| 1 | SH:- I (Maintenance & Operation)(For Social Welfare building - Asha Deep at Narela, FRRO & Sewa Sadan at Lampur, Fire Station at Bhorgarh, Narela, Bawana)Providing servicesfordaytoday running operation&maintenanceofallelectricalinstallations and all type wiring as per inventory attached on all days including Sunday and holidays etc. as required. |
| 2 | SH:- II (EI Work)Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.a) Group C |
| 3 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.a) Group C |
| 4 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.a) Group C |
| 5 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.a) 25 mm dia |
| 6 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.a) 1 or 2 Module (75 mmX75 mm) |
| 7 | b) 3 Module (100 mmX75 mm) |
| 8 | c) 4 Module (125 mmX75 mm) |
| 9 | d) 6 Module (200 mmX75 mm) |
| 10 | e) 8 Module (125 mmX125 mm) |
| 11 | f) 12 Module (200 mmX150 mm) |
| 12 | Supplying and fixing metal box of 150 mm X 75 mm X 60 mmdeep(nominalsize)onsurfaceorinrecesswith suitablesizeofphenoliclaminatedsheetcoverinfront includingprovidingandfixing3pin5/6Asocketoutlet and 5/6 A piano type switch, connections, painting etc. as required. |
| 13 | Supplying and fixing metal box of 180 mm X 100 mm X 60mmdeep(nominalsize)onsurfaceorinrecesswith suitablesizeofphenoliclaminatedsheetcoverinfront includingprovidingandfixing6pin5/6A&15/16A socket outlet and 15/16 A piano type switch, connections, painting etc. as required. |
| 14 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 15 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 16 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, “C” curve including connections, painting etc. as required. |
| 17 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)a) 12 way, Double door |
| 18 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator)a) 4 way (4 + 12), Double door |
| 19 | Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 20 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 21 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 22 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. . |
| 23 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing RCC/ HUME/ METAL pipe as required.a) Upto 35 sq. mm |
| 24 | b) Above 35 sq. mm and upto 95 sq. mm |
| 25 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on wall surface as required.a) Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 26 | b) above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) |
| 27 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as requireda) 3½ X 35 sq. mm (32mm) |
| 28 | b) 3½ X 70 sq. mm (38mm) |
| 29 | c) 4 X 25 sq. mm (28mm) |
| 30 | Supplying and making straight through joint with cast resin compound including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPEaluminium conductor cable of 1.1 kV grade as requireda)3½ X 35 sq. mm |
| 31 | b) 3.5X70 Sq mm |
| 32 | Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and re-filling etc. as required.a) 100 mm dia |
| 33 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.a) 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 34 | Providing , laying , testing & commissioning of \"B\" class medium duty G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required.a) 65 mm |
| 35 | b) 80 mm |
| 36 | Supplying and fixing of following electrical accessories in the existingcubical panel , DBs feeder pillar including connection, inter connection with suitablesize connector complete etc as required.a) Three phase LED Ammeter (class 1) withselector switch and CThaving ration 50/5 A |
| 37 | b) Three phase LED Voltmeter (class 1) with selector Switch |
| 38 | c)1 Module Red-Yellow-Blue Indicating Lights |
| 39 | d)Digital timer |
| 40 | e) 70 amp 3Phase Contactor (MNX 70) |
| 41 | Provision for pole / wall mounted box (300X200x105) mm size made out of (SMC) sheet moulding compound dust & wheather proof with front openable hinged type cover with locking arrangement i/c providing and fixing of following accessories on existing pole / wall with suitable arrangement as required:a) 32 amp 5 way connector with bakelite baseb) 6 amp SP MCB \"C\" curve (10 KA )- 1 No.c) Earth stud - 2 setsd) 40 x 5 clamp with 2 nos 3/8\" Nuts & Bolts - 1 set as required.e) push and clip handle to close/open- 1no |
| 42 | Rewinding of 1200/1400 mmceiling fan with super enameled copper wire including inspection of fan suspension arrangement and tightness of nuts and bolts, cotter pin, rubber reel and replacement of the same wherever found defective during inspection for safe running of fan i/c cleaning the fan with detergent i/c less for old dismantlecomplete etc as required. |
| 43 | Rewinding of 300/380 mmexhaust fan including inspection of fan fixing arrangement and tightness of nuts and boltsi/c cleaning the fan with detergent i/c less for old dismantle complete etc as required. |
| 44 | Repairing of all type of damage pumps (of water supply/sewage etc. pump sets) i/c dismantling from site, shifting to workshop, turning & polishing of shaft, replacement of GM bearing bush, ball bearing, O ring, thrust bush, thrust plate etc. all items/parts i/c buy back of dismantle material to contractor (dismantle material shall retained with agency) i/c transfer from workshop to site of work including reassembled, installation, testing and commissioning etc complete as required at site.a) 3 HP pump motor sets (all types) |
| 45 | b) 5 HP pump motor sets (all types) |
| 46 | c) 7.5/10 HP pump motor sets (all types) |
| 47 | Dismantling of existing motor pump sets, transfer to workshop from site, rewinding ofMotor with super enamelled copper wire including inspection of motor suspension arrangement and tightness of nuts and bolts, cotter pin, rubber reel and replacement of the same wherever found defective during inspection for safe running of motor i/c cleaning the motor with detergent i/c less for old dismantle complete etc as required including reassemble, transfer to site of work including installation, testing and commissioning etc. complete as required at site.a) 3 HP pump motor sets (all types) |
| 48 | b) 5 HP pump motor sets (all types) |
| 49 | c) 7.5/10 HP pump motor sets (all types) |
| 50 | Liftingof existing submersible bore well / open well Pump set from the bore well with chain pulley block & tripod stand i/c cartage charge at site from the work shop. |
| 51 | Lowering of bore well/open well pumpset in the bore well with chain pulley block and tripod stand i/c cartage charge pump set from work shop to site credit of old dismantle etc, as reqd. |
| 52 | Supplying, Lowering of G.I Pipe 50mm dia medium class havinglengthof3mtr.Eachlengthhaving threadingon bothendsi/c2nosflangesweldedateachends,gasket, nut, bolts etc complete as reqd. |
| 53 | Supply, Installation, Testing and Commissioning of following capacity water heater (Geyser) complete 8 bar pressure i/c making connection of water inlet and out let connection (with firm`s supply accessories) i.e. Fastners, Flexible PVC Connection, Plug Top etc.) a) 25 Ltr. (5 Star Rated) |
| 54 | Supplying& fixing of following sq.mmflatwaterproof copperconductorsubmersiblecablei/cwaterproofjoint,connection for submersible pumpset etc. complete as reqd.a) 3core 4 sq.mm |
| 55 | b) 3core 6 sq.mm |
| 56 | SITC of DOL Starter suitable upto6 HPSubmersible Pump having relay range 6-10 A suitable for 180-415V 50Hz, 3 phase motor complete with sheet enclosure, start stop push button, on off LED indication lamp and all other accessories including connections & testing etc complete as required. |
| 57 | SH:- III(Supply of material)Supply of following materials :- a) S.P. 5/6 A, one way modular switch, ISI marked |
| 58 | b) S.P. 15/16 A, one way modular switch, ISI marked |
| 59 | c) 3 pin 5/6 A modular socket outlet, ISI marked |
| 60 | d) 6 pin 15/16 A modular socket outlet, ISI marked |
| 61 | e) Stepped type Modular Fan regulator (2 module) |
| 62 | f) 6 A, to 32 A, ratings, SP MCB, \"C\" curve, 10 KA breaking capacity |
| 63 | g) 100 A, 16 kA,TPMCCB |
| 64 | h) 125 A, 16 kA,TPMCCB |
| 65 | i) 150 A, 16 kA,TPMCCB |
| 66 | j) 200 A, 16 kA,TPMCCB |
| 67 | k) 63 A, 10kA, SPN MCB (240 V) |
| 68 | l) 63 A, 10kA, TPMCB (415 V) |
| 69 | m) 63 A, 10kA, TPN MCB (415 V) |
| 70 | n) Ceiling rose, 3 pin, 5A ISI marked |
| 71 | o) Modular base & cover plate for 1 or 2 module |
| 72 | p) Modular base & cover plate for 3 module |
| 73 | q) Modular base & cover plate for 4 module |
| 74 | r) Modular base & cover plate for 6 module |
| 75 | s) Modular base & cover plate for 8 module |
| 76 | t) Modular base & cover plate for 12 module |
| 77 | u) 3 mm thick phenolic laminated sheet |
| 78 | v) 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor with remote or electronic regulator etc. complete as required. |
| 79 | w) Heavy duty metal exhaust fan of 300 mm sweep 900 rpm etc. complete as reqd. |
| 80 | x) Heavy duty metal exhaust fan of 380 mm sweep 1400 rpm etc, complete as reqd. |
| 81 | SH:- IV (Credit of old dismantle material)Less credit for Old dismantle of following items:-a) Ceiling fan(1200/1400mm sweep) |
| 82 | b) Exhaust Fan(300/380mm sweep) |
| 83 | c) All size PVC wires (Aluminium conductor) |
| 84 | d) All size PVC wires (Copperconductor) |
| 85 | e) GI Box i/c Cover Plate |
| 86 | f) 5/16 A switch and socket(Piano/Modular) |
| 87 | g) 5-32 A MCB |
| 88 | h) Regulator |
| 89 | i) 40A to 63 A DPMCB/TPMCB/Isolators |
| 90 | j) 100A to 200 A MCCB |
| 91 | k) GI Pipe (50/65/80 mm) |
| 92 | l) DOL Starter |