Tender For Comprehensive Preventive And Breakdown Maintenance Of Various 765/400/220/132 Kv Transmission Line Under Etc, Mirzapur, mirzapur-Uttar Pradesh

Uttar Pradesh Power Transmission Corporation Limited-UPPTCL has published Tender For Comprehensive Preventive And Breakdown Maintenance Of Various 765/400/220/132 Kv Transmission Line Under Etc, Mirzapur. Submission Date for this Tender is 15-04-2024. Transmission Line Tenders in mirzapur Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

43116008
Tender For Comprehensive Preventive And Breakdown Maintenance Of Various 765/400/220/132 Kv Transmission Line Under Etc, Mirzapur
Open Tender
Indian
Uttar Pradesh
mirzapur
15-04-2024

Tender Details

Comprehensive Preventive And Breakdown Maintenance Of Various 765/400/220/132 Kv Transmission Line Under Etc, Mirzapur

Key Value

Document Fees
INR 2950 /-
EMD
INR 300000.0 /-
Tender Value
INR 2.37 Crore /-

BOQ Items

Name of Work:Comprehensive Preventive & Break Down Maintenance job of different 765/400/220/132KV Transmission lines under Electricity Transmission Circle, Mirzapur
Sl. No. Item Description
1Comprehensive Preventive & Break Down Maintenance job of different 765/400/220/132KV Transmission lines under Electricity Transmission Circle, Mirzapur as per following :-
2Comprehensive Regular Preventive & Break Down Maintenance job of different 765/400/220/132KV Transmission lines for smooth operation of transmission lines under Transmission Divisions as per Details and Technical Specifications describedin Vol-II by Providing of Gangs/Establishment of Site Offices with Main Store/Site Store near designated Substation as detailed below comprising of skilled man power and T&Ps along with Establishment of Site Office for carring out various activities including Tower to tower patrolling and submission of patrolling report in prescribed format including photograph of defects, Emergency Patrolling, Lopping & chopping of tree branches/Bamboo Kothi coming in the corridor of the line, Thermography of Jumpers / Joints,Rectification of the line defects such as fixing of missing/stolen tower parts, Fixing of dislocated/New Vibration Dampers, Checking and tightness of jumpers, Cleaning of Disc Insulators etc. and attending of break down such as Replacement of damaged Jumpers, Replacement of damaged/broken Earth wire/OPGW, Replacement of damaged/ broken Quad moose/Deer/Zebra/Panther conductors, Repairing of coping with materials, backfilling of soil, Replacement of damaged/broken Tension/Suspension Insulators string, Repair of minor damages of Tower such as damage of Cross Arms/Tower Peaks including other associated works with all T&P and additional Man Power as needed. The T&P as per list in Vol-II shall be maintained by the Contractor at Main Site Office and other Site Offices. All the spare materials including special Testing Instruments will be provided by the UPPTCL except name/danger/page plates which shall be under the scope of contractor.Comprehensive maintenance of 220 KV & 132 KV lines will be started w.e.f. 01.04.2025.
3Electricity Transmission Division, Mirzapur (220 KV lines - 228.98 Ckt. Km., 132 KV lines- 184.84 Ckt. Km.)
4Carrying out Comprehensive Maintenance workby a Gang comprising of minimum 01 No. Site Supervisior, 04 Nos.Skilled Technician (Fitter) equipped with 01 No. Pickup or equivalent vehicle along with Driver suitable to shift men, T&P, special T&P and Material as per Technical Specifications including Establishment of Site Office with Site Store having T&P as described in Appendix-B Vol-II(1 Job Per Month)
5Carrying out Comprehensive Maintenance work by a Sub Gang comprising of minimum of 06 Nos.Skilled Technician (Fitter) with 01 No. Site Supervisior as per technical specifications(1 Job Per Month)
6Electricity Transmission Division, Robertsganj (765 KV Anpara D"-Unnao transmission line - Total line length 186.908 Km. , 400 KV Anpara-B to Anpara D DC line Loc No. 01 to 23 line length-5 Km., 765 KV Anpara C- to Anpara D SC line(Loc. No. 01 to 11) line length-2.60 Km Location no. 262-369 total 94.06 Km of 765 KV Anpara D-Jhusi line clubed in ETD Robertsganj)
7Carrying out Comprehensive Maintenance workby a Gang comprising of minimum01 No. supervisor, 05 Nos.Skilled Technician (Fitter) equipped with 01 Nos. Pickup or equivalent vehicle along with Driver suitable to shift men, T&P, special T&P and Material as per Technical Specifications including Establishment of Site Office with Site Store having T&P as described in Appendix-B Vol-II(1 Job Per Month) .
8Electricity Transmission Division Roberrtsganj ( 220 KV lines -327.60 Ckt. Km., 132 KV lines- 349.32 Ckt. Km.)
9Carrying out Comprehensive Maintenance work by a Gang comprising of minimum 01 No. Site Supervisior, 04 Nos.Skilled Technician (Fitter) equipped with 01 No. Pickup or equivalent vehicle along with Driver suitable to shift men, T&P, special T&P and Material as per Technical Specifications including Establishment of Site Office with Site Store having T&P as described in Appendix-B Vol-II (1 Job Per Month)
10Carrying out Comprehensive Maintenance work by a Gang comprising of minimum 01 No. Site Supervisior, 04 Nos.Skilled Technician (Fitter) equipped with 01 No. Pickup or equivalent vehicle along with Driver suitable to shift men, T&P, special T&P and Material as per Technical Specifications including Establishment of Site Office with Site Store having T&P as described in Appendix-B Vol-II (1 Job Per Month)
11Carrying out Comprehensive Maintenance work by a Sub Gang comprising of minimum of 08 Nos.Skilled Technician (Fitter) as per technical specifications(1 Job Per Month)
12Electricity Transmission Division-IV, Varanasi (132 KV lines- 144.81 Ckt. Km.) 220 KV lines -8.04 Ckt. Km.
13Carrying out Comprehensive Maintenance work by a Gang comprising of minimum 01 No. Site Supervisior, 04 Nos.Skilled Technician (Fitter) equipped with 01 No. Pickup or equivalent vehicle along with Driver suitable to shift men, T&P, special T&P and Material as per Technical Specifications including Establishment of Site Office with Site Store having T&P as described in Appendix-B Vol-II (1 Job Per Month).The gang will look after all the under construction lines under ETD-IV, Varanasi as per direction of Engineer incharge.
14Thermovision Scaning - Thermal scanning of Transmission lines by high resolutionInfrared Auto Focus Camera having min. resolution of 240*320 using telephoto lenses of 7-14 deg (min. dist. 150 meter) of all Sections Tower Jumpers including all mid-span joints during on load conditions and providing coloured print of report in to sets. (May & September) NOTE:- (Thermo- Vision Camera as per technical specification arranged by contractor own end)
15Thermovision Scaning of 765 KV Total line two times in a year
16Thermovision Scaning of 400 KV Total line two times in a year
17Thermovision Scaning of 220/132 KV Total line two times in a year