Tender For Repair / Maintenance Of External Lt Supply, Lt Panel Board, Lt Switchgear, Overhead Line And Allied Works At Various Sub Stn Of Base Hosp, Sho, Echs, Soi, Pda And Manoj Pandey Swimming Pool In The Area Of Age E / M ( Hosp ) Under Ge E , lucknow-Uttar Pradesh

Military Engineer Services-MES has published Tender For Repair / Maintenance Of External Lt Supply, Lt Panel Board, Lt Switchgear, Overhead Line And Allied Works At Various Sub Stn Of Base Hosp, Sho, Echs, Soi, Pda And Manoj Pandey Swimming Pool In The Area Of Age E / M ( Hosp ) Under Ge E . Submission Date for this Tender is 02-05-2024. Switch Gear Tenders in lucknow Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

43118324
Corrigendum : Tender For Repair / Maintenance Of External Lt Supply, Lt Panel Board, Lt Switchgear, Overhead Line And Allied Works At Various Sub Stn Of Base Hosp, Sho, Echs, Soi, Pda And Manoj Pandey Swimming Pool In The Area Of Age E / M ( Hosp ) Under Ge E
Open Tender
Indian
Uttar Pradesh
lucknow
02-05-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Repair / Maintenance Of External Lt Supply, Lt Panel Board, Lt Switchgear, Overhead Line And Allied Works At Various Sub Stn Of Base Hosp, Sho, Echs, Soi, Pda And Manoj Pandey Swimming Pool In The Area Of Age E / M ( Hosp ) Under Ge E / M Lucknow

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 25-Apr-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 02-05-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 90000.0 /-
Tender Value
INR 45 Lakhs /-

Attachment

FileName File Description File Size
e4cf22ed-9843-40bb-95c7-6f64c7e75582.html Tender Notice 0 KB
BOQ_727090.xls Tender Document 0 KB
Tender22.pdf Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

NAME OF WORKS: REPAIR/MAINT OF EXTERNAL LT SUPPLY, LT PANEL BOARD, LT SWITCHGEAR, OVERHEAD LINE AND ALLIED WORKS AT VARIOUS SUB STN OF BASE HOSP, SHO, ECHS, SOI, PDA AND MANOJ PANDEY SWIMMING POOL IN THE AREA OF AGE E/M (HOSP) UNDER GE E/M LUCKNOW.
Sl. No. Item Description
1Supply, laying or fixing in replacement, jointing and testing LT under ground electric power cable crossed linked polyethylene (XLPE) insulated, galvanised steel strip or wire armoured,ISI-7098 marked, with aluminium conductor multi stranded, heavy duty 1100 Volts grade of size 10 Sqmm cross sectional area, 2 core, complete all as specified laid in trenches / laid under floor or fixed naked on walls / on poles / in ducts / in GI pipes etc. with and including MS Clamps, nuts, bolts, washers complete all as specified and directed. Note :-Excavation, earth work, sand cushioning, protection bricks / tiles / block and pipe shall be measured and paid separately under appropriate items.
2All as per Item No 01 but cable of size 10 Sqmm 4 core.
3All as per Item No 01 but cable of size 16 Sqmm 4 core.
4All as per Item No 01 but cable of size 25 Sqmm 3.5 core.
5All as per Item No 01 but cable of size 35 Sqmm 3.5 core.
6All as per Item No 01 but cable of size 50 Sqmm 3.5 core.
7All as per Item No 01 but cable of size 70 Sqmm 3.5 core.
8All as per Item No 01 but cable of size 95 Sqmm 3.5 core.
9All as per Item No 01 but cable of size 120 Sqmm 3.5 core.
10All as per Item No 01 but cable of size 240 Sqmm 3.5 core.
11Excavation in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying of cables, pipes etc. and getting out in soft loose soil, including trimming the sides and forming bottom surfaces to required levels complete all as specified and directed.
12Returning, filling in, including spreading, levelling, and well ramming in layer not exceeding 25 cm thick using soft / loose soil complete all as specified and directed.
13Removing excavated soils not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified.
14Material and labour for dry river sand, washed and screened dry for cushioning to under ground cable in trenches below and around under ground cable including spreading and levelling complete as specified and directed . Note :- Punned thickness shall only be considered for payment
15M&L for laying well burnt old size bricks, sub class "B" bricks, straight or curved on plan, laid flat with width equal to length of brick, laid dry over electric cable for protection all as specified.
16Deployment of tools & manpower for Boring of hole under road / pavement / hard standing or any other situation by manual means suitable for passing of 40 to 80 mm bore pipe and making good both ends all specified and directed
17M&L for 40 mm bore mild steel galvanised water tubing, light grade with all fittings and fixed to walls or laid onfloors / fixed to poles / or passing under road crossing, for protection of UG cable including taking down old GI pipe complete all as specified and directed by Engr-in-Charge.
18M&L for 50 mm bore mild steel galvanised water tubing, light grade with all fittings and fixed to walls or laid onfloors / fixed to poles / or passing under road crossing, for protection of UG cable including taking down old GI pipe complete all as specified and directed by Engr-in-Charge.
19M&L for 80 mm bore mild steel galvanised water tubing, light grade with all fittings and fixed to walls or laid onfloors / fixed to poles / or passing under road crossing, for protection of UG cable including taking down old GI pipe complete all as specified and directed by Engr-in-Charge.
20Disconnecting faulty 1.1 KVLT cables of any size and any lengthfrom both ends Hiring of cable fault detector machine to detect exact position of fault , removal of Fault,Re-connections and testing of cables after removal of fault etccomplete as specified and directed. Note :(a) 1.1KVLT cable & joints shall be measured and paid for seperately under respective items of schedule. (b)Contractor or his rep shall come to the site of breakdown within one hour of notification of breakdownalongwith fault locating machine and manpower.In case the rep or contractor shall not come to the site of breakdown and not to start attending breakdown within 1.00 hour a penalty of Rs 1000 per fault per hour will be imposed over contractor and will be deduct from his dues.
21Taking outfaulty underground1100 Volt LT cable of different sizes after excavation and removing bricks of any size and relaying in the same trenches or re routing after rectification of fault by straight through joint complete all as directed. Note: (a) 1100Volt LTcable & joints will be measured and paid for seperately under respective items of schedule. (b) Retrieved old serviceable brickswill be laid in trenches for cable protection. If extra bricks and sand required at site shall be measured and paid separately under respective items of BOQs. (c) Excavation and earth work will be measured and paid for seperately under respective items of schedule.
22Material & Labour for preparation old painted steel surface of LT tubular pole pole 9 meter long above coping, including MS clamp and applying two coat of aluminium paint, making of strip of 300 mm width (balck and yellow in alternate band) upto 1500 mm height with one synthetic enamel paint, rewriting pole No with stencil with white colour in black background with synthetic enamel paint, complete all as specifeid and directed.
23Supply drawing, connecting and testing in replacement3 core, 1.5 Sqmm PVC insulated and PVC round sheathed`copper conductor (flexible) industurial cable, 1100 Volts conforming to IS 694 in steel tubular poles from Junction box to street light fitting including providing suitable copper lugs all as specified and directed by Engr-in-charge.
24Supply drawing, connecting and testing in replacement3 core, 2.5 Sqmm PVC insulated and PVC round sheathed`copper conductor (flexible) industurial cable, 1100 Volts conforming to IS 694 in steel tubular poles from Junction box to street light fitting including providing suitable copper lugs all as specified and directed by Engr-in-charge.
25Supply & Fixin replacement twin core, 6 Sqmm nominal cross sectional area multistranded aluminium conductor cable, over all PVC sheathed, 1100 Volts grade heavy duty cable PVC insulatedcomplete all as specified.
26M&L for removal of existing paint from external surface of LT panel by scrapping, making good distrubed surfaces by applying putties on uneven surface to make it even and M&L for spray painting to LT panel of any size with two coat of synthetic enamel paint with desired colour over one coat of red oxide primer complete all as specified and directed.
27Supply and fix in replacement CRCA MS sheet for LT panel having thickness 3.15 mm powder coated finish over one coat of red oxide on out side surface and painted in side with two coats of red oxide primer including all fixing acessories i.e. suitable size of hinge, nuts, bolts, washers, cutting and welding works etc complete all as directed by Engr -in-charge
28Supply, fix, connecting and testing in replacement MCCB 100 Amp 4 pole 25 KA 415 volts 50 Hz with spreader after taking down old existing unserviceableMCCB complete all as directed
29Supply, fix, connecting and testing in replacement MCCB 125 Amp 4 pole 25 KA 415 volts 50 Hz with spreader after taking down old existing unserviceableMCCB complete all as directed
30Supply, fix, connecting and testing in replacement MCCB 160 Amp 4 pole 25 KA 415 volts 50 Hz with spreader after taking down old existing unserviceableMCCB complete all as directed
31Supply, fix, connecting and testing in replacement MCCB 250 Amp 4 pole 36 KA 415 volts 50 Hz with spreader after taking down old existing unserviceableMCCB complete all as directed
32Supply, fix, connecting and testing in replacement MCCB 400 Amp 4 pole 36 KA 415 volts 50 Hz with spreader after taking down old existing unserviceableMCCB complete all as directed
33Supply, fix, connecting and testing in replacement MCCB 630 Amp 4 pole 36 KA 415 volts 50 Hz with spreader after taking down old existing unserviceableMCCB complete all as directed
34Supply, fix, connecting and testing in replacement Digital type Volt meter (0-500 V ), 3 ph, class 1 including taking down unserviceable voltmeter, complete all as specified and directed.
35Supply, fix, connecting and testing in replacement Digital type Ammeter (0-300 A), 3 ph, class 1including taking down unserviceable ammeter, complete all as specified and directed.
36S&F Indicator lamps (LED Type) including taking down unserviceableindicator lamps complete all as specified and directed.
37S&F in repair MCB’s single pole with neutral, 6 to 32 Amps, 250 volts with"C" curve, fixed in existing PVC box including connecting complete.
38M&L plain cement concrete cast in situ 1:3:6 type C1 using 20 mm graded stone aggregateas in copings for electric pole and other similar work water troughs and the like, weathering, slightly rounded or chamfered angles etc including use & waste form work and demolition of old coping all as specified and directed
39S&F Cable jointing kit for straight through joint, heat shrink type joint for 1100 V grade cable complete with jointing material and accessories suitable for 3.5 / 4 core, 10 to 16 Sqmm XLPE armoured aluminium conductor cable. Note:- Excavation and earth work, extra cable if required will be measured & paid seperatly under respective items of this BOQ.
40All as per item No 39 above joint suitable for cable of size 25 to 50 Sqmm
41All as per item No 39 above joint suitable for cable of size 70 to 120 Sqmm
42All as per item No 39 above joint suitable for cable of size 150 to 185 Sqmm
43All as per item No 39 above joint suitable for cable of size 240 to 300 Sqmm
44Supply and installed steel tubular swaged pole type 410 SP - 31 (9 mtr long) complete with MS base plate of size 300 x 300 x 6mm thick at bottom, welded at the centre with through hole of 14 mm dia at a height of 300 mm above the coping finial cap and painted with two coats of aluminium paint over a coat of red oxide primer, making of strip of 300 mm width (balck and yellow in alternate band) upto 1500 mm height with one synthetic enamel paint, writing pole No with stencil with white colour in black background with synthetic enamel paint including excavation upto required depth and PCC type C-2 1:3:6 (using 40mm graded) at bottom and PCC type B-1 1:2:4 (20mm graded) for mass filling and pole coping (60x60x30cm) and rendering of coping with 5 mm thick in 1:3 cement mortar complete all as specified and directed.
45Supply and errectionin replacement07 mtr continuously tapered hot dip galvanised Octagonal cross sectional pole with single dipping method having bottom 130 mm A/F and top 70 mm A/F 3 mm thick confirming to ASTM A 572 Gr with yield 450mpa cut and folded to form an octagonal section and welded in accordance with AWS for wind loading as per IS 875 part 3 1987.Poles shall be provided with base plate of size 225x225x12 mm which shall be free from any lamination or incursion with no cutting or welding on the pole after hot dip galvanising with single arm 1000 mm long bracket tilted to 150 degree from horizontal toward vertices suitable for mounting on the octagonal pole, of company recommendationand one no TPN Connecton 3 phase 4 wire 100 Amps, and one number MCB SP 6 Amps. A triangular flat MS plat of 6mm thick duly coated with GI shall be welded between cap of the octagonal pole and bracket. Welding work shall be done 250mm on bracket and 150 mm on pole"s cap including all RCC work type (1:2:4) type B-1 including 04 Nos foundation nut bolt and plate as per pole manufacturer"s drawing and earth work all as per requirement complete all as specified and directed. Note Cost of construction of RCC foundation including construction material, necessary earth work and excavatonas per manufacturer design forabove polecompleteall as required at site and as directed by Engr-in-charge are deemed to be included in the quoted rate.
46S&F in repair MS Junction Box made of 1.6 mm thick MS sheet of size 300 x 200 x 150 mm with front openable hinged cover and locking arrangements with 4 Nos aluminium bus bar 100 Amps, mounted on porcelain insulator including MCB SP 10 Amp, 10 KA-1No, fixed on box in Din rail complete with electrical connection fixed to pole with suitable size FI clamp nut bolts and washer, painted with powder coated paint complete including required size and length of copper conductor cable and making connections completeall as specified and directed.
47S&F in repair On load change over switch, 63 Amps, 415 volts, 4 pole side handle type in sheet metal enclosure conforming to IS:13947 (Part-3); IEC:60947-3 with locking facility including all connecting / jointing materials and taking down existing change over switch, complete all specified & directed.
48S&F in repair offload change over switch, 200 Amps, 415 volts, 4 pole in sheet metal enclosure conforming to IS:13947 (Part-3), IEC:60947-3 with locking facility including all connecting / jointing materials and taking down existing change over switch, complete all specified & directed.
49S&F in repair off load change over switch (side operated handle) 400 Amps, 415 volts 4 pole in sheet metal enclosure with interlock door and pad lock facility including taking down existing change over switch, complete all specified & directed.
50Supply and fix in repair new generation, energy saving, environment friendly LED GATE LIGHT fitting, fully castaluminium body finish with polyeurethene paint with acryilic window cover with B 22 brass holder suitable for and including 15 to 20watt led lamp as light sopurce including making connections complete all as per specified and directed by the Engr-in-Charge. Make- MEPROCat part No. PTL-0002 Equivalant make approved by GE.
51Supply and fix in repair new generation, energy saving, environment friendly 25 watt LED POST TOP LANTERN fitting, aluminium spun landscape luminaires with and including LED lamp including making connections complete all as per specified and directed by the Engr-in-Charge.
52Supply, installing, testing and commissioning in replacementfactory made, CPRI approved, powder coatedLT Panel board confirming to IS 5039, (Dimention of Cubical / enclosure not less than 1500 mm x 1000 mm x 500 mm), cubical compartmentalized, out door type double door, plate form mounted, suitable for 415 volts, 3 phase, 4 wire, 50 HzAC supply system having bus bar chamber with insulated aluminium bus bars four pole installed on porcelain / SMC insulator. The panel shall be dust and vermin proofIP-54 class protection and outer shell made of of 3.15 mm CRCA MS sheet, inner shell made of 2.0 mm thick CRCA MS sheet , 50 x 50 x 6mm thick MS angle iron frame work, the cubical have bottom channel of size 75 x 40mm duly powder coated with zink metal coating, front and rear opening type, with apron for cable entry closing locking arrangement including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked,1100 volts grade of appropriate size ( but not less than 2.5 Sqmm)and comprising of the following:-
53(A) incoming (i) MCCB4 P 400 Amps, fixed type, 36 KA -01 Nos. (B) Outgiong (i) MCCBs 4P 200 Amps, fixed type, 25 KA- 01 No (ii) MCCBs 4P 160 Amps, fixed type, 25 KA - 02 Nos (iii) MCCBs4P 100Amps, fixed type, 25 KA-02 nos (C)Accessories - (i) copper bus bar rating600 Amps - 04 Nos. (ii) digital Volt meter 0-500V with selector switch-01 No, (iii) digital Amp meter 0-300 amp with CT and selector switch-01 No (iv) Indicating lamp-01 Set (LED Type)
54(D) Platform of Panel. Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class "B", old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel.The platform shall be such that it is of a height 45 cm above the nearest road level. Note :- (i) All out going feeder shall be connected by cable through suitable size gland plate / glands. (ii) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint. (iii) All MCCBwithadjustable protection for over load and short circuit and conforming to IEC60947-II/IS 13947-II (Latest Version). The MCCB should have Ics=100%Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacturer
55Supply, installing, testing and commissioning in replacementfactory made, CPRI approved, powder coatedLT Panel board confirming to IS 5039, (Dimention of Cubical / enclosure not less than 1500 mm x 1000 mm x 500 mm), cubical compartmentalized, out door type double door, plate form mounted, suitable for 415 volts, 3 phase, 4 wire, 50 HzAC supply system having bus bar chamber with insulated aluminium bus bars four pole installed on porcelain / SMC insulator. The panel shall be dust and vermin proofIP-54 class protection and outer shell made of of 3.15 mm CRCA MS sheet, inner shell made of 2.0 mm thick CRCA MS sheet , 50 x 50 x 6mm thick MS angle iron frame work, the cubical have bottom channel of size 75 x 40mm duly powder coated with zink metal coating, front and rear opening type, with apron for cable entry closing locking arrangement including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked,1100 volts grade of appropriate size ( but not less than 2.5 Sqmm)and comprising of the following:-
56A) incoming (i) MCCB4P 250Amps , fixed type ,36 KA -01 Nos. (B) Outgiong (i) MCCBs4P 160 Amps , fixed type, 25 KA - 02 Nos (ii) MCCBs4P 63Amps , fixed type, 25 KA-03 Nos (C)Accessories (i) Copper bus bar rating400 Amps -04 Nos. (ii) digital Volt meter 0-500V with selector switch-01 No (iii) digital Amp meter 0-300 amp with CT and selector switch-01 No (iv) Indicating lamp-01 Set (LED Type)
57(D) Platform of Panel. Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class "B", old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel.The platform shall be such that it is of a height 45 cm above the nearest road level. Note :- (i) All out going feeder shall be connected by cable through suitable size gland plate / glands. (ii) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint. (iii) All MCCBwithadjustable protection for over load and short circuit and conforming to IEC60947-II/IS 13947-II (Latest Version). The MCCB should have Ics=100%Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacturer
58S&F in replacement out door type busbar panel board (Dimention of Cubical / enclosure not less than 600 mm x 450 mm x 450 mm) made out of3.15 mm thick MS sheet and MS angle section 50 x 50 x 6 mm factory made suitable for 3 phase 4 wire 415 Volt, 50 Hz, powder coat painted comprising of the following:- (a)FP, Aluminium bus bar 500 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators. (b) Incoming MCCB 250 Amps 36 KA, 415 Vots, 50 Hz, FP.– 1 No (c)LED Indicator lamp RYB - 01 set of three.
59(d) Platform of Panel. Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class "B", old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel.The platform shall be such that it is of a height 45 cm above the nearest road level. Note :- (i) All out going feeder shall be connected by cable through suitable size gland plate / glands. (ii) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint. (iii) All MCCBwithadjustable protection for over load and short circuit and conforming to IEC60947-II/IS 13947-II (Latest Version). The MCCB should have Ics=100%Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacturer
60M&L in replacement Earthing complete with galvanised mild steel earth plate electrode 600x600x6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI strip 32 x 6 mm as earth strip electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth strip encased inand including 40 mm dia GI "lightgrade" pipe from upper end of earth plate upto equipments,20 dia bore GI pipe "light grade" as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe andPCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS TMT bars 8mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as describedin electric plate of SSR Part I completeall as specified and directed and testing on completion. Note :- Ifthe desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
61M&L in replacement Earthing complete with Copper earthPlate electrode 60x60cmx3.15mm thick, burried directly in ground ( earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, Including connected to copper strip 20x3mmlead (upto 7.5 Mtr) by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate connected to earthing test point all as specified or indicated including testing on completion.ith salt to a packed thickness of 15 cm all around the plate, and including 40 mm dia GI "lightgrade" pipe from upper end of earth plate upto equipments,20 dia bore GI pipe "light grade" as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe andPCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS TMT bars 8mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as describedin electric plate of SSR Part I completeall as specified and directed and testing on completion. Note :- Ifthe desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
62Supply and fix in replacement 35 W LED street light fitting with mandatory driver set having pressure die cast aluminium housing with high efficiency LEDs as lighting source and lens embaded PC cover /IP lens, street lightshould haveIP 66 protection, impact resistance ofIK 07 , Lumen efficiency of LED not less than 110 lumen per wattsystem efficency ,power factor >0.95, THD<10% at Full load CRI> 70% ,street light should have built in potted electronic LED driver with , lower THD, open circuit protection , over voltage protection , surge voltage protection ,andprovided with company LOGO ingraved on housing of the street lightcomplete including taking down of oldUNSV fittings all as specified and directed by Engr -in-Charge. Note :-The contractor shouldtake approval of techincal specification ofluminaries and driver from department before procurement .
63All as per Item No 57 above but 60 watt LED street light fitting.
64All as per Item No 57 above but 90 watt LED street light fitting.
65All as per Item No 57 above but 120 watt LED street light fitting.
66Supply & fix in replacement GI brackets made of 40 mm nominal bore GI pipemedium grade of required length not less than 1.5 M long, mounting brackets made out of Mild steel FI 40x6 mm of required shape ( two Nos) duly fitted with Mild steel nuts, bolts and washers and painting with two coats of synthetic enamelled paint over one coat of red oxide primer and fixed to pole / walls etc complete all as specified & directed by Engr-in-Charge.
67Supply and fixing in replacement of 70 W LED flood fitting having epoxy powder coated die cast aluminium housing in grey finish with elegantly designed heat sink for efficient thermal management, sturdiness & excellent corrosion resistant. PG9 gland is used for cable entry and provision for loopin -loopout , PC lens/IP lens with narrow /wide beam distribution and toughened glass fixed to housing withscrews , floodlightshould haveIP 66 protectionand impact resistance ofIK 07 , Lumen efficiency of LED not less than 110 lumen per wattsystem efficency, power factor >0.95, THD<10% at Full load CRI> 70% ,flood light should have built in pottedelectronic LED driver with , lower THD, open circuit protection , over voltage protection , surge voltage protection ,andprovided with company LOGO ingraved on housing of the floodlightcomplete including taking down of oldUNSV fittings all as specified and directed by Engr -in-Charge. Note :-The contractor should take approval of techincal specification ofluminaries and driver from department before procurement .
68All as per Item No 62 above but 120 watt LED Flood light fitting.
69All as per Item No 62 above but 170 watt LED Flood light fitting.
70All as per Item No 62 above but 210 watt LED Flood light fitting.
71Supply & fix in replacementautomatic street light timer panel 5 KW switch using Infrared Sensor basedfor automatic switching of street lights based on LUX level of natural light, required illuminance for switching ON is < 30 Lux and for switching OFF > 10 Lux level, The sensor (nature switch) alongwith suitable power contactors, Input (supply) MCB and output (load) MCB(s), support terminals should be enclosed in pole/ wall mountable enclosure made of rust proof, electric shock proof, termite proof and FR graded SMC junction box conforming to IP-54 degree of protection including mounting bracket, cable glands, openable doors with lock complete all as specified & directed by Engr-in-Charge.
72Supply, installation, testing & commisioning exterior BIS registered RGBW Linear LED Wall Washer luminaire for facade lighting with extruded aluminium housing, powder-coated finish, Clear toughened glass of 4 mm thickness and die casted end caps, of Total System wattage 24 W with system lumen output 1393 lm with all LEDs on, Luminaire shall be capable of producing dynamic color changing light with 16 million colors as the light fixture should be programmable using 8 bit control DMX512 protocol / Ethernet based control. Luminaire shall be conforming to BIS i.e. IS 10322 (Part 5/Sec 5) and shall be complete with all necessary accessories required for proper working of fixture, weather proof connection cables, water proof connectors etc. including taking down old light fitting complete.
73Supply, Installation, Testing and Commissioning exterior BIS registered LED RGB flood lighting luminaire for facade lighting with Die-cast aluminium housing, powder-coated finish, Clear toughened glass of 4 mm thickness, of Total System wattage28 W with system lumen output 1641 lm with all LEDs on,Luminaire shall be capable of producing dynamic color changing lightwith 16 million colors as the light fixture should be programmable using 8 bit control DMX512 protocol / Ethernet based control . Luminaire shall be conforming to BIS i.e. IS 10322 (Part 5/Sec 5) and shall be complete with all necessary accessories required for proper working of fixture, weather proof connection cables, water proof connectors etc. including taking down old light fitting complete.
74Supply, Installation, Testing & Commisioning exterior BIS registered LED RGBW flood lighting luminaire for facade lighting with Die-cast aluminium housing, powder-coated finish, Clear toughened glass of 4 mm thickness, of Total System wattage45 W with system lumen output 2379 lm with all LEDs on, Luminaire shall be capable of producing dynamic color changing lightwith 16 million colors as the light fixture should be programmable using 8 bit control DMX512 protocol / Ethernet based control.Luminaire shall be conforming to BIS i.e. IS 10322 (Part 5/Sec 5) and shall be complete with all necessary accessories required for proper working of fixture, weather proof connection cables, water proof connectors etc. including taking down old light fitting complete.
75Supply, Installation, Testing & Commisioning of exterior BIS registered RGBW Flexible LED Strip with 14.4 Watt per meter. LED Strip should have 60 Nos LEDs per meter through out the length with the silicon cover with system lumens 708 lms / meter and System. Standard Length of LED Strip is 5 mtr and it shall be capable of producing dynamic color changing light for with 16 million colors and should be programmable using 8 bit control DMX512 protocol / Ethernet based control. The Strip should have IP 67 protection with inbuilt IP67 connectors at both ends. led strip shall be complete with all necessary accessories required for proper working of fixture, weather proof connection cables, water proof connectors etc. etc. including taking down old light fitting complete.
76Deployment of tools, manpower etc for lowering the high mast light, height of 25 mtr and repairs to the extent by removing connections from the system, checking of unserviceable spare parts and serviceable parts, replacement of unserviceable parts with new spares and testing complete, tightening the loose connection and made item functional, reassembling the fitting and re-fixing/ re-hanging the same after repair in existing location and tesing complete all as specified and directed by Engineer-in-Charge. Note : (a) Spares required for repair shall be measured and paid separately as supply only items vide BOQ item No 72 to 74 (b) The contractor shall provide all type and safety equipment & other tools required at site to electrician for maintenance of light (c) In case any accident/injury of any person deputed by contractor shall be held responsible for setting all claims/compensation. (d) all other item also included in the works which not catered in items
77Supply only gear box sutable for high mast lighting system as per existing size, capacity and make.
78Supply only motor sutable for high mast lighting system as per existing size,capacity and make.
79Supply only controll switch sutable for high mast lighting system as per existing size, capacity and make .