}

Tender For Repair/Maintenance Of Dg Sets, Eot Crane, Certain E/M Misc Works, Package Type Ac Plant, Window/Split Acs, Water Coolers, Refrigerators, Desert Coolers Etc At Mirc Under Ge (South) Ahmednagar, ahmednagar-Maharashtra

Military Engineer Services-MES has published Tender For Repair/Maintenance Of Dg Sets, Eot Crane, Certain E/M Misc Works, Package Type Ac Plant, Window/Split Acs, Water Coolers, Refrigerators, Desert Coolers Etc At Mirc Under Ge (South) Ahmednagar. Submission Date for this Tender is 11-05-2024. Mechanical engineering Service Tenders in ahmednagar Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

43166815
Corrigendum : Tender For Repair/Maintenance Of Dg Sets, Eot Crane, Certain E/M Misc Works, Package Type Ac Plant, Window/Split Acs, Water Coolers, Refrigerators, Desert Coolers Etc At Mirc Under Ge (South) Ahmednagar
Open Tender
Indian
Maharashtra
ahmednagar
11-05-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Tender For Repair/Maintenance Of Dg Sets, Eot Crane, Certain E/M Misc Works, Package Type Ac Plant, Window/Split Acs, Water Coolers, Refrigerators, Desert Coolers Etc At Mirc Under Ge (South) Ahmednagar

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 25-Apr-2024 amendment1 Other 04-05-2024
2 04-May-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 11-05-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 60000.0 /-
Tender Value
INR 30 Lakhs /-

Attachment

FileName File Description File Size
569fac66-7afa-4b96-83b5-2739ce206b8a.html Tender Notice 0 KB
8150Tenderdocuments.pdf Tender Document 0 KB
BOQ_727722.xls Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

Name of Work : REPAIR/MAINT OF DG SETs, EOT CRANE, CERTAIN E/M MISC WORKS, PACKAGE TYPE AC PLANT, WINDOW/SPLIT ACs, WATER COOLERS, REFRIGERATORS, DESERT COOLERS ETC AT MIRC UNDER GE (SOUTH) AHMEDNAGAR
Sl. No. Item Description
1M&L in repairs, 100mm thick, insulation sheet as per existing type for packing purpose of storage room at magzine AC plant all as specified and as directed
2S&F in repairs, NRV suitable for Refrigerator/Deep Freezer any capacity complete all as specified and as directed
3Taking down PVC/MS desert cooler of any size and make from bracket/ stand, spanning all three side shutters and taking out old wooden chips pad, cleaning outer and inner surface by rubbing with sand paper or wire brush, including water tank complete and replacement of cooling pad of set of three of any size, superior quality with chicken wire mesh, oiling/greasing to motor and pump including refixing properly at the same place as required at site complete all as specified and as directed.
4M&L in repairs/replacement of fan motor, 3 speed, single phase 230V AC supply, connecting and testing for desert cooler of any type and capacity all as specified and as directed.
5M&L in repairs/replacement of water circulating submersible pump with motor 1/20 HP, 230 volts AC, ISI marked including electric connection for desert cooler of any type and capacity all as specified and as directed.
6M&L in repairs, cutting burnt winding of fan motor and rewinding with supper enameled aluminium winding wire and replacing gun metal bush shaftfor desert cooler of any type and capacity all as specified and as directed.
7M&L in repairs, fan blade made of aluminium for desert cooler of any type and capacity all as specified and as directed.
8M&L in repairs, fan blade made of plastic of superior qualityfor desert cooler of any type and capacity all as specified and as directed.
9S&F in repairs, switch piano, flush type, 6 amp, 230V, AC, one way all as specified and as directed.
10S&F in repairs, plug top, 3 pin, 6 amp, 230V AC, ISI marked all as specified and as directed.
11M&L in repairs, Socket outlet 3 pin, 6A, flush type, 230 V complete all as specified and as directed.
12M&L in repairs, cooling pad of set of three of any size superior quality with chicken wire meshfor desert cooler of any type and capacity all as specified and as directed.
13M&L in repairs, PVC water distributor with PVC elbow and pipefor desert cooler of any type and capacity all as specified and as directed. Note:-The rate quoted shall deemed to be included the cost of elbow - 03 Nos, pipe-03 Nos of required length/dia and and distributor -01 No
14M&L in repairs, PVC insulated, sheathed, flexible, round, 3 core cable with copper conductor of size 1.0 sqmm, 2m length with 3 pin top all as specified and as directed.
15S&F in repairs, capacitor 4 mfd all as specified and as directed.
16S&F in repairs,PVC pipe, 15mm dia, heavy duty, all as specified and as directed.
17S&F in repairs, 3 speed regulator switch for desert cooler completeall as specified and as directed.
18S&F in repairs, cross arms, bracings, supports, clamps, angle and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, adjustable stand in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and as directed.
19M&L for repair to body (viz. sides, base, bottom of tank) of water cooler of any make/size by replacing rusted worn out portion with suitable plain mild steel sheet of existing gauge to match original, mild steel angle iron suitable to match the existing body including transportation from MES store yard to repair shop and back complete all as specified and as directed.
20Opening of voltage stabilizer of AC, single phase, 230V of 1/2/3/4/5 KVA capacity & make and detection of fault and replacement of defective parts like volt meter, auto cut relay, time delay relay PCB cards, LED, Switch Socket etc as per existing make and model as required at site. Notes : The rates quoted shall deemed to be included the cost of spare parts.
21S&F in repairs, transformer suitable for 1/2/3/4/5 KVA voltage stabilizer as per existing make & type complete all as specified and as directed.
22Taking out hermetically sealed compressor unit (uncut) of refrigerator, single phase, 240 Volts, AC Supply for 165 to 180 ltr capacity of any make and replacing sealed unit with reconditioned sealed unit of same brand including following works all as specified and as directed:-(Existing make -Godrej/ Whirlpool/LG/ Voltas/ Carrier/ Blue star/ Kirloskar / Tuchmesh/ Usha (i)Connection to suction/discharge pipewith necessary repairs and brazing. (ii) Replacing capillary tube of existing size and copper liquid filters. (iii) Flushing of entire system before gas charging .(iv) Gas charging and testing the unit to the entire satisfaction complete.
23All as per serial item No 22 but compressor unit of refrigerator 190 to 290 litre capacity.
24All as per serial item No 22 but compressor unit of deep freezer 200 to 320 litre capacity.
25S&F in repairs, heaterfor frost freerefrigerator of any type and capacity, as per existing make & model all as specified and as directed.
26S&F in repairs,freezer chest with cooling coil suitable for refrigerator 165 to 290 litre capacity as per existing make & model and fixing, connecting and testing completeall as specified and as directed.
27S&F in repairs,freezer chest with cooling coil suitable for Deep freezer of 300 to 320 litre capacity as per existing make & model all as specified and as directed.
28S&F in repairs, over load protector suitable for refrigerator of 165 to 320 ltr capacity as per existing make & model all as specified and as directed.
29S&F in repairs,thermostat switch (auto de-frost) suitable for refrigerator of 165 to 320 ltr capacity as per existing make & model all as specified and as directed.
30S&F in repairs, electric lamp pin/ threaded type, 240 volts, AC supplysuitable for refrigerator of 165 to 320 ltr capacity as per existing make & model all as specified and as directed.
31S&F in repairs, magnetic door gasket, superior quality, suitable for refrigerator/ Water Cooler of any capacity as per existing make & model all as specified and as directed.
32S&F in repairs, leg, suitable for refrigerator/Water Cooler of any capacity as per existing make & model all as specified and as directed.
33S&F in repairs, relay, suitable for refrigerator/deep freezer upto 320 ltr capacity as per existing make & model all as specified and as directed.
34S&F in repairs, capillary tube and drier filter, suitable for refrigerator of 165 to 320 ltr capacitywith brazing, nitrogen flushing, leak testing and gas charging all as specified and as directed. Note:- Charging of gas as specified by manufacturer will be measured and paid separately under respective item.
35Taking out old hermetically sealed compressor unit (uncut) from water cooler,storage type, 40/80 ltr/hr cooling capacity and replacing the sealed unit with factory made new sealed unit of same brand as per existing, including the following work all as specified and as directed. (Existing make - Godrej, Whirlpool, LG, Voltas, Carrier, Blue star, Kirloskar,Tuchmesh, Usha) (i) Connection to suction/discharge pipe with necessary repairs and brazing.(ii) Replacing capillary tube of existing size and copper liquid filters. (iii) Flushing of entire system before gas charging. (iv) Gas charging and testing after repairs including installing the machine at site and testing on full load for its smooth functioning complete.
36All as per serial item No 35 but for water cooler 60/120 ltr/hr cooling capacity.
37All as per serial item No 35 but for water cooler 120/150 ltr/hr cooling capacity.
38S&F in repairs, copper condensing coil with fixing arrangement of water cooler of 40/80litre capacity complete all as specified and as directed.
39S&F in repairs, fan blade for motor suitable for water cooler of 40/80 litre capacity as per existing make & model all as specified and as directed.
40S&F in repairs, thermostat suitable for water cooler of 40/80 litre capacity as per existing make & model all as specified and as directed.
41S&F in repairs, relay, suitable for water cooler of 40/80 litre capacity as per existing make & model all as specified and as directed.
42S&F in repairs, over load protector, suitable for water cooler of 40/80 litre capacity as per existing make & model all as specified and as directed.
43S&F in repairs, capacitor 10 mfd including necessary electrical connections, lugs, insulation tape etc complete suitable for water cooler of 40/80 litre capacity, all as specified and as directed.
44S&F in repairs, PVC flexible drain pipe length 2 meter, with proper fixing clip as per existing type & size suitable for water cooler any capacity all as specified and as directed.
45S&F in repairs, fan motor, 240 volts, single phase, AC supply, suitable for water cooler of 40/80, 60/120 & 150/150 litre capacity all as specified and as directed.
46S&F in repairs, copper condensing coil with fixing arrangement of water cooler of 60/120 & 150/150 litre capacity all as specified and as directed.
47S&F in repairs, fan blade for motor, suitable for water cooler of 60/120 & 150/150 litre capacity as per existing make & model all as specified and as directed.
48S&F in repairs,thermostate, suitable for water cooler of 60/120 & 150/150 litre capacity, as per existing make & model all as specified and as directed.
49S&F in repairs, relay suitable for water cooler of 60/120 & 150/150 litre capacity as per existing make & model all as specified and as directed.
50S&F in repairs, over load protector suitable for water cooler of 60/120 & 150/150 litre capacity as per existing make & model all as specified and as directed.
51S&F in repairs, internal wiring with PVC insulated copper conductor wire with lugs and thimbles complete suitable for water cooler of 40/80, 60/120 & 150/150 litre capacity all as specified and as directed.
52M&L in repairs, rewinding of fan motor suitable for water cooler of 60/120 & 150/150 litre capacity of any make with super enameled copper wire of existing size and weight as required including replacement of bushing and capacitor of 4.0 mfd complete all as specified and as directed.
53S&F in repairs,PTMT float valve assembly of 15 mm bore with plastic ball with suitable connections galvanized iron nipple 3” long and suitable GI sheet for fixing float valve suitable for water cooler of any make all as specified and as directed.
54S&F in repairs, 15mm bore stop cock, cast copper alloy, ISI marked, all as specified and as directed.
55S&F in repairs, GI pipe connector (male and female) 15mm bore pipe all as specified and as directed.
56S&F in repairs, 15 mm dia, concussive push taps of stainless steel alloy, screwed for iron pipe for water cooler all as specified and as directed.
57Dusting using blower and cleaning the housing from inside/out side, cooling system, cooling coil, condenser,capillary tube complete washingwith CTC liquid and leak detection, testingfor water cooler of 40/80, 60/120 & 150/150 litre capacity all as specified and as directed.
58M&L for gas charging to compressors of refrigerator, 165 to 180 litre capacity to its full capacity with specified grade of refrigerant including other connected process required for gas charging and testing complete all as specified and as directed.
59All as per serial item No 58 but for refrigerator, 190/200/290 litre capacity.
60All as per serial item No 58 but for water cooler of 40/80 litres capacity
61All as per serial item No 58 but for water cooler of 60/120 litres capacity
62All as per serial item No 58 but for water cooler of 150/150 litres capacity
63All as per serial item No 58 but for deep freezer 200 to 320 litre capacity
64Taking out hermetically sealed compressor unit(uncut) from the Split/Window Air conditioner of any make & type of 1.5 TR capacity and replacing the sealed unit with new sealed unit complete including following work all as specified and as directed. (Existing Make:- Voltas/ Carrier/ Blue star/ Kirloskar/ Tuchmesh/ Usha/ Godrej/ Whirlpool/ LG/ Kenstar)(i) Connection to suction/discharge pipe with necessary repair and brazing.(ii) Replacing the capillary tubes of existing size and copper liquid filter. (iii) Flushing of entire system before gas charging. (iv) Gas charging and testing after complete repairs including installation of the machine at site and testing on full load for its smooth functioning complete.
65All as per serial item No 64 but for Air Conditioner of 2.0 TR capacity.
66All as per serial item No 64 but for Air Conditioner of 3.0 TR three phase capacity.
67S&F in repairs, relay for existing make and model ofAC, window type, capacity 1.5 TR, single phase, 240 VoltsAC supply, including connecting and testing of relay all as specified and as directed.
68S&F in repairs, thermostat with switch for existing make and model ofAC, window type, capacity 1.5 TR all as specified and as directed.
69S&F in repairs, starting capacitor 80/100 mfdincluding necessary electrical connections, lugs, insulation tape etcfor existing make and model of AC, window type, capacity 1.5 TR all as specified and as directed.
70S&F in repairs, PCB electronic circuitfor existing make and model ofAC, window type, capacity 1.5 TR all as specified and as directed.
71S&F in repairs, remotefor existing make and model ofAC, window type, capacity 1.5 TR all as specified and as directed.
72S&F in repairs, blower made of PVC heavy dutyfor existing make and model ofAC, window type, capacity 1.5 TR all as specified and as directed.
73S&F in repairs, condenser fan blade made of PVC heavy dutyfor existing make and model ofAC, window type, capacity 1.5 TR all as specified and as directed.
74S&F in repairs, running capacitor 50/60 mfdincluding necessary electrical connections, lugs, insulation tape etc for existing make and model ofAC, window type, capacity 1.5 TR all as specified and as directed.
75S&F in repairs, PVC air filter, 20 micronfor existing make and model ofAC, window type, capacity 1.5 TR all as specified and as directed.
76S&F in repairs, internal wiring kit of PVC insulated copper conductor wirefor existing make and model ofAC, window type, capacity 1.5 TR all as specified and as directed.
77S&F in repairs, over load protector for existing make and model ofAC, window type, capacity 1.5 TR all as specified and as directed.
78M&L in repairs, cutting, removing of burnt winding of fan motor/condenser fan motor of window type AC of any make and rewinding with super enameled copper winding wire of existing size and weight including replacement of bushingfor existing make and model ofAC, window type, capacity 1.5 TR all as specified and as directed.
79S&F in repairs, copper condenser/ evaporator coil with brazing, nitrogen flushing, leak testing and gas chargingfor existing make and model ofAC, window type, capacity 1.5 TR.all as specified and as directed. Note:- Charging of gas as specified shall be measured and paid under respective item.
80S&F in repairs, capillary tube and drier filter of any make for 1.5 TR window AC with brazing, nitrogen flushing, leak testing and gas charging complete all as specified and as directed.Note:- Charging of gas as specified shall be measured and paid in respective item .
81M&L in repairs, old PCB electronic circuit of 1.5 TR Window AC and repair and refix same all as specified and as directed.
82S&F in repairs,relay for existing make and model of split type AC of capacity 1.5 TR single phase, 240 Volts, AC supply including connecting and testing of relayall as specified and as directed.
83S&F in repairs, thermostat with switch for existing make and model of split type AC of capacity 1.5 TR all as specified and as directed.
84S&F in repairs, starting capacitor 80/100 mfd or suitable capacity including necessary electrical connections, lugs, insulation tape etc for existing make and model of split type AC of capacity 1.5 TR all as specified and as directed.
85S&F in repairs, fan blade made of PVC, heavy duty for out door unit for existing make and model of split type AC of capacity 1.5 TR all as specified and as directed.
86S&F in repairs, shut off valve brass with flair nut complete for existing make and model of split type AC of capacity 1.5 TR all as specified and as directed.
87S&F in repairs, PCB electronic circuit including LCD of indoor/ outdoor unit of 1.5 TR of existing make and model of split AC all as specified and as directed.
88S&F in repairs, remote for existing make and model of split type AC of capacity 1.5 TR all as specified and as directed.
89S&F in repairs, swing assembly complete made of PVC, heavy duty for existing make and model of split type AC of capacity 1.5 TR all as specified and as directed.
90S&F in repairs, swing motor, single phase, AC supply, for indoor unit.of existing make and model ofsplit type AC of capacity 1.5 TR all as specified and as directed.
91S&F in repairs, blower made of PVC, heavy duty for indoor unit of existing make and model ofsplit type AC of capacity 1.5 TR all as specified and as directed.
92S&F in repairs, running capacitor 45/50 mfdincluding necessary electrical connections, lugs, insulation tape etc for existing make and model of split type AC of capacity 1.5 TR all as specified and as directed.
93S&F in repairs, PVC air filter, 20 micron for existing make and model of split type AC of capacity 1.5 TR all as specified and as directed.
94S&F in repairs, internal wiring kit of PVC insulated copper conductor wire for indoor/outdoor unit of existing make and model of split type AC of capacity 1.5 TR all as specified and as directed.
95S&F in repairs, over load protector for existing make and model of split type AC of capacity 1.5 TR all as specified and as directed.
96M&L in repairs, cutting burnt winding of blower motor of split type AC 1.5 TR of any make and rewinding with super enamelled copper winding wire of existing size and weight including replacement of bushing all as specified and as directed.
97S&F in repairs, condenser fan motor for Split AC 1.5 TR as per existingcapacity 415 Volts, 50 Hz, speed up to 1000 RPM all as specified and as directed.
98S&F in repairs, copper condenser/evaporator coil of outdoor/indoor units respectively of 1.5 TR split AC with brazing, nitrogen flushing, leak testing and gas charging complete all as specified and as directed.Note:- Charging of gas as specified by manufacturer will be measured and paid in respective item .
99S&F in repairs, gromate with fixing arrangement for existing make and model of split type AC of capacity 1.5 TR all as specified and as directed.
100S&F in repairs, capillary tube and drier filter of any make of 1.5 TR split AC with brazing, nitrogen flushing, leak testing and gas charging complete.all as specified and as directed.Note:- Charging of gas as specified shall be measured and paid under respective item .
101M&L in repairs, old PCB electronic circuit of 1.5 TR Split AC and repair and refix same all as specified and as directed.
102S&F in repairs, relay as per existing make and model of splittype AC of capacity 2.0 TR, single phase, 240 Volts, AC supply including connecting and testing of relay all as specified and as directed.
103S&F in repairs, thermostat with switch ofexisting make and model of splittype AC of capacity 2.0 TR all as specified and as directed.
104S&F in repairs, fan blade made of PVC heavy duty for out door unit of existing make and model of splittype AC of capacity 2.0 TR all as specified and as directed.
105S&F in repairs, shut off valve brass with flair nut for existing make and model of splittype AC of capacity 2.0 TR all as specified and as directed.
106S&F in repairs, PCB electronic circuit including LCD for existing make and model of splittype AC of capacity 2.0 TR all as specified and as directed.
107S&F in repairs, remote for existing make and model of splittype AC of capacity 2.0 TR all as specified and as directed.
108S&F in repairs, swing assembly complete made of PVC, heavy duty of existing make and model of splittype AC of capacity 2.0 TR all as specified and as directed.
109S&F in repairs, swing motor, single phase AC supply for indoor unit.of existing make and model of splittype AC of capacity 2.0 TR all as specified and as directed.
110S&F in repairs, blower made of PVC heavy duty for indoor unit of existing make and model of splittype AC of capacity 2.0 TR all as specified and as directed.
111S&F in repairs, running capacitor 50/60 mfd or as per existing capacity including necessary electrical connections, lugs, insulation tape etc for splittype AC of capacity 2.0 TR all as specified and as directed.
112S&F in repairs, PVC air filter, 20 micron for existing make and model of splittype AC of capacity 2.0 TR all as specified and as directed.
113S&F in repairs, internal wiring kit of PVC insulated copper conductor wire for indoor/outdoor unit of existing make and model of splittype AC of capacity 2.0 TR all as specified and as directed.
114S&F in repairs, over load protector of existing make and model of splittype AC of capacity 2.0 TR all as specified and as directed.
115M&L in repairs for cutting burnt winding of blower motor of existing make and model of split type AC 2.0 TR of any make and rewinding with super enamelled copper winding wire of existing size and weight including replacement of bushing all as specified and as directed.
116S&F in repairs, condenser fan motor for Split AC 2.0 TR as per existingcapacity 415 Volts, 50 Hz, speed up to 1000 RPM all as specified and as directed.
117S&F in repairs, copper condenser/evaporator coil of outdoor/ indoor units respectively of 2 TR split AC with brazing, nitrogen flushing, leak testing and gas charging complete all as specified and as directed.Note:- Charging of gas as specified by manufacturer will be measured and paid in respective item .
118Removing, repairing & refixing, copper condenser/evaporator coil of outdoor/ indoor units respectively of 2 TR split AC with brazing, nitrogen flushing, leak testing and gas charging complete all as specified and as directed. Note:- Charging of gas as specified shall be measured and paid in respective item .
119S&F in repairs, gromate with fixing arrangement for existing make and model of splittype AC of capacity 2.0 TR all as specified and as directed.
120M&L in repairs, old PCB electronic circuit of indoor/ outdoor unit for 2.0 TR Split AC and repair and refixing same all as specified and as directed.
121S&F in repairs, relay as per existing make and model of splittype AC of capacity 3.0 TR, three phase Three phase, 240 Volts, AC supply including connecting and testing of relay all as specified and as directed.
122S&F in repairs, fan blade made of PVC heavy duty for out door unit of existing make and model of splittype AC of capacity 3.0 TR, three phase all as specified and as directed.
123S&F in repairs, shut off valve brass complete with flair nut for existing make and model ofsplittype AC of capacity 3.0 TR, three phase all as specified and as directed.
124S&F in repairs, PCB electronic circuit including LCDfor existing make and model ofsplittype AC of capacity 3.0 TR, three phase all as specified and as directed.
125S&F in repairs, remotefor existing make and model ofsplittype AC of capacity 3.0 TR, three phase all as specified and as directed.
126S&F in repairs, swing assembly complete made of PVC heavy dutyfor existing make and model ofsplittype AC of capacity 3.0 TR, three phase all as specified and as directed.
127S&F in repairs, swing motor, single phase AC supply for indoor unit. for existing make and model ofsplittype AC of capacity 3.0 TR, three phase all as specified and as directed.
128S&F in repairs, blower made of PVC heavy duty for indoor unitfor existing make and model ofsplittype AC of capacity 3.0 TR, three phase all as specified and as directed.
129S&F in repairs, PVC air filter, 20 micronfor existing make and model ofsplittype AC of capacity 3.0 TR, three phase all as specified and as directed.
130S&F in repairs, internal wiring kit of PVC insulated copper conductor wire for indoor/outdoor unit of existing make and model ofsplittype AC of capacity 3.0 TR, three phase all as specified and as directed.
131S&F in repairs, over load protector. for existing make and model ofsplittype AC of capacity 3.0 TR, three phase all as specified and as directed.
132M&L in repairs for cutting burnt winding of condenser fan motor of splittype AC of capacity 3.0 TR, three phase of any make/model and rewinding with supper enamelled copper winding wire of existing size and weight including replacement of bushing all as specified and as directed.
133S&F in repairs,for cutting burnt winding of blower motor of splittype AC of capacity 3.0 TR, three phase of any make/model and and rewinding with super enamelled copper winding wire of existing size and weight including replacement of bushing all as specified and as directed.
134S&F in repairs, condenser fan motor for Split AC 3.0 TR three phase as per existingcapacity 415 Volts, 50 Hz, speed up to 1000 RPM all as specified and as directed.
135S&F in repairs, copper condenser/ evaporator coil of outdoor/ indoor units respectively of 3 TR split AC three phase with brazing, nitrogen flushing, leak testing and gas charging complete all as specified and as directed. Note:- Charging of gas as specified shall be measured and paid in respective item .
136S&F in repairs, gromate with fixing arrangementfor existing make and model ofsplittype AC of capacity 3.0 TR, three phase all as specified and as directed.
137S&F in repairs, contactorfor existing make and model ofsplittype AC of capacity 3.0 TR, three phase all as specified and as directed.
138M&L in repairs, old PCB electronic circuit of indoor/ outdoor unit for 2.0 TR Split AC and repair and refixing same all as specified and as directed.
139Servicing of AC, window type, 1.5 TR capacity of any make, by cleaning the whole equipment, washing of filters, minor adjustments/repair, washing condenser unit all as specified and as directed.
140All as per serial item No 139 but AC, split type, 1.5/2.0 TR capacity, indoor and out door unit.
141All as per serial item No 139 but AC, split type, 3 TR three phasecapacity, indoor and out door unit.
142M&L for gas charging to compressors of AC, window type, 1.5 TR capacity of any make, installed machine/equipment to its full capacity with specified grade (as per OEM recommended) of refrigerant including other connected process required for gas charging and testing complete all as specified and as directed.
143All as per serial item No 142 butbut AC, split type, 1.5 TR capacity of any make.
144All as per serial item No 142 butbut AC, split type, 2.0 TR capacity of any make.
145All as per serial item No 142 butbut AC, split type, 3.0 TR three phase capacity of any make.
146Removal and refixing of split AC of capacity 1.5/2.0 /3.0 TR including making hole in the brick/ shelter/ stone walls and making connections, fixing of brackets and insulating pipe lines with nitrile rubber, brazing of copper tubes including testing/ commissioning complete as required at site, including shifting of service connection, metal clad box and voltage stabilizer to the new location all as required. SOP is to be followed by proper pumping down of refrigerant gas before dismantling all as specified and as directed. Note :(i) The rate quoted shall deemed o be included transportation, civil work and making good to the disturb surfaces. (ii) Refrigerant pipes shall be measured and paid under respective item.
147Removal and refixing of AC window type of capacity 1.5/ 2.0 TR of any make complete with metal clad box, voltage stabilizer and service connection from one location to another and re-fixing the same by cutting steel/ wooden window/ removing glass pans etc and making opening for AC air tight by providing bedding/ rubber packing wooden frame etc complete including testing/ commissioning complete as required at site all as specified and as directed. Note : (i) The rate quoted shall deemed to be included transportation, civil work and making good to the disturb surfaces
148S&F in repairs, connecting and testing copper refrigerant pipes, along with proper insulation with nitrile rubber of suitable size for incoming and outgoing pipes complete all as required at site for 1.5/2.0 TR/3.0 TR split AC all as specified and as directed. Note : One run of both copper pipes incoming and outgoing shall be measured as 01 RM unit for payment purpose
149S&F in repairs, nylon pipe, cotton breaded, size 15mm dia, suitable for drain of split type AC, capacity 1.5/2.0/3.0 TR all as specified and as directed.
150S&F in repairs, mounting frame/ stand including fasteners and nut bolts suitable for outdoor unit of split AC of any size complete all as required at site all as specified and as directed.
151S&F in repairs and connecting PVC insulated and over all sheathed aluminium conductor, 10 sqmm, twin core, flat service connection, one end to be connected at sheet metal enclosure and other end at LT over head line at nearest pole all as required at site and all as specified and as directed.
152S&F in repairs, sheet metal enclosure, single pole & neutral with two pin & earth plug and socket with one MCB, single pole, 20 amp, 240 volts complete all as specified and as directed.
153S&F in repairs, metalic plug top, 3 pin for AC point, single phase, 240 volts, AC ISI marked, all as specified and as directed.
154S&F in repairs, metalic socket, 3 pin for AC point, single phase, 240 volts, AC ISI marked all as specified and as directed.
155S&F in repairs, MCB, SP, 25 Amp, 10 KA, "C" series all as specified and as directed.
156M&L in repairs, PVC insulated, sheathed, flexible, round, 3 core cable with copper conductor of size 2.5 sqmm for AC all as specified and as directed.
157M & L for cleaning surface of water cooler, refrigerator with detergent etc complete all as specified and as directed.
158M&L in repairs, for duct insulation with resin bonded fibre glass wool roll of density 24 kg/Cum, with factory laminated aluminium vapour barrier, thickness of insulation as specified andincluding the following:- (a) M&L for cleaning the duct surface (to be insulated ) by scrapping carefully with wire brush etc. to make the surface completely free of millscale, dirt, dust, grease and other foreign materials, taking special care so that all duct joints are sealed against any leakage. (b) M&L for applying rubber based adhesive CPRX compound. (c) M&L for sealing of all longitudinal joints and circular overlaps with and including Aluminium foil tape 50 mm wide, to make the insulation leakproof. (d) M & L for securing the insulation with and including mechanically fastened nylon/steel straps of size 12 mm/50 mmat maximum intervals of 1.2 mtr.
159Dismantaling old Unserviceable duct and fabricate and fix new GI sheet 24 gauge with C & SS rectagular / square duct made out of shapped hollow profile, duly factory boxed including all accessories such as corners cleat, carriage bolts , gasket and appropriate sealent on longitudinal joints complete all as specified and as directed.
160Taking out old Unserviceable gasket of discharge and suction valves of packaged type AC plant of capacity 10 TR and replaceing the same with new gasket complete all as specified and as directed.
161Taking out old Unserviceable pressure cut off cut-out and replacing the same with new pressure cut out of any type ,model, size required and testing for gas leakage complete all as specified and as directed.
162M&L for servicing of packaged type AC of capacity 10 TR, three phase, blower, including dismantling, rewinding and re-installing and change of existing blower cloth, fan blade, duct work, filter, insulation material inside of packaged type AC unit and other materials. hermetically sealed compressor by removing nuts and blocking plates of suction and discharge valves, leakage testing with and including nitrogen gas arresting the leakage, charging refrigerent gas (R-22) or as per OEM recommended and fix new PCB reassembaling the complete system testing and commissioning of the compressor to the entire satisfaction of Engineer in charge. Notes :- (i)Replacement of material shall be measured and paid as supply only parts under the relevent items(ii) Refrigerant gas will be measured and paid under the relevent items (iii) Machining work as required deemed to be included in the unit rate quoted. (iv) The parts replaced shall be of make & size as per existing and shall be replaced after approval of Engineer-in-Charge.
163S&F in repairs pressure gauge (low/high) for packaged air conditioning plant of 10TR capacity
164S&F in repairs solenoid valvefor packaged air conditioning plant of 10TR capacity
165S&F in repairs suction valvefor packaged air conditioning plant of 10TR capacity
166S&F in repairs discharge valve for packaged air conditioning plant of 10TR capacity
167S&F in repairs air filter as per existing shape and mateial for packaged air conditioning plant of 10TR capacity
168S&F in repairs brass pressure valve 1/2 inchesfor packaged air conditioning plant of 10TR capacity of make BLUESTAR or as per existing at site.
169S&F in repairs gas filter 1/2 inchesfor packaged air conditioning plant of 10TR capacity of make BLUESTAR or as per existing at site.
170S&F in repairs filter drierfor packaged air conditioning plant of 10TR capacity of make BLUESTAR or as per existing at site.
171S&F in repairs out door unit condencing coilfor packaged air conditioning plant of 10TR capacity of make BLUESTAR or as per existing at site.
172S&F in repairs copper tubesfor packaged air conditioning plant of 10TR capacity of make BLUESTAR or as per existing at site.
173S&F in repairs cooling coil for packaged air conditioning plant of 10TR capacity of make BLUESTAR or as per existing at site.
174M&L in repairs, Micro Computer Control (MCC)/Air conditioner control panel for control packaged type AC unit capacity of 10 TR viz contactor (Evap, Fan motor, compressor), overload relay (Evap, Fan motor), Reset P.B., Snubber, Toggle Switch, Thermostat, HI/LO PR control, Control relay, Glass fuse link compressor, Evaporator fan motor, Condensor fan motor and including any parts Make : Bluestar or as per existing at site all as specified and directed. Note : The unit rate quoted shall deemed to be included the cost of spare parts.
175S&F in repairs, over load relay, suitable capacity as per existing size and make fixed in LT panel board of AC plant Capacity 10 TR complete all as specified and as directed.
176S&F in repairs, power contactor ML-3, 63 A, 415 volts, 50 Hz ,TP for compressor motor all as specified and as directed.
177S&F in repairs, MCB, TPN, 63 A, all as specified & as directed.
178S&F in repairs, MCCB, TP, 100 A, 415 volts, all as specified & as directed.
179S&F in repairs/replacement, new sealed reciprocating type compressor of capacity 5 ton suitable for thepackage unit AC of 2 x 5 TR capacity, three phase including soldering of copper pipe, cleaning of the refrigerant system of AC, charging of refrigerant and rubber pads for foundation, nuts and bolts etc. and testing & commissioningof AC plant complete all as specified and as directed.Make: Copeland / As per existing at site
180S&F in repairs/replacement of condensor fan motor blades for packaged type ACincluding installation, commission and testing complete all as specified and as directed.
181M&L for rewinding of condensor fan motor of capacity 0.75 HP, 415 Volts for packaged unit AC with super enamelled copper conductor wire of best quality, guage and weight and including replacement of insulation material, connection of plate and ressembling the motor including installation commision and testing complete all as specified and as directed.
182S&F in repairs, voltage stabilizer, 5 KVA capacity for automatic operation, single phase, naturally air cooled, indoor type and designed for input variation between 170V to 250V with output voltage stablized at 230V with accuracy of (+) 2.5%complete all as specified & as directed.
183S&F in repairs, voltage stabilizer, 2 KVA capacity for automatic operation, single phase, naturally air cooled, indoor type and designed for input variation between 170V to 250V with output voltage stablized at 230V with accuracy of (+) 2.5%complete all as specified & as directed.
184M&L in repairs, point wiring with 1.5 Sqmm(22/0.30mm) PVC insulated andunsheathed multistranded copper conductor cable, 1100 volts grade, ISI marked, FRLSH type drawn through and including PVC casing and caping (ISI marked) and its accessories such as Tee, elbow, jointer, elbow corner etc. fixed on surface of walls, coloumns/ beams alongwith 1.5 Sqmm (nominalarea) copper conductor cable (multistranded)PVC insulated and unsheathed as earth wire connected to common earth dolly at one end and metalic bodies of luminaire/ fan at other end including PVC folding boards or wooden boards with sunmica top for mounting switches, sockets, fan Regulators, accessories etc for one 3 pin socket outlet, 5 Amps all as specified and directed.
185All as per ser Item No 184 here in before but one 3 pin socket outlet, 15 Amps with 4.0 sqmm cable on independent board.
186S&F in repairs, switch socket combination flush type 5 pin 5 Amp multipurpose 230 volts single pole one way suitable for 3 pin/2pin 5 Amp plug top white/ivory finish all as specified & directed.Make - Plaza / Havells / Leader /Vinay.
187S&F in repairs, switch socket combination multipurpose flush type 5 in 1 type, 6/16 Amps, 230V, AC. all as specified & directed.
188Supply, install, testing and commissioning factory made Cubical APFC PANEL of 180 kvar Outdoor type, double Door Type CPRI approved with front open including door locking arrengement. The panel shall be dust and vermin proof, made of 3.15 mm CRCA MS sheet and with base frame of MS flat iron 40mm x 6mm & angle of 40mm x 40mm x 6 mm frame with legs of 450 mm long embedded in PCC (1:2:4) b type B2 platform of suitable size including necessary excavation & earth work, dust & vermin proof painted outside & inside with one coat of Red oxide & two coats of approved make grey enanmeld paint complete pre wired with suitable size, all necessary power & control Protections (given below). All as specified and as directed by Eng-in-charge. (1) 300 A MCCB, 36 ka With Handle & spreder, DN3- L & T 1 NOS(2) 63 A TP MCB L & T 6 NOS(3) 32A TP MCB L & T 1 NOS(4) 20 A TP MCB L & T 1 NOS(5) 10 A TP MCB L & T 1 NOS(6) Capacitor duty contactor 25 kvar L & T 6 NOS (7) Capacitor duty contactor 15 kvar L & T 1 NOS (8) Capacitor duty contactor 10 kvar L & T 1 NOS (9) Capacitor duty contactor 5 kvar L & T 1 NOS(10) Cylinder type capacitor Heavy duty 25 kvar 525v Epcos 6 NOS (11) Cylinder type capacitor Heavy duty 15 kvar 525v Epcos 1 NOS(12) Cylinder type capacitor Heavy duty 10 kvar 525v Epcos 1 NOS(13) Cylinder type capacitor Heavy duty 5 kvar 525v Epcos 1 NOS(14) Cu Detune Reactors 7 % 25 kvar L & T 6 NOS (15) Cu Detune Reactors 7 % 15 kvar L & T 1 NOS(16) Cu Detune Reactors 7 % 10 kvar L & T 1 NOS (17) Cu Detune Reactors 7 % 5 kvar L & T 1 NOS(18) APFC Controller 12stage L & T 1 NOS(19) RYB Indicator idel 3 NOS (20)A/M selector switch with No-Nc sulzer 9 NOS(21) Red led indicator idel 9 NOS(22) 40 x 10 AL., bus bar , insulator , sleeve etc std 1 SET (23) Cable, lugs, ferrols, cable tray,etc Polycab 1 SET(24) Panel fabication (1600 w x 1750h x 500 d ) RK 1 SET (25) Control mcb 1P 6 A L & T 4 NOS (26) VAF Meter L & T 1 NOS (27) C.T. 160/5 Elmex 4 NOS
189Inspection, maintenance and servicing of DG set, 320 KVA, Make : GREAVES POWER, Model no. GPWII-320Eincluding alternator, electric panel board connection to DG Set for routine check ("A" check) of DG set for smooth functioning and carriying out maintenance as under :-Monthly Service (a)Checking engine oil level and topping up as and when requiredNOTE : Oil shall be measured and paid separately (b) Checking and adjusting the belt for tension and replacemnt of belt NOTE: Belt shall be measured and paid separately (c) Checking of oil bath air cleaner level(d) Checking of exhaust system for leakage (e) Draining of sediment from fuel filter and fuel tank(f) Cleaning of air cleaner element. Note : Replacement of Air Cleaner shall be measured and paid separately. (g) Checking engine alternator coupling, mounting boltsand alignment.(h)Tighting all nut, bolts, in alternator terminal block. (j)Checking ofalternator carbon brush and connections in alternator(k)Checking and tighting of all connection in DC control wiring. (l)Checking ofall radiator rubber hose and replacementif required. NOTE : Hose pipes shall be measured and paid separately (m)Checking and recording oil pressure, water and oil temperature (n) Checking anti vibration mounting and replacement if required. NOTE: Antivibration pad shall be measured and paid separately(o) Checking throttle linkage (p) Checking battery for cell test, electrolyte level, gravity and topping up to required level (q) Routine check / repair work of panel, switch, MCCB, main switch, all contactor, engine control unit.
190All as per serial item No. 189 but for 125 KVA DG set, Make ; KIRLOSKAR, Model KG 125 WS
191All as per serial item No. 189 but for 100 KVA DG set, Make ; KIRLOSKAR Model KG 125 WS/Model no. KG100W52
192All as per serial item No. 189 but for 82.5 KVA DG set, Make ; CUMMINS M/C no 9920805-001
193All as per serial item No. 189 but for 62.5 KVA DG set, Make ; CUMMINS, MODEL NO. 4BTAA3.3G11
194All as per serial item No. 189 but for 50 KVA DG set, Make ; GREAVES COTTON, MODEL NO. 3G11TAG25
195All as per serial item no. 189 but for 40 KVA DG set, Make ; KIRLOSKAR
196All as per serial item no. 189 but for 40 KVA DG set, Make ; ASHOK LEYLAND MODEL NO. ALGPW04DMK1.E4
197Material and labour required for `B" CHECKinspection, maintenance, servicing of DG set 320 KVAMake GREAVES POWER, Model no. GPWII-320Eincludingitems covered in `B" check of DG set for smooth functioning and carriying out maintenance complete all as per OEM instructions and as directed under :- (a) Repeat the activities of "A" check (b)Replacing lubricant oilNote:- Lub Oil are Paid separately. (c) Replacing lubricant oil filter element with `O" ring(d) Replacing fuel filter element(e) Replacing Bypass Filter(f) Replacing Air Filter (g) Replacing Governer oil (h) Replacing coolant NOTES : i) `B" CHECK ONCE INSIX MONTH OR 300-350 HRS RUNNING OF DG SET WHICHEVER IS EARLIER ii) `B" check kit, coolant, Lubricant Oil shall be measured and paid seperately under relevant item.
198All as per serial item No. 197 but for 125 KVA DG set, Make ; KIRLOSKAR, Model KG 125 WS
199All as per serial item No. 197 but for 100 KVA DG set, Make ; KIRLOSKAR Model KG 125 WS/Model no. KG100W52
200All as per serial item No. 197 but for 82.5 KVA DG set, Make ; CUMMINS M/C no 9920805-001
201All as per serial item No. 197 but for 62.5 KVA DG set, Make ; CUMMINS, MODEL NO. 4BTAA3.3G11
202All as per serial item No. 197 but for 50 KVA DG set, Make ; GREAVES COTTON, MODEL NO. GPWII-PII-50
203All as per serial item No. 197 but for 40 KVA DG set, Make ; KIRLOSKAR
204All as per serial item No. 197 but for 40 KVA DG set, Make ; ASHOK LEYLAND MODEL NO. ALGPW04DMK1.E4
205Supply only B" Check Kit for DG set 320 KVA,Make ; GREAVES POWER, Model no. GPWII-320E complete allas per OEM instructions and as specified and as directed. Note : Quoted rate shall be included for oil filter (1.00 Ltr/0.5 ltr), Air Filter, Fuel/Diesel filter, by pass filter with element etc.
206All as per serial item No. 205 but for 125 KVA DG set, Make ; KIRLOSKAR, Model KG 125 WS
207All as per serial item No. 205 but for 100 KVA DG set, Make ; KIRLOSKAR Model KG 125 WS/Model no. KG100W52
208All as per serial item No. 205 but for 82.5 KVA DG set, Make ; CUMMINS M/C no 9920805-001
209All as per serial item No. 205 but for 62.5 KVA DG set, Make ; CUMMINS, MODEL NO. 4BTAA3.3G11
210All as per serial item No. 205 but for 50 KVA DG set, Make ; GREAVES COTTON, MODEL NO. GPWII-PII-50
211All as per serial item No. 205 but for 40 KVA DG set, Make ; KIRLOSKAR
212All as per serial item No. 205 but for 40 KVA DG set, Make ; KIRLOSKAR, ASHOK LEYLAND MODEL NO. ALGPW04DMK1.E4
213Disconnecting all the connections from alternator of320/125/100/82.5/62.5/50/40 KVADG set,removing the alternator from foundations , transporting to workshop, dismaintling completely including starter, roter, removing rotor and bearing, cleaning all the parts with thinner and varnishing completely with F class varnishing, applying expoxy coating, rewinding & reassembling, dynamically balancing the alternator transporting and fixing on frame and reallignment within tolerance limit , connecting the alternator with all connections and testing on load completely all as specified and as directed.
214M&L in repair/replacement, anti vibration mountingof DG Sets of capacity 40/62.5/100 KVA including connecting and testing all as specified and as directed.
215M&L in repair/replacement, battery Lead with Brass Terminals of DG Sets of capacity 40/82.5/125 KVA all as specified and as directed.
216M&L in repair/replacement, emergency shutdown switch with wiring of DG Set 40 KVA to 320 KVA all as specified and as directed.
217M&L in repair/replacement, fan belt of DG set 320/125/100 KVA all as specified and as directed.
218M&L in repair/replacement, fan belt of DG Set 82.5/62.5/50/40 KVA all as specified and as directed.
219M&L in repair/replacement, oil seal of DG Set 40 KVA to 320 KVA all as specified and as directed.
220M&L in repair/replacement, binjo bolt for pipe of DG Set 82.5/62.5/40 KVA all as specified and as directed.
221M&L in repair/replacement, fuel level float ball of DG Set 320/125 KVA all as specified and as directed.
222M&L in repair/replacement, radiator hose pipe set with clamps of DG Set 125/82.5/40 KVA all as specified and as directed.
223M&L in repair/replacement, air filter hose pipe set with clamps of DG Set 320/100/62.5/50 KVA all as specified and as directed.
224M&L in repair/replacement, dial type mechanical fuel level gauge meter of DG Set 125/82.5/40 KVA all as specified and as directed.
225M&L in repair/replacement, dial type mechanical water Temp gauge meter of DG Set 125/100/62.5/40 KVA all as specified and as directed.
226M&L in repair/replacement, dial type mechanical Volts gauge meter of DG Set 100/50/40 KVA all as specified and as directed.
227M&L in repair/replacement, coolant drum assembly of DG Set 320/125/100/40 KVA all as specified and as directed.
228M&L in repair/replacement, radiator fan metalic of DG Set 125/82.5/40 KVA all as specified and as directed.
229M&L in repair/replacement, radiator fan drive pulley of DG Set 125/82.5/40 KVA all as specified and as directed.
230M&L in repairs/replacement, hydraulic aluminium pipe for engine of DG Set 125/100/62.5/40 KVA all as specified and as directed.
231M&L in repair/replacement engine generator controller Model no GCU DSE 6120 suitable for DG set 320 KVA AMF panel all as specified and as directed.
232M&L in repair/replacement DIN Type Fuse Links Type HN Size 3, 500Amp, 415 V ~ 36.1 W allas specified and as directed. Make: L&T
233M&L in repair/replacement starter solenoid valve of DG Set 100/62.5/50//40 KVA all as specified and as directed.
234M&L in repair/replacement, starter / solenoid complete Assembly of DG Set 125/82.5/40 KVA all as specified and as directed.
235M&L in repair/replacement, Left/Right hand door locks with catcher.of DG Set 40KVA to 320 KVA all as specified and as directed.
236M&L in repair/replacement, engine generator controller Model no GCU 101 suitable for DG set 100 KVAAMF panel all as specified and as directed.
237M&L in repair/replacement, wrapping of rope on exhaust silencer completely DG Set 125/100/50/40 KVA all as specified and as directed.
238M&L for leakage rectification of radiator, cleaning, pressure testing etc for any make and capacity DG Set complete as required and directed.
239M&L in repair/replacement, battery charger 12 V DC SMPS 10 Amp for AMF panel all as specified and as directed.
240M&L in repair/replacement, battery charger 24 V DC SMPS 20 Amp for AMF panel all as specified and as directed.
241M&L in repair/replacement, engine generator controller as per existing model for AMF panel of DG Set 125/62.5/50/40 KVA all as specified and as directed.
242S&F in repair/replacement, 3 phase, 12-24V DC, charging alternator as per existing capacity suitable for DG Set 100/125/320 KVA all as specified and as directed.
243M&L for scraping, cleaning of old steel surface and painting with two coats of synthetic enamel paint over a coat of red oxide primer on DG set/EOT Crane of any Make & Capacity all as specified and as directed.
244M&L for bearing grease HP/BP type servo Gem Natra-3/Lithon-3all as specified and as directed.
245Comprehensive repair and maintenance of class II indoor duty double girderEOT cranes each of capacity of 5Ton,13 mtr Length installed in buildings located within in area of approx 10 Sq Km (MIC&S AREA)Note : Maintenance cost of each crane comprises of the following:- (i) Cost of tradesman and helper.(ii)Cost of Petty repairs and consumables such as cotton waste, "K" Oil, Grease, Nuts, Bolts washer etc.(iii)Cost of labour for fixing all the components, which needs replacement.(iv)Cost of labour for weekly, monthly, quarterly and annual maintenance in addition to other instructions given in Maintenance and operational manual of the manufacturer.
246All as per serial item No. 245 but capacity 5 Ton, 4 mtr Length
247Taking LT shutdown, dismantle and remove the EOT crane set, 5 Ton capacity, from existing foundation / position, shifting to authorized workshop for the repair work, removing the burnt winding, cleaning rotor / stator slots, re-winding the motor with super enameled copper wire of the size equivalent to the original winding including insulated packing materials, varnishing, heating, drying, gear oil,power contactors,breaks,steel ropes and spare kits and the cost of motor parts/ equpments etcetc, replacing star bush coupling,replacing the bearings, reassembling and installing back at it"s original position, aligning, testing and commissioning on full load for 8 hrs continuous running all as specified and as directed.
248S&F in repair/replacement, power contactor, 30 Amp, 440 Voltswith 110 volt coil for 5 Ton capacity EOT crane all as specified and as directed.
249S&F in repair/replacement, spare kit unit suitable forpower contactor, 30 Amp, 440 Voltswith 110 volt coilfor 5 Ton capacity EOT crane all as specified and as directed.
250S&F in repair/replacement, push button switches ON and Off inside the pendant/ panel board of5 Ton EOTcrane all as specified and as directed.
251S&F in repair/replacement, bimetallic overload relays, suitable for power contactor, 30 Amp, 440 Voltswith 110/230/440 volt coil all as specified and as directed.
252S&F in repair/replacement, flexible copper cablePVC insulated multi stranded of size 4 core 6 sqmm 1100 Volts grade ,ISI Markedcomplete all as specified and as directed.
253S&F in repair/replacement, flexible copper cable PVC insulated multi stranded of size 4 core 4 sqmm 1100 Volts grade, ISI Marked complete all as specified and as directed.
254S&F in repair/replacement, wheel with pin shaft all as specified and as directed.
255S&F in repair/replacement, ball bearing (Bearing No-6207) all as specified and as directed.
256S&F in repair/replacement, MS gear for wheel all as specified and as directed.
257S&F in repair/replacement, steel wire rope multi stranded 10mm dia all as specified and as directed. Make: Usha Martin
258S&F in repair/replacement, PVC coated & PVC Insulated copper conductor multistranded of size 10 sqmm 4 core all as specified and as directed.
259S&F in repair/replacement, HRC fuse link 32 amps as per site requirement all as specified and as directed.
260S&F in repair/replacement gear box oil EP-230 suitable for EOT cranes all as specified and as directed.
261M&L for brake oil all as specified and as directed.
262S&F in repair/replacement, brake shoe of 150mm dia all as specified and as directed.
263S&F in repair/replacement, magnetic coil all as specified and as directed all as specified and as directed.
264S&F in repair/replacement, limit switch, 3 phase, 415 volt, 50 Hz as per site requirement all as specified and as directed.
265S&F in repair/replacement, four pole contactor, AC three phase, 415volt Amps as per Site requirement all as specified and as directed.
266S&F in repair/replacement, carbon brushes for clutch for micro movement of EOT Crane all as specified and as directed.
267S&F in repair/replacement, current collector complete as per existing for EOT Crane of different capacity of EOT Crane all as specified and as directed.
268Taking LT shutdown, remove YASKAWA V1000 Inverter Drive (VFD), 3 phase In 400 volt AC complete and repair same and refix as per existing for EOT Crane all as specified and directed. Note: Replaced parts cost will be measured in this job.
269Supply only engine oil 15W40 of approved and standard in seal packed containers all as specified and as directed. Make : Servo/ BPL/IOC/ Castrol
270Supply only Greaves Lub Oil CI4 approved and standard in seal packed containers all as specified and as directed. Make : Greaves
271Supply only coolant of approved and standard in seal packed containers all as specified and as directed. Make:K cool Super plus 50-50 Premix, Castrol Radicool Premix, Greaves kool
272Supply only battery water with electrolyte mix all as specified and as directed.
273S&F in repair/replacement, of battery 12 V, Capacity XP1800 or180 AH, maintenance free battery, 12 Volt initially charged with suitable size of copper leads and brass terminals with 36 month warranty complete as directed by Engr-in-Charge. Make: Exide/ Amaron/ Luminous
274All as per serial item No 273 but capacity XP800 or 80 Ah
275Taking LT shutdown, complete checking of AMF panel, finding the fault, servicing complete including fixing in repair/replacement of unserviceable spares with necessary wiring and testing complete for manual & Auto operations all as directed. Note:- Items required for replacement will be measured & paid seperately as "Supply only" under respective item of BOQ
276Supply only AMF panel timer and over voltage timing relay as per existing type, make and capacity all as specified and as directed.
277Supply only AMF panel timer relay for circuit 230 V AC supply as per existing type, make and capacity all as specified and as directed.
278Supply only AMF panel relay card 12 V DC supply for change over as per existing type, make and capacity all as specified and as directed.
279Supply only AMF panel relay single with batch 8 pin 230 V AC supply as per existing type, make and capacity all as specified and as directed.
280Supply only selector switch with elements for controlling Auto/ Manual position of AMF panel of any make and capacity all as specified and as directed.
281Supply only Start/ Stop switch with elements of AMF panel of any make and capacity all as specified and as directed.
282Supply only solenoid switch for use of engine stop of AMF panel of any make and capacity all as specified and as directed.
283Supply only Volt meter digital type of range 0-500 volts of panel all as specified and as directed.
284Supply only Amp meter digital type of existing make,model and capacity of panel all as specified and as directed.
285Supply only Indicator lamp 230 V AC Supply of panel all as specified and as directed.
286Supply only AMF panel MCCB, 3 pole, 160 Amp, 16 KAall as specified and as directed.
287Supply only MCCB, 3 pole,125 Amp,16 KA all as specified and as directed.
288M&L in repairs/replacement, broken canopy door hinges and Glasses of any capacity DG set ofany capacity and make. Setting of conopy door, properly locking arrengement, welding Brazing of broken parts/body etc complete all as directed by Engr-in Charge
289M&L in repairs/replacement, for earthing complete with GI earth plate electrode of size 60cm x 60cm x 6.0m m burieddirectly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level sorrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt filling in alternate layers etc and connected to and including galvanized earth strip 25mmx4mmupto 7.5 m by means of bolts, nuts, check nuts and washers made of galvanised iron and protected by light grade 32mm dia GI pipe connected to main control board and GI pipe medium grade 20mm bore for watering and including funnel, wire mesh, charcoal,salt etcRCC pit cover flush to earth pit 50mm thick reinforced with 8mm TMT bar 100mmC/C and PCC chamber pit with PCC (1:3:6) type C1 (using 20mm graded aggregate)including excavation and earthwork disposal of surplus soil to distance not exceeding 50 metre) and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009 complete all as specified and as directed.
290S&F in repair/replacement, front mounting contactors 10 Amp, Type MNX-A1, 4 Poleall as specified and directed . Make : L&T
291S&F in repair/replacement, side mounting contactors, Type MNX-A6 or as per existing Left/Right side suitable capacity single Pole all as specified and directed . Make : L&T
292S&F in repair/replacement contactors MNX-A1,10 A or as per existing suitable capcacity four Pole all as specified and directed . Make : L&T
293S&F in repair/replacement, contactors MNX-A2,10 A or as per existing suitable capcacity two Pole all as specified and directed . Make : L&T
294S&F in repair/replacement, thermal overload relay 4P Model LRE 07 or as per existing suitable capcacity four Pole all as specified and directed . Make : L&T, Scnieder
295Supply only Illuminated Push Button assembly with Wire harnessexisting size and shape complete all as specified and as directed. Make : L&T/ Havells/AE
296Supply only Push Pull Turn Button assembly with Wire harnessexisting size and shape complete all as specified and as directed. Make : L&T/ Havells/AE
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail