}

Tender For For Various Electrification Work In Business Plan-2024-25 Under Various 33 / 11 Kv S / S Area Under Edd-Ii, Budaun, 1 The Work Of Safe Carriage Of The Following Material From Store Cen, Budaun-Uttar Pradesh

Madhyanchal Vidut Vitran Nigam Limited has published Tender For For Various Electrification Work In Business Plan-2024-25 Under Various 33 / 11 Kv S / S Area Under Edd-Ii, Budaun, 1 The Work Of Safe Carriage Of The Following Material From Store Cen. Submission Date for this Tender is 29-04-2024. Distribution Box Tenders in Budaun Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

43161086
Corrigendum : Tender For For Various Electrification Work In Business Plan-2024-25 Under Various 33 / 11 Kv S / S Area Under Edd-Ii, Budaun, 1 The Work Of Safe Carriage Of The Following Material From Store Cen
Open Tender
Indian
Uttar Pradesh
Budaun
29-04-2024

Tender Details

Tender For Various Electrification Work In Business Plan-2024-25 Under Various 33 / 11 Kv S / S Area Under Edd-Ii, Budaun, 1 The Work Of Safe Carriage Of The Following Material From Store Center Nawada To Work Site Under The Jurisdiction Of Edd-Ii, Budaun Approx. Distance Upto 0-50 Km. Including Safe Loading And Unloading. 2 11 Kv Vcb I / C 3 11 Kv Vcb O / G 4 33 Kv P.T. 5 33 Kv Fuse Set 6 33 Kv Lightening Arrestor 7 33 Kv Vcb O / D 8 33 Kv Control Pannel For Single Transformer 9 33 Kv Control Pannel For Double Transformer 10 33 Kv C.T., 400 / 200 / 1-1-1 Amp. 11 33 Kv Line Isolator 12 Battary Charger 24Volt 13 Battary Set 24Volt 14 Pcc Pole Support 8.5 Mtr. Long 15 11 Kv Disc Insulator Composite 45 Kn ( T&C Type ) 16 11 Kv Pin Insulator Composite 17 11 Kv X-Arm V Type 18 Acsr Rabbit Conductor 19 Stay Complete 20 Earthing Complete 21 Abc Cable ( 3X95+1X70+1X16 ) Sqmm 22 Abc Cable ( 3X120+1X70+1X16 ) Sqmm 23 3 Phase Distribution Box 24 G.I. Wire 10 Swg 25 Dismentaling Of Following Old & Damaged Equipment’Sas Per Norms Complete In All Respect 26 11 Kv Vcb I / C 27 11 Kv Vcb O / G 28 33 Kv P.T. 29 33 Kv Lightening Arrestor 30 33 Kv Vcb O / D 31 33 Kv Control Pannel For Single Transformer 32 33 Kv Control Pannel For Double Transformer 33 33 Kv C.T., 400 / 200 / 1-1-1 Amp. 34 33 Kv Line Isolator 35 Erection / Installation Of Following 11 Kv Panel ( Vcb ) In Control Room And Cable Joint Of The Panel To Pole Including Earthing, Grouting Of Anchor Bolt Of Panel And Making / Repairing Of Pocket For Cable To Insert In Panel From Trench And Fixing, Taping Of Bus Bar With Wiring For Pt. Ac, Dc Connection Including Providing Of Ac & Dc Supply. 36 11 Kv Vcb I / C 37 11 Kv Vcb O / G 38 Mounting And Installation Including Mechanical / Electrical Fixing And Adjusting Of The Following Equipment On Their Respective Structures Including Proper Adjustment As Per Resspo Norms. 39 33 Kv Vcb O / D 40 33 Kv P.T. 41 33 Kv Fuse Set 42 33 Kv Lightening Arrestor 43 33 Kv C.T., 400 / 200 / 1-1-1 Amp. 44 33 Kv Line Isolator 45 33 Kv Control Pannel For Single Transformer 46 33 Kv Control Pannel For Double Transformer 47 Battary Charger 24Volt 48 Battary Set 24Volt 49 Laying Of Control Cable From 33 Kv Panel To Vcb 2X2.5 Sqmm Aramourd Cable Under Ground In Trench Making Proper Complete In All Respect As Per Resspo Norms. 50 Laying Of Control Cable From 33 Kv Panel To Vcb 4X2.5 Sqmm Aramourd Cable Under Ground In Trench Making Proper Complete In All Respect As Per Resspo Norms. 51 Erection Of Single Pcc Pole 8.5 Mtr. Long In H.T / L.T Lines Including Fitting Of All Accessories As Per Resspo Norms ( All Necessary Clamps, Nut & Bolts Etc. Shall Be Provided By The Contractor For Execution Of Work As Per Resspo Norms ) . 52 Grouting Of Pcc Pole 8.5 Mtr. Long With 1:4:8 Mixture In Size ( 450X450x1500mm. ) Including Cost Of Cement / Bb & Sand Required As Per Resspo Norms. ( All Grouting Material Shall Be Provided By The Contractor ) . 53 Grouting Of Stays, 1:4:8 Cc Ratio ( 600X600x300mm. ) As Per Respo Norms. ( All The Grouting Material Shall Be Provided By The Contract For Execution Of Work ) . 54 The Work Of Driving The Earthing Electrode And Making Connections With Gi Wire. 55 Dismentaling Of Following Old & Damaged Line As Per Norms Complete In All Respect 56 Acsr Weasel Conductor 57 Abc Cable 58 Laying, Stringing, Sagging & Jumpring Of Following Conductor Complete In All Respect As Per Resspo Norms. 59 Acsr Rabbit Conductor 60 Abc Cable ( 3X95+1X70+1X16 ) Sqmm 61 Abc Cable ( 3X120+1X70+1X16 ) Sqmm 62 Errection And Commissioning Of 3 Phase Distribution Box On The Lt Poles ( All The Material Required Shall Be Arranged By The Contractor For Errection And Commissioning Of Distribution Boxes Except Distribution Box ) . 63 Guarding Of Ht / Lt / Telephone Line / Road / River Crossing Etc. And Making Net With Difference Of 1.00 Mtr. Completely Including Fixing Of All Channel / Angle Etc. With Proper Locking At Each Support. All Type Nut & Bolt Shall Be Provided By The Contractor. 64 Repairing And Overhauling Of 33 Kv Vcb 65 Providing And Fixing Of Damaged Charging Garai And Non-Bearing Complete For 33 Kv 66 Complete Repairing Of Tripping Machanish System And Replacement Of Lever, Spring, Bush Etc For 33 Kv Vcb 67 Providing And Fixing Of 03 No. Eye Bolt And Contactor 33 Kv Vcb 68 Providing And Fixing Of Handing And Pumping Relay For 33 Kv Vcb 69 Complete Repairing Of 3 Kv Vcb Motor And Garari Complete For 33 Kv Vcb 70 Providing And Fixing Of Damaged Triping Coil Complete For 33 Kv Vcb 71 Providing And Fixing Of Fiber Closing Rodfor 33 Kv Vcb 72 Providing Of 2.5 Mmsq. Pvc Copper Wire And Repairing Of Damaged Burnt Wiring Complete Of 33 Kv Vcb 73 Complete Overhauling, Proper Connection And Providing And Fixing Of Missing Nut & Bolts And Proper Functioning Of 33 Kv Vcb 74 Repairing And Overhauling Of 33 Kv Control Panel 75 Providing & Fixing Of Local Remote Switch For 33 Kv Control Panel 76 Providing & Fixing Of Indicator Lamp 06 No. Of Different Colour And Proper Connections 77 Providing & Fixing Of 63 Amp. Kit-Kat With Tubular Fuse 08 Nos. Complete And Proper Connection 78 Complete Repairing Proper Connection And Providing Of Missing Nut & Bolts For Proper Functioning Of 33 Kv Control Panel 79 Providing And Laying Of 4X2.5 Mmsq. Control Cable From 33 Kv Vcb To 33 Kv Control Panel Under Ground In Trench Making Proper 80 The Following Decentralized Material Shall Be Provided By The Contractor For Execution Of Work As Per Respo Norms ( The Material Shall Be Purchased From Approved Vendor Of Discom ) . 81 11 Kv F Clamp With Nut & Bolt 82 X-Arm Holding Clamp With Nut & Bolt 83 Stone Pad 84 Distribution Box Clamps 85 Lt Shackle Insulator 86 N&B For Shackle Insulator 87 Lt Clamps With N&B For Shackle Insulator 88 Stay Insulator 89 11 Kv Guarding Angle Of Size 65X65x6 Mm 90 Control Cable From 33 Kv Panel To Vcb 2X2.5 Sqmm Aramourd 91 Control Cable From 33 Kv Panel To Vcb 4X2.5 Sqmm Aramourd 92 Safe Back Carriage Of Following Item ( If Any ) From Work Site To Store Center, Nawada, Budaun Approx Distance Upto 0-50 Km Including Loading & Unloading. 93 Material Jarjar Weasal Conductor 94 Old Battery Damage 95 Material Abc Scrap 96 33 Kv Vcb O / D Damage 97 Old Damaged Ct / Pt 98 33 Kv Control Panel Damage 99 11 Kv Vcb O / D Damage 100 33 Kv Line Isolator Scrap 101 33 Kv Lightening Arrestor.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 18-Apr-2024 DATE EXTENSION3 Date 22-04-2024
2 23-Apr-2024 DATE EXTENSION03 Date 26-04-2024
3 27-Apr-2024 DATE EXTENSION4 Date 29-04-2024

Key Value

Document Fees
INR 3540 /-
EMD
INR 17000.0 /-
Tender Value
INR 16.93 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail