Military Engineer Services-MES has published Tender For Certain Petty Repairs/Maintenance To Internal Electric Supply, Flame Proof Wiring And Connected Works In Atechnical Area At Dett Kargil And Af Stn Leh Under Ge(Af) Leh And Certain Petty Repairs/Maint To Internal Electrical Services In Do. Submission Date for this Tender is 11-05-2024. Electrification Work Tenders in Leh Jammu And Kashmir. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 04-May-2024 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 11-05-2024 |
Sl. No. | Item Description |
1 | Taking down carefully copper/Aluminium point wiring (Light,fan,socket or power) complete including fitting such as switches, socket, bell pushes, ceiling roses, pendants/batten holder, call bell, regulators etcall as specified and directed by Engr-in-charge. |
2 | M&L for point wiring for one light point controlled by one switch one way in & including PVC conduit or casing and capping as per site requirement using FRLS PVC unsheathed multistrand copper conductor cable 1.5 sqmm single core for one light/fan point/bell point controlled by one switch including 3 mm thick plastic laminated sheet cover over PVC / wooden Box for earth continuity insulated PVC unsheathed(green colour) 1.5 sqmm copper earth wire connected to common earth dolly using and making good to distrubed surfaces of wall/floor including matching the existing colour complete all as specified and directed by Engr-in-charge.Note : (a) wiring shall be done by using proper colour coding. |
3 | All as per srl item No. 02 here-in-before but for 05 Ampsocket outlet on indendent board complete all as specified. |
4 | All as per srl item No. 02 here-in-before but for 05 Ampsocket outlet on same board complete all as specified. |
5 | All as per item No02 above but for wall fan/exhaust fan point controlled by one way switch omplete all as specified. |
6 | All as per srl item No. 02 here-in-before but for 15 Ampindependent socket outlet using 2.5 sqmm ingle core wire complete all as specified. |
7 | S&F Switch piano, flush type 5 AmpsOne Way 230 volts complete all as specified. |
8 | S&F Socket outlet2-in-1 3 pin 6 & 16 Ampsflush type 230 volts complete all as specified. |
9 | S&F Socket outlet2-in-1 3 pin 6 Ampsflush type 230 volts complete all as specified. |
10 | S&F Switchone way 15 Ampsflush type 230 volts complete all as specified. |
11 | S&F Ceiling rose 3 terminal size 50x65mm surface type 230 volts complete all as specified. |
12 | S&F Holder insulated body with back plate for batten fitting suitable for LED lamp complete all as specified and directed by Engineer-in-Charge. |
13 | S&FCrystal glass LED tube light of1x20W, T8 ,4ft.(double side connection with LED driver) with very high efficacy suited for installation in existing tubelight G13 lamp holders to give glare free light includingcomplete all as directed by Engr-In-charge. |
14 | S&F universal Regal battenfor LED tube Double side connection Complete 1x22 Watt. |
15 | LED light fitting 1x20/22 watt, T-8, 4 ft box type, eppoxy powder coated CRCA sheet housing with reflector cover channel, prewired with 3 core copper cable of size 23/.0076 from ceiling rose to tube light fitting and tube rod of 20/22 watt fixed on wall/ceiling for surfaced pendant mounting in and including taking down of old unserviceable light fitting complete all as specified and directed by Engr-in-charge. |
16 | S&F LED Adore Lamp 9/10W, B22 base 6500K CDL typecomplete all as directed by Engr-In-charge. Make: Havells or Equivalent as approved by GE. |
17 | Material and labour for point wiring in steel conduit unsheathed multistrand copper conductor cable of 1.5 sqmm single core FRLS for one light/fan point controlled by one flame proof switch including continuouse earth continuity copper earth wire of same size connected to common earth dollycomplete all as specified and directed by Engr-in-charge.Note : (a) wiring shall be done by using proper colour coding. |
18 | S&F Switch flame proof rotary type with termination box in LM6, 16 Amps, single pole 250 volts.Make : Sudhir Switchgears or equivalent |
19 | S&F Flame proof SPN DB 4 way 240 V having200 A rated bus bars with 32 Amps SPN MCB-01 No and 16-32 Amps SP MCB"s - 02 Nos complete all as specified and directed by Engr-In-charge. Make : Sudhir Switchgears or equivalent. |
20 | S&F LED flameproof light fitting 1 x 20 Watts, CIMFR approved and recommended for gas/vapor group of IIA & IIB, Zone 1 & 2 and IP65 protection with die cast aluminium housing with heat resistant toughned glass with LED tube light fixtures, driver, holder, connector etc. complete with all accessories pre-wired and including connecting up with three core flexible copper conductor wire of suitable size complete all as specified and as directed by Engr-in-Charge. |
21 | S&F LED flameproof light fitting 2 x 20 Watts, CIMFR approved and recommended for gas/vapor group of IIA & IIB, Zone 1 & 2 and IP65 protection with die cast aluminium housing with heat resistant toughned glass with LED tube light fixtures, driver, holder, connector etc. complete with all accessories pre-wired and including connecting up with three core flexible copper conductor wire of suitable size complete all as specified and as directed by Engr-in-Charge. |
22 | M&L in replacement for Sub main wiring complete with FRLS PVC insulated unsheathed stranded copper conductor wire 2.5 Sq mm 02 Nos. (for Phase & Neutal)alongwith earth wire FRLS PVC insulated unsheathed stranded copper conductor wire of size 2.5 sq mm wire drawn through in & including PVC casing capingcomplete all as directed by Engr-In-charge. Note : (i) Two single core cable and one run of earth copper cable will be measured and paid as one unit length |
23 | All as per srl item No. 22 here-in-before but 4.0 Sqmm as in phase and neturalwith 4.0 sqmm as in earth wire complete all as specified. Note : (i) Two single core cable and one run of earth copper cable will be measured and paid as one unit length |
24 | All as per srl item No. 22 here-in-before but 6.0 Sqmm as in phase and neturalwith 6.0 sqmm as in earth wire complete all as specified. Note : (i) Two single core cable and one run of earth copper cable will be measured and paid as one unit length |
25 | Supply and fix PVC flat twin core unarmoured Aluminium cable of size 10 Sqmm all as specified anddirected by Engineer-in-Charge. |
26 | S&F MCB SPN 32A, 240 V -10 KA all as specified and as directed by Engineer-in-charge. |
27 | S&F MCB SP 6-32A, 240 V -10 KA all as specified and as directed by Engineer-in-charge. |
28 | Taking down old unserviceable main switches/ Distribution board any type including fuses MCB etc after removing all connection and making good the disturb surface allas directed by Engineer-in-charge. |
29 | S&F Sheet metal enclosure double door for DB"s SPN 8 way 240 V having200 A rated bus bar complete all as specified and directed by Engr-Incharge. |
30 | S&F Sheet metal enclosure double door for DB"s SPN 4 way 240 V having200 A rated bus bar complete all as specified and directed by Engr-In-charge. |
31 | S&F Sheet metal enclosure double door for DBs TPN 4 way 415 Volt having 200 A rated bus bar complete all as specified and directed by Engr-in-charge. |
32 | S&F MCB 63 Amp TPN415 volts 50 Hz 25 KA, complete with allaccessories as required on site & as directed by engineer-in-charge. |
33 | S&F blank plate to cover up the blank area of MCB in DBs as directed by engineer-in-charge. |
34 | S&F Energy saving new generation Endura Rugby Neo - IP65, 10WLED IP65 bulkhead luminaire with opal diffuser, etc complete with all accessories rewired electrically connected all as specified and directed by Engr-Incharge. |
35 | S&F ENDURA Slim Pro Plus PANEL 36W LED 5700K LED fittingwith LED prisumatic optival modular luminaire suitable for Reccessesmounting complete with HF electronic driver. |
36 | S&F modular switch 1 way 6A, 1 module,Large size complete |
37 | S&F modular socket 6A, 2/3 pin combined, 2 module |
38 | S&F modular socket 6A/16A, 2/3 pin combined, 2 module |
39 | Earthingcomplete with galvanised steel earth plate electrode 60x60cmx6mm thick, buried directly in ground (earth pit not less than 2.25meters deep below ground level) with top edge of the plate not less than 1.5meters below normal ground level, connected to GI wire 4 mm dia as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 5 connected to DBs all as specified and directed. |
40 | Taking down exhaust fan of any type for repair including rewinding of motor, replacement of parts like capacitor, bearing, bush, painting etc and refixing it to its original position after testing all as specified & as directed by Engineer-in-charge. |
41 | Rewinding of exhaust fan of any type or make but of size upto 250mm to 450mm sweep with copper winding wire of required size & type and replacement of bearing, bush and capacitor of required size complete all as required on size and all as directed by Engineer-in-charge. |
42 | S&F decorative garden light of 10 W with IP65 protection, Product description of Make Crompton product description LBLSR-10-WW or equivalent all as specified & directed by Engineer-in-Charge. |
43 | S&F decorative LED Post Top ideal to light of 20 W with IP65 protection, Product descriptionMake Crompton productLPTH-20-CDL or equivalent all as specified & directed by Engineer-in-Charge. |
44 | S&F decorative LED Post Top 360 degree light of 40 W with IP65 protection, resistant to impact, anti corrosion, glare-free and beffer uniformity. Product description of Make Crompton product description LPTO-40-WW or equivalent all as specified & directed by Engineer-in-Charge. |
45 | Attending thecomplaintsof electrification nature rectification of the fault as per the complaint lodged by the user onward KWH meter in respect of main distribution board having switch fused, MCB distribution board in sheet metal enclosure, point wiring fixture for light/fan/bell/light or power socket complete repairs to the extent by removing connections from the system removing faults in wires, battens, conduit, suck boxes, juction boxes, main switches, MCBs/DBs utility light fitting, lamp holders AC ceiling/exhaust fans and other connected fixtures of the internal electrification including providing of petty sotres such as wires of appropriate size and conductor matching to existing one upto the length of 1 mtr including insulation tap, screws, nuts as required to rectified the fault with regard to the complaint lodged and refixing of fittings, fixture to their position as dismantled complete all as directed at site to the entire satisfaction of Engr-in-charge/users . NOTE: (a) Items replaced shall be measured seprately. (b) All the necessary T&P and transport required for repair shall be provided by the contractor. (c)The complaints of internal electric of one qtr will be considered one Job. (d)The penaltyshallbe applicable to the contractor if the delay is noticed byEngineer-In Charge more than12 Hrs after handing over the work of urgent nature to the contractor.(e) Please not that this penaltyis exculsivelyother thanconditions 56 IAFW-2249 & shall be treated as interimconditionof the contract & Shallinforceable as andelayin individualjob is noticed & no cliam whatever on his account shallbe entertained by the dept. The decisionof the accepting officer in this regard shallbe final& binding. |
46 | Supply only MCB SPN 32A, 240 V -10 KA all as specified and as directed by Engineer-in-charge. |
47 | Supply only MCB SP 6-32A, 240 V -10 KA all as specified and as directed by Engineer-in-charge. |
48 | Supply only MCB 32 Amp TPN415 volts 50 Hz 25 KA, complete with allaccessories as required on site & as directed by engineer-in-charge. |
49 | Supply only MCB 63 Amp TPN415 volts 50 Hz 25 KA, complete with allaccessories as required on site & as directed by engineer-in-charge. |
50 | Supply only Sheet metal enclosure double door for DB"s SPN 8 way 240 V having200 A rated bus bar complete all as specified and directed by Engr-Incharge. |
51 | S&F Sheet metal enclosure double door for DB"s SPN 4 way 240 V having200 A rated bus bar complete all as specified and directed by Engr-In-charge. |
52 | Supplyonly Sheet metal enclosure double door for DBs TPN 4 way 415 Volt having 200 A rated bus bar complete all as specified and directed by Engr-in-charge. |
53 | Supply only Holder insulated body with back plate for batten fitting suitable for LED lamp complete all as specified and directed by Engineer-in-Charge. |
54 | Supply only Crystal glass LED tube light of18/20W T8 ,4ft.(double side connection with LED driver) with very high efficacy suited for installation in existing tubelight G13 lamp holders to give glare free light complete all as directed by Engr-In-charge. |
55 | Supply only universal Regal battenfor LED tube Double side connection Complete 1x22 Watt. |
56 | LED light fitting 1x20 watt, T-8, 4 ft box type, eppoxy powder coated CRCA sheet housing with reflector cover channel, prewired with 3 core copper cable of size 23/.0076 from ceiling rose to tube light fitting and tube rod of 18*20 watt fixed on wall/ceilingfor surfaced pendeant mounting in and including taking down of old unservicable fitting, complete all as specified anddirected by Engineer-in-Charge. |
57 | Supply only Switch piano, flush type 5 AmpsOne Way 230 volts complete all as specified. |
58 | Supply only Socket outlet2-in-1 3 pin 6 Ampsflush type 230 volts complete all as specified. |
59 | Supply only switch socket combination with PVC box 2-in-1 3 pin 6 & 16 Ampsflush type 230 volts complete all as specified. |
60 | Supply only switch socket combination with PVC box 2-in-1 3 pin 5 Ampsflush type 230 volts complete all as specified. |
61 | Supply only switch socket combination 2-in-1 3 pin 5 & 15 Ampsflush type 230 volts complete all as specified. |
62 | Supply only switch socket combination 2-in-1 3 pin 5 Ampsflush type 230 volts complete all as specified. |
63 | Supply only FRLS PVC insulated unsheathed stranded copper conductor wire single core of size 2.50 sqmm |
64 | Supply only FRLS PVC insulated unsheathed stranded copper conductor wire single core of size 4.00 sqmm |
65 | Supply only FRLS PVC insulated unsheathed stranded copper conductor wire single core of size 6.00 sqmm |
66 | Supply only hylem sheet cover 3mm thick of size 4" x 4" |
67 | Supply only hylem sheet cover 3mm thick of size 6" x 4" |
68 | Supply only hylem sheet cover 3mm thick of size 8" x 4" |
69 | Supply only PVC Casing & Caping of size 1.0"(ISI Marked)including all fixing accessories |
70 | Supply only PVC Casing & Caping of size 1.5" (ISI Marked) including all fixing accessories. |
71 | Note : Schedule of credit to be deducted on acceptances of bid.Details of Schedule of credit is given in tender documents |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail