Military Engineer Services-MES has published Tender For Repair Maintenance Of Split/ Window Type Acs, Refrigertaors, Water Coolers, Deep Freezers, Geysers, Fan Alongwith Connected Allied Works At Af Station Mohanbari And Dinjan Under Ge (Af) Mohanbari. Submission Date for this Tender is 06-05-2024. AMC of Air Condition Tenders in mohanbari Assam. Bidders can get complete Tender details and download the document.
FileName | File Description | File Size |
e843a119-dc72-4641-b0a7-13901e3997bc.html | Tender Notice | 0 KB |
BOQ_727727.xls | Tender Document | 0 KB |
Tender.pdf | Tender Document | 0 KB |
Tendernotice_1.pdf | Tender Document | 0 KB |
Sl. No. | Item Description |
1 | Material and labour for taking down window air conditioner 1.0/ 1.5 /2.0 TR,servicing, cleaning completely the cooling coil intially with hand blower,spraying with soap water solution and finally clean with clean water and refixing at same location with complete testing all as specified and directed. |
2 | Material and labour for dismantling indoor and outdoor covers of split type air conditioners, servicing, cleaning completely the condenser coil and cooling coil intially with hand blower, spraying with soap water solution and finally clean with clean water and refixing at same location with complete testing etc of following capacity and type completed all as specified and directed. |
3 | Split type AC of capacity 1.5 TR |
4 | Split type AC of capacity 2.0 TR |
5 | Carrying out pressure leak test by nitrogen gas pressure for detecting leak in condensing unit refigerant pipe and repairing the leak by the welding or brazing of condensing unit and refrigerant pipe, putting under pressure for leak checking after repairs of leak pipe transporting & carrying out T & P required at site for work of following capacity ACs, water coolers & refrigertors & deep freezers completed all as specified and directed. Notes :- Refrigeration gas charging as per existing type/ model / make after repairs is measured and paid seperately under revelant item |
6 | Window type AC of capacity 1.5 TR |
7 | Split type AC of capacity 1.5 TR |
8 | Split type AC of capacity 2.0 TR |
9 | Water cooler of capacity 40/80 ltrs |
10 | Water cooler of capacity 60/120 ltrs |
11 | Refrigerator of capacity upto 220 ltrs |
12 | Refrigerator of capacity more than 220 ltrs upto 310 ltrs |
13 | Deep freezer of capacity upto 320 Ltrs |
14 | Supply and fixing in repairs compressor for window / split type / water cooler / refrigerator / deep freezer etc. of following capacity and type complete all as specified and directed. |
15 | Sealed unit reciprocating type for window type AC of capacity 1.5 TR |
16 | Sealed unit rotary type for window type AC of capacity 1.5 TR |
17 | Sealed unit reciprocating type for split type AC of capacity 1.5 TR |
18 | Sealed unit reciprocating type for split type AC of capacity 2.0 TR |
19 | Sealed unit rotary type for split type AC of capacity 1.5 TR |
20 | Sealed unit rotary type for split type AC of capacity 2.0 TR |
21 | For water cooler of capacity 40/80 ltrs |
22 | For water cooler of capacity 60/120 ltrs |
23 | For refrigerator of capacity upto 220 ltrs |
24 | For refrigerator of capacity more than 220 ltrs upto 310 ltrs |
25 | For deep freezer of capacity upto 320 Ltrs |
26 | Labour only for collecting the complaints of various wards/ departments etc pertains to summer cooling applinaces (window ACs / split ACs / water coolers / refrigerators / deep freezers) of any make / model/ type,from concern JE E/M of AGE E/M, attendending these at site to assess the actual fault after opening of cooling appliances and fixing only spares required to make it fully functional in all respect and handing over the report duly signed by the user to concern JE complete all as specified and directed. Note:- Spares parts shall be measured and paid seperately under respective items as supply only. |
27 | Supply only capacitor running 2.5 mfd |
28 | Supply only capacitor running 4.0 mfd |
29 | Supply only capacitor running 15 mfd |
30 | Supply only capacitor Running 36 Mfd |
31 | Supply only capacitor Running 45 Mfd +_ 4 Mfd |
32 | Supply only capacitor Running 50 Mfd +_ 6 Mfd |
33 | Supply only capacitor Starting 80/100 Mfd |
34 | Supply only capacitor Starting 100/120 Mfd |
35 | Supply only capillary tube copper as per existing size |
36 | Supply only filter strainer as per existing size |
37 | Supply only starting relay as per existing size |
38 | Supply only contactor relay as per existing size |
39 | Supply only open type relay as per existing |
40 | Supply only bimetal realy as per existing |
41 | Supply only overload Protector as per existing |
42 | Supply only air filter made of plastic frame and nylon net |
43 | Supply only thermostatic switch as per existing |
44 | Supply only thermostat as per existing |
45 | Supply only front grill for as per existing size |
46 | Supply only rubber bushings for blowers motor as per existing |
47 | Supply only drain pipe as per existing |
48 | Supply only metal plug top 20 amps, 3pin |
49 | Supply only metal socket 20 amps, 3 pin |
50 | Supply only MCB 20 to 32 amps, C curve |
51 | Supply only pin/thread lamp holder |
52 | Supply only bulb 15 watt (pin/ thread type) |
53 | Supply only ice tray of refrigerator as per existing |
54 | Supply only chill tray of refrigerator as per existing |
55 | Supply only CP basin tray of refrigerator as per existing |
56 | Supply only ice chamber of refrigerator as per existing |
57 | Supply only vegetable box of refrigerator as per existing |
58 | Supply only heating element of existing capacity |
59 | Supply only timer as per existing model |
60 | Supply only push type tap copper alloy chromium plated 15 mm bore |
61 | Supply only rubber lining for top cover gasket ( 3 meter appox ) |
62 | Supply only float valve brass with fly nut screwed as per existing |
63 | Supply only sensor for indoor unit as per existing |
64 | Supply only sensor invertor type for indoor unit as per existing |
65 | Supply only blower fan (PVC) for split type |
66 | Supply only blower fan (PVC) for window type |
67 | PCB board repairing any type |
68 | Supply and fixed FR PVC insulated round sheathed copper cable conductor of size 2.5 sqmm 3 core complete all as specified and directed. |
69 | Supply and fixing in repairs swing motor for air conditioners as per existing type/ make /model complete all as specified and directed. |
70 | Split type AC of capacity 1.5 TR |
71 | Split type AC of capacity 2.0 TR |
72 | Dismantling of blower fan motor cutting burnt coils and taking out from the AC Unit / water cooler, cleaning and rewinding using supper enamaled copper wire of existing size and gauge including insulation materials change of bush (front and rear) made out of gun metal and reassembling all accessories and testing complete all as specified and directed. |
73 | Window type AC of capacity 1.5 TR |
74 | Split type AC of capacity 1.5 TR |
75 | Split type AC of capacity 2.0 TR |
76 | Water cooler of capacity 40/80 ltrs |
77 | Water cooler of capacity 60/120 ltrs |
78 | Supply and fixing in repairs blower motor for air conditioners as per existing type/ make /model complete all as specified and directed. |
79 | Window type AC of capacity 1.5 TR |
80 | Split type AC of capacity 1.5 TR |
81 | Split type AC of capacity 2.0 TR |
82 | Split type AC of capacity 1.5 TR invertor type indoor unit |
83 | Split type AC of capacity 2.0 TR invertor type indoor unit |
84 | Supply and fixing in repairs PCB board for air conditioners as per existing type/ make /model complete all as specified and directed. |
85 | Split type AC of capacity 1.5 TR |
86 | Split type AC of capacity 2.0 TR |
87 | Indoor unit PCB for Invertor type split AC of capacity 1.5 TR |
88 | Indoor unit PCB for Invertor type split AC of capacity 2.0 TR |
89 | Outdoor unit PCB for Invertor type split AC of capacity 1.5 TR |
90 | Outdoor unit PCB for Invertor type split AC of capacity 2.0 TR |
91 | Supply and fixing in repairs display assembly for air conditioners as per existing type/ make /model complete all as specified and directed. |
92 | Split type AC of capacity 1.5 TR |
93 | Split type AC of capacity 2.0 TR |
94 | Supply and fixing in repairs copper condenser fins type for air conditioners as per existing type/ make /model / capacity complete all as specified and directed. |
95 | Split type AC of capacity 1.5 TR |
96 | Split type AC of capacity 2.0 TR |
97 | Split type AC of capacity 1.5 TR invertor type outdoor unit |
98 | Split type AC of capacity 2.0 TR invertor type outdoor unit |
99 | Supply and fixing in repairs frost free fan motor for refrigerator/ deepfreezer as per existing type/ make /model / capacity complete all as specified and directed. |
100 | Supply and fixing in repairs condenser coil for refrigerator/ deepfreezer as per existing type/ make /model / capacity complete all as specified and directed. |
101 | Supply and charging refrigeration gas R-22 for summer cooling appliances complete all as specified and directed. |
102 | Supply and charging refrigeration gas R-410 for summer cooling appliances complete all as specified and directed. |
103 | Supply and charging refrigeration gas R-134A for summer cooling appliances complete all as specified and directed. |
104 | Labour only for dismantling, shifting and refixing of split type AC (indoor and outdoor unit complete)of any capacity /make / model including proper arrangement to keep outer unit (angle iron with nut bolt) complete all as specified and directed. |
105 | Supply and fix in repairs for sheet metal enclosure single pole and neutral with two pin and earth plug complete with one single pole MCB 20 amps, 230 volts complete all as specified and directed. |
106 | Taking down outdoor unit in repairs of any type /make /model/ capacity split ac, removing unserviceable AC stand/angle iron bracket fixing new AC stand/angle iron bracket (including two coats of paint over a red oxide primer) fixing to wall by foundation bolts refixing the outdoor unit at any height with connecting the suction and discharge line complete with testing and running complete all as specified and directed. |
107 | Dismantling of existing old unserviceable valves and supply and fixing in repairs new matching to exist one including all connection, testing etc complete all as specified and directed. |
108 | 5/8"(brass) service line charging valve |
109 | 1/4"(brass) liquid line valve |
110 | Dismantling of existing old unserviceable copper tubes and supply and fixing in new matching to exist one including all connection, testing etc complete all as specified and directed. |
111 | 5/8" copper tube |
112 | 1/4" copper tube |
113 | 1/2" copper tube |
114 | Taking down damaged copper tubes insulation and supply and fixing of new with following sizes complete all as specified and directed. |
115 | 5/8" copper tube insulation |
116 | 1/4" copper tube insulation |
117 | 1/2" copper tube insulation |
118 | Taking down unserviceable voltage stablizers, rewinding of isolation transformer unit with heavy duty super enamelled copper winding wire of existing gauge including all insulation materials, varnishing, heating etc and replacement of defective parts required to maintain constant voltage complete all as specified and directed. |
119 | Capacity up to 3 KVA |
120 | Capacity 4 KVA |
121 | Capacity 5 KVA |
122 | Labour only for collecting the complaints of Various wards/ departments/ qtrs etc pertains to geyser of any make / model/ type/ capacityfrom concern JE E/M of AGE E/M, attendending these at site to assess the actual fault after opening of geyser and fixing only spares required to make it fully functional in all respect and handing over the report duly signed by the user by name to concern JE complete all as specified and directed. Note:- Spares parts shall be measured and paid seperately under respective items as supply only. |
123 | Supply only heating element 1.5 KW as per existing model |
124 | Supply only heating element 2.0 KW as per existing model |
125 | Supply only thermostat long tail as per existing model and type |
126 | Supply only thermostat as per existing model and type |
127 | Supply only plug top 15 amps, 3 pin, 230 volts |
128 | Supply and fix metal connection pipe 15 mm dia 60 cm long heavy duty with two nos brass chromiuim plated union complete all as specified and directed. |
129 | Supply and fix stop valve chromium plated |
130 | Supply and fix indiacator lamp (red and green) |
131 | Supply and fix nut bolts and washers suitable for existing |
132 | Taking down geyser of any capacity, make, model, type from its position after disconnecting connection of geyser to take out to workshop for repairs and refixing back to its original position after repairs complete all as specified and directed. Note:- Spares parts shall be measured and paid seperately under respective items |
133 | Material only for soldering at two to three places in inner tank of any model/ make/ type/ material |
134 | Apparatus plate of any model/ make/ type /material. |
135 | Glass wool suitable for insulation |
136 | CP brass base plate with adaptor matching to existing size |
137 | Inner tank of any model/ make/ type /material as per existing. |
138 | Repair body and base of summer cooling appliances including providing of plain MS sheet and angle iron of existing thickness and size including necessary welding and brazing complete all as specified and directed. |
139 | Window type AC of any capacity /make/model |
140 | Outdoor unit of split type AC of any capacity /make/model |
141 | Water cooler any capacity /make/model |
142 | Material and labour for painting with two coats of DUCO paint (ISI grade) white using spray machine for spray painting including cleaning, washing, preparation of old painted surface and wiriting MES no complete all as specified and directed. |
143 | Window type AC of any capacity /make/model |
144 | Split type AC of any capacity /make/model |
145 | Water cooler any capacity /make/model |
146 | Geysers any capacity / make/ model |
147 | S& F in repair uPVC panel truncking system 75mm width, 75mm depth elongated flexible botom mounting fixed with and including necessary end joints, "T" bends and other accessories, clamps, nuts , bolts fixed to walls/ ceiling and top cover of 75mm width complete all as specified and directed. |
148 | Material and labour laying well burnt old sizebricks, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection all as specified. |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy