}

Tender For Repair/Maintenance Of External Lt Supply, Lt Panel Board, Lt Switch Gear, Overhead Line And Allied Works At Various Sub Stn Of Ch Cc, Cmdc, College Of Nursing In The Area Of Age E/M (Hosp) Under Ge E/M Lucknow, lucknow-Uttar Pradesh

Military Engineer Services-MES has published Tender For Repair/Maintenance Of External Lt Supply, Lt Panel Board, Lt Switch Gear, Overhead Line And Allied Works At Various Sub Stn Of Ch Cc, Cmdc, College Of Nursing In The Area Of Age E/M (Hosp) Under Ge E/M Lucknow. Submission Date for this Tender is 02-05-2024. Switch Gear Tenders in lucknow Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

43119237
Corrigendum : Tender For Repair/Maintenance Of External Lt Supply, Lt Panel Board, Lt Switch Gear, Overhead Line And Allied Works At Various Sub Stn Of Ch Cc, Cmdc, College Of Nursing In The Area Of Age E/M (Hosp) Under Ge E/M Lucknow
Open Tender
Indian
Uttar Pradesh
lucknow
02-05-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Tender For Repair/Maintenance Of External Lt Supply, Lt Panel Board, Lt Switch Gear, Overhead Line And Allied Works At Various Sub Stn Of Ch Cc, Cmdc, College Of Nursing In The Area Of Age E/M (Hosp) Under Ge E/M Lucknow

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 25-Apr-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 02-05-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 98000.0 /-
Tender Value
INR 49 Lakhs /-

Attachment

FileName File Description File Size
5ea9ce18-99c1-4444-a815-3f6511ad7294.html Tender Notice 0 KB
BOQ_727108.xls Tender Document 0 KB
Tender23.pdf Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

NAME OF WORK: REPAIR/MAINT OF EXTERNAL LT SUPPLY, LT PANEL BOARD, LT SWITCH GEAR, OVERHEAD LINE AND ALLIED WORKS AT VARIOUS SUB STN OF CH CC, CMDC, COLLEGE OF NURSING IN THE AREA OF AGE E/M (HOSP) UNDER GE E/M LUCKNOW
Sl. No. Item Description
1Material & Laying, jointing and testing in replacement ofLT under ground electric power cablecrossed linked polyethylene ( XLPE)insulated, galvanised steel strip or wire armoured,ISI-7098 Marked, with aluminium conductor multi stranded , heavy duty 1100 Volts grade of size 10 sqmm cross sectional area, 2 core ,complete all as specified laid in trenches/ laid under floor or fixed naked with walls / on poles/ in ducts /in GI pipes etc. with and including MS Clamps, nuts , bolts, washers complete all as specified and directed. Note :-Excavation, earth work, sand cushioning, protection bricks/ tiles/ block andpipe shall be measured and paid separately under appropriate items.
2All as per item No 1 above butLT UG Cable of size 10 Sqmm 4 core
3All as per item No 1 above butLT UG Cable of size 16 Sqmm 4 core
4All as per item No 1 above butLT UG Cable of size 25 Sqmm 3.5 core
5All as per item No 1 above butLT UG Cable of size 50 Sqmm 3.5 core
6All as per item No 1 above butLT UG Cable of size 95 Sqmm 3.5 core
7All as per item No 1 above butLT UG Cable of size 150 Sqmm 3.5 core
8All as per item No 1 above butLT UG Cable of size 185 Sqmm 3.5 core
9All as per item No 1 above butLT UG Cable of size 240 Sqmm 3.5 core
10Supply and laying in trenches / Floor / road crossing or fixed to Pole / Wall GI pipe light grade ISI marked with fitting of size 40 mm bore for protection of cable including taking down existing pipe complete all as specified and directed by the Engineer-in-Charge.
11Supply and laying in trenches / Floor / road crossing or fixed to Pole / Wall GI pipe light grade ISI marked with fitting of size 50 mm bore for protection of cable including taking down existing pipe complete all as specified and directed by the Engineer-in-Charge.
12Supply and laying in trenches / Floor / road crossing or fixed to Pole / Wall GI pipe light grade ISI marked with fitting of size 80 mm bore for protection of cable including taking down existing pipe complete all as specified and directed by the Engineer-in-Charge.
13M&L plain cement concrete 1:2:4 type B1 using 20 mm graded stone aggregateas in copings for electric pole and other similar work, weathering, slightly rounded or chamfered angles etc including use & waste form work and demolition of old coping all as specified and directed
14Supply & Fix in replacement canopy headed junction box suitable for LT Pole made out 3.15 mm MS sheet of size 30 x 25 x 15 cm with cover, 04 Nos aluminium bus bar of size 25 x 3 mm for phase and neutral 01 nos 06 Amps MCB SP mounting channel for control street light cable gland aluminium lug MS FIixing clamp -02 nos with nut bolt washer painting with two coat of synthectic enamel paint over a coat of red oxide primer on external and internal surface complete all as specified and directed
15Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying of cables, pipes etc. and getting outincluding trimming the sides and forming bottom surfaces to required levels in soft / loose soilcomplete all as specified and directed.
16Returning, filling in, including spreading, levelling, and well ramming in layer not exceeding 25 cm thick using excavated soft / loose soil complete all as specified and directed.
17Removing excavated material (soils) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified.
18Material and labour for river sand, washed and screened dry for cushioning to under ground cable in trenches below and around under ground cable including spreading and levelling complete as specified and directed . Note :- Punned thickness shall only be considered for payment
19M&L for laying of well burnt old sizebricks, sub class "B" bricks, straight or curved on plan, laid flat with width equal to length of brick , laid dry over electric cable for protection all as specified.
20Supply and fix in repair 18 LED bollard light fitting 60 cm long, having epoxy powder coated pressure die cast aluminium housing Light optic, high impact polycarbonate diffuser, colour temprature 5700K, CRi>70, THD<10% PF >.90surge protection 4 KV inbuilt, rated voltage and frequency 240 Volt, 50 Hz,aesthetic innovative design with uniformly lit diffuser at the upper portion acts a beacon of path guidance in a landsscape IP 65 environmental with PCC 1:3:6 as in foundation work nut, bolt and washer etc complete all as specified and directed by Engr in Charge.
21S&F in repair 20 watt LED Post top light fitting, energy saving, 240V, 50Hz AC, environmental friendly, aesthetically designed electronic constant current, IK07, having epoxy powder coated pressure die cast aluminium housing top cover spun aluminium sheet powder coated, front cover clear acrylic diffuser with indirect symmetrical light distributio, IP-65 luminaire with high power LED as light source, 5700K, PF >0.9, THD<10% and light efficiency 85> , CRI > 70, Surge protection 5KV, fixed over existing post, all as specified and directed.
22Supply and fix in replacement Integral dome type post top iantern, with white coloure plastic body dome of size 300 mm suitable for fixing on 80 mm pipe including 1 x 25 WLED lamp, including making connections complete all as per specified and directed by the Engr-in-Charge.
23Supply, installing, testing and commissioning in replacementfactory made, CPRI approved LT Panel board (Dimention of Cubical / enclosure not less than 1500 mm x 1000 mm x 500mm), confirming to IS 5039, cubical compartmentalized, out door type double door, plate form mounted, suitable for 415 volts, 3 phase, 4 wire, 50 HzAC supply system having bus bar chamber with insulated aluminium bus bars four pole installed on porcelain / SMC insulator. The panel shall be dust and vermin proofIP-54 class protection and outer shell made of of 3.15 mm CRCA MS sheet, inner shell made of 2.0 mm thick CRCA MS sheet , 50x50x6mm thick MS angle iron frame work, the cubical have bottom channel of size 75x40mm, panel shall be over all powder coated with zink metal coating, front and rear opening type, with apron for cable entry closing locking arrangement including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked,1100 volts grade of appropriate size ( but not less than 2.5 Sqmm)and comprising of the following:-
24(1) incoming (i) MCCB4P 250Amps , 25 Ka -01 Nos. (2) Outgiong (i) MCCBs4P Thermal magnatic & fixed type 100 Amps, 25 KA-02 Nos (ii)MCCBs4P Thermal magnitic & fixed type 63 Amps, 25 KA-2 Nos (3)Accessories (i) Aluminium bus bar rating400 Amps - 04 Nos . (ii) digital Volt meter 0-500V with selector switch-01 No (c )digital Amp meter 0-300 amp with CT and selector switch-01 No (d) Indicating lamp-01 Set (LED Type) set of three
25Note - Plateform of panel fixed with PCC 1:4:8 type D-2 with 40mm graded crused stone ,15 cm thick in foundation,brick work in CM 1:6 with sub class B old size bricks ,rendring 15 mm thick in CM 1:6 on exposed surface and 100 mm thick PCC padding 1:3:6,type C-1 using 20mm graded crushed stone aggregate on Top and grouting bolts etc for panel.The plate form shall be such that it is of a height 45 cm above the nearest road level. All out going feeder shall be connected by cable through suitable size gland plate/glands. All MCCB with adjustable protection for over load and shortcircuit protection and confirming to IEC60947-II/IS 13947 -II (Latest Version). The MCCBs shall have spreader links and barriers as standard feature of manufacture.
26Supply, installing, testing and commissioning in replacementfactory made, CPRI approved BUS BAR panel of size1000x 1000 x 500 mm, outdoor typefactory madepedastal type fabricated outof 3.15 mm thick CRCA sheetwith slopy roof, over all powder coated, locking arrangementwith duplicate keys, two earthing terminal, suitable cablegland for all incoming and outgoing cablegrouting of feeder pillerbox 45cm above ground level by providing 90 cm longangle iron of size 50 x 50 x 6 mm welded on all the four corner, embeded in PCC 1:2:4using20 mm stone agregrateup to 50 cm deepincluding connection all exisiting cable withwith MCCB terminal all as specified and directed by EIC at the site requirment complete includingthe following component:- (1) incoming (i) MCCB4P 125Amps , 16Ka-01 Nos. (2)Accessories (i) Aluminium bus bar rating200 Amps -04 Nos. (ii) digital Volt meter 0-500V with selector switch-01 No (iii) digital Amp meter 0-300 amp with CT and selector switch-01 No (iv) Indicating lamp-01 Set (LED Type)
27Material & Labour for preparation of old painted surface of steel tubular pole 9meter long above coping) and applying two coat of aluminium paint, making of strip of 20 cm width (BLACKand white in alternate band) upto 1400 mm height with one synthetic enamel paint , rewriting pole No by painter with enamel paint, and painting the existing MS clamp with one coat of aluminum paint complete all as specifeid and directed.
28Material and labour for writting of Pole Nos on existing pole with stencil out with white colour in BLACK background of 80 mm hight around the radius of pole and all as specified and directed by Engr in charge.
29M&L for preparation of old painted surface of LT panel by scrapping, making good distrubed surfaces by applying putties on uneven surface to make it even and M&L for spray painting to LT panel of any size with two coat of synthetic enamel paint with desired colour complete all as specified and directed.
30S&F MCCBs 100 Amps, four pole 16 KA, fixed typeincluding taking out unserviceable MCCB"s and connecting complete.
31S&F MCCBs 125 Amps, four pole 16 KA, fixed typeincluding taking out unserviceable MCCB"s and connecting complete.
32S&F MCCBs 160 Amps, four pole 16 KA, fixed typeincluding taking out unserviceable MCCB"s and connecting complete.
33S&F MCCBs 200 Amps, four pole 36 KA, fixed typeincluding taking out unserviceable MCCB"s and connecting complete.
34S&F MCCBs 250 Amps, four pole 36 KA, fixed typeincluding taking out unserviceable MCCB"s and connecting complete.
35S&F MCCBs 400 Amps, four pole 36 KA, fixed typeincluding taking out unserviceable MCCB"s and connecting complete.
36S&F MCCBs 630 Amps, four pole 36 KA, fixed typeincluding taking out unserviceable MCCB"s and connecting complete.
37S&F Power contactor 4 pole Type Mcx 32 , Fr size 2 ratingAC 1 rating 160 A, 50 HZ including dismantling the unserviceable contactor, complete all as specified and directed.
38S&F Power contactor 4 pole Type Mcx 23 , Fr size 1 ratingAC 1 rating 40 A, 50 HZ including dismantling the unserviceable contactor, complete all as specified and directed.
39S&F in replacement On load change over switch, 63 Amps, 415 volts, 4 pole side handle type in sheet metal enclosure conforming to IS:13947 (Part-3); IEC:60947-3 with locking facility including all connecting / jointing materials and dismantling of existing change over switch, complete all specified & directed.
40S&F in replacement Offload change over switch, 200 Amps, 415 volts, 4 pole in sheet metal enclosure conforming to IS:13947 (Part-3); IEC:60947-3 with locking facility including all connecting / jointing materials and dismantling of existing change over switch, complete all specified & directed
41S&F in replacementOff load change over switch (side operated handle) 400 Amps, 415 volts 4 pole in sheet metal enclosurewith interlock door and pad lock facility including dismantling of existing change over switch, complete all specified & directed.
42S&F in replacement street light panel fabricated with 3.15 mm thick CRCA sheet, outdoor type, single phase 6 kw load with Astronomicaldigital timerandMCCB of capacity32 Amps TP andMCB SPN 40 Ampsfixed on wall / pole with clamps, nutbolts all as specified and directed
43Deployment of manpower / tools / machinery etc for restringing of existingloose over head line having 4 Nos ACSR conductor and 01 Nos GI wire any size / type etc of existing LT pole including replacement of aluminium binding wire or suitable size carefully without damaging of insulator etc. complete all as specified and as directed by Engineer-in-Charge. Note:- 4 Run of ACSR conductor with 01 Run of GI wire shall be measured as 01 RM for payment. (ii) Linear length centre to centre of the poles shall only bemeasured. (iii) Cleaning / pruning of tree branches falling around the conductor shall also deemed to be included in the quoted rates
44Supplying and fixing in repair flat twin core ,1.5sqmm nominal cross sectional areamultistrandedaluminium conductor cable, over all PVC sheathed, 1100 Volts grade heavy dutycable PVC insulatedand PVC sheathedcomplete all as specified.
45Supplying and fixing in repair flat twin core ,2.5 sqmm nominal cross sectional areamultistrandedaluminium conductor cable, over all PVC sheathed, 1100 Volts grade heavy dutycable PVC insulatedand PVC sheathedcomplete all as specified.
46Supplying and fixing in repair flat twin core, 6 sqmm nominal cross sectional area multistrandedaluminium conductor cable, PVC insulated and sheathed 1100 Volts grade complete all as specified.
47S&F Cable jointing kit for straight through joint, heat shrink type joint for 1100 V grade cable complete with jointing material and accessories suitable for 3.5 / 4 core, 25 to 50 Sqmm XLPE armoured aluminium conductor cable. Note:- Excavation and earth work, extra cable if required will be measured & paid seperatly under respective items of this BOQ.
48All as per Item No 45 abov but straight through joint for cable of size 3.5 core 70 to 150 Sqmm
49All as per Item No 45 abov but straight through joint for cable of size 3.5 core 185 to 300 Sqmm
50Supply and installed in replacement steel tubular swaged pole type 410 SP - 31 (9 mtr long) complete with MS base plate of size 300 x 300 x 6mm thick at bottom, welded at the centre with through hole of 14 mm dia at a height of 300 mm above the coping finial cap and painted with two coats of aluminium paint over a coat of red oxide primer, making of strip of 300 mm width (balck and yellow in alternate band) upto 1500 mm height with one synthetic enamel paint, writing pole No with stencil with white colour in black background with synthetic enamel paint including excavation upto required depth and PCC type C-2 1:3:6 (using 40mm graded) at bottom and PCC type B-1 1:2:4 (20mm graded) for mass filling and pole coping (60x60x30cm) and rendering of coping with 5 mm thick in 1:3 cement mortar complete all as specified and directed.
51M&L Earthing complete with galvanised mild steel earth plate electrode 600x600x6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI strip 32 x 6 mm as earth strip electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth strip encased inand including 40 mm dia GI "lightgrade" pipe from upper end of earth plate upto equipments,20 dia bore GI pipe "light grade" as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe andPCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS TMT bars 8mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as describedin electric plate of SSR Part I completeall as specified and directed and testing on completion. Note :- Ifthe desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
52Deployment of manpower / tools / machinery etc for testing the cables with high voltage DC testing machine and locating the fault in the cables by fault locating machine to pin point exact position of fault, disconnecting faulty 1100 Volt LT cables of differentsizesfrom both ends, removal of Fault,Re-connections and testing of cables after removal of fault complete all as specified and directed.
53Note: (a)1100 Volt LT cable & joints shall be measured and paid for seperately under respective items of schedule. (b) Retrieved old serviceable cable cover/brickswill be laid in trenches for cable protection. If extra PCC cover/bricks and sand required at site shall be measured and paid separately under respective items of BOQs. (c) Excavation and earth work will be measured and paid for seperately under respective items of schedule. (d) Note:-Contractor or his rep shall come to the site of breakdown within one hour of notification of breakdown .In case the rep or contractor shall not come to the site of breakdown and start attending breakdown within 1.00 hour a penalty of Rs 1000 per fault per hour will be imposed over contractor and will be deduct from his dues.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail