Border Security Force-BSF has published Construction Of Sarv Dharm Sthal,Garrage &Pol Store,Electric Sub Station Pump Room &Generator Shed 02 Nos Central Morcha,04 Nos Corner Bunkers ,02 Nos, O2 Men Bunkers And Sentry Postat Bop Dangar Of 11Bn (Now 193Bn)Shq Bsf Shillong Ftr (Sh:Electrical Work. Submission Date for this Tender is 23-04-2024. Electrical Maintenance Tenders in East Khasi Hills Meghalaya. Bidders can get complete Tender details and download the document.




Tender Notice

43175295
Construction Of Sarv Dharm Sthal,Garrage &Pol Store,Electric Sub Station Pump Room &Generator Shed 02 Nos Central Morcha,04 Nos Corner Bunkers ,02 Nos, O2 Men Bunkers And Sentry Postat Bop Dangar Of 11Bn (Now 193Bn)Shq Bsf Shillong Ftr (Sh:Electrical Work
Open Tender
Indian
Meghalaya
East Khasi Hills
23-04-2024

Tender Details

Construction Of Sarv Dharm Sthal, Garrage &Pol Store, Electric Sub Station Pump Room &Generator Shed 02 Nos Central Morcha, 04 Nos Corner Bunkers , 02 Nos, O2 Men Bunkers And Sentry Postat Bop Dangar Of 11Bn ( Now 193Bn ) Shq Bsf Shillong Ftr ( Sh:Electrical Works )

Key Value

Document Fees
Refer document
EMD
INR 11214.0 /-
Tender Value
INR 5.60 Lakhs /-

BOQ Items

Name of Work: C/O SARV DHARM STHAL,GARRAGE &POL STORE,ELECTRIC SUB STATION PUMP ROOM &GENERATOR SHED 02 NOS CENTRAL MORCHA,04 NOS CORNER BUNKERS ,02 NOS, O2 MEN BUNKERS AND SENTRY POSTAT BOP DANGAR OF 11BN (Now 193Bn)SHQ BSF SHILLONG FTR (SH:ELECTRICAL WORKS)
Sl. No. Item Description
1Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.(Group-B)
2Wiring for circuit/ submain wiring alongwith earth wire with thesize 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
3Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required
43x1.5Sqmm
5Supplying and fixing of 20mmmedium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
6Wiring for power plugwith 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessedPVC conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
7Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing andcommissioning etc. as required.
8Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess i/c P/F 6 pin 5/6 & 15/16 amp modular socket out let and 15/16 amp modular switch, connection etc as reqd. (for power plug)
9Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess i/c P/F 3 pin5/6 amp modular socket out let and 5/6 amp modular switch, connection etc as reqd. (for light plugs to be used in non resdl bldgs)
10Supplying and fixing 2+8 way, double door single pole and neutral, sheet steel, MCB distribution board, 230 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB/Isolator)
11Supplying and fixing 2+4 way, double door single pole and neutral, sheet steel, MCB distribution board, 230 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB/Isolator)
12S/F following rating double pole 240 Volts isolator in the existing MCB DB complete with connections, testing and commissioing. 63 Amp
13S/F following rating double pole 240 Volts isolator in the existing MCB DB complete with connections, testing and commissioing. 40 Amp
14Earthing with G.I. earth plate 600mm X 600mm X 6mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc.with charcoal and salt as required.
15Earthing with G.I. earth pipe 4.5 mtr long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc.with charcoal and salt as required.
16Providing and laying of earth electrode with 6 SWG GI direct in 0.5 mtr below the ground level for the earth connection.
17Providing and fixing of lightning finial made of 25 mm dia 300 mm long G.I. tube having single prongat top with 85 mm dia 6 mm thick G.I. base plate i/c holes etc. complete as req.
18Providing and fixing testing joint made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 Nos of G.I. bolts,nuts,chuck nuts and spring washers etc.complete as req.
19Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall/GI pipe for lighting conductor complete as required. (For horizontal run)
20Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall/GI pipe for lighting conductor complete as required. (For vertical run)
21Supplying and laying of following size of 1.1 KV Grade PVC insulated PVC sheathed power cable of grade 1.1 KV armoured XLPE power cable of 2X25 Sqmm aluminium i/c excavation and reffiling the trench but excluding sand cushioing and protective covering etc as reqd.
22Supplying and laying of 1.1KV grade PVC sheathed power cable of grade 1.1KV armoured XLPE power cable of 2x10Sqmm Aluminum I/c excavation and refilling the trench ,but excluding sand cushioneing and protective covering etc as required.
23Supplying and laying of following size of 1.1 KV Grade PVC insulated PVC sheathed power cable of grade 1.1 KV armoured XLPE power cable of 3.5X120 Sqmm aluminium i/c excavation and reffiling the trench but excluding sand cushioing and protective covering etc as reqd.
24Supplying and fixing of 15/18Watt LED full glow pro 1x1 recess /Surface square type flat panel with high brightness for glare free homogenous illumination and separate electronic driver suitable for low depth ceiling i/c connection complete as required.Make - Crompton/Havells/Phillips
25Supply,Installation, testing and commissioning of energy saving ceiling fan having specification :- Size-1200mm ,50Watt ,Air delivery - 210CMM,Voltage-230V,Blades-aluminium , colour- Ivoury including wiring the down rods of standardlength (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.Make -Usha/Havells/Crompton
26Supply,Installation, testing and commissioning of energy saving ceiling fan having specification :- Size-900mm ,60Watt ,Air delivery - 118CMM,Voltage-230V,Blades-aluminium, colour- Ivoury including wiring the down rods of standardlength (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.Make -Usha/Havells/Crompton
27Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
28Providing and fixing of prewired 20/22 watt box type LED batten having 6000K/4000K CCT, extruded thermoplastic body with PC diffuser in unique square shape & 240 degree wide distribution directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing completeas required.Make- Havells/Phillips/Crompton/Panasonic/Bajajetc.as per direction of Engineer-In-charge.
29SITC 45/48Watt LED street light I/P voltage 220V AC, with suitable electronic driver and high power LED as light source,with secondary optics made in pressure die cast housing with toughned glass IP66 protection on existng GI pipe bracket i/c connection etc as required.Make- - Havells/Crompton/Bajaj/SYSKA
30P/F of 40/43mm Dia 1.5Mtr long GI Pipe (Medium class) bracket on the existing wall with suitable MS clamp 2Nos and Nut & bolt for mounting of LED fitting i/c painting etc as required as per direction of engineer incharge.
31SITC of fresh air exhaust with louver shutter 250mm sweep in the existing opening including making the hole to suitable size of above exhuast fan and making good the damage and finishing etc as required. As req. ( Havells/Usha/crompton or equi.)
32SITC of outdoor double door distribution board having dust and vermin proof compartmentalized panel made out of CRCA sheet required hardware duly treated for degusting in 7 tank process with dephosphating and with powder coating on both side of panel in desired shade. The panel having PU/Neoprene rubber gasket of not less than 3 mm thickness. Separate detachable gland plate suitable MS base channel/angle iron, hinged door with locking arrangement for equipment /switchgear thickness of sheet shall not be less than 1.6 mm up to 600 mm length/width of any compartment and be of 2.0 mm above 600 mm. Load bearing structure shall be of 2.0 mm thick sheet supported stand made byby angle iron (25x3mm) size (0.60x0.30x0.90)Mtr . Side wall and cable alley compartment having bolted type door with / without detachable extension type structure (Only outer area on all sides shall be measured & panel to be fabricated from CPRI approved fabricator) outdoor distribution board panel having 1.6mm thickof 400amp,415Volt capacity 4 strip copper bus bar by means of SMC/DMC type insulator ,Incuding 1 Nos 300/320Amp 4Pole(wSN) MCCB breaking capacity -40/45KA and 02nos 150Amp,25/26KA four pole MCCB &03 nos 100Amp 4 pole 25/26 KA MCCB for outgoing supply MCCB Make -Havells/Schnider/Legrand/C&S,including interconnections with proper color code 10Sqmm single core copper conductor with lugs etc as required as per direction of engineer incharge.Panel Size:- (1.20x0.90) X 0.30M
33SITC of outdoor double door distribution board having dust and vermin proof compartmentalized panel made out of CRCA sheet required hardware duly treated for degusting in 7 tank process with dephosphating and with powder coating on both side of panel in desired shade.The panel having PU/Neoprene rubber gasket of not less than 3mm thickness.Separate detachable gland plate suitable MS base channel/angle iron ,hinged door with locking arrangement for equipment/switchgear thickness of sheet shall not be less than 1.6 mm up to 600mm length/width of any compartment and be of 2.0mm above 600mm.Load bearing structure shall be of 2.0mm thick sheet supported stand made by angle iron(25x3mm) size(0.600x0.600x0.300)mtr.Side wall and cable alley compartment having bolted type door with/without detachable extension type structure (only outer area on all sides shall be measured &panel to be fabricated from CPRI approved fabricator )outdoor distribution board panel having 1.6mm thick of 400 Amp,415 Volt capacity 4strip copper bus bar by means of SMC/DMC type insulator,high tensile nuts and bolts spring washers in existing panel including bending,cutting in required shape and size and colour coding with heat shrinkable PVC sleeves copper bus bar installed on insulator ,including incommer MCCB 1 nos 100Amp,including interconnection with 16Sqmm PVC copper wire with proper lugs and thimbles etc as required as per direction of engineer incharge.Panel Size:-(0.60x0.60)x0.30m
34Pvdg and erection of medium class (duty) 80 mm GI pipe 9 mtr long i/c painting etc in cement concrete 1:3:6(I cement, 3 coarse sand, 6 stone aggregate 40 mm nominal size) foundation etc as reqd.