University Of Calicut has published Tender For Additional Electrification And Maintenance Work Of Director Room, Auditorium, Seminar Hall, Visitor Room At The Hrdc In The Calicut University.. Submission Date for this Tender is 23-04-2024. Electrification Work Tenders in calicut Kerala. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required. Group A. (1.10.1) |
2 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required. Group B. (1.10.2) |
3 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required - 2 x 1.5 sq.mm + 1x1.5 sq.mm earth wire. (1.14.1) |
4 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required - 2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire. (1.14.2) |
5 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required - 2X 4 sq. mm + 1 X 4 sq. mm earth wire. (1.14.3) |
6 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required - 4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire. (1.14.7) |
7 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. 3 X 1.5 sq.mm. (1.17.3) |
8 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. 3 x 2.5 sq. mm. (1.17.12) |
9 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. 3 x 4 sq. mm. (1.17.21) |
10 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm. (1.21.1) |
11 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25mm. (1.21.2) |
12 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch. (1.24.1) |
13 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15/16 amp switch. (1.24.3) |
14 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet. (1.24.4) |
15 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 amp socket outlet. (1.24.5) |
16 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. (1.26) |
17 | Supplying and fixing following size /modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm). (1.27.1) |
18 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mm X 75mm). (1.27.2) |
19 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm). (1.27.5) |
20 | Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden blockincluding connection etc as required. (1.33) |
21 | Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings). (1.56) |
22 | Supplying and fixing PVC batten/ angle holder including connection etc. as required.(1.58) |
23 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole. (2.10.1) |
24 | Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.100 amps. (2.13.3) |
25 | Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps. (2.13.1) |
26 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps.(2.15.2) |
27 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps.(2.15.3) |
28 | Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43). (90.11.1.10) |
29 | Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages, colour washing etc. as required.4 core 10 sq mm with factory made clamp. (90.12.7.40) |
30 | Supplying and fixing 22 to 25 W LED (PF >0.96 ,Harmonics 9%) recess mounted round shaped down lighter suitable for low ceiling heights, ceiling should be cut in required shape and make good connection etc complete. (od344593/2023_2024) |
31 | Wiring plug point along with wiring of light point including supply fixing 5A flush type modular switch and 3 pin plug socket in combined position.(Combined plug). (od332999/2023_2024) |
32 | Supply & installation of light fittings on flat iron bracket Supply,conveyance,installation, testing and commissioning the light fittings of following types made of CRCA sheet of .5mm thickness complete with all accessories and lamps etc. directly on wall using 2 nos. flat iron brackets made from 25x6mm flat iron, painting the flat iron bracket and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required.1200 mm 1X20W LED Lamp with box type fixture. (90.3.22.3) |
33 | Labour charges for Installation and commissioning of LED tube set on the existing old tube set frame. (od335294/2023_2024) |
34 | Dismantling Existing old main switch boards and return to the electrical store. And connect its cable to the DB. (od344904/2023_ 2024) |
35 | Labour charges for dismantling existing damaged electrical accessories from the existing switch boards such as switches, sockets,indicators,cover plate and fan regulators etc. Dismantled electrical accessories return to the electrical store with out causing any further damage. (od344905/2023_2024) |
36 | Supplying and fixing Cat FACE PLATE and information outlet (Key stone). (od344906/ 2023_2024) |
37 | Supply and fixing surface mount boxfor fixing face plate. (od344907/2023_2024) |
38 | Supply and fixing 8 port switch 10/100/1000 Mbs. (od347398/2023_2024) |
39 | Sup[plying and fixing of Cat 6 patch cord 1 mtr. (od347399/2023_2024) |
40 | Supplying and fixing of Cat 6 patch cord 3 metre length. (od347400/2023_2024) |
41 | Supply, installation, testing and commissioning of 400 mm AC sweep oscillating type wall mounting fan with suitable clamp and bolt. (od344908/2023 _2024) |
42 | Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface / recessed steel/PVC conduit as required 1 run of Cable. (1.53.1) |