|
| 1 | Supply and fixing in repair of cable straight through jointing kit for 11 KV grade (Earthed) cable termination heat shrink type joint complete with jointing material and all accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 Sqmm complete all as specified and directed by Eng-in-Charge. |
| 2 | Supply and fixing in repair cable end jointing kit for 11 KV grade (Earthed) cable for indoor termination heat shrink type joint complete with jointing material and all accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 Sqmm. Complete all as specified and directed by Eng-in-Charge. |
| 3 | Supply and fixin repaircable end jointing kit for 11 KV grade (Earthed) cable for outdoor termination heat shrink type joint complete with jointing material and all accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 70 to 95 Sqmm complete all as specified and directed by Eng-in-Charge. |
| 4 | Supply and fixing in repaircable end jointing kit for 11 KV grade (Earthed) cable for outdoor termination heat shrink type joint complete with jointing material and all accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 Sqmm complete all as specified and directed by Eng-in-Charge. |
| 5 | Supply and fixing in repair Cable jointing kit for 11 KV (Earthed) grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and directed by Eng-in-Charge. |
| 6 | M & L for aluminium conductor, steel reinforced (ACSR) weasel type conductor for LT lines on PCC/steel tubular poles, stretching without kinks and bends including binding wire complete all as specified and directed by Eng-in-Charge. |
| 7 | M&L for cross arms, bracings, supports, clamps and back plates fabricated from steel section including nuts, bolts, washers, welding bending cold or hot drilling holes for bolts in any shape ors size as indicated or directed and inclusive ofone primer coat, one under coat and one finishing coat of aluminium paint complete all as specified and directed by Eng-in-Charge. |
| 8 | Material and labour for GI tubing light grade 80mm dia bore with fittings laid for protection of cable under road crossing fixed to walls or pole complete all as specified and directed by Eng-in-Charge.(clamps for fixing pipe, nuts, bolts washers shall be measured separately ) |
| 9 | All as per Srl Item No 8.00 above but size of 40mm dia bore complete all as specified and directed by Eng-in-Charge. |
| 10 | Earthing complete with GI earth plate electrode of size 60cm X 60cm X 6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers etc and connected to and including GI strip of size 32x6 mm up to 7.5 mtr by means of bolts, nuts, check nuts and washers made of brass and protected by light grade 40mm dia upto 7.5 mtr long GI pipe connected to main controlboard and GI pipe light grade 20mm bore for watering and including funnel, wire mesh, RCC pit cover 50mm thick and PCC chamber pit with PCC 1:2:4 type C-2 (including excavation and earth work disposal of surplus soil to a distance not exceeding 50 metre) and testing making test point and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009 including taking down old unserviceable complete all as specified & directed by Engr-in-charge. |
| 11 | M & L for marking/writing feeder names/ SM No / MES No for HT/LT Electrical Equipments like VCB, Tfrs, LBS / RMU/panels etc with synthetic enamel paintOr Stickers equivalent of approved color by GE complete all as specified and directed by Eng-in-Charge. |
| 12 | Servicing of switch air break gang operated device (GOD) 200 Amps, 11 KV, by cleaning moving / fix contact jaw ,MS jumper / MS jumper carrier including replacement of ACSR Jumpers with PG clamps, nut bolts etc and providing white petroleum jelly and making all connection tightened and aluminium lugs etc complete and testing on full operating etc complete all as specified and directed by Eng-in-Charge. |
| 13 | Supply and fixing in repair switch air break gang operated device (GOD) 200 Amps, 11 KV ,MS jumper / MS jumper carrier including replacement of ACSR Jumpers with PG clamps, nut bolts etc and providing white petroleum jelly and making all connection tightened and aluminium lugs etc. complete and testing on full operating etc all as specified and directed. |
| 14 | Material and labour in replacement of lightning arrester expulsion type, suitable for 11000 Volt, with all fittings, trasmission class, discharge capacity 65 KA including connecting with HT line and dismantling and taking down of old unserviceable lightning arrester complete all as specified and directed by Eng-in-Charge. |
| 15 | M&L in repair pin type insulator, porcelain, vitreous, white, brown or green insulator including one galvanized mild steel spindle, two GI washers and one GI nut, 100mm height, 65mm dia for 1100 volts grade complete all as specified and directed by Eng-in-Charge. |
| 16 | M&L in repair for shackle type, porcelain, vitreous, white, brown or green insulator including galvanized mild steel straps, washers, insulator bolts, washers and nuts of size 75mm height and 90mm dia size of strap 31x3mm and dia of bolts 12mm for working pressure 1100 volts grade complete all as specified and directed by Eng-in-Charge. |
| 17 | M&L in repair for loop type insulator, vitreous porcelain white, brown or green large size with overall dimensions 90mmx140mm clearance of hole 25.5mm Complete all as specified and directed by Eng-in-Charge. |
| 18 | Supply and laying in replacement ofXLPE insulated screened PVC bedded galvanised steel strip armoured electric power dable heavy duty 1100 Volt grade with stranded aluminium conductor of size16Sq mm 4 core complete all as specified and directed by Eng-in-Charge. |
| 19 | All as per Items No 18.00 above but ofsize 25 sq mm 4 core complete all as specified and directed by Eng-in-Charge. |
| 20 | All as per Items No 18.00 above but ofsize 35 sq mm 3.5 core complete all as specified and directed by Eng-in-Charge. |
| 21 | All as per Items No 18.00 above but ofsize 50 sq mm 3.5 core complete all as specified and directed by Eng-in-Charge. |
| 22 | Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundation, shafts, man holes,for under ground cable / erection of poles, stays etc not exceeding 10 Square metre on plan and getting out in hard/dense soil including dressing/trimming of sides and leveling, grading and ramming of bottom of excavation complete all as specified and directed by Eng-in-Charge. |
| 23 | All as per item No. 22 above but excavation depth exceeding 1.5 metre and not exceeding 3.0 metre complete all as specified and directed by Eng-in-Charge. |
| 24 | Removing of surplus soil to a distance not exceeding 50 mtr complete all as specified and deposited where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed by Eng-in-Charge. |
| 25 | Returning filing in including spreading levelling, watering & well ramming in layers not exceeding 25 CM thick All as per Items No 18.00 above but ofsize 25 sq mm 4 core complete all as specified and directed by Eng-in-Charge. |
| 26 | Material & Labour for sand cushioning 15 cm below and 8 cm above the U/G cable laid (total depth of sand shall be 18 cm) complete all as specified & directed by Engr-in-Charge. |
| 27 | M & L for providing PCC cable cover class LV type-I of size 250x150x40mm laid in perpendicular to the cable abutting each otherat at site complete all as specified and directed by Eng-in-Charge. |
| 28 | Supply and erection truely vertical position steel tubular swaged pole complete with cast iron base plate finial taper plug, bolts, nuts and screws as specified type 410 SP-31 (9.0 mtr long) including painting with two coats of aluminium paint over one coat of red oxide primer, with black and white strips 30 cm each starting with black strip upto 1.5 mtrcomplete all as specified and directed by Eng-in-Charge. |
| 29 | M&L Plain cement concrete 1:3:6 type C-2 using 40 mm graded crushed stone aggregate as in foundation filling and mass concrete for stays foundation and platform for transformer installation complete all as specified and directed by Eng-in-Charge. |
| 30 | M&L Plain cement concrete 1:2:4, Type B-1 by using 20 mm graded granite stone aggregate in copingincluding necessary form work and finishing exposed surfaces fair & even complete all as specified and directed by Eng-in-Charge. |
| 31 | M&L Plain cement concrete 1:4:8, Type D-2by using 40 mm graded granite stone aggregate for base (bottom of pit for Bed Concrete) including necessary form work and finishing exposed surfaces fair & even complete all as specified and directed by Eng-in-Charge. |
| 32 | Supply and fixing of stay assembly complete with all accessories such as stay plate300mmx300mmx6mm, stay rod 20 mm dia and 215cm long threaded end with nuts including 14mm dia GI stay bow. turn buckle, etc. complete, all as shown in Electrical plate No 1 of SSR part I 2009 complete including dismantling and taking down of old unserviceable stay assembly complete all as specified and directed by Eng-in-Charge.Note:- The quoted rate shall include the cost of loop type insulator, stay clamps, excavation, PCC, stay wire, stay bow, turn buckle, nuts etc., excavation, demolition and removal of demolished concrete outside defence land complete. |
| 33 | M & L forpainting to existing Steel tubular LT poles, 8.5/9 m long including cross arms, channels, angle iron support, bracings, clamps etc, with two coats of aluminum paint superior quality of approved make on surfaces exposed to view and making 30cm wide strips (total 5 Nos) with white and black paint alternately on external surface above PCC benching including preparation of old painted surfaces by scraping including writing MES LT feeder No and pole No (in capital letters ) stencil cut decorative manner on pole using fluorescent paint complete all as specified and directed by Eng-in-Charge. |
| 34 | supply and fixing in repair ofCT 20/5APT 11KV/110 Voltfor 11 kv metering panel including welding of broken panel doors (any number of shutters) and hinges (any size any number of hinges per panel) of suitable size for making open and close the panel doors including bends etc and fixing locking arrangement of the doors complete all as specified and directed by Eng-in-Charge. |
| 35 | Supply and spreding graded crushed stone aggregate 40mm size around two pole/ four pole structure in 15 cm thickness after cleaning area byremoving existing wild grass,vegetation,creepers, small plants / bushes etc complete all as specified and directed by Eng-in-Charge. |
| 36 | Restretching of ACSR conductor and earth wire of any size and type on HT/LT poles including disconnecting and rebinding with insulators with suitable size of binding wire after restretching, connecting, jumpers, adjusting line deviders etc complete all as directed by Engineer-in-Charge.(Note:- Single length of the conductor shall be measured). |
| 37 | Supply and fixing in replacement of PVC LT line separator 4/5 way, complete all as specified and directed by Eng-in-Charge. |
| 38 | Supply and fixing in repairof PVC LT line separators 2/3 way, complete all as specified and directed by Eng-in-Charge. |
| 39 | Deduct Credit for Demolished/Dismantled material Rs (-) 36790.00 (Minus) as listed in Schedule \"A\" Sec-II (Credit Schedule)Note :Tenderers will not quote against this item being a tentative amount, to be considered to arrive at the \"Contract Sum\". |