Tender For Providing And Fixing Of Electrical Installation Work Newly Occupied Building 99B And C For Setting Up The Labs Instruments Etc. At Iit Delhi, delhi-Delhi

Indian Institute Of Technology-IITB has published Tender For Providing And Fixing Of Electrical Installation Work Newly Occupied Building 99B And C For Setting Up The Labs Instruments Etc. At Iit Delhi. Submission Date for this Tender is 26-04-2024. Electrical Maintenance Tenders in delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

43144202
Corrigendum : Tender For Providing And Fixing Of Electrical Installation Work Newly Occupied Building 99B And C For Setting Up The Labs Instruments Etc. At Iit Delhi
Open Tender
Indian
Delhi
delhi
26-04-2024

Tender Details

Providing And Fixing Of Electrical Installation Work Newly Occupied Building 99B And C For Setting Up The Labs Instruments Etc. At Iit Delhi

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 16-Apr-2024 Corrigendum Other 19-04-2024
2 19-Apr-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 26-04-2024

Key Value

Document Fees
Refer document
EMD
INR 663506.0 /-
Tender Value
INR 3.31 Crore /-

BOQ Items

Name of Work : Providing and fixing of Electrical Installation workNewly occupied building 99B & C for setting up the lab"s instruments etc. at IIT Delhi.
Sl. No. Item Description
1Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, withmodular switch,modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
2Group C
3Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copperconductorsinglecorecableinsurface/recessedsteel conduitalongwith 1No. 4sq.mmFRLSPVCinsulatedcopper conductor single core cable for loop earthing as required.
4Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copperconductorsinglecorecableinsurface/recessedsteel conduit alongwith 2Nos.4 sq.mmFRLSPVCinsulated copper conductor single core cable for loop earthing as required.
5Wiringforcircuit/submainwiringalongwithearthwirewiththe followingsizesofFRLSPVCinsulatedcopper conductor,single core cable in surface/ recessed steel conduit as required.
62 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
72 X 4 sq. mm + 1 X 4 sq. mm earth wire
82 X 6 sq. mm + 1 X 6 sq. mm earth wire
92 X 10 sq. mm + 1 X 6 sq. mm earth wire
10SupplyinganddrawingfollowingsizesofFRLSPVCinsulated copperconductor, singlecorecableintheexistingsurface/ recessed steel/ PVC conduit as required.
113 x 1.5 sq. mm
123 x 2.5 sq. mm
136 x 2.5 sq. mm
143 x 4 sq. mm
156 x 4 sq. mm
163 x 6 sq. mm
176 x 6 sq. mm
18Supplyingand drawingfollowingpair 0.5mmdiaFRLSPVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.
192 Pair
20Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
2125 mm
2232 mm
23Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
2420 mm
2525 mm
26Supplying and fixing following modular switch/ socket on the existing modularplate&switchboxincludingconnectionsbutexcluding modular plate etc. as required.
275/6 A switch
2815/16 A switch
293 pin 5/6 A socket outlet
306 pin 15/16 A socket outlet
31Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
32Supplyingandfixingfollowingsize/modules,GIboxalongwith modular base & cover plate for modular switches in recess etc. as required.
333 Module (100mmX75mm)
346 Module (200mmX75mm)
3512 Module (200mmX150nnm)
36Supplying and fixing suitable size GI box withmodular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 &15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
37Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socketoutletand 25 A modularSPMCB,"C"curveincluding connections, painting etc. as required.
38Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
39100 A, 16 KA,TPMCCB
40125 A, 16 KA,TPMCCB
41150 A, 16 KA,TPMCCB
42Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar,din bar,interconnections,powderpaintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator)
438 way , Double door
4412 way , Double door
4516 way, Double door
46Supplyingand fixingof following ways surface/ recessmounting, vertical type, 415 V, TPN MOB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MOB TPDB is normally used where 3 phase outlets are required.)
474 way (4 + 12), Double door
488 way (4 + 24), Double door
4912 way (4 + 36), Double door
50Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles intheexistingMOBDBcompletewithconnections,testingand commissioning etc. as required.
51Single pole
52Double pole
53Triple pole
54Supplying and fixing single pole blanking plate in the existing MOB DB complete etc. as required.
55Supplying and fixing following rating, double pole, (single phase and neutral), 240 V,residual current circuit breaker (RCCB),having a sensitivity current 30mA inthe existingMCBDBcomplete with connections, testing and commissioning etc. as required.
5640A
5763A
58Supplying and fixing followingrating, four pole, (threephase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30mA in the existingMCBDB complete with connections, testing and commissioning etc. as required.
5940A
6063A
61Supplying and fixing DP sheet steel enclosure on surface/ recess alongwith 25/32A240V"C"curveDPMCBcompletewith connections, testing and commissioning etc. as required.
62Supplying and fixing TP sheet steel enclosure on surface/ recess alongwith 16/25/32 A 415 V"C"curveTPMCBcomplete with connections, testing and commissioning etc. as required.
63Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
64Supplying and fixing 20 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, TPMCB,in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
65Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 A "C" curve, TPMCB,in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
66Supplying and fixing Cable End Box (Loose Wire Box) suitable for triple pole and neutral, sheet steel, Vertical MCB distribution board, 415 Volts, on surface/ recess, complete withtesting and commissioning etc. as required.
67Supplying,installing,testingandcommissioningoffollowing capacity TPN tap off box made of 1.6mm thick sheet steel enclosure duly painted with powder coating on existing rising mains complete with TPN disconnector FSU and HRC fuses, connections, earthing etc. as required.
68200 A TPN
69400 A TPN
70Supplying,installing,testingandcommissioningoffollowing capacity TPN distribution tap off box made of 1.6mm thick sheet steel enclosure duly painted with powder coating on existing rising mains complete with HRC fuses, interconnections, earthing etc. as required.
7163 A TPN, 4 way
72Supplying,installing,testingandcommissioning offollowing capacity End Feed Unit made of 1.6mm thick sheet steel enclosure duly painted with powder coating to existing rising mains complete with TPN disconnector FSU and HRC fuses, mounting stands, cable endbox,brass compressiongland,connections,earthing etc.as required.
73200 A TPN
74Supplying and installing following size of perforated Hot Dipped GalvanisedIron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joinedwithconnectors,suspendedfromtheceilingwithG.I. suspenders including G.I. bolts & nuts, etc. as required.
75150 mm width X 50 mm depth X 1.6 mm thickness
76300 mm width X 50 mm depth X 1.6 mm thickness
77SupplyingandinstallingfollowingsizeofperforatedHotDipped GalvanisedIron cable tray "bends" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joinedwithconnectors,suspendedfromtheceilingwithG.I. suspenders including G.I. bolts & nuts, etc. as required.
78150 mm width X 50 mm depth X 1.6 mm thickness
79300 mm width X 50 mm depth X 1.6 mm thickness
80Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories,andprovidingmasonryenclosurewithcoverplate havinglocking arrangement and wateringpipe etc. with charcoal/ coke and salt as required.
81Earthing withG.I.earthplate 600mm X 600 mm X 6mm thick including accessories, and providing masonry enclosure with cover plate havinglocking arrangement and wateringpipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
82Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate havinglocking arrangement and wateringpipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
83Supplying andlaying 25 mm X 5 mm copper strip at 0.50 metre belowground asstrip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
84Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below groundas strip earthelectrode,includingconnection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
85Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.
86Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
87Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
88Providing and fixing 25 mm X 5 mm GI. strip on surface or in recess for connections etc. as required.
89Providing and fixing 6 SWG dia GI. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ subnnain wiring/ cable as required.
90Providingandfixing4.00mmdiacopper wireonsurfaceorin recessforloopearthingalongwithexistingsurface/recessed conduit/ submain wiring/ cable as required.
91Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required.
92Jointing copper! G.I. tape (with another copper/ G I tape, base of thefinialoranyothermetallicobject)byriveting /nutbolting/ sweating and soldering etc as required.
93Supplyingandmakingendterminationwithbrass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1KV grade as required.
943.5X 35 sq. mm (32mm)
953.5 X 50 sq. mm (35mm)
963.5 X 70 sq. mm (38mm)
973.5 X 150 sq. mm (50mm)
984 X 16 sq. mm (28mm)
99Supplying, laying, fixing, testing and commissioning of following thickness closed cell elastrometric nitrile rubber of class "O" applied  by  suiatable  adhesive,  as per specifications and as required complete in all respect.
10032mm
10119mm
102Providing and fixing DLP plastic trunking of size 105 mm x 50 mm onsurface as reqd.[Make Legrand]
103PVC trunking without cover of size 105 x 50 mm size
104PVC trunking full cover of size 85 mm size
105PVC trunking Left or right End cap
106PVC trunking Internal angle adjustable from 80°-100°
107PVC trunking External angle adjustable from 60°-120
108PVC trunking 90°Flat angle
109PVC trunking Cover joint for 85 mm width
110PVC trunking base/body joint
1116/8 Modules clip on framewith finishing plate for 85 mm cover
112Modular 5/6 amps switch on the existing modular plate & switch box / channel including connection
113Modular 5/6 amps socket on the existing moudular plate & switch box including connection.
114Modular 16A/20 amps switch on the existing modular plate & switch box / channel including connection
115Modular 6/16 amps multi socket on the existing moudular plate & switch box including connection.
116Information data socket RJ45 with shutter with moudular plate
117Telephone socket RJ11 with shutter with moudular plate
118Supplying, installation DLP mini- trunking 32mm x 20mm with independent cover etc. complete as reqd.[Make Legrand]
119PVC mini trunking with independent cover of size 32mm x 20mmsize.
120PVC mini trunking End cap left or right.
121PVC mini trunking Internal/ External angle from 60°-120°
122PVC mini trunking Flat angle from 85°-95°
123PVC mini trunking Flat junction
124Supplying and laying of PVC insulated, PVC sheathed XLPE aluminium conductor armored cable ofFollowing size, 1.1 KV grade, direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. etc. as required [conforming to I.S-1554/1/8]
1254 X 16 sq. mm
1263½ X 35 sq. mm
1273½ X 50 sq. mm
1283½ X 70 sq. mm
1293½ X 150 sq. mm
130Supplying and laying of PVC insulated, PVC sheathed XLPE aluminium conductor armored cable ofFollowing size, 1.1 KV grade in the existing RCC/ HUME/ METAL pipe as required. [conforming to I.S-1554/1/8].
1314 X 16 sq. mm
1323½ X 35 sq. mm
1333½ X 50 sq. mm
1343½ X 70 sq. mm
1353½ X 150 sq. mm
136supplying and laying and Fixing of PVC insulated, PVC sheathed XLPE aluminium conductor armored cable ofFollowing size, 1.1 KV grade on wall surface as required.Upto 35 sq. mm (clamped with 1 mm thick saddle)Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm [conforming to I.S-1554/1/8].
1374 X 16 sq. mm
1383½ X 35 sq. mm
1393½ X 50 sq. mm
1403½ X 70 sq. mm
1413½ X 150 sq. mm
142Fans.
143Supplying and fixingof 450mm Wall mount fan complete with all accessories for use on 220/240 volts 50 HZ, single phase A/C Supply including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor single/ multi core cable etc as reqd
144Supply and installation of SS enclosure duly powder Coated paint for housing incomming MCCB 4P, of appropiate size with incomming and outgoing opening, suitable to accommodate upto 70sqmm, 3.5 core aluminium armoured cable,with louvers for heat dissipation and mounting hole for easy wall mounting. (matter: AC / Normal / Emergency Power) etc. as required
145Supply and installation of SS enclosure duly powder Coated paint for housing incomming MCCB 4P, of appropiate size with incomming and outgoing opening, suitable to accommodate upto 300sqmm, 3.5 core aluminium armoured cable,with louvers for heat dissipation and mounting hole for easy wall mounting. (matter: AC / Normal / Emergency Power) etc. as required. (Make: L&T / Schneider / Legrand / Havells / C&S / Siemen / ABB)
146Providing and fixing DLP plastic trunking of size 150 mm x 50 mm onsurface as reqd.[Make Legrand]
147DLP plastic trunking of size 150 mm x 50 mm without cover
148PVC trunking full cover of size 85 mm size
149PVC trunking full cover of size 40 mm size
150Clip on Partition (Plastic)
151PVC trunking Left or right End cap
152PVC trunking Internal angle adjustable from 80°-100°
153PVC trunking External angle adjustable from 60°-120°
154PVC trunking 90°Flat angle
155PVC trunking Cover joint
156PVC trunking base/body joint
1576/8 Modules clip on framewith finishing plate for 85 mm cover
1581 Modules clip on framewith finishing plate for 40 mm cover
159Modular 5/6 amps switch on the existing modular plate & switch box / channel including connection
160Modular 5/6 amps socket on the existing moudular plate & switch box including connection.
161Modular 16A/20 amps switch on the existing modular plate & switch box / channel including connection
162Modular 6/16 amps multi socket on the existing moudular plate & switch box including connection.
163Telephone socket RJ11 with shutter inthe existing moudular plate
164Information data socket RJ45 with shutter inthe existing moudular plate
165Supply, Making, Testing & commissioning of Advance maintenance free Chemical Gel Earthing of single pipe Technology( copper) of 3 mtr. long 50 mm dia fiiled with highly conducting metallic compound with the permanent sealings at the both the ends with the lead terminal 32x10mm at the top along with 50kgs of chemical gel for (mixture of sulphate, Silica, Alumina, Iron Oxide, Titanium Oxide, Magnesium Oxide, Sodium Oxide, Zinc Oxide etc. ) Resitance lowering grounding Minerals. The loss on ignition by mass of the chemical compound should be tested and certified by any International accredited and BIS ( Bureau of Indian Standard) accredited laboratory. The Chemical earth electrode manufacturer shall be an ISO 9001:2008 & ISO 14001:2001 certified organization. The Testing laboratory should be ISO 14001 certified. The JK CHEMRODE shall be duly tested & certified by CPRI ( Central Power Research Institute) Govt. of India for a minimum short circuit current of 30 KA rms. The Chemical Earth electrode manufacturer shall be an ISO 9001:2008 & ISO 14001:2004 certified organisation.along with Heavy duty polyplastic weather proof earth pit/ chamber.
166Electrical Panel board Design, Fabrication, Supplying, testing & commissioning of front operated cubicle type compartmentalized, front access free standing, dust and vermin proof (IP 54)panel board of 1750x 1550x 400 mm size suitable for use at 415 volt, 3 phase, 4 wire, 50 hertz system suitable for fault level of required value symmetrical at 415 volts, made out of 2mm thick CRCA MS sheet with hinged, gasketed(metal based neoprene) and lockable doors having structural reinforcement with suitable angle/channel/ T/ Flat/ sections including 3 mm thick gland plates on top and bottom andlifting hooks andGI earth strip of required size with 2 nos. earthing terminal and powder coated paint finish of approved shade over metal surface cleaned and treated with seven tank process complete with frame duly erection in ground and interconnection with copper conductor etc. as specification, as complete as required confirming to IS8623:93as below. [Note:- The panel should be IS 8623:93, IEC 61439 part-1 and II manufacturer has to produces the relevant test certificate as per IEC code for the same failing which panel shall be rejected) and CPRI Approved.]
167Incoming: (a) 400 amp, 4P, 36KA, 50HZ, 415V, AC MCCB with thermal magnetic based releases for O/C & S/C protection =01 Nos. Bus Bar Electrolytic high conductivity aluminium, three phase and neutral busbars rated at 630 amps having a maximum current density of 120 A/sq cm suitable to with stand symmetrical fault level of 35 kA. at 415 Volts. The Neutral busbar is to be of 100% capacity. Outgoing: (a) 250 amps, 4P, 36KA, 50HZ, 415V, AC MCCB with thermal magnetic based releases for O/C & S/C protection =01 Nos. (b) 125 amps, 4P, 36KA, 50HZ, 415V, AC MCCB with thermal magnetic based releases for O/C & S/C protection =04 Nos. (c) 63 amps, 4P, 36KA, 50HZ, 415V, AC MCCB with thermal magnetic based releases for O/C & S/C protection =04Nos. (d) Earthing studs 2 Nos (e) Danger plate – 01 Nos Metering (a) Digital Ammeter - 01 Nos with accuracy class 1.0 (b) Digital Voltmeter - 01 Nos with accuracy class 1.0 (c) RYB indicating lamp (d) Suitable CT"s (e) Rotatory handle in each switch
168Design, Fabrication, Supplying, testing & commissioning of front operated cubicle type compartmentalized, front access free standing, dust and vermin proof (IP 54)panel board of 1650x 1200x 400 mm size suitable for use at 415 volt, 3 phase, 4 wire, 50 hertz system suitable for fault level of required value symmetrical at 415 volts, made out of 2mm thick CRCA MS sheet with hinged, gasketed(metal based neoprene) and lockable doors having structural reinforcement with suitable angle/channel/ T/ Flat/ sections including 3 mm thick gland plates on top and bottom andlifting hooks andGI earth strip of required size with 2 nos. earthing terminal and powder coated paint finish of approved shade over metal surface cleaned and treated with seven tank process complete with frame duly erection in ground and interconnection with copper conductor etc. as specification, as complete as required confirming to IS8623:93as below. [Note:- The panel should be IS 8623:93, IEC 61439 part-1 and II manufacturer has to produces the relevant test certificate as per IEC code for the same failing which panel shall be rejected) and CPRI Approved.]
169Incoming: (a) 250 amp, 4P, 36KA, 50HZ, 415V, AC MCCB with thermal magnetic based releases for O/C & S/C protection =01 Nos. Bus Bar Electrolytic high conductivity aluminium, three phase and neutral busbars rated at 400 amps having a maximum current density of 120 A/sq cm suitable to with stand symmetrical fault level of 35 kA. at 415 Volts. The Neutral busbar is to be of 100% capacity. Outgoing: (a) 160 amps, 4P, 36KA, 50HZ, 415V, AC MCCB with thermal magnetic based releases for O/C & S/C protection =01 Nos. (b) 125 amps, 4P, 36KA, 50HZ, 415V, AC MCCB with thermal magnetic based releases for O/C & S/C protection =02 Nos. (c) 63 amps, 4P, 36KA, 50HZ, 415V, AC MCCB with thermal magnetic based releases for O/C & S/C protection =04Nos. (d) Earthing studs 2 Nos (e) Danger plate – 01 Nos Metering (a) Digital Ammeter - 01 Nos with accuracy class 1.0 (b) Digital Voltmeter - 01 Nos with accuracy class 1.0 (c) RYB indicating lamp (d) Suitable CT"s (e) Rotatory handle in each switch
170Metal/ G.I Raceways
171Cutting of existing cement concrete floor for 225mm width x 38 mm deep to fix raceway including making good the same with proper cement mortar atc. as required.
172Supplying and fixing 225mm X 38mm,3 compartment type metal / G.I raceway, IP-20 & fixing in floor with all accessories etc. as required.( Make - Legrand)
173Supplying and fixing G.I Junction box / floor box for 225 X225 X 65 mm size etc. as required.( Make- Legrand)
174Supplying and fixing of 225 X 38 mm size G.I bracket for fixing the raceway in floor etc as required.(Make - Legrand)
175Supplying and fixing G.I coupler for 225 mm X 38 mm size G.I raceway etc as required. (Make- Legrand)
176Supplying and fixing G.I vertical riser for 225 mm X 38 mm size G.I raceway etc as required. (Make - Legrand)
177Supplying and laying of PVC innersheathed, XLPE insulated copper conductor armored cable ofFollowing size, 1.1 KV grade, in the existing RCC/ HUME/ METAL pipe as required. [conforming to I.S-7098(Part 1) 1988.
1784 X 16 sq. mm
1794 X 25 sq. mm
1804 X 35 sq. mm
181Supplying and laying of PVC innersheathed, XLPE insulated copper conductor armored cable ofFollowing size, 1.1 KV grade, on wall surface as required.Upto 35 sq. mm (clamped with 1 mm thick saddle) [conforming to I.S-7098(Part 1) 1988.
1824 X 16 sq. mm
1834 X 25 sq. mm
1844 X 35 sq. mm
185Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.(Civil)
186Deployment of Manpower
187Day to Day Operation & Maintenance of Electrical & Mechanical installation along with taking over of General Electricle & Mechanical Service at Engineering block 99 B & C by deploying following minimum staff as required. Technical Foreman = 01Nos. Wireman/ Operator, Mechanic Grade = 07 Nos. Helper Grade: 07 Nos.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail