Civil Division has published Tender For Construction Of Academic-Cum-Workshop Building (Gf Plus Ff Plus Sf Plus Hr) Including The Compound Wall, Approach Roads In Respect Of New Govt. Iti At Nilagiri, Balasore.. Submission Date for this Tender is 19-06-2024. Road Work Tenders in Balasore Odisha. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 18-Apr-2024 | 1ST CORRIGENDUM | Date | 19-06-2024 |
FileName | File Description | File Size |
f1de6337-4d40-4adf-94e8-46d1ad437708.html | Tender Notice | 0 KB |
BOQ_500952.xls | Tender Document | 0 KB |
DTCN.pdf | Tender Document | 0 KB |
Tendernotice_1.pdf | Tender Document | 0 KB |
Sl. No. | Item Description |
1 | CIVIL WORK Earth work in excavation of foundation trenches in hard soil including dressing of sides and levelling the bed up to the required depth and depositing the excavated materials away from the work site within 50m initial lead & 1.5m initial lifts with sundries & T&P required for the work complete including cost of all labour,labour cess,T&P,sundries etc.as directed by the Engineer in charge. |
2 | Ground Floor |
3 | Compound Wall |
4 | Drain |
5 | Main Gate |
6 | Security room |
7 | Approach Road |
8 | Cutting in disintegrated rock not requiring blasting to be removed by pick axes and crow bars and depositing materials within 50m lead and 1.5m initial lift including rough dressing as per direction and specification of the department including stacking useful materials separately as ordered. |
9 | Ground Floor |
10 | Supplying and filling in foundation and plinth with good quality river sand including watering, ramming with cost, conveyances, royalties of all materials and cost of all labour with T&P required for the work etc. complete as per specification & direction of Engineer-in-charge |
11 | Ground Floor |
12 | Compound Wall |
13 | Drain |
14 | Main Gate |
15 | Security room |
16 | Approach Road |
17 | Box Culvert |
18 | Providing and laying plain cement concrete of proportion (1:3:6) in foundation and floors using 4 cm. size black hard crusher broken granite stone metal and screened and washed sharp sand for mortar of approved quality and from approved quarry including hoisting, lowering, laying concrete, ramming, watering and curing etc. complete to required levels laid in layers not exceeding 15 cm. thick in each layer including cost, conveyance, royalties of all materials and cost of all labours,labour cess, T&P etc complete as per the direction of the Engineer-in-charge. |
19 | Ground Floor |
20 | Compound Wall |
21 | Drain |
22 | Main Gate |
23 | Security room |
24 | Approach Road |
25 | Fly Ash brick masonry in cement mortar (1:6) in foundation & plinth using Fly Ash bricks of 25 x 12 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge. |
26 | Ground Floor |
27 | Compound Wall |
28 | Main Gate |
29 | SECURITY ROOM |
30 | R.C.C. work of M-20 in following works using 12 mm. to 20 mm. (½” to ¾”) size (20 mm. not to exceed 25%) hard black crusher broken granite stone chips of approved quality from approved quarry including hoisting, lowering, laying and compacting concrete, watering curing, centering, shuttering and finishing the exposed surfaces smooth with cost, conveyance, royalties, taxes of all materials with all labour,labour cess and T & P required for the work etc. complete in all respect but excluding the cost and conveyance of M.S. rods or Tor steel and binding wire of 18 to 20 gauge and labour charges for straightening, cutting, bending, binding and tying the grills and placing in proper position and as per the direction of the Engineer-in-charge. |
31 | BOUNDARY WALL |
32 | Base Footing |
33 | Plinth beam |
34 | Column in Super Structure |
35 | Coping |
36 | MAIN GATE |
37 | Column footing |
38 | Plinth beam |
39 | Column in Super Structure |
40 | Beam |
41 | Roof slab |
42 | SECURITY ROOM |
43 | Column footing |
44 | Plinth beam |
45 | Column in Super Structure |
46 | Beam |
47 | Roof slab |
48 | Chajja |
49 | Lintel |
50 | RCC DRAIN |
51 | Drainbed |
52 | Wall |
53 | Cover slab |
54 | Providing lifting, hoisting and laying R.C.C. of M-25 Grade to base of columns and footing, columns, beams, plinth band, lintels, chajja, shaft, fins, roof slabs, balconies, stair cases, parapets, window sills, lofts, railing, jally, copping or in places as shown in the drawing for all floors with 20mm and down graded size black hard crusher broken ships of approved quality from approved quarry including mixing and vibro compacting to proper shape and size, level and plumbs and finishing the exposed surfaces smooth (if required providing plaster with cement mortar (1:4) wherever necessary without any extra cost) including rigid smooth centering and shuttering, scafolding, watering (excluding reinforcement bars) and curing for required period including cost of all material, labour, conveyance, royality, loading and unloading, sundries, tools and plants etc. complete as per the direction of the Engineer in Charge. |
55 | BUILDING PROPER |
56 | Column Base & Footing |
57 | Plinth beam |
58 | COLUMN IN SUPER STRUCTURE |
59 | Ground Floor |
60 | First Floor |
61 | Second Floor |
62 | Head Room |
63 | LINTEL |
64 | Ground Floor |
65 | First Floor |
66 | Second Floor |
67 | Head Room |
68 | CHAJJA |
69 | Ground Floor |
70 | First Floor |
71 | Second Floor |
72 | Head Room |
73 | STAIRCASE |
74 | Ground Floor |
75 | First Floor |
76 | Second Floor |
77 | ROOF BEAM |
78 | Ground Floor |
79 | First Floor |
80 | Second Floor |
81 | Head Room |
82 | ROOF SLAB |
83 | Ground Floor |
84 | First Floor |
85 | Second Floor |
86 | Head Room |
87 | P.C.C. M-25 grade with 20mm and down grade b.h. granite C.B. chips of approved quality from approved quarry including hoisting, laying, using concrete mixture and vibrators including watering, curing, cost, carriage, royalty of all materials, cost as per the specification & direction of the Engineer-in-charge. |
88 | BOX CULVERT |
89 | Box Portion |
90 | Wall |
91 | Slab |
92 | Fly Ash brick masonry in cement mortar (1:6) in super structure using Fly Ash bricks of 25 x 12 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge. |
93 | Ground Floor |
94 | First Floor |
95 | Second Floor |
96 | Head Room |
97 | Compound Wall |
98 | Main Gate |
99 | Security room |
100 | Supplying Cutting, straightening coiled or bent up M.S. Rod or tor steel of primary steel producers such as SAIL / Tiscon / RINL / JINDAL STEEL / SHYAM STEEL/ SEL Tiger (grade Fe-500D) etc. includingbending, binding, welding and jointing if necessary and tying the grills and placing in position as required for R.C.C. Work and for providing fan hooks as required, hoisting, lowering, laying including cost, conveyances of M.S. Rod or tor steel and binding wires of 18 to 20 gauge and labour required for the work for bending, binding and tying the grills in all floors with labour cess etc. (payment will be made on standard weight of B.I.S. for M.S. Rods or tor steel only) etc. complete as per specification & direction of Engineer-in-charge. |
101 | Ground Floor |
102 | First Floor |
103 | Second Floor |
104 | Head Room |
105 | Compound Wall |
106 | Drain |
107 | Security room |
108 | Box Culvert |
109 | Main Gate |
110 | Providing 6 mm thick cement plaster with cement mortar of mix (1:4) with screened and washed sharp sand for mortar and finished smooth to R.C.C. work after closed deep chipping & slurry treatment including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge. |
111 | Ground Floor |
112 | First Floor |
113 | Second Floor |
114 | Head Room |
115 | Compound Wall |
116 | Security room |
117 | Main Gate |
118 | Providing 12 mm thick cement plaster with cement mortar of mix (1:4) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls punning and bitumen coating including watering and curing with cost, conveyance, royalties of all materials with cost of all labour, and T&P required for the work etc. complete in all respect as directed by the Engineer in charge. |
119 | Ground Floor |
120 | First Floor |
121 | Second Floor |
122 | Providing 12 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge. |
123 | Ground Floor |
124 | First Floor |
125 | Second Floor |
126 | Head Room |
127 | Compound Wall |
128 | Security room |
129 | Main Gate |
130 | Providing 16mm thick cement plaster in cm (1:6) on the rough surface of masonry walls for all floors including racking and joints, scrapping and cleaning the surface and finishing the plastered surface smooth to proper plumbs and level and providing grooves as shown in the drawning including cost of all material, labour, conveyance, loading and unloading, taxes, royalties, sundries, tools and plants etc. complete as per the driection of the Engineer in Charge. |
131 | Ground Floor |
132 | First Floor |
133 | Second Floor |
134 | Head Room |
135 | Compound Wall |
136 | Security room |
137 | Wall painting two coats with Weather coat paint (1st quality) exterior grade of approved make & approved shade over a coat of primer to make an even finished surface in all floors and heights with all scaffolding and staging charges including cost, conveyance, cost of all labours, T & P, sundries etc. as required for the work complete in all respect as per the direction of the Engineer-in-Charge. (Make: Asian/ Berger/ ICI or equivalent make duly approved by Engineer-in-Charge) |
138 | Ground Floor |
139 | First Floor |
140 | Second Floor |
141 | Head Room |
142 | Compound Wall |
143 | Security room |
144 | Main Gate |
145 | Finishing plastered surfaces of walls with cement based Acrylic wall putty (Water based) of approved make (JK White/ Birla white or equivalent make duly approved by Engineer-in-Charge) and finishing the surface smooth and even by sand papering to receive painting in walls, at all heights with staging wherever necessary with cost, conveyance, cost of all labour,labourcess, all T&P etc. required for the work complete in all respect as per the direction of the Engineer-in-charge. |
146 | Ground Floor |
147 | First Floor |
148 | Second Floor |
149 | Head Room |
150 | Security room |
151 | Painting two coats withPlastic Emulsion paint over a coat of water bond cement primer to make an even finished surface in all floors and heights to wall surface of approved make and shade including sand papering, applying putty wherever necessary & cost of scaffolding, staging charges with cost, conveyance, cost of all labour,labour cess, T&P etc. complete as per the direction of the Engineer-in-charge. (Make: Asian/ Berger/ ICI equivalent make) |
152 | Ground Floor |
153 | First Floor |
154 | Second Floor |
155 | Head Room |
156 | Security room |
157 | Supplying, fitting and fixing of openable UPVC doors with door frame of approved make with 6mm thick glass of apprved make (Prominence / FENESTA/NCL VEKA LTD./Koemmerling/ DURAPLAST) quality complete with frame, shutters and all fittings and fixtures including all cost,conveyance,royalty & taxes of all materials,labour,T&P required for the work etc. complete as per specification & direction of the Engineer-in-charge. |
158 | Ground Floor |
159 | Head Room |
160 | Security room |
161 | Dressed seasoned sal woodworkframed andfixedinframesofdoors&windows including cost, conveyanceofall materials and cost of labour for fitting, fixing etc.complete as per the instruction of Engineer-in-Charge . |
162 | Ground Floor |
163 | First Floor |
164 | Second Floor |
165 | Providing and fixing ISI marked 35 mm thick flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak three ply veneering with vertical grains or cross bands and face veneers on both faces of shutters of approved design including cost of all door fittings and fixtures etc. complete as per the direction of Engineer-in charge. |
166 | Ground Floor |
167 | First Floor |
168 | Second Floor |
169 | Supplying, fitting and fixing of two track UPVC sliding window of apporoved make (Prominence / FENESTA/NCL VEKA LTD./ Koemmerling/ DURAPLAST) with 6mm thick glass of approved quality complete with frame, shutters and all fitting and fixturesincluding all cost,conveyance,royalty & taxes of all materials,labour,T&P required for the work etc. complete as per specification & direction of the Engineer-in-charge. |
170 | Ground Floor |
171 | First Floor |
172 | Second Floor |
173 | Head Room |
174 | Security room |
175 | Supplying fitting fixing of Un-plasticcide Poly Vinyl Chloride(UPVC) (FENESTA/NCL VEKA LTD.) Ventilator Series duly Manufactured using UPVC reinforced profiles of 108mm x 45mm x 2.5mm for outer frames and window sash of 39mm x 58mm 2.5mm capable of mounting single galazing system, structurally reinforced with hot dip galvanised up to 50 microns of minimum thickness of 1.5mm perfabricated & welded through fusion welding the window frame shall be with 6mm thick clear thougherned glass of SAINT-GOBAIN make duly fixed with EPDM weathering seal resistance and the system is to be installed using Reinforced Large Coupler at the site using anchor fasteners, silicon rubber sealant, easy glazing/deglazing at site etc., including cost and conveyance of all materials, accessories, labour charges, materials and product conforming to ASTMD 638-14, EN-477-95 and other applicable codes and standards with complete as per specification & direction of the Engineer-in-charge. |
176 | Ground Floor |
177 | First Floor |
178 | Second Floor |
179 | Providing and fixing of Fixed Glazing with part Top hung of approved make to be fabricated from roll formed sections made of pre-painted steel (base steel as per IS-513 of 0.6 mm thick “D” quality, galvanized as per IS-277 with zinc of 120 Gm/Sq.mtr) with paint specification being with primer of 5-7 microns and finished paint with polyster paint (Black /Pearl white/ Chocolate Brown) of 12-16 microns along with the alkyd backer at the back of 5-7 microns and the sizes of outer frame being of 46x52 mm and with all vertical and horizontal mullions are of 46x70 mm and fixed beadings are of 18x25 mm. Top hung shutter should be of 46 x 46 mm. Accessories / gaskets are to be used as per the manufacturer’s supply and specification like handle being made of high grade aluminium powder coated and with nylon receiver and gasket will be made of EPDM. All corner brackets are to be made of CRCA with zinc phosphating. The mullion caps and louvered-clips should be of glass filled nylon. The sections are to be cut to length, mitre joined with corner bracket and frames are fixed to the concrete/masonry walls by means of self-expanding screws and glass to be used of 5 mm reflective with complete as per specification & direction of the Engineer-in-charge. |
180 | Ground Floor |
181 | First Floor |
182 | Second Floor |
183 | Head Room |
184 | Supplying, fitting & fixing in all floors of M.S. grills, grill gates, M.S. gates, garage door, collapsible gates with top and bottom rails, steel windows, critical frames for windows, stair case and parapet railing made out of M.S Square bar/ flat including stair case hand railing with 40mm. dia G.I.pipe etc. including painting two coats over a coat of redoxide primer as per approved drawing and designwith cost of all materials & labour, labour cess, T&P, sundries etc. complete in all respect as per specification & direction of the Engineer-in-Charge. |
185 | Ground Floor |
186 | First Floor |
187 | Second Floor |
188 | Head Room |
189 | Compound Wall |
190 | Security room |
191 | Main Gate |
192 | Supplying, fitting and fixing of Stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @ 0.90mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc with cost, conveyance, cost of all labour,labour cess, T&P etc. required for the work complete in all respect as per direction of the Engineer-in-charge. (Make-JINDAL ) |
193 | Ground Floor |
194 | First Floor |
195 | Second Floor |
196 | Painting two coat with approved synthetic enamel paint to new iron work over a coat of Red oxide primer including cost, conveyances, royalties, taxes of all materials and cost of all labour with T&P required for the work etc. complete as per specification & direction of Engineer in charge. (Make-Asian/ Berger/ Dulux/ ICI or equivalent make duly approved by Engineer-in-charge). |
197 | Ground Floor |
198 | First Floor |
199 | Second Floor |
200 | Head Room |
201 | Compound Wall |
202 | Security room |
203 | Main Gate |
204 | Box Culvert |
205 | Painting two coat with approved synthetic enamel paint to new wood work over a coat of primer including cost, conveyances, royalties, taxes of all materials and cost of all labour with T&P required for the work etc. complete as per specification & direction of Engineer in charge. (Make-Asian/ Berger/ Dulux/ ICI or equivalent make duly approved by Engineer-in-charge). |
206 | Ground Floor |
207 | First Floor |
208 | Second Floor |
209 | Supplying, fitting and fixing vetrified Industrial tiles in floors of premium grade having thickness 8mm to 10mmof size 300mm x 300mm confirming to IS mark with colour / printed series of approved make (JOHNSON /OASIS / RAK / KAJARIA or equivalent ) on 20mm thick bed of C.M. (1:4) including cost of all materials, labour, T&P etc. required for the work in all respect as directed by the Engineer in charge. |
210 | Ground Floor |
211 | First Floor |
212 | Second Floor |
213 | Security room |
214 | Supplying, fitting and fixing vetrified tiles of premium grade having thickness 8mm to 10mm confirming to IS 13756 of size 600mm x 600mm Color / Printed series (Homogenous) ofapproved make (JOHNSON / OASIS/ KAJARIA/ RAK) in floors on 20mm thick bed of C.M. (1:4)(1cement:4course sand) and filling the joint with white cement mixed with pigment to match the shades of the tileincluding cost of all materials, labour, labour cess, T&P etc. required for the work completein all respect as directed by the Engineer in charge. |
215 | Ground Floor |
216 | First Floor |
217 | Second Floor |
218 | Head Room |
219 | Security room |
220 | Providing, fitting, fixing vitrified tiles of premium grade having thickness 8mm to 10mm confirming to IS 13756 of size 600mm x 600mm Color / Printed series (Homogenous)of approved make (JOHNSON / OASIS/ KAJARIA/ RAK)as directed by Engineer-in-charge in dados skirting and risers of steps on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete with cost, conveyance, royalties of all materials all labour,labour cess complete in all respects. |
221 | Ground Floor |
222 | First Floor |
223 | Second Floor |
224 | Head Room |
225 | Security room |
226 | Fixing of Kota tiles of minium thickness 16mm thick of premium grade of size above 0.10 Sqm. in floors over 20mm thick bed of cement mortar 1:4 (1cement:4course sand)and filling the joint with white cement mixed with pigments to match the shade of the tiles, including rubbing & polishing etc. complete including cost, conveyance,royalties of all materials, labour,labour cess with T&P complete in all respects as per direction of Engineer-in-Charge. |
227 | Ground Floor |
228 | First Floor |
229 | Fixing of Kota tiles of minium thickness 16mm thick of premium grade of size above 0.10 Sqm. in Dado over 12mm thick bed of cement mortar 1:3 jointed with cement slurry mixed with pigments to match the shade of the tiles, including rubbing & polishing etc. complete including cost, conveyance & royalties of all materials, labour,labour cess with T&P complete in all respects as per direction of Engineer-in-Charge. |
230 | Ground Floor |
231 | First Floor |
232 | Filling foundation and plinth with excavated materials including all cost, conveyance,royalty & taxes etc.compete of all materials to work site as per specification approved by the department & direction of Engg-in-charge. |
233 | Ground Floor |
234 | Compound Wall |
235 | Main Gate |
236 | Security room |
237 | Box Culvert |
238 | Supplying , fitting and fixing of grid mineral fibre ceiling board having size 600 mm x 600 mm x16mm of approved design and quality complete with frame and all fitting and fixtures including cost, conveyance, materials with cost of labour and T&P required for the work complete as per direction of Engineer-in-Charge. |
239 | Ground Floor |
240 | First Floor |
241 | Second Floor |
242 | Providing Antitermite treatments as per ISI specification including making holes 3"0" C/C both ways injecting chemical with water in propertion(1:20) or any approved propertion by the EIC & treatment to choukath sides &wall junction. Cost & conveyance of all materials, labours, T&P etc complete. as per direction of EIC. |
243 | Ground Floor |
244 | Security room |
245 | Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as g (AR, P-158/37) |
246 | Approach Road |
247 | Construction of granular sub-base by providing Gr.-VI material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller. |
248 | Approach Road |
249 | Supplying and fixing of Pre cast kerb stone of size 600mm x 300mm x 150mm of M-30 grade of approved make, design, colour and size made by Block making machine with proper compaction fixed in required patternetc. complete in all respect as directed by the Engineer in charge. |
250 | Approach Road |
251 | Supplying and fixing of 60mm thick cement concrete interlocking paver block of M-30 grade of approved make, design, colour and size made by Block making machine with proper compaction laid in required patternetc. complete in all respect conforming to IRC SP-63:2018. as per direction of Engineer- in-charge. |
252 | Approach Road |
253 | Supplying and fixing of 80mm thick cement concrete interlocking paver block of M-40 grade of approved make, design, colour and size made by Block making machine with proper compaction laid in required patternetc. complete in all respect conforming to complete as per direction of Engineer- in-charge. |
254 | Approach Road |
255 | Dismantling Rubble stone masonary in cement mortar including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 metres. |
256 | Box Culvert |
257 | Excavation for road way in soil with hydraulic excavator of 0.9cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes in accordance with requirements of lines, grades and cross sections and transporting to the embankment locations with all lifts & leads up to 1000m.as per approved Drawing & Technical Specifications and as per Clause - 301 of MoRT&H Specifications for Road & Bridge works (5th Revision). |
258 | Box Culvert |
259 | Cement concrete M 15 Levelling coarse with 40 mm size C.B. Metal of approved qualityas per approved drawing and direction of the Engineer-in-charge including cost, conveyance, royality taxes of all materials conforming to the MORTH techanical specificat |
260 | Box Culvert |
261 | Providing and laying of Filter media with stone crushed aggregates of 45 mm size satisfying the requirements laid down in clause 2504.2.2. of MoRTH specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment , wing wall and return wall to the full height compacted to a firm condition complete as per drawing and Technical Specification as per direction of Engineer- in-charge. |
262 | Box Culvert |
263 | Gravel backing to revetment |
264 | Box Culvert |
265 | Rough stones dry packing in aprons and revetment with hard other than granite stone 30 cm and above. |
266 | Box Culvert |
267 | Providing weep holes in Brick masonry/Plain/ Reinforced concrete abutment, wing wall/ return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V:20H towards drawing foce. Complete as per drawing and Technical Specifications as per direction of Engineer- in-charge. |
268 | Box Culvert |
269 | E.I. WORK Recessed wirring tolight point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI markedMake- FINOLEX/RR KABEL/POLYCAB/HAVELLS with 20 mm dia PVC flexible non metallic conduit Make-NORPACK/ POLYCAB/Anchor with 6A modular type switch ISI marked Make-Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (Vision), and ceiling rose ISI marked Make- Anchor/Havells/Eq. of modular type G.I box with cover Make-Make-Schneider(Zencelo)/legrand( MYRIOUS) /Panasonic (Vision)of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge.GROUP-A |
270 | GROUP-B |
271 | GROUP-C |
272 | Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge.Make-Schneider/legrand /Panasonic |
273 | Point wiring for 6 amp modularsocket outlet with 2 x 1.5 sq.mm FRLS PVC insulated single core multistrand copper conductor of ISI marked in recess 20 mm dia non-metalic PVC flexible conduit with modular one way type modular switch ISI markedGI box and earthing point with 1 x 1.5 sq.mm FRLS PVCinsulated single core multistrand copper conductor for loop earthing etc. as required.( Make of wire Finolex / L&T / Anchor / Havels / V Guard ) |
274 | Supplying,fixing of 2x6A +1x16A Plug on the separate board with complete fitting by 02 no of 6A switch & socket,1 set 16A Switch(modular type)with suitable size modular box & cover including supplying of all requiredaccessoriesof ISI marked as approved as per direction of engg-in-charge..Make-Make-Schneider(Zencelo)/legrand( MYRIOUS) /Panasonic (Vision) |
275 | Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type)with suitable size modular box & cover including supplying of all requiredaccessoriesof ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( MYRIOUS) /Panasonic (Vision)(For equipement power) |
276 | Receass wiring for circuit/submain wiring with the following mentioned size PVC insulated, copper conductor, single core cable Polycab/ Havells/ Finolex inrecessed PVC conduit (Make- NORPACK or Eq.) Heavy dutyas required as per direction of Engg.-in-Charge. 2x1.5 + 1x1.5 in 20mm dia PVC Pipe |
277 | 2x2.5 + 1x1.5 in 20mm dia PVC Pipe |
278 | 2x4 + 1x1.5 in 20mm dia PVC Pipe |
279 | 2x6 + 1x2.5 in 25 mm dia PVC Pipe |
280 | 4x6 + 2x2.5 in 32 mm dia PVC Pipe |
281 | 4x10 + 2x4 in 32 mm dia PVC Pipe |
282 | Supplying and fixing 32 amps, 240 volts, SPN, industrial type socket outlet, with 2 pole+E-DPplug &socket DB with 32A DP MCB,C series,10ka as per IEC-61439-3 ,suitable for flush & surface mounting,supplied with neutral link with provission for mounting modular devices as per direction of Engg.-in-Charge.. . Make-Legrand( Ekoinex3) or equvalant model of Siemens & Schneider make. |
283 | Supplying and fixing 32 amps, 415 volts, TPN, industrial type socket outlet,with 4 pole+E-4Pplug &socket DB with 32A 4P MCB,C series,10ka as per IEC-61439-3 ,suitable for flush & surface mounting,supplied with neutral link with provission for mounting modular devices as per direction of Engg.-in-Charge.Make-Legrand( Ekoinex3) or equvalant model of Siemens & Schneider make. |
284 | Supplying and fixing 63 amps, 415 volts, TPN, industrial type socket outlet, with 4 pole+E-4Pplug &socket DB with 63A DP MCB,C series,10ka as per IEC-61439-3 ,suitable for flush & surface mounting,supplied with neutral link with provission for mounting modular devices as per direction of Engg.-in-Charge.. .Make-Legrand( Ekoinex3) or equvalant model of Siemens & Schneider make. |
285 | Supplying and fixing AC point consisting of 25A socket outlet Modular type along with 25A starter with all connections and accessories as required as per direction of Engg.-in-Charge.(Make-Legrand/siemens /Schneider |
286 | Supply and fixingCALL bell (Ding dong type) /Buzzer on the existing switch box/cover of as required as per direction of Engg.-in-Charge |
287 | Supplying and fixing batten holder / BK angle holder in place of Ceiling Rose ISI marked including connection etc. as required. |
288 | FIXTURE |
289 | (Light fitting Fixture & Fan)S/F of 300mm exhaust fanin the existing opening, including making the hole to suit the size of the above fan, making good the damage complete, connection, etc as required.(Make- Usha/Orient/Havells/Crompton) |
290 | Supplying, installation, of exhaust fan of heavy duty 380 mm sweep 1400 rpm with louvers (Make-Havells/almonard/cromptron/ Usha makeas approved) of exhaust fan in the existing wall, including fixing & conntection .as required as per direction of Engg.-in-Charge(For workshop & kitchen) |
291 | S/F. Of 400mm Wall fans including all connections and accessories of Usha/Orient/Havells make |
292 | Supplying, installation, testing and commssioning of 1200 mm sweep BLDC ceiling fan with aluminium blades having wattage not more than 28W and Air delivery = 215(m3/min) Make-USHA(Teohnix)/Crompton(Energion Groove)/Havells(Efficiencia Neo) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years.. .(With fan Regulator) |
293 | Supplying an fixing of recess/surface mounted 2"x2" 36 W square shaped LED with lumen efficacy not less than 130lm/W,CRI not less than 80, CCT of 5700-6500 degree K, THD less than 10%,internal surge protection of 3 KV,complete with Non integrated isolated electronic driver(protects the output /secondary side from any disturbance on the input / primary side ensuring safe operation)and all other accessories suitable for operation on140- 270 V, 50 Hz ,L70 @50,000 burning hrs (2 years warranty) as required as per direction of Engg.-in-Charge (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/ Orient/ Bajaj) . The luminaire must be Replacement Warranty will be 2 years. |
294 | S/F of 18Watt Recess mounted round shaped/square shaped LED downlighter with opal diffuser and separate electronic driver.(Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/ Orient/ Bajaj) |
295 | SITC of energy efficient LED tube light fittings with decorative alluminiumbatten and LED tube light having power rating not more than 20 watt and lumen output not less than 2200 lumen complete with electronic driver and all other accessories withdiffuser having 2 years warrantyi/c connection etc as requiredas per direction of Engg.-in-Charge.(Make: Panasonic/LT/ Havells /Philips/ Wipro /Crompton/ Orient/ Bajaj). The luminaire should be Replacement Warranty will be 2 years . |
296 | S/F of 60Watt,5700K LED well glass equiped with isolated electronics driver suitable for industrial application,,IP65,IK10 ,110 lm/w medium bayheighted LED downlighter with all required accessories as required.(Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/ Orient/ Bajaj) |
297 | SITC of Sleek LED 10 watt mirror light fitting with extruded polycarbonate housing,High optically efficient diffuser,above wash basin complete with all accessoriesetc. directly on wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required as per direction of Engg.-in-Charge. (Make: Panasonic/ LT/ Havells /Philips/ Wipro /Crompton/ Orient/ Bajaj)The luminaire should be Replacement Warranty will be 2 years |
298 | Providing and fixing extra down rod of 100 cm length G.I. pipe 20 mm dia heavy gauge including painting etc as required . ( more than 5 cm lenght shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored. |
299 | BDB"S & MCB |
300 | (BDBS,DB,AC DB,FLOOR PANELS,MCBS) Supply and fixing of following way three pole and neutral, sheet steel, MCB distribution, 415 V on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, hinged front acrylic cover for the MCB knobs detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required ( But with out MCB/ RCCB/ Isolator) .Make-Siemens/Schneider/Legrand 4 WAY (4 + 12) DOUBLE DOOR, HORIZONTAL TYPE for light |
301 | 6 WAY (6 + 18) DOUBLE DOOR, HORIZONTAL TYPE(For power) |
302 | Supply and fixing of single pole MCB with sheet steel enclosure, distribution board, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnection, phosphate and powder painted including earthing etc. as required ( But with out MCB/ RCCB/ ISOLATOR) Make-Siemens/Schneider/Legrand8 Way Double Door |
303 | Supplying and fixing 6 amps to 32 amps rating, 240 volts, C series, single poles MCB ofmake or any other equivallent A catagories reputed make ISI marked as approved in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. Make-Siemens/Schneider/Legrand |
304 | 6-32A DP MCB |
305 | 63A DP MCB |
306 | Supplying and fixing 63Amps 4P 415 volts MCBMake-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9in the existing MCB DBin the existing MCB DB complete with connections as per direction of Engg.-in-Charge.(for power BDB & AC ODU, 8 way TPN BDB IC).The MCBshould be Replacement Warranty will be 5 years |
307 | Supplying and fixing 63Amps 4P 415 volts RCCB 30 mAMake-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9in the existing MCB DBin the existing MCB DB complete with connections as per direction of Engg.-in-Charge.(for power BDB & AC ODU, 8 way TPN BDB IC).The MCBshould be Replacement Warranty will be 5 years |
308 | Supplying and fixing 40 Amps rating, 4P, 415 volts, MCB . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. .(4W TPN BDB IC). TheMCBshould be Replacement Warranty will be 5 years |
309 | Supplying and fixing 40 Amps rating, 4P, 415 volts, RCCB 30mA .Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. .(4W TPN BDB IC). TheMCBshould be Replacement Warranty will be 5 years |
310 | EARTHING |
311 | (Earthing)S/IT/C Of Earthing with copper earth plate 600 mm x 600mm x 6 mm thick ISI marked including accessories and providing masonary with cover plate having loccking arrangement and watering pipe etc (WITHcharcoal and salt) as required as per direction of Engg.-in-Charge. |
312 | S/IT/C of materials and installation of GI earth plate 600mmx600mmx6mm thick ISI marked withG. I. nutbolts& washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge.The entire earthing systemshould be Replacement Warranty will be 2 years |
313 | Providing and fixing SWG 6 GI wire on surface or in recess for loop earthing as required.as per direction of Engg.-in-Charge. |
314 | Providing and fixing 25mm x 5 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. |
315 | Providing and fixing 50mm x 6 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. |
316 | Supplying and making brick massonary pedastal with extra super structure including cement plastering etc as required as per direction of Engg.-in-Charge. |
317 | CABLINGAND END TERMINATION |
318 | (CABLINGAND END TERMINATION) Supply of 300 sq mm 3-1/2 core XLPE insulated Aluminium Armoured cables ISI marked.(Make-Polycab/ Havells/ Finolex)(From Transformer to Main Panel,DG) |
319 | Supply of 185 sq mm 3-1/2 core XLPE insulated Aluminium Armoured cables ISI markedMake-Polycab/ Havells/ Finolex |
320 | Supply of 95 sq mm 3-1/2 core XLPE insulated Aluminium Armoured cables ISI marked.(Make-Polycab/ Havells /Finolex)(From Main Panel to Floor Panels) |
321 | Supply of 50 sq mm 3-1/2 core XLPE insulated Aluminium Armoured cables ISI marked.(Make-Polycab/ Havells/ Finolex)(From Panel to Machine panels) |
322 | Supply of 35 sq mm 3 1/2 core XLPE insulated Aluminium Armoured cables ISI marked.(Make-Polycab/ Havells/ Finolex)(For Feeder Pillar) |
323 | Supply of 16 sq mm 4 core XLPE insulated Aluminium Armoured cables ISI marked.(Make-Polycab/ Havells/ Finolext)(For Lift, External light, fire fighting) |
324 | Supply of 6 sq mm 3 core XLPE insulated Aluminium Armoured cables ISI marked.(Make-Polycab/ Havells/ Finolex)(For Lift, External light, fire fighting) |
325 | Supply of 6 sq mm 5 core XLPE insulated Copper Armoured cables ISI marked.(Make-Polycab/ Havells/ Finolex) For machines |
326 | Laying of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of size excedding 120 sq.mm but not exceeding 400 sq.mm direct in ground including excavation , sand cushioning, protective covering and refilling the trench etc. as required. |
327 | Laying of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of size excedding 25 sq.mm but not exceeding 120 sq.mm direct in ground including excavation , sand cushioning, protective covering and refilling the trench etc. as |
328 | Laying and fixing of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of size exceeding 25 sq.mm but not exceeding 120 sq.mm on surface as required. |
329 | Laying of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm direct in ground including excavation, sand cushing, protective covering and refilling the trench etc. as required. |
330 | Laying and fixing of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm on surface as required. |
331 | Supplying and making end termination with brass compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge. |
332 | 3.5 core x300 sq mm |
333 | 3.5 core x95 sq mm |
334 | 4 core x16sq mm |
335 | 3.5 core x50 sq mm |
336 | 3.5 core x35 sq mm |
337 | 3.5 core x185 sq mm |
338 | Providing,fixing and laying of fallowing dia HDPE pipe (medium class) in ground complete withfitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. |
339 | 200 mm dia |
340 | 100 mm dia |
341 | PANELS |
342 | S/F of 96""x72""x36""no 14 SWG sheet metal for main 630amp panel board having 630 amp,36kA FP MCCB as incommer of main & 400A(320-400) 4P MCCB,36Ka LSING for DG followed by 320A 4P Changeover switch,700 amp electrolyte cu bus bar,250 amp FP mccb25 kA-6 No.,125 amp FP mccb25 ka-14 No., 100A FP MCCB 16 KA-10 No,63A FP MCB,10ka-12No,40A DP MCB,10ka-8 No.s ,32A 4P MCB,10ka-6 No.s as Outgoing with MFM 8 NOS ,thirty sixnos led indicator,65KA SPD TYPE 1 4P followed by 63A 4P MCB,C,10KA,Drum insulator,transparent isolation glass,danger Board and Rubber Mat as per the direction of site engineer in charge (make - Siemens/ legrand/Schneider)(Main Panel) |
343 | S/F of 40""x36""x10""no 14 SWG sheet metal for main 250amp panel board having250 amp MCCB 25 KA as incommer,250 amp electrolyte cu bus bar,63 amp FP mcb -8No.,40 amp DP mcb-6No. as Outgoing with MFM, toggler switch,40KA SPD TYPE 2 4P followed by 32A 4P MCB,C,10KA,three nos led indicator,Drum insulator,transparent isolation glass,danger Board and Rubber Mat as per the direction of site engineer in charge (make Siemens/ legrand/Schneider)(Floor Panel(POWER)) |
344 | S/F of 40""x36""x10"" in inchno 14 SWG sheet metal for main 250amp panel board having250 amp MCCB 25 KA as incommer,250 amp electrolyte cu bus bar,32 amp FP mcb,10ka -10 No.,6-32 amp DP mcb,10ka-10 No. as Outgoing with 40KA SPD TYPE 2 4P, followed by 32A 4P MCB,C,10KA, MFM, toggler switch,three nos led indicator,Drum insulator,transparent isolation glass,danger Board and Rubber Mat as per the direction of site engineer in charge (make Siemens/ legrand/Schneider(POWER PANEL 2) (EV Charging,machine ev) |
345 | S/F of 40""x36""x10"" in inchno 14 SWG sheet metal for main 250amp panel board having250 amp MCCB 25 KA as incommer,250 amp electrolyte cu bus bar,32 amp FP mcb,10ka -4 No.,63 amp FP mcb,10ka -6 No.6-32 amp DP mcb,10ka-4 No.,.63 amp DP mcb,10ka-6 No as Outgoing with 40KA SPD TYPE 2 4P, followed by 32A 4P MCB,C,10KA, MFM, toggler switch,three nos led indicator,Drum insulator,transparent isolation glass,danger Board and Rubber Mat as per the direction of site engineer in charge (make Siemens/ legrand/Schneider(POWER PANEL 2) (ELECTRICAL 1 lab) |
346 | S/F of 40""x36""x10"" in inchno 14 SWG sheet metal for main 250amp panel board having250 amp MCCB 25 KA as incommer,250 amp electrolyte cu bus bar,32 amp FP mcb,10ka -5 No.,63 amp FP mcb,10ka -4,100 amp FP mcb,10ka -4 No, 6-32 amp DP mcb,10ka-6 No. as Outgoing with 40KA SPD TYPE 2 4P followed by 32A 4P MCB,C,10KA, MFM, toggler switch,three nos led indicator,Drum insulator,transparent isolation glass,danger Board and Rubber Mat as per the direction of site engineer in charge (make Siemens/ legrand/Schneider(POWER PANEL 2) (,CNC) |
347 | S/F of 30""x36""x10""no 16/18 SWG sheet metal for main 100amp panel board having100 amp FP MCCB 16 kAas incommer,100 amp electrolyte cu bus bar,32 amp FP mcb -6No.,63A DP MCB,C,10kA-6 No. as Outgoing with 40KA SPD TYPE 2 4P followed by 32A 4P MCB,C,10KA , MFM, toggler switch,three nos led indicator,Drum insulator,transparent isolation glass,danger Board and Rubber Mat as per the direction of site engineer in charge (make Siemens/ legrand/Schneider) (Light panel) |
348 | S/F of 30""x36""x10""no 16/18 SWG sheet metal for main 125amp panel board having125 amp MCCB 25 KA as incommer,125 amp electrolyte cu bus ba-1 Set, 16-32A,4P MCB.10KA,C- 10 No,6-32A DP MCB,10KA,C-6 No as Outgoing with 40KA SPD TYPE 2 4P followed by 32A 4P MCB,C,10KA, MFM, toggler switch,three nos led indicator,Drum insulator,transparent isolation glass,danger Board and Rubber Mat as per the direction of site engineer in charge (make Siemens/ legrand/Schneider)(Lab Machine Panel)(INST. MACHINE,ELECTRICIAN-2LAB ONLY) |
349 | S/I/T&Commissioning of LT OUT DOOR FLOOR mounted cubical type IP66 based panelmade out by 2mm CRCA steel sheet duly derusted & pented by simens gray powder cote paint is designed asG.A drawing. (FOR USE) with 63A TPN MCB 01 NO,1 no. Astronomical digital timer, AUTO MANUAL(with start and stop push button) SELECTOR 32 A 3P contactor, OLR,RYB,ON,OFF trip indication, Type-II SPD 40ka ,,04 nos 10A 4P MCB, 2 nos.32 DP MCB as outgoingMake-LEGRAND/ Siemens/ Schneider as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period 2 years ofacceptance of materials |
350 | S/F of 30""x24""x10""no 16/18 SWG sheet metal for main 63amp panel board having 63A Amp 16KA 4P MCCB,25KA TMR as incommer,100 amp electrolyte cu bus ba-1 Set, 63A Amp FP RCCB 300mA- 1 No,25A Amp DP RCCB 30mA- 2 No,6-32ADP MCB 10KA,C-6 No as Outgoing with 40KA SPD TYPE 2 4P followed by 32A 4P MCB,C,10KA,MFM, toggler switch,three nos led indicator,Drum insulator,transparent isolation glass,danger Board and Rubber Mat as per the direction of site engineer in charge (make Siemens/ legrand/Schneider)(Lift Panel,ups panel-GF/1F) |
351 | (CABLE TRAY) HOT DIPP GALVANIZED(GC) AS PER EN-ISO-1461 ,CARBON STEEL WIRE MESH CABLE TRAYS with internal dimensions ofsize 54mm(H) x 200mm(W),of Legrand - Cablofil make /C&S/OBO.The Load bearing capacity of the Cable Traysshould be minimum of104.8Kg/meter at the span of1.5Meter as per UL specifications.(With all accessories,bend,cover,supporter)WITH REQUIRED SIZED JUNCTION BOX ,COVER CONNECTORas required as per direction of Engg.-in-Charge. |
352 | HOT DIPP GALVANIZED(GC) AS PER EN-ISO-1461 ,CARBON STEEL WIRE MESH CABLE TRAYS with internal dimensions ofsize 54mm(H) x 300mm(W),of Legrand - Cablofil make /C&S/OBO .The Load bearing capacity of the Cable Traysshould be minimum of104.8Kg/meter at the span of1.5Meter as per UL specifications.(With all accessories,bend,cover,supporter)WITH REQUIRED SIZED JUNCTION BOX ,COVER CONNECTORas required as per direction of Engg.-in-Charge. |
353 | HOT DIPP GALVANIZED(GC) AS PER EN-ISO-1461 ,CARBON STEEL WIRE MESH CABLE TRAYS with internal dimensions ofsize 54mm(H) x 400mm(W),ofLegrand - Cablofil make /C&S/OBO.The Load bearing capacity of the Cable Traysshould be minimum of104.8Kg/meter at the span of1.5Meter as per UL specifications.(With all accessories,bend,cover,supporter)WITH REQUIRED SIZED JUNCTION BOX ,COVER CONNECTORas required as per direction of Engg.-in-Charge. |
354 | HOT DIPP GALVANIZED(GC) AS PER EN-ISO-1461 , FLOOR RACE WAY WITH JUNCTION with internal dimensions ofsize 34mm(H) x 225mm(W),ofLegrand - Cablofil make /C&S/OBO .The Load bearing capacity of the Cable Traysshould be minimum of104.8Kg/meter at the span of1.5Meter as per UL specifications.(With all accessories,bend,cover,supporter)WITH REQUIRED SIZED JUNCTION BOX ,COVER CONNECTORas required as per direction of Engg.-in-Charge. |
355 | HOT DIPP GALVANIZED(GC) AS PER EN-ISO-1461 ,CARBON STEEL WIRE MESH CABLE TRAYS with internal dimensions ofsize 54mm(H) x 50mm(W),of Legrand - Cablofil make /C&S/OBO.The Load bearing capacity of the Cable Traysshould be minimum of104.8Kg/meter at the span of1.5Meter as per UL specifications.(With all accessories,bend,cover,supporter)WITH REQUIRED SIZED JUNCTION BOX ,COVER CONNECTORas required as per direction of Engg.-in-Charge. |
356 | ELV PART |
357 | Supplying and fixing of Hybrid EPABX system equipped with 40 Analog extensions and 6 Analog Trunk, including required hardware and software etc as reqd. Make-Matrix/Siemens/Coral |
358 | Supplying and drawing 4 pair TelephoneWIRE protected with PVC sheath in the with surface/ recessed steel/ PVC conduit (Make- NORPACK or Eq.) as required as per direction of Engg.-in-Charge. |
359 | Supplying and telephone socket socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required as per direction of Engg.-in-Charge. Make-Legrand/Havells/panasonic/schneider |
360 | Supply and installation of 24 Port Layer2 Giga (10/100/1000BaseT) PoESwitch with 4 x 1Gig SFP Port , Switching Capacity56 Gbps, Throughput 41.7 Mpps ,Management Port1 x RJ 45 Console port,PoE power budget 270 Watt, Switch should support IEEE 802.3af & IEEE 802.3at standard ,MAC Address16K , Jumbo Frame 12K ,TemperatureWorking 0°C~50°C, storage -40°C~70°C, Power Supply AC: 100~240VAC. Digisol (Model No. DG-GS1528HPE-P)/Netgear/Cisco |
361 | Supplying & Commissioning ofTelephone Hand Setas per direction of Engg.-in-Charge. Make-Panasonic/Beetel |
362 | Supplying and drawing RG6 TV Cable protected with PVC sheath in the with surface/ recessed steel/ PVC conduit (Make- NORPACK or Eq.) as required as per direction of Engg.-in-Charge. Make-Legrand or equievalant. |
363 | Supplying and TV socketon the existing modular plate & switch box including connections but excluding modular plate etc. as required as per direction of Engg.-in-Charge. Make-Legrand/Havells/panasonic/schneider |
364 | Supply & Laying of RG59+ 3 Core cable using Rigid PVC Pipe in concealed manner per running metre of cable laid.Make-Legrand or equievalant. |
365 | Supply, Installation,Testing & Commisioning of 64 Chanel 4K H.265 Pro NVR with support 8*SATA HDD.Make: Honeywell series 20/Pelco/Axis |
366 | Supply & Laying of Cat6 23Awg UTP Cable, through existing conduit,Make: Legrand/Panduit/Systimax |
367 | Supply & fixing of RJ-45Jack of Category 6 with Dual-port British-style Face plate 86x86 mm with Curveture and wall mount boxMake: Legrand/Panduit/Systimax |
368 | Supply & fixing of Cat6 24 Port Loaded Patch Panel:Make: Legrand/Panduit/Systimax |
369 | Supply & Installation of Cat6 Factory crimpped moulded patchcord, 1mtr, Make: Legrand/Panduit/Systimax |
370 | Supply & Installation of Cat6 Factory crimpped moulded patchcord, 2mtr.Make: Legrand/Panduit/Systimax |
371 | Supply & Installation of 6F Single Mode Armoured FO Cable through existing conduit.Make: Legrand/Panduit/Systimax |
372 | Supply and Installation of 6 Port Rack Mount Draw Type LIU loaded with SM SC Adaptors and Pigtails including core splicing and connnectrisation. Make: R&M / Legrand / Panduit |
373 | Supply & Installation of Single Mode SC-LC Type OFC Patch Cord, 2mtr length. Make: Digisol/Cisco/HP |
374 | Supply & Installation of 1000Base LX Fiber Transceiver. Make: Digisol/Cisco/HP |
375 | Supply & Installation of 9U/500Wall Mount Rack with FAN, PDU, Cable manager and H/W Pkt. Make : Netrack/Valrack/Rittal |
376 | Supply & Installation of 24U/600D Floor Standing Rack With FAN, PDU, Cable manager and H/W Pkt. Make: Netrack/Valrack/Rittal |
377 | Supply,installation, testing and commissioning of vandal proof 4 MP Dome/BulletCamera with 25 Mtrs IR Range Make-Honeywell series 20/Pelco/Axis |
378 | Supply & Installation of surveliance 8 TB HDD .Make:WD/Segate/Toshiba |
379 | Supply & installation of 55"" IPS Ultra HD AI for 24x7 application TV.Make:LG/Samsung/Sony |
380 | LIGHTENING PROTECTION SYSTEM |
381 | Lightning Protection :- Supply of 8 mm Aluminum Round Conductor.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn |
382 | Supply of Roof conductor holder for parapet- Polyamide Conductor holder:With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder.Weather and temperature resistant from -35 to +90 degree Celsius tested. Conductor holder @ 1 meter distance.Tested as per IEC 62561.as per direction of engineer in charge.Make-OBO/Dehn |
383 | Supply of Polyamide roof cable holder for flat roof: DIN 48829 Form B1. Closed form with bottom. Filling weight 1Kg (frost-resistant concrete). Sleeve from polyethylene, black @ 1 meter distance. Tested as per IEC 62561. Make-OBO/Dehn |
384 | Supply of Connector: For T cross and parallel connectors. Quick installation using hexagonal bolt M10X30 high-grade hot dip galvanised. Tested as per IEC 62561.(2nos/expansion piece ).Make-OBO/Dehn |
385 | Supply of 1 mtr vertical air terminal with mounting accessories on the flat surface to meet the requirements of IS/IEC 62305. Tested for Electrical , mechanical and chemical as per IEC 62561. Tested for 100kA lightning current. Make-OBO/Dehn |
386 | Supply of Vertical air terminal with accessories: Providing of Air terminals as per IS-IEC -62305 part-3 Nominal size Ø10/16 mm aluminium rod: 3 Mtr Airterminal: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) Suitable for high wind load. Tested as per IEC 62561. Make-OBO/Dehn |
387 | Supply for Providing of Stand for Fang Fix system 16 kg with base and clamp ,made up of frost resistant concrete and clamp tested upto 100KA lightning current . Make-OBO/Dehn |
388 | Supply for Providing of Stand for Fang Fix system 16 kg made up of frost resistant concrete. Make-OBO/Dehn |
389 | Supply of Test Joint (Folding Clamp) suitable to connect 8mm round conductor and max by 30x3 mm GI strip as specified in drawing and directed by Engineer. Tested for 100kA lightning current. Make-OBO/Dehn |
390 | Supply of IP 66 Poly Propylene Junction Box. Installation at 1Mtr Height for Test Joint .Internal dimensions: 100x100x48 mm Make-OBO/Dehn |
391 | Supply of Galvanised Steel Flat 30X3 mm thickness from earth electrode directly in ground as required. Flat conductor Hot Dipped Galvanized. Tested as per IEC 62561. Make-OBO/Dehn |
392 | Supply for Providing of Cross connector for Flat: Suitable for 30mm Galvanised steel strip. Installed with 4 nos of hexagonal plate. Tested for 100kA lightning current. Make-OBO/Dehn |
393 | Supply of flat conductor holder- Fit: FL 30, With mounting hole 6.2 x 22 mm, With 2 cylinder bolts M6 x 16 and over-piece from hot-dip galvanised steel, Bottom section from polyamide, black. Tested as per IEC 62561. Make-OBO/Dehn |
394 | Supply for Providing of Plastic Corrosion Protection strip: Approx 1.1 mm thick. Width 50mm. Made of petrolatum- coated chemical fibre fabric. Make-OBO/Dehn |
395 | Supply of UL Listed maintenance free ,Low carbon copper coated earth rod of 3 metre electrode having diameter of 17.2mm with copper coating thickness of 250micron tested as per IEC 62561-2 Make-OBO/Dehn |
396 | Supply of universal clamp made of SS to connect rod with flat conductor Make-OBO/Dehn |
397 | Supply of Earth conductivity enhancing mineral compound shall be of 25 kg/pit tested as per IEC 62561-7,TCLP tested Make-OBO/Dehn |
398 | Supply of The above arrangements shall be provided with Heavy duty earth champer of 5000kg load bearing capacity to ensure the safety of earthing system Make-OBO/Dehn |
399 | Installation of The above arrangements including all accessories as per Direction of Engg. In charge. |
400 | EXTERNAL ILLUMINATION |
401 | S/F of Street light- 90Wnew generation energy saving & environmental friendly long life versatile pressure die-cast alluminium IP66 roadway luminaire with high power LED as light source with acrylic cover(Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/ Orient/ Bajaj) (5Years Warranty) |
402 | SITC of 6 mtr long hot dip Galvanized Octagonal pole manufactured from HT steel as per BS EN10025/IS 2062 having minimum yield strength of 350 N/ SQMM having top dia of 70 MM A/F and bottom dia of 130 MM A/F of 3 mm thick or more , base plate as per IS 2062 complete with 4 nos.En 8 grade foundation bolts to withstand basicwind speed of 180 KM/HR wind speed (As per structural calculation of pole manufacturer )or more (Make of poles: Utkarsh/Bajaj/RR Ispat as per direction of Engg. in Charge. |
403 | Installation of pole by making the suitable size foundation by embeding the pole 1 mtr into the ground with necessary civil work and fixing the light on the poleequievalant make ISI marked as approved as per direction of Engg. in Charge. |
404 | Supplying, Erection, Fixing, connection & testing of LED BOUNDRY WALLLight of elegant look (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/ Orient/ Bajaj) 45 W LED street light having die cast aluminium housing with toughened glasshaving lumen efficacy of 110 lm/w or more (As per LM 79 report of third party NABL lab) ,IP 65 protection or more , LED street lightmodel having warrantied for a period of 5 years .The luminaire should be supplied along with bracketmaintenance free for inspection as required as per direction of Engg.-in-Charge. |
405 | Supplying, Erection, Fixing, connection & testing of Panasonic 40 LED GATE Light of(Make: Panasonic/ LT/ Havells /Philips/ Wipro /Crompton/ Orient/ Bajaj) maintenance free having 2 years warrantyG.I P ipewith braket including MCB box & including with foundation as per the Drawing for inspection as required & as perdirection of Engg.-in-Charge. |
406 | S/IT/C of materials and installation of GI earth plate 600mmx600mmx6mm thick ISI marked withG. I. nutbolts& washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge.The entire earthing systemshould be Replacement Warranty will be 2 years |
407 | Providing and fixing 4 mm dia copper wire on surface or in recess for loop earthing as required as per direction of Engg.-in-Charge. |
408 | Providing and fixing 25mm x 5 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. |
409 | Supplying,laying of 3cx2.5 sq.mm copper flexible cable with insulated cover of reputed make,ISI marked with all other concerned materials as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials |
410 | Providing,fixing and laying of fallowing dia PN10 HDPE pipe (medium class) in ground complete withfitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. |
411 | 32mm |
412 | 20 PASSENGER LIFT WITH WIRRING(1.1) |
413 | Supply,Installation, Testing & Commissioning of of 20 Passenger lift gearless withMachine roomCapacity,Elevator G+2 Floors with ACVVVF drive/Control for constant load of 1360 kg ARD 1.25 MPS, SS honeycomb interior ,2hr fire rated door with simplex operation without attendant car position indicators,battery operated alarm bell & emegency light,SS honeycombfinish door finished car interior, recess Granite flooring ,power operated centre opening automatic sliding SS honeycombfinishdoors for car entrance & hoist way entrance etc . Machine beams,buffer support channels,facia plate including sills pit ladder metal screen in Elevator pit etc.as per specifiaction including cost of (i)Overload detection,(ii)Voice announcement,(iii) Intercom,(iv)Braille Buttons with all Civil & Electrical works required for installation of Elevator in the existing lift well and machine room,scaffolding ,floor cuttingincluding Fireman"s switch complete in all respect.The Elevator should be suitable for physically handicapped person. make:OTIS/Mitsubishi/ kone/Schindler/Thysenkrupp |
414 | UPS SYSTEM(For LAB & COMMON AREA) |
415 | Supply ,installation ,testing & commissioning of20KVA Parallel UPS SYSTEM WITH IGBT based inverter system, true online double conversion system,inbuilt isolation transformer & automatic phase sicuency correctorof 3ph in put to 3 ph output,415V, with built in BMS with battery back up up to 30 minutes with MS Rack for battery Housing, DC cable 7 Mtr with SFU and links for installation (Battery required: 12V, 65AH, 32 No.s) protection for fault by OL,UV,EF,GF,OC,Ph.(Make:Numeric/ RELLIO/ Emersion) LOAD OF LAB) as per direction of Engg.-in-Charge. Warrentee period of all accessories & component & systemmust be 2 years & compelete test certificate must be submitted along with upsincluding component list & SLD. |
416 | 160 KVA DG |
417 | Supply, Transportation, erection, testing and commissioning of 3 Phase, 415V, 50Hz, water cooled multi cylinder diesel generator set with alternator of160KVA ( Make -Kirloskar / Jakson / Mahindra) out put contineous rating directly coupled Engine and Alternator with guard and mounted on a common base plate of Robust construction and complete with AMF panel having IP-52 protection, Acoustic Enclosure as per CPCB norms , sound absorbing material, to restrict sound level up to 75 dB up to 1 mtr distance and as per CPCB norms etc as per following specifications mentioned below. Warrentee period must be 2 years. ALTERNATOR:The alternator of the output rating shall be 3 Phase, 415V, 50Hz, Ac , 0.8 P.F. lagging at 1500 RPM. The alternator is self excited, self regulated, and shall confirm to IS: 13364 of 1992 with regulation of +5% from no load to full load. degree of protections shall be IP21. |
418 | ENGINE: Diesel Engine start, developing suitableBHP output at 1500 RPM with mechanical / electronic governing so as to enable the alternator to give 160KVA continuous output at 0.8 P.F. lagging at NTP conditions. The diesel engine shall be capable of providing 10% O/L for 1 Hr for every 11 Hrs of continuous running at full load. The engine with 1st filling of oil and Diesel etc. 01. Exhaust pipe of required size and length with insulation or clading. 02. Diesel tank suitable for 8 to 10 Hours running capacity. 03. Residential Silencer. 04. SMF Batteries with leads as per the Manufacturer standards. AMF PANEL: Cubical, Compartmentalized, AMF Panel Baord with all Power & Control Contractors, Switches, Meters and other accessories, Internal Wiring, connection, inter-connection etc. for Trouble Free smooth function for 160KVA DG Set complete with Battery Charger & leads as required. |
419 | BASE PLATE: Common Base Plate of required size for mounting of Engine Alternator Set fabricated from MS Channerl and vibration damping arrangement with cushy foor mounting including paintng etc. as required. FOUNDATION: Suitable size Cement Concrete (1:2:4) foundation duly plastered and finished with neat coat Cement as required along withsmoke exhaust system piping including base frame of structure & lightening protection system. *It also includes 2 noscopper plate earthing for body and 4 nos copper plate earthing for neutral, control cable of 15mtr 2.5sqmm 6core , civil foundation work. (The Manufacturing of DG set shall not in any case be more than six months old from the date of award of work) |
420 | SPLIT AC SYSTEM |
421 | Supply of A,C with indoor and outdoor unit |
422 | 2.0 TR high wall 5 satr inverter type split A.C (Make:Toshiba/Hitachi/Carrier/Diakin/Voltas/LG/Mitsubishi |
423 | REFRIGRANT PIPING |
424 | Supply,installation of hard/soft copper refregrant piping,complete with fitting of bends and other nesessary material to complete the job. |
425 | 1 TR to 3 TR high wall split A.C |
426 | FRAME WORK |
427 | Supply,installation & fabrication ofMS base frame for both indoor and outdoor unit and other nesessary material to complete the job. |
428 | 1 TR to 3 TR high wall split A.C |
429 | DRAIN PIPING |
430 | Supply,installation & fabrication ofInsulated drain water piping from indoor to nearestdrain point separate to alland other nesessary material to complete the job. |
431 | 25mm nom. Dia pipe,B1 |
432 | CONTROL CABLE |
433 | Supply,laying of control cableand other nesessary material to complete the job. |
434 | For 1 TR to3 TR high wall split A.C |
435 | Supply and fixing of 5kVA Voltage stabilizer (Make-V-Guard/Microtek/Shakti |
436 | FIREFIGHTING SYSTEM |
437 | FIRE FIGHTING -: Supplying, Installing, Testing and commissioning of electrical motor driven booster pump of Monoblock type capable to deliver 900LPM at 35MWC. The pump shall be coupled to TEFC motor of suitable HP with speed of 2900RPM and complete set shall mounted on common base frame as per direction of engineer in charge Make-Wilo/Kirloskar/KSB |
438 | Supply, installation, testing and commissioning of Floor/Wall mounted sectionalised, front operated top entry dust and vermin proof M.V.Panel Boards suitable for operation at 415V, 3 phase, 4 wire, 50Hz distribution system fabricated out of 2.0 mm thick CRCA sheet, insulated busbar with heat shrienkable PVC sleeve, base frame, complete with all accessories including interconnections, earth bus etc as required comprising of One (1)- 63 Amp, 10 KA,TPN (Class-C) MCB with 3 Nos Phase indicating lamps with control fuse/ MCB,Digital Voltmeter with selector switch. DOL starter with O/L and Single Phasing Preventor suitable for 7.5 HP motor. ON/OFF indication lamps, Auto manual switch and ON/OFF push button.as per direction of engineer in charge Control panel for fire pumps for auto action.Make of switchgear-Legrand/Schneider/Siemens |
439 | SITC of FRLS, PVC outer sheateh, steel armoured, aluminium, 1100v grade power cables with glands etc. The minimum size of the cables shall as mentioned below as per direction of engineer in charge3.5C x 16 mmsq Make-Polycab/ Havells |
440 | 2 C x 1.5 mmsq |
441 | G.I. earthing strips of 25mm x 6mm thick, strip shall be run for PUMPS |
442 | Supplying, Installing, Testing and commissioning of waffer type C.I. Non-return valves as per with required flanges, nuts, bolts and gaskets etc. complete.as per direction of engineer in charg100 mm nominal dia. Make-Zoloto/Kartar/Kirloskar |
443 | Supplying, Installing, Testing and commissioning of CI butterfly valves (PN 10) as per BS 5155 slim seal standard lever operated type with required flanges, nuts, bolts etc. complete 100 mm nominal diaMake-Zoloto/Kartar/Kirloskar |
444 | Supplying, Installing, Testing and commissioning C.I flanged "Y" type strainer with SS mesh, suitable flanges, nuts, bolts, gaskets etc. completeas per direction of engineer in charge100mm diaMake-Zoloto/Kartar/Kirloskar |
445 | SITC of Gun metal chrome finished Ball valves with fittings of screwed end type.as per direction of engineer in charge 15mm dia |
446 | Supply and installaion of pressure switches of suitable range for pump sets.as per direction of engineer in chargeMake-Indfoss/Grundfoss |
447 | Supply and installaion of pressure gauges of suitable range for pump sets.as per direction of engineer in charge Make-H.Guru/G.Guru |
448 | Supplying, Installing, Testing and commissioning of MS PIPEsw conforming to IS 1239 Pt - I Heavy grade with fittings such as Reducers, Tees, elbows, flanges with painting of 1 coats of red oxide primer and 2 coats of PO red paint as per direction of engineer in charge.Make-TATA/Sail/Jindal100 mm nominal dia |
449 | 80 mm nominal dia |
450 | 25 mm |
451 | Supplying, erecting and commissioning of Landing Hydrants comprising of the following in the Fire duct.as per direction of engineer in charge Single headed hydrant valve as per IS 5290, made of SS with 63 mm dia instantaneous outlef of 80 mm dia flanged and hand wheels etc. complete. Make-Newage/Minimax/Fireshield |
452 | 15 M long, 63mm dia RRL hose with instataneuos SS couplings and hoses shall be stored in side the hose cbinet Make-Newage/Minimax/Fireshield |
453 | 1no SS short branch pipe with nozzle. Make-Newage/Minimax/Fireshield |
454 | Hose reel drum of swinging type with 19mm dia Rubber braided hose of 30M. Length with shut off nozzle complete. Make-Newage/Minimax/Fireshield |
455 | M.S. Hose cabinet stand moulded type fabricated out of M.S. sheet of 16 SWG with glass fronted (4mm thick glass with rubber beeding) door and size of the cabinet includes suitable all fasteners etc. and cabinet shall be powder coated of approved colour both inside and out side sizes 650 x 500 x 250 Make-Newage/Minimax/Fireshield |
456 | SITC of fire brigade inlet inlet connection of 2 way with 2nos 63 mm dia built - in Gun metal Non - return valves instantaneous coupling type arranged on 100 mm dia.as per direction of engineer in charge Make-Newage/Minimax/Fireshield |
457 | Supplying, Installing, Testing and commissioning CI butterfly valves (PN 10) as per BS 5155 slim seal standard lever operated type with required flanges, nuts, bolts etc. complete.as per direction of engineer in charge. Make-Zoloto/Kartar/Kirloskar100mm nominal dia |
458 | Supplying, Installing, Testing and commissioning of waffer type C.I. Non-return valves as per with required flanges, nuts, bolts and gaskets etc. complete.as per direction of engineer in charge.Make-Zoloto/Kartar/Kirloskar100mm nominal dia |
459 | Supplying and fixing of automatic air release valve with unions etc. complete.as per direction of engineer in charge |
460 | SITC of Gun metal chrome finished Ball valves with fittings of screwed end type.as per direction of engineer in charge25 mm dia |
461 | Supplying, installing and commissioning portable Fire extinguishers of following type & capacity as per direction of engineer in charge Carbon-di-oxide type the extinguisher of 4.5 kgs. Capacity, CO2 gas filled in brand new seamiess cylinder with powder coated finish, with wheel type valve, discharge nozzle, bend & horn, wall mounting bracket etc. complete confirming to IS : 15683.Make-Safex/Fireshield/Ceasefire |
462 | ABC stored pressure type fire extinguisher of 6 kgs. Capacity with intial filling in brand new cylinder with powder coated finish, fitted with Gun metal union, discharge hose, wall mounting bracket etc. complete confirming to IS : 15683 Make-Safex/Fireshield/Ceasefire |
463 | Fire buckets round bottom type enamel painted, white inside & Red out side and Letter "FIRE" in black out side and handle with mounting bracket. |
464 | Fire bucket stand fabricated by MS angles to install 2 Nos. of buckets. |
465 | Supplying andinstalling of in position the following type of sign boards made out of 3mm thick "Opaque" PVC foam board with computer cut, PVC reflective self adhesive vinyle painted foam board, complete with mirror fasteners. Signage with printed"IN CASE OF FIRE, USE STAIRS UNLESS INSTRUCTED OTHERWISE" of 1.5cm height letters in red with white back ground. The size of the board shall be 25cm x 30 cm and shall be fixed at the height of 2 mts. from finished floor near Manual call points. |
466 | Floor identification signage ( i.e., GROUND FLOOR …etc.) at each stair enclosure on every floor, indicating the floor number in words, lettering size shall be 7.5 cm with contrasting color from back ground. Size shall be 15cm x 60cm. |
467 | Fire Exit signageat each stair on every floor, indicating the direction of fire exit, lettering size shall be 7.5 cm with contrasting color from back ground. Size shall be 15cm x 60cm. |
468 | Providing and Fixing of Mechanical Foam type fire extinguisher 9Lts. Capacity, with initial filling in brand new cylinder with powder coated finish, fitted with Gun metal union, high pressure CO2 gas cartridge, hose and ABS type branch pipe and wall mounting bracket etc. complete, confirming to IS: 15683.Make-Safex/Fireshield/Ceasefire |
469 | P.H. WORK Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor upvc pipesconforming to ASTM-D-1785/89 (Sch-80) and pipe fittings of the following nominal bore with clamps including making good the wall, ceilingand floor all complete as per specification and direction of the Engineer in charge.In Ground Floor )(Supreme/Ori Plast/Finolex/Ashirvad) |
470 | 40mm dia UPVC ASTM pipe (sch-80) (Supreme/Ori Plast/ Finolex/ Ashirvad) |
471 | 50mm dia UPVC ASTM pipe (sch-80) |
472 | Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor CPVC pipesconforming to IS:15778 having thermal stability for hot and cold water supply, including all CPVC plain and brassthreaded fittings including fixing the pipe with clamps at 1.00. spacing. This includes Jointing of pipes & fittings with one step CPVC solvent cement and testing of Jointsall complete as per specification and direction of the Engineer in charge. )(Supreme/Ori Plast/Finolex/Ashirvad) |
473 | In ground floor |
474 | 20mm dia CPVC pipe |
475 | 25mm dia CPVC pipe |
476 | 32mm dia CPVC pipe |
477 | In First floor |
478 | 20mm dia CPVC pipe |
479 | 25mm dia CPVC pipe |
480 | 32mm dia CPVC pipe |
481 | In 2nd floor |
482 | 20mm dia CPVC pipe |
483 | 25mm dia CPVC pipe |
484 | 32mm dia CPVC pipe |
485 | In 3rd floor |
486 | 40mm dia UPVC ASTM pipe(sch-80)(Supreme/Ori Plast/Finolex/Ashirvad) |
487 | 50mm dia UPVC ASTM pipe (sch-80) |
488 | Supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking GI pipes and fittings/ PVC pipes and fittings etc all complete as per PH specification and direction of the Engineer in charge. 250mmthick wall |
489 | In Ground Floor |
490 | In First Floor |
491 | In 2nd Floor |
492 | Supplying all materials, labour, T&P and cutting hole in R.C.C floors, roofs, etc upto 19 cm thick for passing GI pipes / PVC pipes and fittings etc and repairing the holes after insertion of pipes etc with cement concrete (1:2:4) including finishing complete so as to make it leak proof as per direction of theEngineer in charge. |
493 | In Ground Floor |
494 | In First Floor |
495 | In 2nd Floor |
496 | In 3rd Floor |
497 | Supplying allmaterials, labour, T&P and cutting grooves in pucca floors and walls for takingGI/ PVC pipes and making good the damages as per the direction of the Engineer in charge. |
498 | In Ground Floor |
499 | In First Floor |
500 | In 2nd Floor |
501 | Supplying all materials, labour, T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all jointing materials complete as per specification and direction of the Engineer in charge.(C.P.fittings are Jaquar make) |
502 | 15 mm dia CP two way Bib cock (Jaquar)CON-CHR-041KN |
503 | 15mm dia CP Health foucet (Hindware F160013CP) |
504 | 15 mm dia CP Long bodyBib cock(Jaquar)CON-CHR-107KN |
505 | 15mm dia CP angle stop cock(Jaquar)CON-CHR-053KN |
506 | 20mm dia CP concealed stop cock(Jaquar)CON-CHR-083KN |
507 | Pillar cock Long neck with Aerator (Jaquar)CON-CHR-021KN |
508 | 25mm dia brass or gun metal fullway valve(Shakti Make) |
509 | 40mm dia brass or gun metal fullway valve(Shakti Make) |
510 | 32mm dia brass or gun metal fullway valve(Shakti Make) |
511 | 50mm dia brass or gun metal fullway valve(Shakti Make) |
512 | 15mm dia CP flange |
513 | 15mm dia CP extension piece |
514 | Sink cock(Jaquar)CON-CHR-349KN |
515 | Grab Bar Left 90° Angle white(Cera)No.82210104 |
516 | Urinal Flush Valve(Jaquar)PRS-CHR-073 (At Gents Urinal) |
517 | Supplying all materials, labour, T&P and fitting and fixing CP shower with 15mm or 20mm inlet with CP shower arm including polishing all complete as per specification and direction of the Engineer in charge. 15mm dia CP revolving shower With shower arm(Jaquar)OHS-CHR-1985+SHA-CHR-477 |
518 | Supplying all materials, labour, T&P and fitting and fixing10 litres capacity low level flushing cistern with a pair of cast iron or M.S brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle, unions and couplings for connection with inlet, outlet and overflow pipes,32mm dia CP flush bend,15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connecting the inlet pipe with supply main etc all complete as per specification and direction of the Engineer in charge. 10 litres capacity pvc low level cistern with 32mm dia CP long flush bendSlimline white |
519 | Supplying all materials , labour, T&P and fixing rotational mouldedpolyethylene cylindrical vertical water storage tanks conforming to IS:12701/1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc. including hoisting upto a height of 5 metres above ground level and placing the tank to the required position and providing 5.40 mtr. lengthx0.25 mtr widthFly ashbrickwork in cement mortar (1:6) of 0.46m height in staging and 0.13mtr thick circular protection wall of 0.46mtr height to support the tank,12mm thick cement plaster in cement mortar (1:6) over brick work, RCC slab of size 1.60mX1.60m and 0.10m thick ,RCC beam of 0.25mx0.30m and 2.60m average length in cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips including centering and shuttering, watering, curing , cost of all materials, conveyance of all materials to worksite , payment of royalty, all taxesetc.all complete as per approved drawing , P.H. specification and direction of Engineer-in-charge.( Sintex/Supreem/Rotomax) |
520 | 2000 ltrs capacity rotational moulded polyethylene cylindrical vertical water storage tank .In 3rd floor |
521 | Supplying all materials, labour, T&P and fitting and fixing PVC soil waste ventilating pipes and fittings of the following with suitable clamps as per specification and direction of the Engineer in charge 100mm U-PVC Pipe(Ori Plast/Finolex/Supreme Make) |
522 | 110mm U-PVC D/Jn door(Ori Plast/Finolex/Supreme Make) |
523 | 75mm U-PVC Plain tee(Ori Plast/Finolex/Supreme Make) |
524 | 110mm U-PVC Plain tee(Ori Plast/Finolex/Supreme Make) |
525 | 110mm U-PVC door bend(Ori Plast/Finolex/Supreme Make) |
526 | 110mm U-PVC Plain bend(Ori Plast/Finolex/Supreme Make) |
527 | 110mm U-PVC‘P’ Trap(Ori Plast/Finolex/Supreme Make) |
528 | 110mm U-PVC offset without ear(Ori Plast/Finolex/Supreme Make) |
529 | 100mm diaCowl |
530 | 125mm dia grating |
531 | 110mm U-PVC Socket(Ori Plast/Finolex/Supreme Make) |
532 | 75mm dia Pipe (Ori Plast/Finolex/Supreme Make) |
533 | 75mm dia Plain Bend |
534 | 75mm U-PVC Socket(Ori Plast/Finolex/Supreme Make) |
535 | Clamp |
536 | Supplying all materials , labour, T&P andfixing Vitreous chinawater closet ,squattingpan ( Indian type W.C. pan / Orissa pattern squatting pan ) duly embedded in cement concrete 1:5:10 using hard granite metal 4cm nominal sizeincluding fixing a pair of vitreous china 250mmx130mmx30mm foot rest, fixing 100mm dia hci "P" or "S" trap for water closet squatting pan including jointing the trap with pan in cement mortar (1:1), cutting the floor and mending good the damages etc. all complete as per P.H. specification and direction of Engineer-in-charge. 580mmx440mm size Orissa pan( Parryware/Hindware/ Somany/Cera make)-Orissa pan 580mmx440mm size of Hindware 20076 |
537 | Squatting urinal- ( Parryware/Hindware/ Somany/Cera make) |
538 | Supplying all materials, labour, T&P and fixing Wash Down Water Closet (European type W.C pan) with integral ‘S’ or ‘P’ trap to the floor with wooden plug and chromium plated screws including jointing the trap with soil pipe in cement mortar (1:1) etc all complete as per specification and direction of the Engineer in charge.(Hinware/Parryware or equivalent make) EWC .EWC- Hindware 92515 |
539 | FOR -HANDICAPPED PORTION-WB-46x36 with one pair mounting brackets,EWC & Cistern complete with fittings & seat cover,one no.,hinged rail 76cm & 4 Nos.of grab rails 60cm.Mat Code:70002(Matrix set) |
540 | Half stall urinal (Hindware)No.60002 |
541 | 32mm dia CP dome wastefor urinal make Jaguar/ Johnson/Hindware |
542 | Urinal Spreader - make-Jaguar-ALD-CHR-1043 equivalent model of Hindware or Johnson |
543 | Auto closing Urinal valve-Make-Jaguar-PRS-CHR-077 |
544 | Supplying all materials, labour, T&P and fixing wash kitchen sink with outlet at end and weir overflow including fitting and fixing a pair of cast iron or MS brackets painted white, fixing 50mm/40mm dia CP brass waste, fixing 50mm/40mm dia PVC waste pipe 910mm long with supply of wooden plugs, screws and cement etc including cutting holes in walls and making good the damages etc all complete as per specification and direction of the Engineer in charge. 600x450x250 mm stainless steel kitchen sink with drain board-glossy-IS:13983 - 1994 (Jayna make) |
545 | Supplying all materials, labour, T&P and fixing under counter top wash basin with hole for pillar taps with cast iron or M S brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered ‘Hot’ and ‘Cold’ with long screws, shanks and back nuts of 15mm dia nominal bore, fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste,etc all complete as per specification and direction of the Engineer in charge. WB Counter Top OPTRA (57x44) (Parryware/Hindware Cat No-91008 or equivalent |
546 | wash hand basin- wall Hung Basin with Half Pedestal - make-Jaguar -FNS-WHT-40801-and Half Pedestal Hindware 11049 and 91115 |
547 | Supplying all materials, labour, T&P and fixing mirror of superior glass mounted minimum 5mm thick on 6mm thick A.C sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification an direction of the Engineer in charge. |
548 | Design Mirror(Parryware make)600mmx450mm |
549 | Supplying all materials, labour, T&P and fixing standard sized glass-shelf with CP brass brackets and guard rails complete fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge. |
550 | 600x125mm plate glass shelf with CP guard rails(Jaquar)CAN-CHR-1171 |
551 | Supplying all materials, labour, T&P and fixing standard sized CP towel rail complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge. 25mmx600mm long CP towel rail(Jaquar)AKP-CHR-35711PL250 |
552 | C.P. Ring towel ring (Jaquar)AKP-CHR-35721PMI |
553 | Supplying all materials, labour, T&P and providing fitting and fixing (Aqua guard) Pure Chill 80 PSS RO+UV of size 750x570x1350mm height with water storage capacity 80 liters along with 2 nos of faucets 1 for cold water and 1 for normal water including a flow of 1.5 ltr per minute etc all completeas per approved drawing,specification and direction of the Engineer in charge.(As per Model :AG Green pure Chill 80SS of Aquaguard/IONEXCCHANGE) |
554 | Supplying all materials, labour, T&P and providing fitting and fixing (Aqua guard) Pure Chill 120 PSS RO+UV of size 750x570x1350mm height with water storage capacity 120 liters along with 3 nos of faucets 2 for cold water and 1 for normal water including a flow of 1.5 ltr per minute etc all completeas per approved drawing,specification and direction of the Engineer in charge.(As per Model :AG Green pure Chill 120SS of Aquaguard/IONEXCCHANGE)(in Canteen) |
555 | Supplying all materials, labour, T&P and providing fitting and fixing Dr.Aqua guardMagna UV+HD of size 316x251x462mm with wall hanging facility having storage of 7 ltrs. etc.with internal water supply connection complete as per direction of the Engineer-in-charge.( common room) |
556 | Supplying all materials, labour, T&P and fixing CP soap holder complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge. CP soap holder (Jaquar)AKP-CHR-35731P |
557 | Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge. |
558 | First Floor |
559 | Second Floor |
560 | Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12mm size hard broken granite chips including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge In Ground Floor |
561 | First Floor |
562 | Second Floor |
563 | Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge. In Ground Floor |
564 | First Floor- |
565 | Second Floor- |
566 | Supplying the waterproofing material Pidifin 2K of Dr.fixit on equivalent water proofing material and appling in two coat over the concrete floor and dado upto 1"-6" in wall including cleaning,applying and mending as per specification including all labour charges as per direction of Engineer-in-charge. |
567 | First Floor |
568 | Second Floor |
569 | Supplying all materials, labour, T&P and providing ceramic tiles in floors, treads and landing on 25mm thick bed of cement mortar 1:1 (1 cement:1 sand) joined with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing complete as per direction of the Engineer in charge. size 60 x 60 cm Kajaria /equvalent to be pree approved . In Ground Floor |
570 | First Floor |
571 | Second Floor |
572 | Supplying all materials, labour, T&P and fixing porcelain glazed tiles in dados skirting on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shades of the tiles including rubbing and polishing complete as per direction of the Engineer in chargeKajaria / Somany of size 60 cm x 30 cm In Ground Floor |
573 | First Floor |
574 | Second Floor |
575 | Finishing wall surface of walls with Acrylic wall putty (Water based ) of approved make and finished smooth and even surface to receive painting including cost of scaffolding staging charges with cost of all materials taxes, labour T&P etc complete.G.floor |
576 | First Floor |
577 | Second Floor |
578 | Supplying all materials, labour, T&P and providing brick work with K.B bricks having crushing strength not less than 75kg/cm² with dimensional tolerance ± 8 percent in cement mortar (1:4) including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge.In Super structure.G floor |
579 | G.Floor(SS) |
580 | 1st Floor |
581 | 2nd Floor |
582 | Supplying all materials, labour, T&P and providing cement concrete (1:1½:3)with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge. |
583 | 1st Floor |
584 | 2nd Floor |
585 | Supplying all materials, labour, T&P and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge. |
586 | In Ground Floor |
587 | In 1st Floor |
588 | In 2nd Floor |
589 | Supplying all materials, labour, T&P and providing Granite slab urinal partition wall including cutting grooves in wall and making good the damagesand for treading counter wash hand basin slab including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge ,(20mm thick) |
590 | Supplying and fitting-fixing of Un-plasticised Poly Vinyl Chloride (UPVC) (FENESTA / NCL VEKA LTD) Casement ToiletDoor – 60- Series duly manufactured using UPVC reinforced profiles of 60 mm x 55 mmx2.5 mm for outer frames, 102 mm x 60 mm x 2.25 mm for casement Door Sash Profile and 74 mm x 60 mm x 2.5mm mullion profile capable of mounting single glazing system, structurally reinforced with hot dip galvanised up to 50 microns of minimum thickness of 2.0 mm prefabricated & welded through fusion welding.The Door sash shall be fitted with 12mm thick WPC Board of Greenply make duly fixed with EPDM weathering seal resistantaccessories like Bathroom locking system made of aluminium 1 No., per set of sashes and the system is to be installed at the site using anchor fasteners, silicon rubber sealant, easy glazing/ deglazing at site etc., including cost and conveyance of all materials, accessories, labour charges. The materials and product confirming to ASTM D 638-14, EN-477-95 and other applicable codes and standards |
591 | D=63x0.85x2.13= |
592 | EXTERNALP.H. WORK.Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized PVC pipes conforming to IS: 4985/2000 of the following outside dia for class–3(0.60mpa) including jointing with supply of approved solvent cement by non-heat application method/as per manufacturer’s specification, providing and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the Type C-1 standard bedding surrounding or encasingincluding concrete for bedding and curing etc all complete as per PH specification and direction of the Engineer in charge. |
593 | 110mm dia U-PVC Alround Concrete |
594 | 160mm dia U-PVC Alround Concrete |
595 | Supplying all materials, labour, T&P and constructing gully trap chamber of the following inside size with 8cm thick R.C.C precast cover slab in cement concrete (1:2:4) mix using 12mm size h.g chips, foundation concrete (1:4:8) using 40mm size hard granite metal on bed and around trap, KB brickwork in cement mortar (1:6) in F&P and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mmx100mm size HCI gully trap,150mmx150mm size CI grating etc all complete as per approved drawing, specification and direction of the Engineer in charge. Inside size 250mmx250mm |
596 | Supplying all materials, labour, T&P and constructing inspection chamber of the following sizewith cement concrete(1:3:6) using 40mm size hard granite metal on bed, Ground class fly ashbrickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips, 12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, RCC cover slab in (1:1.5:3) using 12mm size h.g chips with RCPC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge. Inside size 750mmx750mmx450mm |
597 | Supplying all materials, labour, T&P and constructing Man hole chamber of the following sizewith cement concrete(1:3:6) using 40mm size hard granite metal on bed, Ground class fly ashbrickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips, 12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, RCC cover slab in (1:1.5:3) using 12mm size h.g chips with RCPC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge. Inside size 1200mmx900mmx900mm |
598 | Supplying all materials, labour, T&P and constructing soakway pit of the following size with dry brick walling from bottom upto invert of inlet pipe and 1st class K.B brickwork in cement mortar (1:6) for the remaining height at top, cement concrete (1:4:8) using 40mm size hg chips on bed, 12mm thick cement plaster (1:4) inside and outside over masonry brickwork, gravel backing in the rear of well steining, RCC cover slab in cement concrete (1:2:4) using 12mm size hg chips fitted with iron lifting handles including earthwork in open well excavation in all kinds of soil and refilling of cavity around the pit & painting the iron works, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge |
599 | 1.80m diax2.60m deep |
600 | 1 no 150000 ltr capacityUnder ground sump (12mx6.5x2.3m) |
601 | Earth work in excavation of foundation in all kinds of soil with in 1.5m initial lift including dressing and leveling of bed and breaking the clods and the excavated materials with in 50m initial lead as per direction of Engineer in charge. |
602 | ……… do ………. with 1st extra lift of 1.50m |
603 | Supplying all materials, labour, T&P and providing shoring and shuttering foundation trenches, pits etc with close wooden planks or sheets shuttering etc all complete as per direction of the Engineer in charge. |
604 | Supplying all materials, labour, T&P and filling in foundaton and plinth with sand well watered and rammed including conveyeance of all materials to worksite,payment of royalty, taxes etc all complete as per direction of the Engineer in charge. |
605 | Supplying all materials, labour, T&P and providing cement concrete ( 1:3:6 ) with 40mm size crusher broken hard black granite metal including watering, curing,cost of all materials, conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge. |
606 | Supplying all materials, labour,T&P and providing cement concrete (1:1.5:3) for RCC work using 12mm HG chips including hoisting,laying,curring and conveyance of all materials to site etc complete. |
607 | Supplying all materials, labour, T&P and providing steel reinforcement of Fe-415 /Fe-500 grade for RCC work including cutting,bending,bindingand tying the grills and placing in position including cost of binding wire 18 to 20 gauge,cost of steel, conveyance of all materials to worksite, payment of royalty,all taxes etc all complete as per PWD specification and direction of the Engineer-in-charge@ 120% rcc work |
608 | Supplying all materials, labour, T&P and providing rigid & smooth centering and shuttering for RCC works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc. all complete as perspecification and direction of the Engineer-in-charge |
609 | RCC floor roof, chajja etc |
610 | RCC Beam, Column, wall etc |
611 | Supplying all materials, labour,T&P and providing 6mm thick cement plasster (1:4) overCC workincluding watering curring and conveyance of all materialsto site. |
612 | Supplying all materials, labour, T&P and providing cement punning including watering, curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxes etc. all complete as perspecification and direction of the Engineer-in-charge |
613 | Providing fitting and fixing stainless steel ladder including fixing to wall necessary welding etc. complete 2nos |
614 | Providing fitting and fixing RCPCcoveretc complete as per direction of Engineer-in-charge. |
615 | Supplying allmaterials, labour, T&P for removingthe excavated earthby mechanical meansetc . |
616 | De watering |
617 | Supplying all materials, labour, T&P and providing, fitting and fixing submersible pump with squirrel cage induction type submersible type submersible electric motor to run on 3 phase/1 phase line voltage ranging from 320 volt to 450 volt conforming to IS: 8034/89 with following specifications with suitable control panel, jointing with GI/PVC/HDPE pipes, electrification, testing, commissioning, trial running, conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge 2H.P three phase 3 stage head range 30 to 54 metres, discharge 155 to 110 L.M.P with outlet dia of 32mm (for sump) one no for stand by |
618 | DOL Control panel |
619 | 2.50sqmm flat cable |
620 | Labour charges for lowering including transportation |
621 | Sinking of( 200 x150)mm dia bore well - 2 Nos byDTHmethod. 2nos |
622 | Labour for drilling a perfectly vertical bore hole of specified dia for a specified depth below first level through consolidated and unconsolidated rock with down the hole hammer drilling rig or combination rig as required to suit the site condition as per the direction of the Engineer in charge including use of own rig with its accessories, tools and plant and consumables etc for lowering of 200mm/150mm dia G.I/P.V.C/M.S casing pipes for housing fitted with socket and with or without well screen as per the necessity for soft, medium, hard and boulder formation (G.I/ P.V.C/ M.S casing pipes if required to prevent collapse of overburden is to be provided by the contractor including lowering and withdrawing after completion of the tube well), 200mm dia to 400mm dia in overburden portion including packing of gravel supplied by the contractor for 400mm dia bore only |
623 | Drilling of 200mm dia bore |
624 | 00 mtr to 45mtr |
625 | Labour for drilling of 150 mm dia bore |
626 | 45 mtr to 150mtr |
627 | Lowering the following size of G.I/P.V.C/M.S housing pipes with or without slotted pipes as per the necessity from first level up to 45.00m depth and fitted and fixed up in perfectly vertical position including cutting and threading of pipes and slotted pipes and supplying and fixing all jointing materials, tools and plant etc all complete and keeping the top of casing pipe threaded including plugging tube wells to prevent entry of foreign materials. |
628 | Lowering of 200mm dia P.V.C casing pipes |
629 | 00 mtr to 30 mtrs1x30.00mtr each=30.00mtr |
630 | 30 mtr to 60mtr 1x15.00mtr each=15.00mtr |
631 | Supplying polyvinyl chloride pipes as per ASTM-D-1785-89 having threads in accordance with DIN 2999 part-1/DIN-42225 part-II specification length of pipe (laying length) will be 3 mtrs. The pipes shall be supplied with both external and threaded with free socket. The pipe having external thread at one end i.e female and or belled end. The female end having internal thread is to be belled in order to accept the male end while jointing pipes with a bore threading shall be provided with a greave at the roof of the male thread accomodate flexible PVC/Rubber "O" ring to make the joint water tight colour of the pipe shall be blue. The name of the manufacture along with batch No class of pipe shall be stranded legibly of each pipe length. |
632 | 200mm dia PVC (sch-80) pipe 2x46.00mtr each=92.00mtr |
633 | Supplying all materials, labour, T&P and providing and providing sanitary sealing by cement concrete grouting of annular space around GI/PVC/MS housing pipe upto 5m below first level (as per drawing) to plug the bore hole excluding cost of cement all complete as per direction of the Engineer in charge. Minimum one metre of casing pipe to be inserted in the bore into the rock at the bottom to ensure sanitary sealing . |
634 | Cost of Cement |
635 | Cleaning and developing the tube well with supply of compressor worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour as per direction of the Engineer in charge |
636 | By DTH Rig |
637 | Supplying all materials, labour, T&P for lowering of ND cashing pipe inthe borewell includingall necessary equipment and labour as per direction of the Engineer in charge . |
638 | Supplying all materials, labour, T&P forwithdrawing casing pipes from the unsuccessful borewell includingall necessary equipment and labour as per direction of the Engineer in charge . |
639 | Supplying all materials, equipment, labour & conducting reconnaissance survey, integrated Hydrological and Geophysical (Electrical Resistivity Method) survey & selection of potential source for exploration of first Water including selection and recommendation of site for drilling wells in selected locations in any part of Orissa under the following Geological formation: |
640 | qnty. |
641 | Supplying all materials, labour, T&P and providing, fitting and fixing verticalsubmersible pump to run on 3 phaseline voltage ranging from 320 volt to 450 volt conforming to IS: 8034/89 withjointing with GI/PVC/HDPE pipes, electrification, testing, commissioning, trial running, conveyance of all materials to worksite, etc all complete as perdirection of the Engineer in charge (Texmo/ KSB/Kirloskar make) |
642 | 2 H.P.three phase 3 stagehead -60 M, with discharge capasity 145 to 110 L.P.M With outlet dia 25 mm (keeping 100% standby) verticalsubmersible pump |
643 | DOL Control panel |
644 | 40mm dia steel short piece |
645 | Well cap |
646 | 50mm size CI bracket |
647 | 2.50sqmm flat cable |
648 | 20mm dia rigid UPVC pipes |
649 | Torchain rope with cover 5 mm ARK |
650 | Labour charges for lowering including transportation |
651 | Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor HDPE pipes and pipe fittings conforming to IS: 4984/2000 (10kgf/sqcm) of the following nominal bore with clamps and jointing by Fusion welding method including testing, making good the wall, ceilingand floor all complete as per specification and direction of the Engineer in charge |
652 | 32mm HDPE pipes (Finolex/Supreme make) wih 10 kg/cm2 |
653 | RAIN WATER HARVESTING SYSTEM(PIT) 4nos |
654 | Earthwork in excavation upto 1.50mtr depth of foundation trenches for columns, basement, tie beams, walls and steps in following types of soil including moorum, hard stony earth, earth mixed with boulders, DI rocks etc but nut requiring blasting with initial leads and lifts including dressing and leveling the bed sides up to required depth and depositing the excavated materials at places away from the work site with T&P for shoring, shuttering, dewatering if required etc. complete as per the drawing, design including cost of all labour, T&P etc. as required for the work complete as directed by the Engineer-in-charge. |
655 | Earthwork in excavation beyond 1.50mtr depth of foundation trenches for columns, basement, tie beams, walls and steps in following types of soil including moorum, hard stony earth, earth mixed with boulders, DI rock etc but not requiring blasting with initial leads and lifts including dressing and leveling the bed sides up to required depth and depositing the excavated materials at places away from the work site with T&P for shoring, shuttering, dewatering if required etc. complete as per the drawing, designing including cost of all labour, T&P etc. as required for the work complete as directed by the Engineer-in-charge. |
656 | Supplying and filling the Foundation & Plinth with clean coarse river sand of approved quality from approved quarry, laying in layers not exceeding 150mm thick, watering and ramming including cost, conveyance, royalty and taxes of all materials, cost of all labour, T&P etc. as required for the work complete as per direction of the Engineer-in-charge. |
657 | Providing & laying cement concrete of prop. (1:3:6) in foundation bed and floors using 40mm nominal size down graded, screened, washed hard black crusher broken granite metal of approved quality & from approved quarry including laying in the layers not exceeding 100 mm thick, hoisting, lowering, laying, watering and curing etc. complete to the required levels including cost, conveyance, royalty and taxes of all materials, cost of all labour, T&P etc. as required for the work complete and as per direction of Engineer-in-charge. |
658 | RAINY 100 sizeMECHANICALFILTER as IFC -1 |
659 | Rain water collection chamber all complete |
660 | Supplying all materials, labour, T&P, fitting and laying in trenches PVC pipes & fittings of approved make confirming to IS-4985 and specials of the following outside diameter and classes including jointing with supply of approved solvent cement by non heat application method including testing etc complete as per the PH specification and direction of the Engineer-in-charge. (Earthwork to be measured separately)ASTRAL/ASHRIVAD/AJAYA/AKG/SUPREME. |
661 | 110mm dia |
662 | 160mm dia |
663 | Providing and laying in trench cement concrete ( 1:3:6 ) with 40mm size hard granite metal in the following type of bedding for pvc pipes of the following internal diameter including curing complete as per specification |
664 | 110mm dia |
665 | 150mm dia |
666 | Supplying all materials, labour, T&P and fitting and fixing of HDPE solvent joint ball valve of 150mm Dia confirming to the relevant IS specification and dimension including fixing it in position along the pipeline with supply of all required materials such as rubber insertion, nuts & bolts including cost of all materials, taxes, and duties, transportation charges from store to site etc all complete as per the direction of Engineer-in-charge. |
667 | Supplying all materials, labour,T&P and providing cement concrete (1:1.5:3) for RCC work using 12mm HG chips including hoisting,laying,curring and conveyance of all materials to site etc complete. |
668 | Supplying all materials, labour, T&P and providing steel reinforcement of Fe-415 /Fe-500 grade for RCC work including cutting,bending,bindingand tying the grills and placing in position including cost of binding wire 18 to 20 gauge,cost of steel, conveyance of all materials to worksite, payment of royalty,all taxes etc all complete as per PWD specification and direction of the Engineer-in-charge.@120% of RCC work |
669 | Supplying all materials, labour, T&P and providing rigid & smooth centering and shuttering for RCC works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc. all complete as perspecification and direction of the Engineer-in-charge |
670 | RCC floor roof, chajja etc |
671 | RCC Beam, Column, wall etc |
672 | Supplying all materials,labour,T&P and providing 12mm thick cement plaster(1:3) on RCC work including watering,curing,cost of all materials, conveyance of all materials to worksite,paymentof royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge. |
673 | Supplying all materials, labour, T&P and providing cement punning including watering, curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxes etc. all complete as perspecification and direction of the Engineer-in-charge |
674 | Filling in foundation and plinth with excavated materials, moorum including watering and ramming as directed by the Engineer in charge |
675 | Supplying all labour, T&P for the media (50-40=500mm (Rs 8/ kg),12- 20 = 300 mm (Rs 8/ kg),charcoal / antharasite = 300mm(Rs 22/kg) Filter Sand =400mm (Rs 8/kg) ), labour charges for loading and unloading as required for the work etc. complete as per the direction of the Engineer-in-charge. |
676 | Filling foundation trenches and plinth with excavated earth including laying the earth in layers not exceeding 23.5cm (9”) thick ramming and watering with all leads and lifts including cost of all labour, T&P etc. complete as directed by the Engineer-in-charge. |
677 | Supplying all labour, T&P for the Carriage of excavated earth by mechanical means of transport within 5.00 K.M. lead including hire and running charges of vehicles, labour charges for loading and unloading as required for the work etc. complete as per the direction of the Engineer-in-charge. |
678 | Sinking of tube well(200) for PIT-4nos |
679 | Labour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level through consolidated and unconsolidated rock with down the hole hammer drilling rig or combination rig as required to suit the site condition as per the direction of the Engineer in charge including use of own rig with its accessories, tools and plant and consumables etc for lowering of 200mm/150mm dia G.I/P.V.C/M.S casing pipes for housing fitted with socket and with or without well screen as per the necessity for soft, medium, hard and boulder formation (G.I/ P.V.C/ M.S casing pipes if required to prevent collapse of overburden is to be provided by the contractor including lowering and withdrawing after completion of the tube well), 200mm dia to 400mm dia in overburden portion including packing of gravel supplied by the contractor for 400mm dia bore only |
680 | Drilling of 200mm dia bore |
681 | 00 mtr to 30mtr |
682 | Lowering the following size of G.I/P.V.C/M.S housing pipes with or without slotted pipes as per the necessity from ground level up to 45.00m depth and fitted and fixed up in perfectly vertical position including cutting and threading of pipes and slotted pipes and supplying and fixing all jointing materials, tools and plant etc all complete and keeping the top of casing pipe threaded including plugging tube wells to prevent entry of foreign materials. |
683 | 200mm dia PVCpipe |
684 | cost of 200mm pvc pipe |
685 | Cutting slot in casing pipe for recharge of rain water |
686 | labour for packing gravel outside the tube well |
687 | Cost of washed gravel |
688 | Construction of 30000 Liters RCC Over head Tank of Inside size- 5.50X 4.80X1.50 |
689 | Supplying all materials, labour,T&P and providing cement concrete (1:1.5:3) for RCC work using 12mm HG chips including hoisting,laying,curring and conveyance of all materials to site etc complete.in 4th floor |
690 | Supplying all materials, labour, T&P and providing M.S.Reinforcement for RCC work including cutting, banding, binding, straightening and trying the grills and placing in position including cost of binding wire 18 to 20 gage.in 4th floor |
691 | Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for RCC work including false work and dismantling then after casting including cost of materials complete in 4th floor |
692 | RCC floor roof, chajja etc |
693 | RCC Beam, Column, wall etc |
694 | Supplying all materials, labour,T&P and providing 6mm thick cement plasster (1:4) overCC workincluding watering curring and conveyance of all materialsto site.in 4th floor |
695 | Supplying all materials, labour, T&P and providing cement punning including watering, curring and conveyance of all materials to site.in 4th floor |
696 | Supplying and fitting and fixing stainless steel 304 grade in said rail using 50mm dia 2mm thick circular pipe and Balustrade 32mmx32mmx2mm at the rate of mtr.Center to center and square pipe 32x32x2mm below including welding with stanless steel elect rod and fixing with necessary accessories etc.complete as per direction of the Engineer-in-charge. |
697 | Providing fitting and fixing MS cover made out of MS angle and sheet duly welding and fixing with frame and hinges along with locking arrangement of size 60cmx60cm etc complete as per direction of Engineer-in-charge |
698 | `100 UserRCC Septic tank- 2 Nos Earthwork in excavation of foundation in all kinds of soil within 50m initial lead and 1.5m initial lift including rough dressing and breaking clods to minimum 5cm to 7cm and laying in layers not exceeding 0.30m in depth and as per direction of the Engineer in charge. Initial lift |
699 | ……… do ………. with 1st extra lift of 1.50m |
700 | Supplying all materials, labour, T&P and providing shoring and shuttering foundation trenches, pits etc with close wooden planks or sheets shuttering etc all complete as per direction of the Engineer in charge. |
701 | Supplying all materials, labour, T&P and filling in foundaton and plinth with sand well watered and rammed including conveyeance of all materials to worksite,payment of royalty, taxes etc all complete as per direction of the Engineer in charge. |
702 | Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge In ground floor |
703 | Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12mm size crusher broken hard black granite chips including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge.(a) Groundfloor |
704 | Supplying all materials, labour, T&P and providing cement concrete (1:1.5:3) with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge. In ground floor |
705 | Supplying all materials, labour, T&P and providing M.Sreinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge In ground floor |
706 | Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for RCC work including false work and dismantling then after casting including cost of materials complete in ground floor. |
707 | R.C.C beams, columns, girder and bressmer etc--In G.F |
708 | R.C.C floor and roof slabs, landings, balconies, projecting sunshades and chajjas up to4.30m height |
709 | R.C.C Plinth bend / Raft |
710 | Supplying all materials, labour, T&P and providing 6mm thick cement plaster (1:4) on RCC work including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge In ground floor (inside) |
711 | Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4)with cement punningincluding watering,curring and conveyance of all materials to site. |
712 | Supplying all materials, labour, T&P and providing cement punning including watering, curring and conveyance of all materials to site. |
713 | Supplying all materials, labour, T&P and futting and fixing 20mm dia MS/CI step iron including supply of necessary C.C(1:2:4) for fixing etc complete as per P.H.D. specification. |
714 | Supplying all materials, labour, T&P and fitting and fixing S.W.Tee of size 150mx150mx150m as per P.H.D.specification and direction of the E.I.C. |
715 | Supplying all materials, labour, T&P and constructing vent base as per P.H.D specification etc all complete. |
716 | Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer"s specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the engineer in charge. 160mm diameter U-PVC SWR pipes(Supreme/Ashirvad) |
717 | 160mm U-PVC cowl |
718 | Supplying allmaterials, labour, T&P for removingthe excavated earthby mechanical meansetc . |
719 | Supplying all materials, labour, T&P and constructingBore well protectionchamber of the inside size 650x650x1000hightwith cement concrete (1:3:6) using 40mm size hard granite metal on foundation, 1st class Fly ashbrickwork in cement mortar (1:3), with base cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:4)inside and outside, R.C.C cover slab in (1:1.5:3) using 12mm size h.g chips, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge. |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy