Tender For Annual Rate Contract For Repairs And Maintenance Of 33/ 11 Kv Receiving Stationsfalling Under The Jurisdiction Of Sub Transmission Division (District Doda And Kishtwar) For The Year 2024-25 Or Till Next Rate Contract Under The Jurisdiction Of, Jammu-Jammu And Kashmir

Jammu And Kashmir Power Development Department-PDDJK has published Tender For Annual Rate Contract For Repairs And Maintenance Of 33/ 11 Kv Receiving Stationsfalling Under The Jurisdiction Of Sub Transmission Division (District Doda And Kishtwar) For The Year 2024-25 Or Till Next Rate Contract Under The Jurisdiction Of. Submission Date for this Tender is 30-04-2024. Wire Fencing Tenders in Jammu Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

43152169
Tender For Annual Rate Contract For Repairs And Maintenance Of 33/ 11 Kv Receiving Stationsfalling Under The Jurisdiction Of Sub Transmission Division (District Doda And Kishtwar) For The Year 2024-25 Or Till Next Rate Contract Under The Jurisdiction Of
Open Tender
Indian
Jammu And Kashmir
Jammu
30-04-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Annual Rate Contract For Repairs And Maintenance Of 33 / 11 Kv Receiving Stationsfalling Under The Jurisdiction Of Sub Transmission Division ( District Doda And Kishtwar ) For The Year 2024-25 Or Till Next Rate Contract Under The Jurisdiction Of Executiveengineer, Std Doda, Jpdcl Jammu.-- 1 Dismantling Of 2 11Kv Vcb Panel Complete 3 33Kv C&R Panel Complete 4 33Kv Vcb / Mocb Complete 5 Installation, Testing And Commissioningof Switchgear System Complete ( Material To Be Provided By The Department ) 6 11Kv Vcb Panel Complete 7 33Kv C&R Panel Complete 8 33Kv Vcbcomplete 9 Supply, Installation, Testing And Commissioning Of Fresh 11Kv C.T By Way Of Replacement Of Damaged / Burnt Out 11 Kv C.T Of Same Ratio, Type, Make And Class Already Installed In Panel Confirming To Iec 60044-1-2000 Standards Suitable For 11Kv Vcb Allind Panels 10 Supply, Installation, Testing, Commissioning Of Fresh 11Kv C.T By Way Of Replacement Of Damaged / Burnt Out 11 Kv C.T Of Same Ratio, Type, Make And Class Already Installed In Panel Confirming To Iec 60044-1-2000 Standards Suitable 11Kv Vcb Panels Of Makeeason Reyrol / Vijay 11 Installation, Testing And Commissioning Of Fresh 11Kv C.T By Way Of Replacement Of Damaged / Burnt Out 11 Kv C.T Of Same Ratio, Type, Make And Class Already Installed In Panel ( Material To Be Provided By The Department ) ( For 11Kv Vcb Panels ) 12 Supply, Installation, Testing And Commissioning Of 11Kv P.T By Way Of Replacement Of Damaged / Burnt Out 11 Kv P.T Of Same Ratio, Type, Make And Class Already Installed In Panel Confirming To Iec 60044-1-2000 Standards ( For 11Kv Vcb Panels ) Outdoor Type 13 Supply, Installation, Testing And Commissioning Of 11Kv P.T By Way Of Replacement Of Damaged / Burnt Out 11 Kv P.T Of Same Ratio, Type, Make And Class Already Installed In Panel Confirming To Iec 60044-1-2000 Standards ( For 11Kv Vcb Panels ) Indoor Type 14 Installation, Testing And Commissioning Of Fresh 11Kv P.T By Way Of Replacement Of Damaged / Burnt Out 11 Kv P.T Of Same Ratio, Type, Make And Class Already Installed In Panel ( Material To Be Provided By The Department ) ( For 11Kv Vcb Panel ) Outdoor Type 15 Installation, Testing And Commissioning Of Fresh 11Kv P.T By Way Of Replacement Of Damaged / Burnt Out 11 Kv P.T Of Same Ratio, Type, Make And Class Already Installed In Panel ( Material To Be Provided By The Department ) ( For 11Kv Vcb Panel ) Indoor Type 16 Providing And Fixing Offresh Male Contact Setfor Following 11Kv Vcb By Way Of Replacement Of Damaged / Burnt Outmale Contact Setof Same Composition, Type, Make And Class Already Installed In 11Kv Vcb Panel 17 Alsthommake 18 Easun Reyroll Make 19 Vijay Make 20 Sudhir Make 21 Electric Field 22 Crompton Greeves 23 Allind 24 Abb Make 25 Providing And Fixing Offemale Contact ( Complete Assembly ) For 11Kv Vcb By Way Of Replacement Of Damaged / Burnt Outfemale Contact Setof Same Composition, Type, Make And Class Already Installed In 11Kv Vcb Panel 26 Alsthommake 27 Easun Reyroll Make 28 Vijay Make 29 Sudhir Make 30 Electric Field 31 Crompton Greeves 32 Allind 33 Abb Make 34 Providing And Fixing Of 11Kv Vacuum Interrupter By Way Of Replacement Of Damaged / Burnt Out 11Kv Vacuum Interrupter Of Same Composition, Type, Make As Already Installed In 11Kv Vcb Panel ( 1250Amps ) 35 Fixing Of Fresh 11Kv Vacuum Interrupter By Way Of Replacement Of Damaged / Burnt Out 11Kv Vacuum Interrupter Of Same Composition, Type, Make Already Installed In 11Kv Vcb Panel ( Material To Be Provided By The Department ) 36 Supply, Installation, Testing And Commissioning Of Numerical / Digital Relayby Way Of Replacement Of Damaged / Burnt Of Same Ratio ( A.C &D.C ) , Type, Make And Class Already Installed In Panel. All Relays Shall Conform To The Requirements Of Is:3231 / Iec-60255 And Iec-61850 Of ( Mit113 Er / Ashida 141A ) Operating Voltage 30-36Volts 37 Fixing , Testing And Commissioning Of Numerical / Digital Relay ( Mit113 / Ashida 141A ) By Way Of Replacement Of Damaged / Burnt Of Same Ratio ( A.C &D.C ) , Type, Make And Class Already Installed In 11Kv Vcb Panel. ( Material To Be Provided By The Department ) 38 Rectification, Re-Alignment, Setting Right The Electricalsection Of 11Kv Breakers ( 11Kv Vcb Panel ) 39 Rectification, Re-Alignment, Setting Right The Mechanicalsection Of 11Kv Breakers ( 11Kv Vcb Panel ) 40 Rectification, Re-Alignment, Setting Right The Electrical Section Of 33Kv C&R Panel 41 Rectification, Re-Alignment, Setting Right The Mechanical Section Of 33Kv Vcb 42 Replacement Of Spring Charging Motor Of 33 Kv Vcb 43 Supply, Installation, Testing, Commissioning Of Damaged Clamps ( A.A ) Confirming To Is:617 Standards ( For 33Kv Vcb, 33Kv L.A, 33Kv Isolator ) With Fresh One Complete. 44 Supply, Installation, Testing, Commissioning Of Tripping / Closing Coils Suitable For 11Kv Vcb Panels Like Allind, Vijay, Crompton Greeves, Easun Reyroll, Alasthom, Electricfield, Sudhir, Abb, L&T Etc 45 Providing And Fixing Of Clamps ( Bi-Metallic ) Confirming To Is: 1285 Standards ( For 33Kv P.T Clamps, C.T Clamps, Transformer Clamps ( Both H.V & L.V Side ) , Pad Clamps ) 46 Providing And Fixing Of 33Kv Post Insulatorsby Way Of Replacement Of Damaged One Confirming To Iec 61109 / 92-93 With Latest Amendments ( Porceline Type ) 47 Providing And Fixing Of 33K Vcb Bushes Complete Assembly By Way Of Replacement Of Damaged One Confirming To Is:2099 Standard ( Porceline Type ) 48 Providing And Fixing Of 33Kv Hv Bushes Of Power Transformers Complete Assembly By Way Of Replacement Of Damagedoneconfirming To Is:2099 Standards ( Porceline Type ) 49 Providing And Fixing Of 11Kv Lv Bushes Of Transformers Complete Assembly By Way Of Replacement Of Damaged One Confirming To Is: 2099 Standards ( Porceline Type ) 50 Supply, Installation, Testing And Commissioning Of Fresh 33Kv C.T ( 3-Core ) Confirming To Iec:185 And Is:2705 ( Part-1 To 4 ) Standardsof Ratio 300-150 / 5-5-5A / 250-125 / 5-5-5A ) Outdoor Type 51 Fixing, Installation, Testing And Commissioning Of Fresh 33Kv Ct ( 3-Core ) Of Different Ratio. 52 Supply, Installation, Testing And Commissioning Of33kv P.Tof ( 110V / V3 ) Confirming To Is:3156 ( Part-I To Part-Iii ) Outdoor Type 53 Fixing, Installation, Testing And Commissioning Of Fresh 33Kv Pt ( 110V / V3 ) 54 Providing And Fixingof 33Kv Isolator 1250 Amps Heavy Duty Confirming To Is:9921 / Iec-62271-102 Standards 55 With Earthing Blade 56 Without Earthing Blade 57 Fixing, Installation, Testing And Commissioning Of Fresh 33Kv Isolators 58 Supply. Installation, Testing And Commissioning Of 33Kv Link Set ( 610X50x6mm Male Copper Balde And Female Part 200X50x3mm ) By Way Of Replacement Of Damagedoneheavy Duty 600Amps. 59 Installation, Testing And Commissioning Of 33Kv Link Set 60 Supply, Installation, Testing And Commissioning Of 11Kv G.Oset 850 Amps ( With Earthing Blade ) Heavy Duty Conforming To Latest Version Of Is - 9921 ( Part-I To V ) With Earthing Blade By Way Of Replacement Of Damaged One 61 Installation, Testing And Commissioning Of 11Kv G.Oset 62 Providing, Fixing, Installation, Testing And Commissioning Of 11Kv Isolators, 600Amps. Conforming To Is 9921 / Iec-129 Standards 63 With Earthing Blade 64 Without Earthing Blade 65 Installation, Testing And Commissioning Of 11Kv Isolators, 66 Supply, Installation, Testing And Commissioning Of 11Kv Link Set ( 400X50x6mm Male Copper Balde And Female Part 100X50x3mm ) By Way Of Replacement Of Damagedoneheavy Duty 600Amps. 67 Installation, Testing And Commissioning Of 11Kv Link Set 68 Supply, Installation, Testing And Commissioning Of 33Kv Drop Out Setwith Porcelaine Insulatorby Way Of Replacement Of Damaged One As Per Latest Is Standard With Latest Amendments Thereof. 69 Installation, Testing And Commissioning Of 33Kv D.O. Set By Way Of Replacement Of Damaged One 70 Supply, Installation, Testing And Commissioning Of 33Kv L.A. Set ( Porcelaine Type With Clamps ) By Way Of Replacement Of Damaged One As Per Latest Is Standard With Latest Amendments Thereof. 71 Installation, Testing And Commissioning Of 33Kv L.A. Set By Way Of Replacement Of Damaged One . 72 Oil Toping In 33 / 11 Kv Power Transformersand 33Kv MocbS ( Transformer Oil To Be Supplied By The Department ) 73 Supply, Installation, Testing And Commissioning Of Winding Temperature Meter By Way Of Replacement Of Damaged One Suitable For 33 / 11 Kv, 10Mva / 6.3Mva / 5.0Mva Power Transformers 74 Supply, Installation, Testing And Commissioning Of Oil Temperature Meter By Way Of Replacement Of Damaged One Suitable For 33 / 11 Kv , 10Mva / 6.3Mva / 5.0Mva Power Transformers 75 Providing And Fixing Ofinterrupting Chambers ( Housing Assembly ) Suitable For 11Kvvcbof Different Make By Way Of Replacement Of Damaged One 76 Crompton Greeves 77 S&S 78 Vijai 79 Bhel 80 Alasthom 81 Easun Rey Roll 82 Electric Field 83 Supply, Installation, Testing And Commissioning Of Arcing Interrupting Chamberssuitable For33 Kvvcb Panels Of Different Make By Way Of Replacement Of Damaged One 84 Supply, Installation, Testing And Commissioning Ofspouts Bushing Suitable For 11Kvvcb ( Allind-Make ) Panel Of Different Make By Way Of Replacement Of Damaged One 85 Supply, Installation, Testing And Commissioning Ofspouts Bushing Suitable For 11Kvvcb ( Alasthom / Easun Reyroll / Vijay / Sudhir / Electric Field / Crompton Greeves / Abb-Make ) Panel Of Different Make By Way Of Replacement Of Damaged One 86 Supply, Installation, Testing And Commissioning Of Bush Rods Suitable For 33 / 11Kvpower Transformer ( 10Mva / 6.3Ma / 5.0Mva ) By Way Of Replacement Of Damaged One 87 33Kv Side 88 11Kv Side 89 Supply , Installation, Testing And Commissioning Of 30V, 100 Ah Maintenance Free Battery Bank ( Comprising Of 15 Number Battery Cells Of 2Volt Each ) Complete With Rack , Connectors Etc Conforming To Iec60896-21 / 22 Standards Of Exide / Hbl / Amar Raja Or Equivalent Make 90 Supply, Installation, Testing And Commissioning Of Automatic 30V, Float-Cum-Boost Charger With Full Waverectification For 220 V, 1Phase, 50 Hz Ac Input Supply . Copper Wound Suitable For 100 To 200 Ah 91 Supply , Installation, Testing And Commissioning Of 2V, 100 Ah Maintenance Free Battery Cell 92 Replacement Of Damaged 2V, 100 Ah Maintenance Free Battery Cell ( Dry Type ) To Be Provided By The Department 93 Supply, Laying, Testing, Commissioning Of 11Kv ( E ) Grade Armoured , 3-Core, Xlpe Power Cable ( With Stranded Compact Circular Aluminium With Extruded Semi Conducting Compound, Xlpe Insulated And Overall Pvc Sheathed Cable Confirming To Is:7089 ( Part-Ii ) -1985 With The Latest Amendments By Way Of Replacing The Damaged Cable Of 11Kv Switchgear ( Havells Or Glastor Or Finolex Make ) 94 630Mm^², 3-Core 95 400Mm^², 3-Core 96 300Mm^², 3-Core 97 240Mm^², 3-Core 98 185Mm^², 3-Core 99 150Mm^², 3-Core 100 120Mm^², 3-Core 101 Laying, Testing, Commissioning Of 11Kv ( E ) Grade Armoured , 3-Core, Xlpe Power Cable 102 630Mm^², 3-Core 103 400Mm^², 3-Core 104 300Mm^², 3-Core 105 240Mm^², 3-Core 106 185Mm^², 3-Core 107 150Mm^², 3-Core 108 120Mm^², 3-Core 109 Supply, Laying, Testing, Commissioning Of 11Kv ( E ) Grade Armoured , 1-Core, Xlpe Power Cable ( With Stranded Compact Circular Aluminium With Extruded Semi Conducting Compound, Xlpe Insulated And Overall Pvc Sheathed Cable Confirming To Is:7089 ( Part-Ii ) -1985 With The Latest Amendments By Way Of Replacing The Damaged Cable Of 11Kv Switchgear ( Havells Or Glastor Or Finolex Make ) 110 630Mm^², 1-Core 111 400Mm^², 1-Core 112 300Mm^², 1-Core 113 240Mm^², 1-Core 114 185Mm^², 1-Core 115 150Mm^², 1-Core 116 120Mm^², 1-Core 117 Laying, Testing, Commissioning Of 11Kv ( E ) Grade Armoured , 1-Core, Xlpe Power Cable 118 630Mm^², 1-Core 119 400Mm^², 1-Core 120 300Mm^², 1-Core 121 240Mm^², 1-Core 122 185Mm^², 1-Core 123 150Mm^², 1-Core 124 120Mm^², 1-Core 125 Supply, Laying, Testing, Commissioning Of 2.5 Sqmm Control Cable Armored , Copper Conductor Sheathedpvc Insulated Multi Colour Voltage Grade 1.1 Kv Conforming To Is:1554 ( Part 1 ) , Is 8130, Is ;5831 ( Havells Or Gloster Or Finolex Make ) 126 2 Core 127 4 Core 128 6 Core 129 8 Core 130 12 Core 131 Laying, Testing, Commissioning Of 2.5 Sqmm Control Cable 132 2 Core 133 4 Core 134 6 Core 135 8 Core 136 12 Core 137 Supply, Installation, Testing, Commissioning Of 11Kv , 3 Core Heat Shrinkablestraight Through Jointing Cable Kit ( Outdoor Type ) Suitable For Already Installed 11Kv Xlpe Power Cable Confirming To Is:13573 / 1993With Latest Ammendments If Any ( 3M Or Raychem Make ) 138 630Mm^², 3-Core 139 400Mm^², 3-Core 140 300Mm^², 3-Core 141 240Mm^², 3-Core 142 185Mm^², 3-Core 143 150Mm^², 3-Core 144 120Mm^², 3-Core 145 Installation, Testing, Commissioning Of 11Kv , 3 Core Heat Shrinkablestraight Through Jointing Cable Kit ( Outdoor Type ) 146 630Mm^², 3-Core 147 400Mm^², 3-Core 148 300Mm^², 3-Core 149 240Mm^², 3-Core 150 185Mm^², 3-Core 151 150Mm^², 3-Core 152 120Mm^², 3-Core 153 Supply, Installation, Testing And Commissioning Of 11Kv Cable Terminationkits ( Outdoor Type ) 3M Or Raychem 154 630Mm^², 3-Core 155 400Mm^², 3-Core 156 300Mm^², 3-Core 157 240Mm^², 3-Core 158 185Mm^², 3-Core 159 150Mm^², 3-Core 160 120Mm^², 3-Core 161 Installation, Testing And Commissioning Of 11Kv Cable Terminationkits 162 630Mm^², 3-Core 163 400Mm^², 3-Core 164 300Mm^², 3-Core 165 240Mm^², 3-Core 166 185Mm^², 3-Core 167 150Mm^², 3-Core 168 120Mm^², 3-Core 169 Supply, Installation, Testing, Commissioning Of 11Kv , 1 Core Heat Shrinkablestraight Through Jointing Cable Kit ( Outdoor Type ) Suitable For Already Installed 11Kv Xlpe Power Cable Confirming To Is:13573 / 1993With Latest Ammendments If Any ( 3M Or Raychem Make ) 170 630Mm^², 1-Core 171 400Mm^², 1-Core 172 300Mm^², 1-Core 173 240Mm^², 1-Core 174 185Mm^², 1-Core 175 150Mm^², 1-Core 176 120Mm^², 1-Core 177 Installation, Testing, Commissioning Of 11Kv , 1 Core Heat Shrinkablestraight Through Jointing Cable Kit ( Outdoor Type ) Suitable For Already Installed 11Kv Xlpe Power Cable 178 630Mm^², 1-Core 179 400Mm^², 1-Core 180 300Mm^², 1-Core 181 240Mm^², 1-Core 182 185Mm^², 1-Core 183 150Mm^², 1-Core 184 120Mm^², 1-Core 185 Supply, Installation, Testing And Commissioning Of 11Kv Cable Terminationkits ( Outdoor Type ) 3M Or Raychem 186 630Mm^², 1-Core 187 400Mm^², 1-Core 188 300Mm^², 1-Core 189 240Mm^², 1-Core 190 185Mm^², 1-Core 191 150Mm^², 1-Core 192 120Mm^², 1-Core 193 Installation, Testing And Commissioning Of 11Kv Cable Terminationkits 194 630Mm^², 1-Core 195 400Mm^², 1-Core 196 300Mm^², 1-Core 197 240Mm^², 1-Core 198 185Mm^², 1-Core 199 150Mm^², 1-Core 200 120Mm^², 1-Core 201 Unloading Of Material Which Are To Be Handled With Care Like 33Kv Ct / 33Kv Pt Etcincluding Manual Carriage From Dumping Site Upto Proper Stacking 202 Loading Of Of Material Which Are To Be Handled With Care Like 33Kv Ct / 33Kv Ptetc Including Manual Carriagestacking Site Upto Loading 203 Manual Carriage Of Materials Like 33Kv Ct / 33Kv Pt 33Kv C&R Panel , 33Kv Vcb Panel , 11Kv Vcb Panel Etc 204 Upto First 100Mtr Lead 205 For Every Additional 50Mtr Or Part There Off 206 Unloading Of Bulky Material Which Are To Be Handled With Care Like 33Kv C&R Panel , 33Kv Vcb Panel , 11Kv Vcb Panel Etc Including Manual Carriage From Dumping Site Upto Proper Stacking 207 Loading Of Bulky Material Which Are To Be Handled With Care Like 33Kv C&R Panel , 33Kv Vcb Panel , 11Kv Vcb Panel Etc Including Manual Carriagestacking Site Upto Loading 208 Supply , Installation, Testing And Commissioning Of Copper Bus Bar 209 Installation, Testing And Commissioning Of Copper Bus Bar 210 Repairing / Replacement Of 11Kv VcbS 211 Trippingandclosing Mechanism Repair 212 Trippingandclosing Mechanism Replacement 213 Re-Setting Links 214 Replacement Of Operating Shaft 215 Shower Contact 216 Isolating Sockets 217 Replacement Of Damaged Gears Complete Set 218 High Tension Spring 219 Tripping Shaft 220 Rollers 221 Latch Assembly 222 Replacement Of Copper Shims 223 Replacement Of Spring Charging Motor 224 Deco Spray Painitng 225 Installation, Testing And Commissioning Of Power Transformer Of Capcity ( 4 Mva / 5Mva / 6.3 Mva / 10Mva ) Complete Job Including All Neceesary Testing At Site 226 Dismanteling Of Power Transformer Of Capcity ( 4 Mva / 5Mva / 6.3 Mva / 10Mva ) Complete Job 227 Supply, Fixing, Testing And Commissioning Of 100 Amp 3 Pole Thermal Magnetic MccbS Having Adjustable Thermal ( 0.8 In-1.0 In ) .With Fixed Magnetic Setting Of 10*In, Breaking Capacity Not Less Than 36 Ka ( Ics=Icu=100% ) , With Spreader Links, Phase Barriers, & Direct Mounting Rotary Operating Mechanism ( Rom ) . The Rom Shall Be Lockable In Off Position. The Mccb Should Be Ce Marked And Shall Conform To Iec:60947-2-2003 Standards. The Mccb Shall Have A Maximum Operational Voltage ( Use ) 690V, Insulation Voltage ( Ui ) 1000V, And Impulse Withstand Voltage ( Uimp ) 8Kv. Mccbs Shall Be Actuated By A Rotary-Handle That Clearly Indicates The Three Distinctive Positions: On, Off And Tripped, Total Opening Time <10Msec, Mechanical Life 25000 Operations & Electrical Life @415V Ac 10000 Operations.Abb / Eaton / L&T / Schneider / Seimens / Legrand / Havells Make 228 Supply, Laying, Testing And Commissioning Of 50 Mm Sq 4Core 1.1 Kv Grade , Stranded Aluminium Conductor, Xlpe Insulated Pvc Outer Sheathed, Armoured Cable Frls ( HavelS / Gloster / Paramount / Grandlay ) As Per Is-7098 Amended Up To Date 229 Earthing Using 40Mm Gi Pipe Or 20Mm Gi Rode, 2.5 Mtr Long Complete As Per Rec Standard And Connection With Near By Mesh Using Gi Strip Of 50*6Mm. 230 Supply Installation Testing And Commissioning Of 33Kv Vcb ( 36 Kv , 1250 Amp, 26.2 Ka, Outdoor Type ) With All Accessories Mounting Standard And Foundation With Foundation Bolts As Per Rec Standard. 231 Supply Installation Testing And Commissioning Of33kv C&R Panel Along With O / C, E / F And Differential Relays, ( Iec 61850 ) , Mimic Diagram, Volt Meter, Ammeter, Annun Ciation Windows With Annunciation Relays, 3Phase Triviocter Meter 5Amp Dlms Complaint With Rs485 Port With Auxiliary Relays And Semaphore. 232 Supply Installation Testing And Commissioning11kv Vcb Panel Board With Breaker ( 12Kv, 1250 Amp, 25Ka, Indoor ) Along With O / C, E / F ( Iec61580 ) , Mimic Diagram, Volt Meter, Ammeter, Annun Ciation Windows With Annunciation Relays, 3Phase Triviocter Meter 5Amp Dlms Complaint With Rs485 Port With Auxiliary Relays And Semaphore. ( Incomer ) ( 400-800Amp Ct ) 233 Supply Installation Testing And Commissioning11kv Vcb Panel Board With Breaker ( 12Kv, 1250 Amp, 25Ka, Indoor ) Along With O / C, E / F ( Iec61580 ) , Mimic Diagram, Volt Meter, Ammeter, Annun Ciation Windows With Annunciation Relays, 3Phase Triviocter Meter 5Amp Dlms Complaint With Rs485 Port With Auxiliary Relays And Semaphore. ( Outgoing ) ( 400-800Amp Ct ) 234 Providing And Laying Of Cement Concrete Using 1:2:4 Ration For Foundations / Pole Bottoming Etc. ( Job Include Execution , Stone Soling And Formwork Above Ground Includingplaster Using 1:4 Ratio. 235 Providing, Cutting, Bending And Fixing Usingbinding Wire Of Tor Steel Twisted Tmt Bars Of Sizes. ( 16Mm, 12Mm, 10Mm And 8Mm ) 236 Supply Installation Testing And Commissioning Of 12 Volt Battery 180 Ah ( Exide, Amron, Microtex, Luminous ) Warranty To Be Provided As Per CompanyS Time. 237 Installation Testing And Commissioning Of 12 Volt Batteries 180 Ah 238 Providing And Fixing Of Yard Lights Of 50 / 60 W Watt 239 Providing And Fixing Of Gi Iron Of Sorts Design And Specification As Per Site Requirements 240 Cutting Bending Welding Drilling And Fising Of Gi / M.S Iron Of Sorts As Per Site Requirement 241 Sitc Of 36 Volt 2.5 Kva Invertor ( Dsp Base ) Latest Invertor. 242 Sitc Of 30 Kv Lightening Arrestors ( 30 Kv, 10Ka, Station Class, Zno, Polymer ) Gap Less 243 Repair Of 36 / 30Volt Battery Chargers 244 Replacement Of Damaged Dc Volt Meter With A Fresh Piece. 245 Replacement Of Damaged Dc Ampere Meter With A Fresh Piece. 246 Replacement Of 30 Ampere Rotor Switch 8 Way 247 Replacement Of Led Light 2Windication Round Type 248 Replacement Of Damaged Mcb 6 / 10 / 16 Ampere With A Fresh Piece 249 Replacement Of Damaged3 Pin Top 15 Amperewith A Fresh Piece 250 Replacement Of Damaged Wire / Lead 2.5Mm2 Dc Wire With A Fresh 251 Replacement Of Charger Cabinet With A New Cabinet 252 Rewinding Of Charger Coil With 7 No Copper Gauge 3” Wide 253 Full Rewinding Of Battery Charger Including Extra Core , 30Ampere Rotor With Full Wave Rectifier 60Ampere ( 4 Pcs ) With Heat Sinkwith Ampere Meter 254 Replacement Of Damaged Rectifier 60Ampere ( 4 Pcs ) Complete With Board 255 Replacement Of Burnt Out Droppers / Jumpers In Switchyard 256 Setting Right Of 33 Kv Isolators 257 Setting Right Of 11 Kv Isolators 258 Cleaning Of 11 Kv Panels, Ac / Dc Boards, 33 Kv Cnr Panels 259 Repairing Of Auxialiary Transformers By Way Of Replacement Of Damaged Bushes, Bush Rods Thimbles Etc. 260 Sitc For Replacement Of Damaged Auxiliary Transformers By New One Of 63 Kva ( Level-Ii ) 261 Replacement Of Damaged Auxiliary Transformers By New One Or Repaired One ( To Be Provided By The Department ) Including All Carriages Installation Of New Transformer And Dismantling Of Damaged One. 262 Sitc For Replacement Of Burnt Out Aluminium Bus Bars ( 100*12Mm ) Of Transformers 263 Replacement Of Burnt / Damaged Bus Bars ( To Be Provided By The Department ) 264 Sitc For Replacement Of Damaged Bushes Of Hv / Lv Of Power Transformer 265 Replacement Of Damaged Bushes Hv / Lv Of Power Transformers ( To Be Provided By The Department ) 266 Miscellaneous Electrical Works 267 Proving And Fixing Of 1 No Lighting Point Using 1.5Mm2 Pvc Copper Wire Inpvc Channnel / Conduit Pipescomplete Withswitch & Socket And 10Watt Led Lamps. 268 Proving And Fixing Of 1 No Heatingpoint Using 4.0Mm2 Pvc Copper Wire Inpvc Channnel / Conduit Pipescomplete With Complete With 32 Amp Dp Switch 269 Replacement Of Damagedceiling Fans 1400Mm At Control Room Of Receiving Stations Of Havells , Crompton Greaves Anchor. 270 Provinding And Fixing Of Water Lifting Motors 1Hp ( Havells.Usha, Crompton Greaves At Receiving Stations 271 Replacement Of Old / Damaged Led Lamp With New 15 Watt Lamp ( Make Havells, Crompton Greaves, Syska, Philips ) 272 Replacement Of Old Damaged Led Torch With New High Beam 2Km Focus Heavy Duty Rechargable Lec Torrch 15-20 Watt 273 Deweeding Of Switch Yards / Receiving Stations / Stores 274 Sitc Of Wifi Cctv Systemwith Four Cameras ( Two Indoor And Two Out Door With Built In Microphone, Resolution Of 4Mp Coloured , Night Vision ) With All Accessories Like Dvr, Monitor 1Tb Data Storage, Cable Etc Complete .The Oudoor Cameras Shouldhave Range Of 200 Feet Whereas The Indoor Cameras Should Have A Range Of 30 Feet. 275 Sitc Of Cctv Systemwith Four Cameras ( Two Indoor And Two Out Door With Built In Microphone, Resolution Of 4Mp Coloured , Night Vision ) With All Accessories Like Dvr, Monitor 1Tb Data Storage, Cable Etc Complete .The Oudoor Cameras Shouldhave Range Of 200 Feet Whereas The Indoor Cameras Should Have A Range Of 30 Feet. 276 Providing And Fixing Chainlink Fencing Of 33 Kv Yard Of Substation Byway Of Mass Concrete In Foundations And Chainlink Fencing Of 6 Ft Height 277 Fixing Of Chainlink Fencing Of 33 Kv Yard Of Substation Byway Of Mass Concrete In Foundations And Chainlink Fencing Of 6 Ft Height ( Chain Link Fencing / Mesh To Be Provided By The Department ) 278 Compound Walling Of Yard / Control Rooms / Land Etc, By Way Ofmass Concrete In Foundations And 228 Mm Brick Wall Of 2 M Height 279 Providing And Fixing Earthing Mat ( Gi Flat 50 Mm X8 Mm ) At Receiving Stations 280 Fixing Of Earthing Mat ( Gi Flat 50 Mm X8 Mm ) At Receiving Stations 281 Sitc For Replacement Of Damaged / Defective 3Ph3 Wire Ht Ct / Pt Operated Fully Static Smart Tri-Vector Energy Meters Dlmscompliant Category C With Rs232 Port For Modem Compatibility. 11Kv / 110V, Ph-Ph ( 3P, 3W ) Meters For Measurement Of Different Electrical Parameters Including Active Energy ( Kwh / Mwh ) , Reactive Energy ( Kvarh / Mvarh ) , Apparent Energy ( Kvah / Mvah ) Etc. ( Make L&T, Secure, Abb ) Energy Meters Of 11 Kv Vcb Panels 282 Replacement Of Damaged / Defective3ph3 Wire Ht Ct / Pt Operated Fully Static Smart Tri-Vector Energy Meters Dlmscompliant Category C With Rs232 Port For Modem Compatibility. 11Kv / 110V, Ph-Ph ( 3P, 3W ) Meters For Measurement Of Different Electrical Parameters Including Active Energy ( Kwh / Mwh ) , Reactive Energy ( Kvarh / Mvarh ) , Apparent Energy ( Kvah / Mvah ) Etc. ( Make L&T, Secure, Abb ) Energy Meters Of 11 Kv Vcb Panels Energy Meters Of 11 Kv Vcb Panels ( To Be Provided By The Department )

Key Value

Document Fees
INR 1000 /-
EMD
INR 50000.0 /-
Tender Value
Refer document

Attachment

FileName File Description File Size
d17bffde-ed62-4010-88a9-45bf803f0e6c.html Tender Notice 0 KB
BOQ_723378.xls Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB
Tendernotice_2.pdf Tender Document 0 KB