Repair Maintenance Of Em Services At Chhatrasaal Stadium Model Town Delhi. Sh Operation Maintenance Of Ei Fans Substation Dg Set Fire Alarm, Wet Riser Cum Sprinkler System Fountain Pump Sets Etc, Delhi-Delhi

Public Works Department-PWD has published Repair Maintenance Of Em Services At Chhatrasaal Stadium Model Town Delhi. Sh Operation Maintenance Of Ei Fans Substation Dg Set Fire Alarm, Wet Riser Cum Sprinkler System Fountain Pump Sets Etc. Submission Date for this Tender is 18-04-2024. Electrical Maintenance Tenders in Delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

43146652
Repair Maintenance Of Em Services At Chhatrasaal Stadium Model Town Delhi. Sh Operation Maintenance Of Ei Fans Substation Dg Set Fire Alarm, Wet Riser Cum Sprinkler System Fountain Pump Sets Etc
Open Tender
Indian
Delhi
Delhi
18-04-2024

Tender Details

Repair Maintenance Of Em Services At Chhatrasaal Stadium Model Town Delhi. Sh Operation Maintenance Of Ei Fans Substation Dg Set Fire Alarm, Wet Riser Cum Sprinkler System Fountain Pump Sets Etc

Key Value

Document Fees
Refer document
EMD
INR 150366.0 /-
Tender Value
INR 75.18 Lakhs /-

BOQ Items

Name of Work:RMO E&M Services at Chhatrasaal Stadium, Model Town, Delhi. (SH:- Operation & Maintenance of EI & Fans, Sub-station, DG set, Fire Alarm, Wet Riser cum Sprinkler System, Fountain & Pump sets etc).
Sl. No. Item Description
1SH:- I (Maintenance & Operation) Providing servicesfordaytoday maintenance, upkeep & operation of allelectricalinstallations as per inventory attached on all days including Sunday and holidays etc. as required.
2SH:- II (EI Work) Rewinding of 1200mm ceiling fans with super enamelled copper wire including inspection of fan suspension arrangement and tightnesss of nuts and bolts, cotter pin, rubber reel and replacement of the same wherever found defective during inspection for safe running of fan i/c cleaning the fan with detergent i/c less for old dismantle complete etc as reqd.
3Rewinding of 300/380/450 mm exhaust fan including inspection of fan fixing arrangement and tightness of nuts and bolts i/c cleaning the fan with detergent i/c less for old dismantle complete etc as required.
4Servicing and overhauling of HT 400/630/800 Amp VCB/OCB complete etc. as required i/c routine yearly check up and reports etc. as well as testing & calibration of micro processor controlled relay of HT panel routine test etc. as reqd. with the help of relay testing machine etc. as required (a) O/C relay-2 nos. (b) Earth fault relay-1 no. (c) Master relay-1 no. (d) Trip circuit supervision relay-1 no
5Servicing of draw out type 800 amp/1000 amp/1600 amp/2000 amp, ACB 3 Phase 415 volt 50 Hz from the MV Panel, complete cleaning lubricating of moving parts checking and testing of wiring system, replacment of minor space parts such as spring, nuts bolts and washer, setting right the mechanism and reassembling testing and commissioning etc as required. (The work involves replacement of worn-out part with material within quoted rate)
6Calibration of Over Current and earth fault numeric type relay cleaning checking of wiring system calibration with secondary injection test kit setting of tripping according to the load complete with testing and commissioning as require.
7Complete comprehensive, running maintenance i/c regular servicing of following capacity Window / Split AC installed in AAMCs i/c replacement all defective parts i.e. blower motor, compressor, Gas Charging, PCB, remote, Plug Top, Starting Capacitor, Running Capacitor, Starting Relay, Thermostat, Propeller Fan, Over load Relay i/c condenser unit, evaporative unit charging of refrigerant gas in case of leakage i/c replacement of refrigerant gas pipe with insulation, lead wire, plug Top, etc complete as per terms and conditions attached:- a) Total 11 Nos. Window type AC/ Split type AC of 1.5TR/2.0 TR capacity (11 Job Per Month, 11 x12 = 132 Jobs)
8Lifting of existing submersible bore well / open well 3HP to 10 HP capacity Pump set from the bore well with chain pulley block & tripod stand i/c cartage charge at site from the work shop etc. as reqd.
9Lowering of 3 HP to 10 HP capacity bore well/open well pumpset in the bore well with chain pulley block and tripod stand i/c cartage charge pump set from work shop to site credit of old dismantle etc, as reqd.
10Supplying and fixing 6 mm size steel wire rope nylon insulated i/c D locking arrangement at the end for holding submersible pump set complete etc as reqd.
11Repairing of Mono submersible pump upto 7.5 HP complete dismantling and carrying out the following works i/c cartage pf pump to and from site to workshop i/c credit of dismantle, testing & commissioning etc as required. Motor bush bearing - 1 No. Rotor sleeve polishing grinding - 1 No. Motor seal - 04 Nos. Motor Studs - 01 No.
12Rewinding of Mono submersible motor upto 7.5 HP complete dismantling and carrying out the following works i/c cartage pf pump to and from site to workshop i/c credit of dismantle, testing & commissioning etc as required.
13Charges for hiring of Tower wagon/ Hydra of suitable height for installation of stands light/ fixing of cable etc complete as reqd. as per the direction of Engineer-incharge.
14SH:- III (Supply of material) Supply of following materials:- a) 5/6 A switch (Modular type)
15b) 15/16 A switch (Modular type)
16c) 3 pin 5/6 A socket outlet (Modular type)
17d) 6 pin 15/16 A socket outlet (Modular type)
18e) Stepped type Modular Fan regulator (2 module)
19f) 1 or 2 Module Modular base & Cover plate
20g) 3 Module Modular base & Cover plate
21h) 6 Module Modular base & Cover plate
22i) 8 Module Modular base & Cover plate
23j) 12 Module Modular base & Cover plate
24k) 5A to 32Amp SP MCB 10kA rating"C" Curve
25l) 1.5 sq. mm sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable
26m) 4 sq. mm sq. mm sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable
27n) 3 pole MCCB, 100A, 16kA (Ics = 100% Icu)
28o) 3 pole MCCB, 200A, 25kA (Ics = 100% Icu)
29p) 40/63 Amp, SPN MCB 10kA rating"C" Curve
30q) 40/63 Amp TP MCB 10 kA rating "C" Curve
31r) 2.50 mfd capacitor
32s) 3.15 mfd capacitor
33t) 1x20 Watt 4 feet Indoor commercial LED batten fitting with extruded aluminium housing with minimum 120 lumens per watt.
34u) 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor with remote or electronic regulator.
35v) Heavy duty metal exhaust fan of 300 mm sweep 900 rpm.
36w) Heavy duty metal exhaust fan of 380 mm sweep 1400 rpm.
37SH:- IV (Credit of old dismantle material) Less credit for dismantle of following items:- a) 5/6A distorted switch (Modular/Piano type)
38b) 15/16A distorted switch (Modular/Piano type)
39c) 5/6A distorted Socket (Modular/Piano type)
40d) 15/16A distorted socket (Modular/Piano type)
41e) Fan Regulator (Modular/Piano type)
42f) 1/2/3/6/8/12 modular damaged cover plate
43g) 6-32A SP/DP MCB distorted/damaged
44h) 40/63 DP/SPN/TP/FP MCB distorted/damaged
45i) Assorted size Copper wire cut pieces
46j) 18W/20 Watt LED Batten Fittings distorted/damaged
47k) 80W/120W/150Watt LED Flood lights fittings distorted/damaged
48l) 12/15 Watt LED Downlights distorted/damaged
49m) 100A/200A 3P MCCB distorted/damaged
50n) 2.50/3.15mfdCapacitor distorted/damaged
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail