Public Works Roads Department has published Tender For Construction Of Bridge In Dhemaji District: I) Br. No. 5/2 On Old Nt Road To Chenia. Submission Date for this Tender is 30-04-2024. Bridge Work Tenders in dhemaji Assam. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 14-Apr-2024 | Date Corrigendum | Date | 30-04-2024 |
Sl. No. | Item Description |
1 | Excavation for Structures, Excavation for Structures (Earth work in excavation offoundation of structures as per drawing and technical specification,including setting out,construction of shoring and bracing,removal of stumps and other deleteriousmatter, dressingofsidesandbottomandbackfillingwith approved material, I. Ordinary Soil, B Mechanical Means with dewatering ii) 3.00m to 6.00 m depth(with dewatering) |
2 | Providing and laying cutting edge of mild steel weighing 40 kg per metre for well foundation complete as per drawing and technical specification. |
3 | Providing and laying cutting edge of mild steel weighing 40 kg per metre for well foundation complete as per drawing and technical specification. |
4 | Providing and laying cutting edge of mild steel weighing 40 kg per metre for well foundation complete as per drawing and technical specification. |
5 | Plain/Reinforced cement concrete,in well foundation complete as per drawing and technical specification including steel shuttering formwork. (N) Without plasticiser, A. Well Curb, (iv) RCC M35 Grade, Case II -With Batching Plant,Transit Mixer and Concrete Pump |
6 | Plain/Reinforced cement concrete,in well foundation complete as per drawing and technical specification including steel shuttering formwork. (N) Without plasticiser, B. Well Steining, (viii) RCC M35 Grade, Case II -With Batching Plant,Transit Mixer and Concrete Pump |
7 | Plain/Reinforced cement concrete,in well foundation complete as per drawing and technical specification including steel shuttering formwork. (N) Without plasticiser, C.Bottom Plug, (ii) PCC M25 Grade, Case II -With Batching Plant,Transit Mixer and Concrete Pump |
8 | Plain/Reinforced cement concrete,in well foundation complete as per drawing and technical specification including steel shuttering formwork. (N) Without plasticiser, F.Well Cap, (iv) RCC M35 Grade, Case II -With Batching Plant,Transit Mixer and Concrete Pump. |
9 | Sinking of 7 m external diameter well ( other than pneumatic method of sinking ) through all types of strata namely sandysoil,clayey soilandrockasshownagainsteachcase, completeasper drawing and technical specifications.Depth ofsinking is rekonewed from bed level. (A) Sandy Soil (i) Depth below bed level upto 3.0 M. |
10 | Sinking of 7 m external diameter well ( other than pneumatic method of sinking ) through all types of strata namely sandysoil,clayey soilandrockasshownagainsteachcase, completeasper drawing and technical specifications.Depth ofsinking is rekonewed from bed level. (A) Sandy Soil (ii) Beyond 3m upto 10m depth |
11 | Sinking of 7 m external diameter well ( other than pneumatic method of sinking ) through all types of strata namely sandysoil,clayey soilandrockasshownagainsteachcase, completeasper drawing and technical specifications.Depth ofsinking is rekonewed from bed level. (A) Sandy Soil (iii) Beyond 10m upto 20m. |
12 | Sinking of 7 m external diameter well ( other than pneumatic method of sinking ) through all types of strata namely sandysoil,clayey soilandrockasshownagainsteachcase, completeasper drawing and technical specifications.Depth ofsinking is rekonewed from bed level. (A) Sandy Soil (iv) Beyond 20m upto 30m |
13 | Sinking of 6 m external diameter well ( other than pneumatic method of sinking ) through all types of strata namely sandysoil,clayey soilandrockasshownagainsteachcase, completeasper drawing and technical specifications.Depth ofsinking is rekonewed from bed level. (A) Sandy Soil (i) Depth below bed level upto 3.0 M |
14 | Sinking of 6 m external diameter well ( other than pneumatic method of sinking ) through all types of strata namely sandysoil,clayey soilandrockasshownagainsteachcase, completeasper drawing and technical specifications.Depth ofsinking is rekonewed from bed level. (A) Sandy Soil (ii) Beyond 3m upto 10m depth |
15 | Sinking of 6 m external diameter well ( other than pneumatic method of sinking ) through all types of strata namely sandysoil,clayey soilandrockasshownagainsteachcase, completeasper drawing and technical specifications.Depth ofsinking is rekonewed from bed level. (A) Sandy Soil (iii) Beyond 10m upto 20m |
16 | Sinking of 6 m external diameter well ( other than pneumatic method of sinking ) through all types of strata namely sandysoil,clayey soilandrockasshownagainsteachcase, completeasper drawing and technical specifications.Depth ofsinking is rekonewed from bed level. (A) Sandy Soil (iv) Beyond 20m upto 30 m, (a) For Sinking |
17 | Sinking of 6 m external diameter well ( other than pneumatic method of sinking ) through all types of strata namely sandysoil,clayey soilandrockasshownagainsteachcase, completeasper drawing and technical specifications.Depth ofsinking is rekonewed from bed level. (A) Sandy Soil (v) Beyond 30m upto 40 m |
18 | ReinforcementinFoundation:Supplying, fittingandplacing TMT IS:1786Fe500Dbarreinforcementinfoundationcompleteasper drawing and technical specifications (A) TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/ Jindal panther steel/ Shyam steel or equivalent) |
19 | Plain/ Reinforced Cement Concrete in substructure complete as per Drawing and Technical Specifications.(N) Without plasticiser H) a) RCC Grade M 35 a) Height up to 5.0 m Case-I : Using Concrete Mixer |
20 | Supplying, fitting and placing TMTIS:1786 (Fe 500) bar reinforcement insub-structurecompleteasper drawing and technical specifications (a) TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/ Jindal panther steel/ Shyam steel or equivalent) |
21 | Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wingwall/returnwallwith100mmdia ACpipe,extending throughthe fullwidthofthe structure withslope of1V:20H towards drawing foce. Complete as per drawing and Technical specification. |
22 | Back filling behind abutment,wing wall and return wall complete as per drawing and Technical specification (A)GranularMaterial |
23 | Providingandlayingof Filter mediawithgranularmaterials/stone crushedaggregatessatisfyingtherequirementslaiddowninclause 2504.2.2. of MoRTH specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size toeards the wall and provided over the entire surfaces behind the abutement, wing wall and return wall to the full height compacted to firm condition complete as per drawing and technical specification. |
24 | Supplying, fitting and fixing in position true to line and level POT-PTFE bearing consisting of a metal piston supported by a disc or unreinforced elastomer confined within a metal cylinder, sealing rings, dust seals, PTFE surface sliding against stainlesssteel matting surfaces, complete assembly to be of cast steel/fabricated structural steel, meatal and elastomer elements to be as per IRC:83 part-I &II respectively and parts conforming to BS:5400, complete as per drawing and approved technical specification. |
25 | Furnishing and placing reinforcement / prestressed cement concrete in super structure as per drawing and technical specifications.(N) Without Plasticiser D. RCC/ PSC grade M - 35 Case I : Using concrete mixer For T beam and slab2) Height 5.0m to 10.0 m |
26 | Furnishing and placing reinforcement / prestressed cement concrete in super structure as per drawing and technical specifications. E. RCC Grade M-40, For T beam and slab 2) Height 5.0m to 10.0 m |
27 | Furnishing and placing reinforcement / prestressed cement concrete in super structure as per drawing and technical specifications. E. RCC Grade M-40, For I-beam & slab including launching of precast girders by launching truss upto 40 m span 2) Height 5.0m to 10.0 m |
28 | ReinforcementinSuperStructure:Supplying,fittingandplacing TMT conformingtoIS:1786Fe500Dreinforcementinsuper-structure including splicing complete as per drawing and technical specifications a) TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/ Jindal panther steel/ Shyam steel or equivalent) |
29 | High tensile steel wires / strands including all accessories for stressing , stressing operations and grouting complete as per drawing and technical specifications. |
30 | Providing and laying Cement concrete wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications |
31 | Drainage Spouts complete as per drawing and Technical specification |
32 | PCC M15 Grade leveling course below approach slab complete as per drawing and Technical specification |
33 | Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/ Jindal panther steel/ Shyam steel or equivalent) |
34 | Providing Strip Seal Expansion Joint to cater movement of +70mm as per drawing. |
35 | Span Load Test - Load testing of one or more spans of bridges as selected by the Engineer as per approved load test procedure following relevant IS/IRC/Railway codes with contractor"s labour, deflection measuring instruments, loading materials, recording and analyzing the load testing results including all leads and lifts etc. complete as required. The rates are all inclusive and will be paid after load test is finished and girder is cleared of the kentledges/loading materials etc. The load shall be 1.25 times the stipulated design load based on Design load & not span ( Extra for every increase of 100.00 mt or part there for in the span load capacity up to 800.00 mt. |
36 | Non-Destructive testing with Ultrasonic Pulse Velocity Meter with data storage facility for detection of cracks, voids and other imperfections in Reinforced concrete structures and furnishing the findings thereof in proper comprehensible format, complete as directed by the department |
37 | Non-destructive testing with rebound hammer for detection of damage zones in Reinforced concrete structures and furnishing the findings thereof in proper comprehensible format |
38 | Providing and laying filter material underneath pitching in slopes complete as per drawing and technical specifications Clause 1302 |
39 | Providing and laying pitching on slopes laid over prepared filter media as per drawing and technical specifications Clause 1302 (i) Stone/Boulder |
40 | Providing and laying of boulder apron laid in wire crates with 4 mm dia GI wire conforming to IS:280 and IS:4826 in 100 mm x 100 mm mesh (woven diagonally)including10per centextrafor lapsandjointslaidwith stone boulders weighing not less than 25 kg each as per drawing and technical specifications Clause 1301 |
41 | Earthwork in excavation for foundation of structures as per drawings and technical specifications , including setting out, construction of shoring and bracing, including dewatering and using machinery, removal of stumps and other deleterious matter, dressing of sides and bottom and back filling with approved material .I) In Ordinary Soil. B. Mechanical means.i) Depth up to 3.00 m (with dewatering) |
42 | Plain/Reinforced cement concrete, in open foundation complete as per drawing and technical specification including steel shuttering formwork. I. Without plasticiser. A. PCC Grade M15. |
43 | Plain/Reinforced cement concrete, in open foundation complete as per drawing and technical specification including steel shuttering formwork. I. Without plasticiser.G RCC Grade M30 (i) Using Concrete Mixer |
44 | Supplying, fitting and placing uncoated TMTBar reinforcement in foundation complete as per drawing and Technical Specifications. (a) TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/ Jindal panther steel/ Shyam steel or equivalent) |
45 | Plain/ Reinforced Cement Concrete in substructure complete as per Drawing and Technical Specifications. H) a) RCC Grade M 35 I) Height up to 5.0 mCase-I : Using Concrete Mixer |
46 | Supplying, fitting and placing TMT bars reinforcement in substructure complete as per drawing and Technical Specificationsb)(i) TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/ Jindal panther steel/ Shyam steel or equivalent) |
47 | Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical specification. |
48 | Providing and laying of Filter media with granular materials/stone crushed aggregates satisfying the requirements to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surfaces behind the abutement, wing wall and return wall to the full height compacted to firm condition complete as per drawing and technical specification. |
49 | Constructionofembankmentwithapprovedmaterialobtainedfromborrow pits withaliftupto1.5m,transportingtosite,spreading,gradingtorequiredslope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5(a) from private land |
50 | Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1. (a) from private land |
51 | Construction of granular sub-base by providing well graded material, spreading in uniformlayerswithmotorgraderonpreparedsurface,mixingbymixinplace methodwithrotavator atOMC,andcompactingwithsmooth wheel rollerto achievethe desireddensity,completeasperTechnicalSpecificationClause 401.A)By Mix in Place Method (ii) for grading- IIMaterial |
52 | WBM Grading 2 (A) Using stone screening Type-B 11.2 mm for Gr.II (II) Providing, laying, spreading and compacting stoneaggregates ofspecific sizes to water bound macadam specification including spreading in uniform thickness, handpacking,rollingwithsmooth wheelroller80-100kNinstagestoproper grade and camber, applying and brooming, stone screening/binding materials to fill-uptheintersticesofcoarseaggregate,wateringandcompactingtothe required density grading 2 as per Technical Specification Clause 405.(b) Manual means |
53 | WBM Grading 3, Using stone screening Type-B 11.2 mm for Gr.III (III) Providing, laying, spreading and compacting stoneaggregates ofspecific sizes to water bound macadam specification including spreading in uniform thickness, handpacking,rollingwithsmooth wheelroller80-100kNinstagestoproper grade and camber, applying and brooming, stone screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405. (b) By Manual Means |
54 | Providingand laying interlocking concrete block pavement with M40 grade grade of concrete blocks having thickness 80mm as per technical specification clause 1504 complete including carriage.(i) Including Edge block/ Edge restraints |
55 | Furnishingandlayingofthelivesodsofperennialturfforminggrasson embankmentslope,vergesor otherlocationsshownonthedrawingoras directedbytheEngineerincludingpreparationofground,fetchingofsodsand watering as per Technical Specification Clause 309 |
56 | Providing and fixing of retro-reflectorised cautionary, mandatory and informatory signasperIRC:67madeofencapsulatedlenstypereflectivesheetingvide Clause1701.2.3fixedoveraluminiumsheeting,1.5mmthicksupportedona mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as perdrawings and Technical Specification Clause 801.(i) 600mm equilateral triangle |
57 | Providing and fixing of retro-reflectorised cautionary, mandatory and informatory signasperIRC:67madeofencapsulatedlenstypereflectivesheetingvide Clause1701.2.3fixedoveraluminiumsheeting,1.5mmthicksupportedona mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as perdrawings and Technical Specification Clause 801.(ii) 800mm x 600mm rectangular |
58 | Providing and fixing of retro-reflectorised cautionary, mandatory and informatory signasperIRC:67madeofencapsulatedlenstypereflectivesheetingvide Clause1701.2.3fixedoveraluminiumsheeting,1.5mmthicksupportedona mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as perdrawings and Technical Specification Clause 801.(iii) 600mm circular |
59 | Type - A, "W" : Metal Beam Crash Barrier (Providing and erecting a "W" metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2m center to center, 1.8 m high, 1.1m below ground/road level, all steel parts and fitments to be galvanized by hot dip process, all fitting to conform to IS:1367 and IS:1364, metal beam rail to be fixedon the vertical post with a spacer of channel section 150mmX75mmX5mm, 330mm long complete as per clause 810.) |
60 | PlantingofTreesandtheirMaintenanceforthreeYear (Plantingof trees by the road side (Avenue trees)in 0.60 m dia holes,1 m deep dugintheground, mixingthesoilwithdecayedfarmyard/sludge mannure, plantingthesaplings, backfillingthetrenches,watering, fixing the tree guatrd and maintaining the plants for three year. |
61 | Air quality monitoring at 3 locations* before the start of the construction work and will be treated as the baseline data. (3 locations x Single time=3 nos. of sample); First Year 1st season of the Works |
62 | Water quality monitoring at 3 locations before the start of the construction work and will be treated as the baseline data. (3 locations x Single time=3 nos. of sample); First Year 1st season of the Works |
63 | Noise quality monitoring at 3 locations before the start of the construction work and will be treated as the baseline data. (3 locations x Single time=3 nos. of sample); First Year 1st season of the Works |
64 | Soil quality monitoring at 3 locations before the start of the construction work and will be treated as the baseline data. (3 locations x Single time=3 nos. of sample) First Year 1st season of the Works |
65 | Air quality monitoring at 3 locations for 3 seasons for 2 consecutive years (3x3 Season 3) =9 nos. |
66 | Water quality monitoring at 3 locations for 3 seasons for 2 consecutive years. (3x3 Season 3 =9 nos. |
67 | Noise quality monitoring at 3 locations for 3 seasons for 2 consecutive years. (3x3 Season 3) =9 nos. |
68 | Soil quality monitoring at 3 locations for 3 seasons for 2 consecutive years. (3x3 Season 3) =9 nos. |
69 | Air quality monitoring at 3 locations for 2seasons for 1 year. (3x2 Season X 1 Years) =6 nos. of samples |
70 | Water quality monitoring at 3 locations for 2seasons for 1 year. (3x2 Season X 1 Years) =6 nos. of samples |
71 | Noise quality monitoring at 3 locations for 2 seasons for 1 year. (3x2 Season X 1 Years) =6 nos. of samples |
72 | Soil quality monitoring at 3 locations for 2 seasons for 1 year. (3x2 Season X 1 Years) =6 nos. of samples |
73 | A Provisional sum (Fixed Amount) for the items of Tree Cutting and Compensatory Aforestation of Rs. 1,14,906.00 (not to be changed by the Bidders in BOQ) |