Mahanadi Coalfields Limited has published Tender For Operation, Repairing And Maintenance Of Pump, Water Sprinklers, Static Type Fog Canon, And Ms Pipeline Installed For Dust Suppression At Kanika Railway Siding Of Garjanbahal Ocp, Basundhara Area. Submission Date for this Tender is 16-04-2024. Mechanical engineering Service Tenders in basundhara Odisha. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Opearation of Pump ,Fog Canon,Sprinkler System (02 Semi skilled and 02 Unskilled ) |
2 | Dismantling and Fixing ofriser assembly 3mtr height, dia 2" andinstallation of sprinkler nozzle(including supply of pipe & pipe accessories valve,nozzle sprinkler full circle 72 mtretc with M.S pipe on required location |
3 | Dismantling and repairing/replacement ofexisting (6"and 4") MS pipeline as and when requird at Kanika siding |
4 | Supply riser 3mtr height, dia 2" for installation of sprinkler (including supply of pipe & pipe accessories valve, iron angle to hold the riser assemblyetc) with M.S pipe line. |
5 | Supply of sprinklers, made of brass twin nozzle sprinkler, full circle dia meter spray- 72 mtr,working presurre-2- 5 kg/cm², 400LPM2" BSP inlet connectionto the sprinkler assembly. |
6 | Replacement of Voltage Relay (Under voltage, Over voltage with Phase failure protection) 3-Phase upto 510V. |
7 | Replacement of Water level controller, Adjustable sensitivity 1K to 200K Ohm with sensor. |
8 | Replacement of MCB, 1 Pole, 6A. |
9 | Replacement of MCB, 3 Pole, 63A. |
10 | Replacement of MCB, 3 Pole, 2A. |
11 | Replacement of AC Contactor, Coil Voltage: 440 V AC, Current Rating 12A, 3 Pole, (1NO + 1NC). |
12 | Replacement of AC Contactor, Coil Voltage: 440 V AC, Current Rating 50A, 3 Pole,(1NO + 1NC). |
13 | Replacement of AC Contactor, Coil Voltage: 440 V AC, Current Rating 65A, 3 Pole,(1NO + 1NC). |
14 | Replacement of AC Contactor, Coil Voltage: 440 V AC, Current Rating 40A, 3 Pole,(1NO + 1NC). |
15 | Replacement of Bimetal Overload Relay, Current Range: 0.1 to 13 A. |
16 | Replacement of Bimetal Overload Relay, Current Range: 55 to 70 A. |
17 | Replacement of Bimetal Overload Relay, Current Range: 23 to 50 A. |
18 | MCCB 3 POLE, 160A. |
19 | Replacement of Relay, M - Series, Coil Voltage: 240 V AC. |
20 | Replacement of Star Delta timer, Run time: 30 / 60sec, Change over: 50 / 100ms, 2 C/O, 230 to 450V AC. |
21 | Replacement of PT, 440V/220V AC, 500 VA, Single Phase. |
22 | Replacement of LED Type Push Button Actuators - Illuminated. |
23 | Replacement of LED Type Pilot Lamp-Type of voltage AC/DC. |
24 | Replacement of Mushroom Head Push Button Stay Put (press to lock, turn to release). |
25 | Selector Switch Actuators with Carrier 2 Position with 1 NO Block. |
26 | Replacement ofKD-8108-M Limit Switch. |
27 | Replacement of Rubber hose High Impulse, DIN EN853-1S, 1 1/2" dia, 3 mtr. Long complete with end fittings (Ferrules). |
28 | Maintenance of Fog Canon assembly including cleaning of Nozzels, Panel, Greasingetc. and Replacement of defective parts (Except Monsoon season). |
29 | Total impact of GST plus Labour Cess [@ 1 % (BOCW Cess to be deducted from the RA bill as per the value of the work progress)] for the purpose of CTC |