANGE/METER: AMMETER 0-10 AMMETER 0-40AMMETER 0-200LOCATION: REFRIGERATION ROOM.Qty - 03 Nos41) PANEL BOARD: REFRIGERATION PLANTRANGE/METER: AMMETER 0-50 LOCATION: REFRIGERATION ROOM.Qty - 02 Nos42) PANEL BOARD: SCIENTIFIC COMPRESSERRANGE/METER: AMMETER 0-20 LOCATION: REFRIGERATION ROOM.Qty - 02 Nos43) PANEL BOARD: AC#1 RANGE/METER: AMMETER 0-1800 LOCATION: A/C ROOM.Qty - 01 No44) PANEL BOARD: AC#2,#3 RANGE/METER: AMMETER 0-500 LOCATION: A/C ROOM.Qty - 02 Nos45) PANEL BOARD: SCIENTIFIC EQE SUPPLY RANGE/METER: AMMETER 0-150 2NOS.Qty - 02 Nos46) AMMETER 0-400.Qty - 02 NOSAMMETER 0-150 LOCATION: CONVERTER ROOM.Qty - 02 Nos47) PANEL BOARD: SHORE CONNECTION BOX RANGE/METER: AMMETER 0-1600 LOCATION: NEAR CONVERTER ROOM.Qty - 01 No48) PANEL BOARD: STEERING PANEL 1 RANGE/METER: AMMETER 0-50 LOCATION: STEERING ROOM.Qty - 01 No49) PANEL BOARD: STEERING PANEL 2 RANGE/METER: AMMETER 0-80 LOCATION: STEERING ROOM.Qty - 01 No50) PANEL BOARD: EMNG FIRE PUMP RANGE/METER: AMMETER 0-300LOCATION: EMNG P/P ROOM.Qty - 01 No51) PANEL BOARD: AT PANELRANGE/METER: AMMETER 0-3000 LOCATION: AT ROOM.Qty - 01 NoE90 RPM meters for AE # 1, 2, 4 & 5 need to be renewed and made operational. The RPM meters are located on each generator.Qty - 04 Nos 6 Main Switch Board & Emergency Switch Board1) Main-switch-board & emcy switchboard to clean and-tight-all-the-terminals, insulation resistance of bus bars to check and record.Qty - 03 Nos2) 660 insultion meter showing less ohmic value during pm manoeuvring fault to be trace and rectify.Qty - 01 LS3) Insulation meter for 390 v panel and 220 v panel working condition need to be checked.Qty - 02 LS4) 230V & 390 V INSULATION METER NOT WORKING, SAME TO BE RECTIFIED IN MSB PANEL BOARD.Qty - 02 NosAll Spares / consumable which are required for complete service are under the scope of shipyard.5) AUDIBLE ALARMS IN PM ROOMNEED TO BE MADE OPERATIONAL.Qty - 01 No. Note: Any Spares & consumables required are under vendor scope. 7 1) Provision lift for galley Not in operation. Same to be made operational. Spares Vendor supply.Qty - 01 NoNote: Any Spares & consumables required are under vendor scope. 8 2) Wipers on bridge navigational glass to be renewed.Qty - 03 NosNote: Any Spares & consumables required are under vendor scope. 9 3) Ship`s laundry machine to repaired.Qty - 01 NoNote: Any Spares & consumables required are under vendor scope. 10 4) Testing board in Electrical workshop needs to be made operational.Qty - 01 NoNote: Any Spares & consumables required are under vendor scope. 11 5) ER lathe auto mode not working, to be made operational.Qty - 01 NoNote: Any Spares & consumables required are under vendor scope. 12 6) ER milling machine not working, to be repaired and made operational All the service / Spares and consumables in vendor scope Qty - 01 NoNote: Any Spares & consumables required are under vendor scope. 13 7) ER work shop drilling machine auto mode not working, to be made operational. Note: Any Spares & consumables required are under vendor scope. 14 8) Maintenance is needed for UV sterilizers and lamps need to be changed.Whenever the sterilizer is started, it shows lamp failure indication.Qty - 01 LSNote: Any Spares & consumables required are under vendor scope. 15 9) BATTERY CHARGER FOR ALDIS LAMP 0-10 AMPS ,7- 28 VOLT MAKE: DENKI ENG CO. BOMBAY. Not working, to be repaired or new one to be supplied.Qty - 01 NoNote: Any Spares & consumables required are under vendor scope. 16 ECR steering gearECR steering gear monitoring system not working, to be made operational. All the service / Spares and consumables in vendor scope.Qty - 01 No 17 Bow ThrusterBow Thruster Pitch Indicator fluctuates without command. PLC no3 and feedback unit needs to be checked and changed if required.Qty - 01 LSNote: Any Spares & consumables required are under vendor scope. 18 PROPELLER SHAFT EARTHING (MAKE:TWIFLEX,TYPE:NR 663079) MADE IT OPERATIONAL.Qty - 02 Nos 19 Domestic fridge compressor panel wire, components, terminals need to be renewed. Function test to be carried out to the satisfaction of ship staff. Spares/consumables required are under vendor scope. => Limited

Key Value

Document Fees
INR 525 /-
EMD
INR 30000.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail