Paschimanchal Vidyut Vitran Nigam Limited has published Tender For Business Plan Work Under Edsd Nagal Under Edd Deoband, Tender For Due To Overloading Of 100 Kva Transformer Located At Gai Dako Wali A 250 Kva Transformer Is Installed. Work To Be Done, 33/11 Kb Tasipur, The Work Of Replacing The Damaged Poles . Submission Date for this Tender is 20-04-2024. Feeder Pillar Tenders in Saharanpur Uttar Pradesh. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Detail of Work |
2 | Providing of Nut & Bolt |
3 | Safely carrage of PCC Pole 8.5 Mtr Long from ESC SRE to site of work including loading and unloading at both ends. |
4 | Grouting of stay rods by digging of pits in block 600x600x300 MM & cementconcreting in ratio 1:4:8 with cement, sand and brick ballast and nozzling of stay wire 7/10 SWG and fitting the same on the pole including fixing of stay insulator in stay wire. |
5 | Safely carriage of Line Material (Except ST Pole/Conductor)ESC SRE to site of works through privet vehicle including loading and unloading at both ends. (Distance 0 to 40 K.M.) |
6 | Earthing of pole by Earthing rod. |
7 | Removal of damage and old ACSR Scrap/GI Scrap from site of work to ESC SRE including loading and unloading at both ends |
8 | providing of All type clamp |
9 | Providing of LT Clamp |
10 | Providing of I Hook |
11 | Safely carriage of ACSR weasel/Rabbit conductor from ESC SRE to site of work including loading and unloading at both ends. |
12 | Laying, lifting, stringing, sagging jump ring & binding of ACSR weasel/Rabbit conductor for HT/LT Line. |
13 | Removal of 100 KVA T/F from the existing D/P after opening HT & LT connection and with shifting the T/F from the site to ESC, SRE/JE store with loading & unloading at both ends. |
14 | Safe cartage of 250 KVA T/F from ESC,SRE, to the site of work including loading & unloading at both ends. (Dist. Upto 30 km.) |
15 | Constriction of plinth for installation of 250 kv T/F of size 1.5x1.5x1.5 mtr made of 9”inch thick wall in all four sides with 6”inch thick RCC top duly filled with sand and plastered 12mm thick in ratio 1:4 with cement and sand on outer surface of brick wall. |
16 | Safe installation of 250 KVA T/F on the Plinth with complete fittings including making connections and commissioning. |
17 | Wire mesh fencing of 250 KVA T/F size 2.5x2.5x2.5 mt. grouting making frame of MS angle 45x45x6 mm and fixing four no. MS strip size 25x6 mm at equal distance in between the frame and fixing squre mesh 50 mm square in each frame the fencing should cover all side of T/F with providing 1 No. door size 6"x3" with sitakni & Dandala. |
18 | Pipe/Water Level Earthing of 250 KVA T/F (1 No body & 1 No. neutral earthing) by boring of 60 Ft deep & fixing of 60 ft. G.I pipe 11/2" Dia (Jindal Class B) and connecting with G.I. Strip of size 40x5 mm and G.I wire at bottom of G.I pipe to the T/F providing of required charcoal & salt in the pipe |
19 | Safely cartage ofAB Cable (3x120+x1x95+1x16)/3x95 from ESC, SRE to the site of work including loading unloading at both ends. (Dist. up to 40 KM.) |
20 | Laying Lifting stringing & Sagging of ABC Cable size (3x120+x1x95+1x16)/3x95 sq.mm. including fixing of all type clamps and connector of all accessories. |
21 | providing of lug |
22 | Laying of LT/XLPE cable 1*240 sq.mm as per respo specification. |