Tender For Upgradation And Extension Of Baffle Range At Nams, jalandhar-Punjab

Military Engineer Services-MES has published Tender For Upgradation And Extension Of Baffle Range At Nams. Submission Date for this Tender is 13-05-2024. Firing Range Tenders in jalandhar Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

43131362
Corrigendum : Tender For Upgradation And Extension Of Baffle Range At Nams
Open Tender
Indian
Punjab
jalandhar
13-05-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Tender For Upgradation And Extension Of Baffle Range At Nams

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 26-Apr-2024 Corrigendum No. 01 dated 26 Apr 2024 Date 13-05-2024
2 30-Apr-2024 Corrigendum No. 03 dated 30 Apr 2024 BOQ 13-05-2024
3 30-Apr-2024 Corrigendum No. 02 dated 30 Apr 2024 Other 13-05-2024

Key Value

Document Fees
INR 1000 /-
EMD
INR 254000.0 /-
Tender Value
INR 1.79 Crore /-

Attachment

FileName File Description File Size
984b05da-9df2-494c-b6d5-c8a18675c512.html Tender Notice 0 KB
BOQ_727207.xls Tender Document 0 KB
DrgSrlNo.1and4to53.pdf Tender Document 0 KB
DrgSrlNo.54to73.pdf Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB
Tender_Baffle_Range_ASR.pdf Tender Document 0 KB

BOQ Items

Name of Work: UPGRADATION AND EXTENSION OF BAFFLE RANGE AT NAMS (TENDER ID: 2024_MES_649491_1)
Sl. No. Item Description
1Note: Please refer Schedule "A" Notes given on serial page No. 14 to 16 of tender documents.
2B/R WORKS
3Surface dressing n.exc 15cm deep in soft/ loose soil complete all as specified and directed
4Excavation over areas in soft/ loose soil not exceeding 1.50m deep and getting out complete all as specified and directed
5All as per Srl item No. 2.02 here-in-before but depth exc 1.5m but not exceeding 3.0m complete all as specified
6Excavation in trenches, n.exc 1.5m wide and n.exc 1.5m depth for foundation, laying of cables etc., and getting out in soft/ loose soil complete all as specified and directed
7Returning, filling in, including spreading, levelling, watering and well ramming in layers under floors or trenches complete all as specified and directed
8Removing excavated material to a distance n.exc. 50m and depositing where directed at a level n.exc. 1.5m above the starting point complete all as specified and directed
9Removing excavated material exc. 500m and n.exc 1.5 km and depositing where directed at a level n.exc. 1.5m above the starting point complete all as specified and directed
10Material and labour for plain cement concrete 1:4:8 type D-2 (using 40mm graded granite stone aggregate) as in foundations, filling and mass concrete complete all as specified and directed
11Material and labour for reinforced cement concrete M-25 (Design mix) using 20mm graded stone aggregate) as in foundations including rafts, footings, foundation beams, plinth beams, bases for columns etc. basement slabs and mass concrete complete all as specified and directed
12Material and labour forreinforced cement concrete M-25 (Design mix) using 20mm gradedstone aggregate) as in roof beam, cantilevers etc. complete all as specified
13Material and labour for RCC M-25 (Design mix) using 20mm graded stone aggregate as in columns, piers, abutments post etc. complete all as specified and directed
14Material and labour for mild steel TMT bars of Fe-500 D Grade, 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hopping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed
15Material and labour for mild steel TMT bars, Fe-500 D Grade, 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bend to shape required and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed
16Material and labour for form work to sides of concrete foundations, footings, base of columns, rafts and raft beams, sides and soffits (if any) of foundation and plinth beams etc. for rough finished flat surfaces complete all as specified and directed
17Material and labour for formwork to sides of pillars, posts struts, piers, columns and stanchions and rough finished surfaces of concrete all as specified and directed
18Material and labour for formwork to sides and soffit of floor or roof beams, beams haunchings, girdered, brussummers, lintels, cantilevers, shelves including sup-ports, overhangs, etc. and rough finished surfaces of concrete all as specified and directed
19Supply and fixing hollow steel Section as in trusses, posts, main and cross beams, hip and jack rafters, purlins, including special shaped washer etc. complete using ERW or induction welded hollow steel Section, conforming to IS 4923, Gde Yst-310 complete all as specified and as shown on drgs
20Supply and fixing mild steel work as in plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes without any attachment conforming to IS-2062 of Gde Fe-410-W (Gde E-250) quality-A complete all as specified and as shown on drgs.
21Supply and fixingmild steel rolled section as in bracket of truss including all necessary drilling, bolting, rivetting or welding etc. and similar work conforming to IS -2062 of Gde Fe-410-W (Gde E-250) quality-A complete all as specified and as shown on drgs.
22Supply and fixing mild steel rolled section flat iron as in wall panelling including all necessary drilling, bolting, rivetting or welding etc. and similar work conforming to IS -2062 of Gde Fe-410-W (Gde E-250) quality-A complete all as specified and as shown on drgs
23Supply and fixing mild steel anchor bolt (machine made) of 4.6 Grade conforming to IS-1367-Part-3 with square or hexagonal head at one end screwed other, fitted with washer and one hexagonal or square exc. 50cm, n.exc 80cm long and 24mm dia complete all as specified and as shown on drgs
24Supply and fixing Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self-tapping screws as specified
25Material and labour for brick work with old size, sub class "B" bricks, straight or curved on plan exc. 6m mean radius built in cement mortar (1.6) complete all as specified and directed
26Material and labour for rendering 12mm thick in cement mortar (1:6) on brick work or concrete surfaces of walls, finished even and smooth without using extra cement complete all as specified and directed.
27Material and labour for rendering cement plaster 15mm thick in cement mortar (1:4) on brick work or concrete surfaces, finished even and smooth without using extra cement mixed with water proofing compound @ 3% by weight of cement complete all as specified and directed. Note :- Water proofing compound shall be measured and paid separately
28Supply only, integral water proofing compound conforming to IS 2645 complete @3% by weight of cement on roof, parapet/ vertical surfaces and like complete all as specified and directed.
29Material and labour for preparing new plasteredor un-plastered surfaces and applying three coats of white wash on walls complete all as specified and directed.
30Material and labour for preparation of new steel surface of any description exc. 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
31Supply and fixing finishing walls with acrylic smooth exterior paint of required shade : new work (two or more coat applied@ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm in camouflage pattern complete all as specified and directed
32Supply and fixing acoustics panel on roof as false ceiling and covering on the two sides of the shed comprising of 25mm thick plyboard, 50mm thick shredded rubber ballistic panel & above that 25mm thick acoustic panel made up of aphony fibrette to be fitted on the ceiling and the sides of the shed using nut bolting/self-screw/tapered screw :- (i) 25mm thick plyboard as per make mentioned in Appx "B". (ii) 50 mm thick shredded ballistic rubber panels IS : Mark (SUNFLEX Make or any equivalent make (with test report). (iii) 25-30 mm thick acoustics panels of aphony fibrette (Himalayan Acoustics) or any equivalent make as approved by GE. Note : Shredded ballistic rubber panel shall be fixed after satisfactory test report from TBRL. The cost of testing shall deemed to be included in rate quoted & nothing extra is admissible on dues account.
33Material and labour for point wiring complete with 1.5 sqmm single core sheathed PVC insulated FRLS cable 1100V grade multi-stranded copper conductor ISI marked of code red, Yellow and blue for phase, black for neutral and green for earth of ISI marked drawn through and including non-metallic rigid PVC conduit of suitable size including accessories ISI marked concealed in wall/ ceiling including PVC insulated copper cable for earth continuity conductor of same type and size and connected to earth dolly including provision of not less than 1.2mm thick MS sunk terminal box of suitable size shall be covered with 3mm thick bakelite laminated sheet cover for mounting switches/ sockets and regulators etc for one light/ ceiling fan/ wall mounting fan/ exhaust fan/ call bell/ bell point/ building light controlled by one switch one way including making good the disturbed surfaces complete all as specified and directed. Note : Cutting chases for laying of conduit, 1.2mm thick MS termination box/ sunken box, 3mm thick bakelite laminated sheet, brass screw, washer etc and making good to walls, floor etc will be included in the above quoted rates
34All as per Srl item No. 2.31 here-in-before but for one socket outlet three pin 5/6 Amps, controlled by one switch on independent board.
35Supply and fixing switch piano ISI marked flush type single pole, one way, 6 Amps, 240V as per IS : 3854/1997 with latest amendments complete all as specified and directed
36Supply and fixing socket outlet multipurpose ISI marked having provision for 3 pin, 5 Amps, 2 pin, 5 Amps, 240V complete all as specified and directed
37Supply and fixing ceiling rose ISI marked three terminal PVC/ polycarbonate, isolated body complete all as specified and directed
38Supply and fixing wall industrial compact batten only suitable for twin LED tube lights with integral LED driver single size connection complete all as specified and directed Make : Havells Cat Part No. STREAKT8UPTO2X22WSSBSWH or equivalent make in Appx "B". Note : LED tube light (Rode) for 2 x 20W will be measured & paid separately.
39Supply and fixing LED lamp 20W tube single side connection suitable for above Srl item No. 36.00complete all as specified and directed Make : Havells Cat Part No. PHOTONULTRAE2.01213T8SSTL20WLED865SPC or equivalent make in Appx "B".
40Supply and fixing sheet metal enclosure with double door flush mounting, MCB, DB, SPN, 4 Ways, 240V, ISI marked volt factory fitted with 200 Amp rated bus bars, earth bar, neutral links complete including blanking plates as required and making good the disturbed surfaces all as specified and directed
41Material and labour for earthingcomplete with galvanized steel earth plate electrode600 x 600 x 6mm thick buried in ground vertical to a depth not less than 2.25 mtrs deep below ground level with top edge of plate not less than 1.5 mtr below normal ground level connected to galvanized GI wire of size 4mm dia and 15mm dia bore 7.5 mtr long light grade GI protection pipe for earth strip and GI watering pipe 40mm dia medium grade from the top edge of earth plate fixed with deep cut onone end of pipe and fix from earth plate up to one feet above ground level of other end and plugged watering pipe at top with MS cap and grouted in PCC 1:2:4 of size 30 x 30 x 30cm etc and 15cm alternate layer of charcoal and salt around all sides of earth plate all as shown in electric plate No 3 of SSR part I of 2009. Notes : (a)The unit rate shall include for protection pipe, GI water pipe, wire mesh, funnel and excavation. RCCpit cover ,test point, and GI earth/ strip, 4mm dia galvanized iron from top of earth plate upto 5m above ground level and if GI protection is less than 5 meter, no price adjustment shall be made. (b) PCCpit shall be provided at least 50 cm away from the earth pitand not just on the earth pit and extra cost of additional length of waterpipes and fittings, junction, elbow etc shall be deemed to be included in the unit rate. (c) If the testing result of earthingwork is not been found satisfactory then the contractor shall do other earthing work at his own cost and nothing shall be permissible on this account. (d)Earthing work will be carried out in presence of MES representative.
42Supply and fixing MCB SP 5-32 Amp, 240V, 10KA, ‘C’ curve and current carrying capacity in the MCB DB compete with connection testing and commissioning all as specified and directed
43Supply and fixing MCB SPN 6-32 Amp, 240V, 10KA, ‘C’ curve and current carrying capacity in the MCB DB compete with connection testing and commissioning all as specified and directed
44Supply and laying LT UG XLPE armoured heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 10 Sqmm, 2 core all as specified and directed
45Material and labour for sand cushioning with a layer of sand 8cm thick before laying of cable and 15cm thick after laying of cable in trenches complete all as specified and directed. Note : Punned down thickness shall be measured for payment.
46Material and labour for cover underground cable with one layer of brick by using Sub Class ‘B’ bricks (old size) laid flat across the cable complete all as specified and directed
47Material and labour for cable protection GI tubing light grade with all fitting and fixture fixed along the pole/ under road/ along the wall of size 40mm bore with necessary clamps complete all as specified and directed
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail