Tender For Addition/ Alteration To Civil And Electrical Works For Building No P-128 And P-03 At Drdo Township, Kanchanbagh, Hyderabad, hyderabad-Telangana

Military Engineer Services-MES has published Tender For Addition/ Alteration To Civil And Electrical Works For Building No P-128 And P-03 At Drdo Township, Kanchanbagh, Hyderabad. Submission Date for this Tender is 19-04-2024. Electrical Maintenance Tenders in hyderabad Telangana. Bidders can get complete Tender details and download the document.




Tender Notice

43108001
Tender For Addition/ Alteration To Civil And Electrical Works For Building No P-128 And P-03 At Drdo Township, Kanchanbagh, Hyderabad
Open Tender
Indian
Telangana
hyderabad
19-04-2024

Tender Details

Addition/ Alteration To Civil And Electrical Works For Building No P-128 And P-03 At Drdo Township, Kanchanbagh, Hyderabad

Key Value

Document Fees
INR 500 /-
EMD
INR 98000.0 /-
Tender Value
INR 49 Lakhs /-

BOQ Items

Name of Work:ADDITION/ ALTERATIONTO CIVIL AND ELECTRICAL WORKS FORBUILDING NO P-128 AND P-03 AT DRDO TOWNSHIP, KANCHANBAGH, HYDERABAD.
Sl. No. Item Description
1Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.
2Demolishing brick work in cement mortarmanually / by mechanical means includng stacking of serviceable materials and disposal of unserviceable materials within 50 meter leads as per direction of Engr -in- Charge.
3Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
4M&L random rubble masonry with hard stone in superstructure above plinth level and upto floor five level, including leveling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) at window sills, ceiling level and the like. Cement mortar 1:6 (1 cement : 6 coarse sand)
5Demolishing cement concrete manually / by mechanical means including disposal of materials within 50 metres as per direction of Engr -in- Charge
6Dismantling tiles work in floors and roof laid in cement mortar including stacking materials within 50 metres lead. (i)for thickness of tiles 8mm to 25mm
7Taking out doors, windows and clerestory window shutters ( steel or wood) including stacking within 50 metres lead :- (i) of area 3 Sqm and below
8Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster includng disposal of rubbish to the dumping ground within 50 metres lead
9Taking down existing roof treatment of any position with bituminous felt including plaster / loose concrete and removing rubbish to a distance exceeding 100 mtr and not exc 250 mtrs and roughing the surface of old concrete by picking, scraping, cleaning and washing down with water to remove all dust etc all as specified and directed.
10M&L cement concrete 1:2:4 ( 1 cement ; 2 coarse sand : 4 Graded stone aggregte 40mm nominal size ) in pavements, laid in required slope and camber in panels as required incluidng consolidation finishng and tamping complete.
11M&L for rendering 10mm in CM 1:3overconcrete surfaces on RCC roof slab and parapets mixed with WPC @ 3% by weight of cement shall be carried out complete all as specified and directed by Engr-in-Charge. Note : WPC will be measured under separate item of this schedule.
12Supply onlyintegral water proofingcompound Make :- SCOTT AQUA PROF / IMPERMO/SIKA/FOSROC
13Providing and carry out water proofing treatment to sound, moisture free concrete surface system includes proper surface preparation to remove loose dust, dirt, loose mortar , curing compound etc carry out cementitious injectiongrouting at leakage points and construction joints using cement slurry modified with Cebex 100 plasticised expandive ground admixture supplies in 225 gm pouch,treatment of construction joints using polymer modified mortar prepare by using Nitobond SBR latects, application of polymer modified batta at floor, wall junction, filling of annular space around rain water outlet using conbextra GP2 non shrink cementoinous grouts. Andulated surface and pot hole shall be treated with epoxy mortar or putty to obtained sound/ levelled surface. Application of primer Nito proof WB primer on sound mortar slab surface. Followed by application of coat of Nito proof 600 PF liquid applied single component pitch free polyurithane coating supplied in 25 kg drum coverage @ 2.30 Kg/ m2 to achieve 1.5mm thickness in two coats complete incluidng all tools and tackles as per manufacturers specifcation. Coating shall be having crack bridging of 2mm, elongation ( ASTMD 124 ) greater than 600 percentage, tensile strength ( ASTM D412) , 2.5 N/MM2 , recovery from elongation ( ASTM D412) , 95 percentage, 85 percentage of solid contantents, tear resistance ( ASTM D624) , 15 KN/M, shore A hardness ( ASTM D2240) , 60, water vapour transimission not more than 1 gm / M2 ,water permeability ( DIN -1048) - NIL, services tempreature - 40"c to 70 dgree "c , flash point greater than 70"C HSE Guidelines :- It is recommanded to provide adequate general and local exhust ventilations, providing protection to Eye, face, Handand other skin by wearing appropriate glouse, google, face cilid, respiratory protectionetc. directed in SDS of the product.
14Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / appropriate Z sections and other sections of approved make conforming to IS : 733 and IS : 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions i.e at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium section shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling CP brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engr -in- Charge. (Glazing, paneling and dash fasteners to be paid for separately):- (i)For fixed portion powder coated aluminium ( minimum thickness of powder coating 50 micron)
15Providing and fixing anodised aluminium grill ( anodised transparent or dyed to required shade according to IS : 1868 with minimum anodic coating of grade AC 15) of approved design / pattern with approved standard section and fixed to the existing windows frame with CP barss / stainless steel screws @ 200mm centre to centre incluidng cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening all complete as per direction of Engr -in- Charge
16Proving and fixing glazing in aluminium door, window, ventilator shutters and partitions etc with EPDM rubber / neoprene gasket etc complete as per the architectural drawings and as per the directions of Enginer-in-charge:- (i)With float glass panes of 5mm thickness ( weight not less than 12.50 Kg/ Sqm)
17Supply and fix fly proof stainless steel grade 304 wire gauge with 0.5 mm dia. wire and 1.4mm wide aperture with matching to aluminium window.
18Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door Frames/Chowkhat of frame size frame size 65 x 100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (woodpowder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge),minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge.
19Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter 35 mm thick, of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate andnatural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimumcompressive strength50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread offlame of Class Acategory with property of being termite/ borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. Note: Stainless steel butt hinges and necessary S.S screws shall be paid separately.
20Providing and fixing ISI marked MS pressed butt hinges 100 x 58 x 1.90mm bright finished with necessary screws etc complete
21Providing and fixing IS : 12817 marked stainless steel butt hinges of size 75x47x1.80 mm with stainless steel screws etc. complete :
22Providing and fixing aluminium handles 125mm , ISI marked , anodised ( anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc complete
23Providing and fixing aluminium tower bolts 150 x 10mm, ISI marked, anodised ( anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc complete
24Providing and fixing aluminium sliding door bolts 300 x 16mm , ISI marked anodised ( anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nut and screws etc complete
25Providing and fixing aluminium Twin rubber stopper hanging floor door stopper, ISI marked, anodised ( anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade , with necessary screws complete
26Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size)
27M&L painting to steel surface with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade two coats of old surfaces complete.
28Providing and fixing factory made door frame ( single rebate ) made out of single piece extruded solid PVC foam profile with homogenous fine cellular structure having smooth outer integral skin having 62mm width & 32mm thickness , frame will be mitred & jointed with self driven self tapping screws of size 38mm x 4mm & PVC solvent cement including fixing the frame to wall with suitable dia & length anchor fastener as per manufacturer"s specification and direction of Engineer -in- Charge.
29Providing and fixing factory made 30mm thick door shutter made of solid PVC fooam profile. The styles & rails shall be of size 75mm x 30mm having wall thickness 5mm. The styles, top & bottom rails shall have one side wall thickness of 15mm integrally extruded on the hinge side of the profile for better screw holding power. The styles and rails shall be reinforced with MS tubes of size 33mm x 17mm x 1mm, painted with primer, all four corners of reinforcement to be welded or sealed. solid PVC extruded bidding ( push fit type) will be set inside the styles and the rails with a cavity, to receive single piece extruded 5mmPVC sheet as panel. The styles and rails will be mitred cut and joint with help of PVC solvent cement & self driven self tapping screws. Single piece extruded solid PVC lock rail of size 100mm x 30mm with wall thickness 5mm & 15mm integrally extruded in the middle of the lock rail & fixed with styles with the help of PVC solvent cement & self driven self tapping screws of size 100mm x 8mm complete as per manufacturer"s specifications and direction of Engineer -in- Charge. (i)Decorative finish( both side wood grained finish)
30Material and labour for15mm thick rendering in CM 1:6 on fair faces of brick work or concrete surfaces and finished the surface fair and even without using extra cement complete .
31M&L 6mm thick cement plaster 1:3 ( 1 cement : 3 fine sand) on ceiling surface finished with a floating coat of neat cement and thick coat of lime wash on top of ceiling when dry for bearing of RCC slabs and beams
32M&L for Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) :Raised and cut pointing
33M&L Finishing wall New work ( Two or more coats applied @ 1.43 litre/ 10 Sqm over and including priming coat of exterior primer applied @ 0.90 litre / 10 Sqm with 100 % premium acrylic emulsion paint having VOC less than 50 gm/ litre and UV resistance as per IS 15489 :2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade ( Company Depot tinted ) with silicon additives
34M&L Distempring Two or more coats on new workover a coat wall primer with Ist quality acrylic distemper , having VOC ( Volatile Organic Compound) content less than 50 grams / litre of approved brand and manufacture of required shade and colour including applying 1mm thick wall care puttycomplete as per manufacturer"s specification
35M&L White washing on new work of ceiling surfaces(three or more coats)to give an even shade complete
36Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete and Distempering on old work ( wall/ ceiling) twowith 1st qualityacrylic distember ( Ready mix ) having VOC content less than 50 grams/ litre of approved brand over a coat of water thinnable cement primerand manufacturer to give an even shade
37M&L Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade Old work (Two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface and Removingwater proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
38M&L White washing on old surface and removing of old white washon ceiling surfaces Old work (two or more coats) sqmto give an even shade complete
39M&L Painting on new steel surface ( two or more coats ) incluidng a coat of approved steel primer ( red oxide primer)with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade
40Providing and laying Double chargevitrified tiles size 600 x 600mm in floor in different size ( tbhickness to be specified by the manufacturer ) with water absorption less than 0.08 % and conforming to IS : 15622 of approved brand & manufacturer, in all colours and shade , laid on 20mm thick cement mortar 1:4 jointing with grey cement slurry @ 3.3 kg/Sqm incluidng grouting the joints with white cement and matching pigments etc. the tiles must be cut with the zero chipping diamond cutter only. Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, levelling system and rubber mallet for placing the tiles gently and easily.
41Providing and laying vitrified tiles in different sizes ( size of tiles 600 x 600 mm) ( thickness to be specified by manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours & shade , in skirting, riser of steps , over 12mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand), jointing with grey cement slurry @ 3.3 Kg / Sqm including grouting the joint with white cement & matching pigments etc complete
42Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 ( thickness to be specified by the manufacturer) of approved make, in all colours, shades except burgundy, bottle green, black of and size as approved by Engr -in- charge , in skirting, risers of steps and dados, over 12mm thick bed of cement mortar 1:3 ( 1 cement ; 3 coarse sand) and jointing with grey cement slurry @ 3.3 Kg per sqm, incluidng pointing in white cement mixed with pigment of matching shade complete
43Providing and laying ceramic glazed floor tiles of size 300 x 300 mm or more( thickness to be specified by the manufacturer) of !st quality conforming to IS : 15622 of approved make in colours and shade exceptwhite ivory, Grey, fume Red Brown, laid on 20mm thick cement mortar 1:4 ( 1 cement : 4 Coarse sand) , jointing with grey cement slurry @ 3.3 Kg/ Sqm incluidng pointing the joints with white cement and matching pigment etc complete
44M&L brick work with common burnt clay F.P.S ( non modular ) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in cement mortar 1:4 complete
45Disconnecting damaged over head / terrace PVC water storage tank of any size from water supply line and removing from the terrace incluidng shifting at ground level as per direction of Engr -in- Charge
46Providing and placing on terrace ( at all floor leels) polyethylene water storage tank, 1000 ltr capacity Is: 12701 marked , with cover and suitable locking arrangements and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
47Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes15 mm nominal dia , having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc and dismantling 15 to 40 mm dia G.I. pipe including stacking of dismantled pipes (within 50 metres lead) as per direction of Engineerin-Charge and Concealed work, including cutting chases and making good the walls etc.
48Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes20 mm nominal dia , having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. Exposed on wall,This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. and Dismantling 15 to 40 mm dia G.I. pipe including stacking of dismantled pipes (within 50 metres lead) as per direction of Engineer-in-Charge.
49Providing and fixing in repair gun metal gate valve 20mm nominal bore with CI wheel of approved quality ( screwed end) complete
50Dismantling CI, plastic or asbestos rain water pipe with fittigns and clamps incluindg stacking the materials within 50 metres lead :- (i) 100mm dia pipe
51Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type "A" including jointing with seal ring conforming to IS : 5382, leaving 10mm gap for thermal expansion single socketed pipes :- (ii) 110 mm diameter
52Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type "A" incluidng jointing with seal ring conforming to IS : 5382, leaving 10mm gap for thermal expansion :- (i)Bend 110mm dia
53All as per item No.52 above but Couple 110mm dia
54Providing and fixng PTMT ball cock of approved quality , colour and make complete with Epoxy coated aluminium rod with LP / HP HD platic ball :- (i)20mm nominal bore 120mm long , weighing not less than 198 gms
55Providing and fixing in repair C.P. brass stop cock (concealed) of 15 mm nominal bore, standard design and of approved make conforming to IS:8931,
56Providing and fixing in repairs C.P. brass shower rose with 15 or 20 mm inlet : 100 mm diameter
57Providing and laying cement concrete in retaining walls, return walls ( any thickness) incluidng attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, sunken floors etc upto floor five level excluding the cost of centering shuttering and finishing :- (i)1:2:4(1 cement : 2 coarse sand ( zone -III) derived from natural sources : 4 graded stone aggregate 20mm nominal size derived from natural sources )
58Providing and fixingsteel E165 (Fe 290) confirming to IS 2062 -2006 workin gratings, frames, guard bars, ladders, railing, brackets, purlings, gates and similar workswelded in built up sections / frames work, incluidng cutting, hoisting, fixing in position and applying priming coat of approved steel primer using structural steel as required
59Making the opening in brick masonry for door/ window/ clerestory vantilator forexhaust fan window including dismantling in floor or walls by cutting masonry and making good the damages to walls, flooring and jambs complete to match existing surface i/c disposal of mulba / rubbish to the nearest municipal dumping ground, all complete as per direction of Engineer -in-Charge
60M&L for preparation of surfaces of cracks in walls and ceilings land filling smart crack filler to any depth while surfaces are dry and sealing cracks completely and flushing with existing surfaces all as per manufacturers instruction. Make : Asian Paints smart cracks filler or equivalent in Dr fixit
61Providing and fixingin repair 100 mm inlet and 75 mm outlet dia sand cast iron S&Strap of self cleansing design with screwed down or hinged grating with or without vent arm complete incluindg cost of cutting and making good the walls and floors
62Providing and fixing in repairs square mouth S.W gully trap class SP-1 complete with C.I grating brick masonry chamber with water tight C.I cover with frame of 300 x 300 mm size ( inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design :- (i)150 x 100 mm size P type with common burnt clay F.P.S ( non modular) bricks of class designation 7.5
63Providing and fixingin repais wash basin with CI brackets, 15mm CP brass pillar taps, 32mm CP brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required :- (i)White vitreous china flat back wash basin size 550 x 400mm with single 15mm CP brass pillar tap
64Providing and fixing PVC waste pipe flexible pipe 32mm / 40mm diafor sink or wash basin and urinal incluindg PVC waste fittings complete
65Providing and fixing600 x 450 mm beveled edge mirror of superior glass ( of approved quality complete with 6mm thick hard board ground fixed to wooden cleats with CP brass screws and washers complete
66Providing and fixing in repairsCP brass long nose bib cock 15mm nominal bore of approved quality conforming to IS standards and weighing not less 410 gms
67Providing and fixing in repairs CP brass angle valves 15mm nominal bore for basin, mixed, geyser, urinal etc points of approved quality conforming to IS 8931
68Providing and fixing uplasticised PVC connection 15mm nominal bore x 45 cm length pipe with PTMT nuts, collar and bush of approved and colour
69Excavation work by mechanical means ( Hydraulic excavator ) / manual means in foundation trenches or drains ( not exceeding 1.5m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5m, includig getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 m:- (i)Ordfinary rock
70Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms in bathroom all complete.
71Providing and laying cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing,
72Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangements of approved quality and colour 600mm long
73Disposal of building rubbish / malba/ similar unserviceable, dismantled or waste materials by mechanical means, incluidng loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer -in- charge beyond 50m initial lead for all leads incluidng all lifts involved.
74Returning filling in trenches incl spreading,levelling , watering&well ramming in layers n.exc 25 CM thick
75Providing and fixing in repairwater closet squatting pan ( Indian type WC pan) with 100mm sand cast iron P or S trap, 10 litre low level white PVC flushing cistern including flush pipe, with manually controlled device ( handle lever) conforming to IS : 7231, with all fittings and fixtures complete includng cutting and making good the walls and floors wherever required :- (i) white vitreous china orrissa pattern WC, pan of size 580 x 440 mm with integral type foot rests
76Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with white solid plastic seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including Dismantling and disposal of dismantled materials i/c malba,cutting and making good the walls and floors wherever required :
77Making plinth protection 50mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sandderived from natural sources : 6 graded stone aggregate 20mm nominall size derived from natural sources) of 75mm thick bed of dry brick ballast 40mm nominal size, well rammed and consolidated and grouted with fine sand , including necessary excavation, levelling & dressing & finishing the top smooth.
78Providing and fixing to 125 mm grating with waste hole
79Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : (a) 75 to 80 mm dia pipe
80Providing and fixing on wall face unplasticised Rigid PVC 75 mm diameterwater pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
81Providing and fixing Coupler 75 mm
82Providing and fixing Single tee with door75x75x75 mm
83Providing and fixing Bend 87.5° of75 mm bend each
84Providing and fixing soil, waste and vent pipes :100 mm dia, sand cast iron S&S pipe as per IS: 1729
85Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required :Size 600x450x200 mm
86Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge.
87Providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595mm of approved texture, design andpatterns as perSpecification , to be laid in true horizontal level suspended on inter-locking metalT-Grid of hot dipped galvanised iron section of 0.33mmthick(galvanized@120gramspersqm includingbothsides)comprising ofmain-Trunners of size 24x38 mm of length 3000 mm,cross-Tofsize24x32mmoflength 1200mmandsecondaryintermediate cross-Tof size 24x32 mm of length 600mm to formgrid module of size 600 x 600 mm, suspended from ceiling usinggalvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 12x50 mm long dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 76x25x25x1.6 mm fixed with grid and Z cleat of size 25x37x25x1.6mm thick with precut hole on both 25mm flange to pierce into 12x50mm or even bigger size dash fastener if require, fixed with Glavanised iron perimeter wall angle or size 24x24x0.40 mm of length 3000 mm to be fixed on periphey wall / partition with the help of plastic rawl plugs at 450mm center to center and 40 mm long dry wall S.S screws. The workshall be carried out as per specifications, drawing and as per directionsof the Engineer-inCharge.With 15 mm thick tegular/butt edged without perforation plain/designer light weight calcium silicate Anti-Microbial Bio-Safe coated false ceiling tiles Confirming to JIS-Z2801 and ASTM G-21
88M&L Steel reinforcement for RCC workready to use "cut and bend" and welding rebars of approved make from factory / workshop to construction site including placing in position and binding all complete above plinth level upto 3rd floor roof slab projection and welding where is necessary. (i)Thermo / Mechanically Treated bars of grade Fe- 500D or more
89M&L for followings :- (i) Removing plaster, loose concrete & finishes all around the coloumns, slabs & beams (on all four sidescription of column to full height , three sidescription of beam to entire span & bottom of slab to area as directed) (ii) After cleaning gently removing cover concrete using pneumatic/electric chipper or any other approved tool in entire portion of structural member (removal of cover concrete shall be done to an extent when reinforcement is visible) (iii) Removal of cover concrete with under cutting of up to a depth of 20mm beyond reinforcement around full circumference & full length of bar where directed. (concrete shall be stripped to an extent concrete substrate is exposed) (iv) Removing visible rust along the length of reinforcement using hand tools as approved. (The Engr-in-charge may order sand blasting if rust is approved) (v) Any other work as directed by Engr-in-charge to present clean surface for determination of type of repair to be carried out complete all as specified and directed.
90M&L for Providing & Pouring Micro concreting M-40 grade :- Immediately after application of epoxy bond coat as above pour Micro concreting M40 grade, Make : MasterEmaco S46T of BASF or equivalent FOSROC/SIKA using approved mixing machines/pumping under pressure via approved pneumatic pump at the locations to be repaired in RCC beams & columns etc,. Adding of aggregates will be permitted only as per manufacturer’s recommendation without compromising the strength. The rate shall include cost of all materials (except re-bar) labour charges for mixing, pouring concrete, cost of tools, lead & lift of materials, transportation etc., to carry out the complete work complete all as specified and directed. Note : The cost of micro concrete M-40 grade & Epoxy bond coat is inclueded in this item.
91M&L for use & waste of form work using steel sheets , steel bracing, propping etc around structural members where micro concreting to be done and keeping form work in position till required specified period complete all as specified and directed. Note :Form work shall be 100% leak proof. For purpose of payment area in touch with concrete shall be measured.
92M&L for providing rust proof /anti corrosive treatment to bars :- (i) cleaning of all exposed bars (new & old) alround (ii) Apply a single coat of Alkaline rust converting primer on alround bars new & old as recommended by the manufactuer (iii) Apply two coats of Epoxy phenolic anti corrosive protective coat on bars alround new & old as recommended by the manufactuer. Note : Anti corrosive treatment shall be continuous espcially in the regions where pitting, imperfections, etc were present on the surface of the bars. It is important that the rear portions of re bars (those towards the concrete substrate) should not be left without coating.
93M&L for providing PMM (Polymer modified cementitious mortar) :- (i) Dry sub strate surface and free of debris & dust (ii) Applying Epoxy bond coat on the sound substrate using approved spray machine & ensuring that no pin holes are visible.(In case pin holes are still visible after a coat, a second coat shall be applied to ensure absence of pin holes). (iii) Immediately after application of epoxy bond coat as above apply PMM (Polymer modified cementitious mortar) of 25 mm thickness. Note :Application of PMM shall be preferably be in coats of appx 10mm thickness. PMM work shall be executed in fairely rapid successions so as entire work is completed with in 30 mins). PMM shall be pre packed ready to use. (iv) PMM surface to be moist cured for three days followed by air curing in temperature as recommended by manufactuer complete all as specified and directed.
94Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
95Dismantling wooden boardings in lining of walls and partitions, supporting members but including stacking within 50 metres lead, refixing same place, Thickness of members 10 mm up to 25 mm
96Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc.
97M&L for point wiring complete with 1.5 Sqmm PVC insuulated unsheathe multistranded FRLS copper conductor 1100 V grade drawn throught and including 20 mm dia PVC conduit, medium grade and conduit accessories, concealed in the walls/ceiling and terminated to sunken metal box of modular type and including provision of GI modular box ISI marked in the walls suitable switches,sockets etc.,and including modular white lates for fixing modular switches,sockets/regulators etc., including 1.5 sqmm PVC insulated unsheathed multi-stranded FRLS copper conductor cable as earth continuity conductor and connecting to common earth dolly with brass screws, washers, copper lugs etc., complete all as specified and directed for one light . fan point /bell point/ bell point/ceiling fan / exhaust point controlled by one , one -way switch 5 Amps .
98All as per SL item No.98 here-in- beforeOne3 pin 5/6 Amps socket outlet point on independent board controlled by one one way 5/6 Amp switch, complete.
99All as per SL item No.98 here-in- before but controlled by two two way6 Amps switces complete
100All as per SL item No.98 here-in- before but forOne 3 pin socket outlet 5/6 Amps socket outlet point on same board controlled by one one-way 5/6 Amps switch, complete.
101M&L for point wiring complete with 4.0 Sqmm PVC insuulated unsheathe multistranded FRLS copper conductor 1100 V grade drawn throught and including 20 mm dia PVC conduit, medium grade and conduit accessories, concealed in the walls/ceiling and terminated to sunken metal box of modular type and including provision of GI modular box ISI marked in the walls suitable switches,sockets etc.,and including modular white lates for fixing modular switches,sockets/regulators etc., including 4.0 sqmm PVC insulated unsheathed multi-stranded FRLS copper conductor cable as earth continuity conductor and connecting to common earth dolly with brass screws, washers, copper lugs etc., complete all as specified and directed for 3-pin15/16 Amp socket outlet point t board, complete.
102Supply & Fixing Modular switch, one module, one way 6 Amp, 230V, complete all as specified and directed.
103Supply & Fixing Modular switch 16A, one module, 230 Volts, complete all as specified and directed.
104S&F modular switchtwoway 6 amps 1 module ,230V complete all as specified and directed.
105Supply & Fixing Modular step type, fan regulator, two module, 230 Volts, complete all as specified and directed.
106Supply & Fixing socket out let 6 Amps, 230 volts AC 3 pin multipurpose type complete as directed.
107Supply & Fixing modular socket, 6A/16A - 230V Multipurpose complete
108S&FModular Bell push6 Ampsone module
109S&F ceiling rose two to three terminal surface backallite type AC 50Hz 230 volts complete
110M&L for bell electric AC. 230 V fish type, calling bell including taking down old unserviceable one complete
111S&F LED lights fittings 1x20W,220V,AC decorative box type with driver holder including LED tube light connecting up with three coreflexible copper conductor cable of suitable size from ceiling rose complete,including connecting up with twin core flexible copper conductor cable with sutable size
112S&F LED light fitting mirror type with high out put diffuser 2 feet, 10 Watt 220 V AC decorative type with driver holderand LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete.
113Supply & Fix LEDstreetlight fitting 30 W 230 V AC outdooor type with high pressure die cast alumiium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP/65/66 protection complete.
114S&F LED luminaire 600mm x600 mm 35/36 W, 220V AC recessed/surface mounted type with highefficiency PMMA diffuser soft glare light with LED efficacy of 120 lm/Watt electronic driver, suitable for roof ceiling including connecting up with driver three core copper conductor 1.5 Sqmm size complete.
115Supply and fixing 240V, 10 KA "B" curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning.
116Supply and fixing amp rating 240V, 10KA "C" curve miniature circuit breaker (MCB) of 2 poles and current carrying capacity up to 40AMP, in the MCB DB complete with connection testing and commissioning.
117Supply and fix 415 V 10 KA "C" curve miniature circuit break (MCB)of TPN 40-100 amps current carrying capacity in the DB complete with connection testing and commissioning
118S&F sheet metal enclosure MCCB DB VTPN double door type AC 415 V 4 way with 200 Amps rated bus bar, vertical type with MCCB 100 A 4 pole 16 KA as in comer flush to wall & outgoing MCB"s/isolators including taking down old one complete and making good of distructed surface including taking down old one complete
119S&F sheet metal enclosure MCCB DB TPN double door type AC 415 V 4 way with 200 Amps rated bus bar, vertical type with MCCB 63 A 4 pole 10 KA as in comer flush to wallincluding taking down old one complete and making good of distructed surface including taking down old one complete
120Supplying and fixing 12 way single pole and neutral, sheet steel MCB districution boad, 240 V, on surface/recess,complete with tinned copper bus bar neutral bus bar earth bar, din bar inter connections, powder painted including earthing etc. as required.
121M&L for sub main wiring complete with 4 runs of 6 sqmm PVC insulated heavy duty and unsheathed cable with multistranded copper conductor and drawing through in and including PVC conduitof suitable size and connecting terminal ends to meters and DB"s incluidng provision of 2 run of 6 Sqmm insulated copper cable for earth continuity conductor and connecting to earth dolly an dtaking down old u/s one complete.
122M&L for sub main wiring complete with 4 runs of 4 sqmm PVC insulated heavy duty and unsheathed cable with multistranded copper conductor and drawing through in and including PVC conduitof suitable size and connecting terminal ends to meters and DB"s incluidng provision of 2 run of 4 Sqmm insulated copper cable for earth continuity conductor and connecting to earth dolly and taking down old u/s one complete.
123M&L for sub main wiring complete with 2 runs of 4 sqmm PVC insulated heavy duty and unsheathed cable with multistranded copper conductor and drawing through in and including PVC conduitof suitable size and connecting terminal ends to meters and DB"s incluidng provision of 1 run of 4 Sqmm insulated copper cable for earth continuity conductor and connecting to earth dolly and taking down old u/s one complete.
124Taking down ceiling fan/exhaust fan /wallmounting fan of any make, sewwp and dismantling, cleaning , and painting the same with one or more coats of spray painting with synthetic enamel paint of approved brand and manufacture to give an eben shade, including cleaning of surface with detergent and replacing the damaged rubber reel, nuts and bolts with eashers and safety pins reinstalling the same as required. complete.
125S&F Metal clad AC earth plug and socket with sheet metalenclosure with MCB Sp20 A complete
126S&F Rigid non metallic PVC conduit, 20 mm external dia, exclusive of boxes (junctons/terminal) but inclusive of all tees, bends, elbowa, reducers, bell mouth tube ends and fixing accessories such as couplers, locknut,saddles,pipe hooks etc, complete
127Supplying and drawing co-axial TV cable RG-6 grade,0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/recessed steel/ PVC conduit as required.
128Taking down carfully existing serviceable split type AC/window AC unit of 1.5/2.0TR capacity and refixing in another location in any positionand height complete with all conneccted work like making opening, fixing mounting brackets and all other required accessories including making good the distrubed surfaces complete all as directed.
129Supply & fix wall mounted fan of capacity 400 mm sweep complete all as directed.
130Supply & fix exhaust fan of 230 mm sweep complete all as directed
131Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply earthing complete all as directed.
132Earthing complete with GI earth plate electrode 600x600x6mm buried directly in ground vertically to a depth of not less than 2.25 mtr belowground level than 1.5 mtr below ground level connected to GI earth wire 4 mm dia by means of bolts washers etc made out of GI earth wire will be protected by galvanized iron pipe light grade 15 mm bore up to main distribution board/main switch including necessary excavation and earth work PCC 1:3:6 type CI (using 20 mm graded stone aggregate) RCC cover 1:2:4 type B1 including necessary reinforcement etc complete all as show electric plate No. 3 ofMES suchpart-I complete
133Earth continuity conductor or main earthing lead fixed to fixed to wall or batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required Gi wire 4 mm as earthing lead.
134Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 corethe cable to be laied on the wall and proper aligement, clamping and termination is to be done on the qouated rate all as directed by Engineer-in-Charge.
135Supply and lay GI tubing medium grade with fittings such as tees, beand, union elbow, nipple, collor, sockets, reducer, clamps etc, fixed in wall ceiling, laid in trenches etc all as specified and directed for the following sizes.
13640 mm dia
13725 mm dia
13820 mm dia
13915 mm dia
140Supply and fix 40 mm gun- metal,globe or gate valves,with iron wheel head screwed both ends for iron pipe and fixed etc all as directed.
141Supply and fix 25 mm gun- metal,globe or gate valves,with iron wheel head screwed both ends for iron pipe and fixed etc all as directed.
142Supply and fix 20 mm gun- metal,globe or gate valves,with iron wheel head screwed both ends for iron pipe and fixed etc all as directed.