Bids Are Invited For Ujjain Supply Of Split Ac , Itc Of Split Ac , Supply Fixing Copper Piping , Supply Fixing Pvc Drain Piping , Providing Fixing Ms Stand , Supply Fixing 3 Core 2.5 Sqmm Cu. Cable , Supplying And Gas Charging Sitc Of Inverter Type A, Indore-Madhya Pradesh

Department Of Telecommunications has published Bids Are Invited For Ujjain Supply Of Split Ac , Itc Of Split Ac , Supply Fixing Copper Piping , Supply Fixing Pvc Drain Piping , Providing Fixing Ms Stand , Supply Fixing 3 Core 2.5 Sqmm Cu. Cable , Supplying And Gas Charging Sitc Of Inverter Type A. Submission Date for this Tender is 02-05-2024. Air Conditioner Tenders in Indore Madhya Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

43118123
Corrigendum : Bids Are Invited For Ujjain Supply Of Split Ac , Itc Of Split Ac , Supply Fixing Copper Piping , Supply Fixing Pvc Drain Piping , Providing Fixing Ms Stand , Supply Fixing 3 Core 2.5 Sqmm Cu. Cable , Supplying And Gas Charging Sitc Of Inverter Type A
Open Tender
Indian
Madhya Pradesh
Indore
02-05-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Bids Are Invited For Ujjain Supply Of Split Ac , Itc Of Split Ac , Supply Fixing Copper Piping , Supply Fixing Pvc Drain Piping , Providing Fixing Ms Stand , Supply Fixing 3 Core 2.5 Sqmm Cu. Cable , Supplying And Gas Charging Sitc Of Inverter Type Ac 5 Star For Maan Project Total Quantity : 107

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 23-Apr-2024 02-05-2024

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
INR 3.99 Lakhs /-

Attachment

FileName File Description File Size
6292012_Boq_6.xlsx Tender Document 0 KB
095c65bf-79f8-44e0-8a07-3b9345d97803.pdf Tender Notice 0 KB

BOQ Items

Sl. No. Item TitleItem Description
1Supply of Split ACSupplyingof 1.5 TR inverter type 5Star ratedsplit AC unit of 230 V , 50Hz, 1 phase AC supplywith copper cooling and condenser coil Including indoor and outdoor unit with factory refrigerant charge R-32/R410 withRotary/scroll Compressor , AC unit ( Not less than 4500 BTU/hr).Latest compatible refrigerant (environment friendly) should be used.The split AC should be BEE 5starrating ,ISI markminimum (ISEER) not less than 5.4with temperature control thermistor, remote control unit, filters, rotary / scroll type compressor, copper tubesfor both indoor and outdoor unit,topping up of refrigerantif required, including transportation etc .as required supplying the following up to the length of 3 mtrs etc as required.(1) hot and cold refrigerant piping each and (2) suitable connecting electrical cable between indoor and out door unit
2ITC of Split ACInstallation, Testing and commissioning of 1.5 TRinverter type splitAC unit along with the copper piping, wiring up to the standard length of 3 mtrs (supplied as under Item.1) including gas charging, insulation and making opening in wall and making good the damages etc., as required.
3Supply fixing Copper PipingSupplying and fixing extra copper pipe line both1/4inch for gas line and 5/8inchfor liquid line OR suitable dia to match with the pipeline of the new unit along with suitable size rubber foam/insulation on surface of the wall i/c necessary flare nuts,suitably brazing with the existing pipe clamping, making holes in walls,same etc., as per site requirement.(NOTEThe length of refrigerant pipes supplied with each A.C units is 3 Metre. Extra length shall be paid extra for which firm shall quote their unit rates.
4Supply fixing PVC Drain PipingProviding and fixing 20mm dia PVC pipe for drain water arrangement for the above AC units including bends, elbows complete as required.
5Providing Fixing MS StandSupplying and fixing of powder coated heavy dutypre fabricatediron standfor wall mounting outdoor unit of the above AC i/c providingnecessary hardware etc complete as required.
6Supply fixing 3 core 2.5 Sqmm CU. CableSupplying and laying 3core 2.5sqmm PVC insulated and PVC sheathed flexible copper cable along with refrigerant pipe or along with existing conduit / cable tray i/c binding with plastic tags for extending supply from existing industrial socket to indoor unit etc, as required . Make any ISI mark . NOTE The length of Copper Cable supplied with each unit is 3 Metre . Extra length shall be paid extra for which firm shall quote their unit rates
7Supplying and Gas ChargingSupplying and gas charging with R32 gas in split AC unit etc complete as required.