Tender For Annual Operation , Maintenance And Providing Civil And Electrical Maintenance (Including Facility Management Services) For Office And Residential Complexes At Bina Project For 02 Years, Sonbhadra-Uttar Pradesh

Northern Coalfields Limited-NCL has published Tender For Annual Operation , Maintenance And Providing Civil And Electrical Maintenance (Including Facility Management Services) For Office And Residential Complexes At Bina Project For 02 Years. Submission Date for this Tender is 24-04-2024. Electrical Maintenance Tenders in Sonbhadra Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

43107191
Corrigendum : Tender For Annual Operation , Maintenance And Providing Civil And Electrical Maintenance (Including Facility Management Services) For Office And Residential Complexes At Bina Project For 02 Years
Open Tender
Indian
Uttar Pradesh
Sonbhadra
24-04-2024

Tender Details

Annual Operation , Maintenance And Providing Civil And Electrical Maintenance (Including Facility Management Services) For Office And Residential Complexes At Bina Project For 02 Years As Per Nit

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 20-Apr-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 24-04-2024

Key Value

Document Fees
Refer document
EMD
INR 2065300.0 /-
Tender Value
INR 16.52 Crore /-

BOQ Items

Name of Work:Annual operation , maintenance and providing civil and electrical maintenance (including facility management services) for office and residential complexes at Bina project for 02 years
Sl. No. Item Description
1Part A Operation of water supply
2Operation of valves, pumps and supply of water in colony area as per institution of engineer incharge ( 15nos semi skilled labour engaged in one day)
3Part B Repair and maintenance of water supply in Colony
4Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
5Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge :15 mm to 40 mm nominal bore
6Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge :Above 40 mm nominal bore
7Dismantling of flushing cistern of all types (C.I./PVC/Vitrious China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead.
8Dismantling of C.I. sluice valve including stacking of useful materials within a lead of 50 metres Up to 150 mm diameter
9Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap
10Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete.10 litre capacity - White
11Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings : Flat back wash basin of size 550x400 mm
12Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.Semi rigid pipe 32 mm dia
13Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.Semi rigid pipe 40 mm dia
14Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
15Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete.
16Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. Waste coupling 31 mm dia of 79 mm length and 62mm breadth weighing not less than 45 gms
17Waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 gms
18Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms.
19Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 25 mm nominal outer dia Pipes
20Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 50 mm nominal outer dia Pipes
21Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall 25 mm dia nominal bore
22Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall 15 mm dia nominal bore
23Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall 20 mm dia nominal bore
24Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 15 mm dia nominal bore
25Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 20 mm dia nominal bore
26Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 25 mm dia nominal bore
27Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 40 mm dia nominal bore
28Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 50 mm dia nominal bore
29Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 80 mm dia nominal bore
30Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 25 to 40 mm nominal bore
31Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 50 to 80 mm nominal bore
32Providing and fixing brass stop cock of approved quality : 15 mm nominal bore
33Providing and fixing brass stop cock of approved quality : 20 mm nominal bore
34Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 25 mm nominal bore
35Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40 mm nominal bore
36Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 50 mm nominal bore
37Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 80 mm nominal bore
38Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 15 mm nominal bore
39Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 25 mm nominal bore
40Providing and fixing brass ferrule with C.I. mouth cover including boring and tapping the main :20 mm nominal bore
41Providing and fixing brass ferrule with C.I. mouth cover including boring and tapping the main :25 mm nominal bore
42Providing and fixing uplasticised PVC connection pipe with brass unions : :45 cm length 15 mm nominal bore
43Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 100 mm diameter
44Providing lead caulked joints to spun iron or C.I. pipes and specials, including testing of joints but excluding the cost of pig lead : 150 mm diameter pipe
45Providing lead caulked joints to spun iron or C.I. pipes and specials, including testing of joints but excluding the cost of pig lead : 200 mm diameter pipe
46Supplying pig lead at site of work.
47Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) : 100 mm diameter Class I
48Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) :150 mm diameter Class I
49Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work): 15 mm nominal bore
50Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work):20 mm nominal bore
51Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work):25 mm nominal bore
52Providing and placing on terrace (at all floor levels) polyethylene water storage tank, ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
53Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 15 mm nominal bore
54Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15 mm nominal bore
55Providing and fixing PTMT bib cock of approved quality and colour. 15mm nominal bore, 86 mm long, weighing not less than 88 gms
56Providing and fixing PTMT pillar cock of approved quality and colour . 15 mm nominal bore, 107 mm long, weighing not less than 110 gms
57Providing and fixing Solid plastic seat for European pan etc, all complete.
58Providing and fixing Pedestal
59Providing and fixing bolts including nuts and washers complete.
60Providing and fixing C.P angle valve
61Providing and fixing G.I. elbows of approved quality all complete as per instruction of EIC. 15 mm dia nominal bore
62Providing and fixing G.I. elbows of approved quality all complete as per instruction of EIC.20 mm dia nominal bore
63Providing and fixing G.I. elbows of approved quality all complete as per instruction of EIC. 25 mm dia nominal bore
64Providing and fixing G.I. elbows of approved quality all complete as per instruction of EIC. 40 mm dia nominal bore
65Providing and fixing G.I. elbows of approved quality all complete as per instruction of EIC.50 mm dia nominal bore
66Providing and placing GI Sockets (reducing) 20 mm to 15 mm
67Providing and placing GI Sockets (reducing)40 mm to any smaller size
68Providing and fixing G.I. Tees (equal) 15 mm dia
69Providing and fixing G.I. Tees (equal) 20 mm dia
70Providing and fixing G.I. Tees (equal)40 mm dia
71Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge.
72Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :
73Small petty water supply related works
74Part C Tank Cleaning
75Cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank including marking the date of cleaningon the side of tank body with the help of stencil and paint and disposing of malba all complete as per direction of Engineer-in-Charge. (The old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ Rs. 0.10 per litre) (if during cleaning any GI fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account)
76Cleaning of under ground sump, Over Head R.C.C. Tank ( independent staging) including disposal of slit and rubbish, all as per direction of Engineer-in-Charge. The cleaning shall consist following operations:- (i) Tank shall be emptied of water by pumping & bottom shall be cleaned of silt and other deposits. (ii) Entire surface area of the sump shall then scrubbed thoroughly with wire brush etc. and pressure washed with water. (iii) Chlorination of RCC internal surface by liquid chlorine. (iv) The treated surface shall be dried using air jetting and all loose particles shall be removal from the surface. (v) Finally the surface shall be treated with ultraviolet radiation etc. as per direction of Engineer-in-Charge.
77Providing and fixing pvc water tank cover in tanks provided in the building including screws, PVC kundi etc. all complete as per instruction of EIC.
78Part D Chlorination plant
79Supply of liquid Chlorine ( Hypo Chlorine base formulation) for treatment of water for drinking purpose confirming to IS 11673-1992 Gr.-1 and 10500-1991 for two years.
80Operation and maintenance of chlorination plant including carrying of chemical at sites three nos. ( Reservior 20" well, Reservior Civil msint. , Reservior Barwani Pump House) as per instruction of EIC.
81Supply, installation , testing and commissioning of fully automatic online chlorination plant provided with micro processor programme logic controller with water flow sensorand proportional dosing controler with proper cross connections with pipeline inclusives of cost of maintenance for two years etc all complete
82Horticulture GM office and bunglow
83Complete maintenance of the entire garden features having as per yard stick in the garden area i.e. lawn trees, shrubs, hedge, flower beds, foliages, creepers etc. including hoeing,weeding pruning replacement of plants, gap filling, watering, mowing of lawn, grass cutting by lawn mover and brush cutter , removal of garden waste, applying insecticide, pesticide & fertilizers(whenever required) top dressing of lawn with good earth and menure and maintenance of other garden related works as directed by office-in-charge (Cost of Good Earth, Manure, Fertilizer, Insecticide , Pesticide will be provided by the Department & lawn mover and brush cutter with fuel , other T & P material/articles shall be provided by the contractor.) Play grounds / Public parks (as per yard stick 1Mali =2.00Acre).
84Maintenance of potted plant Earthen pot in displayed at ground floor only in bungalow,office complex including application of good earth, manure, insecticide, pesticide and fertilizer, removing of dry parts by pruning, cleaning dry leaves and displaying in appropriate place and replacement of broken pots coloring of pots and change of location of pots and replacing with fresh plants as and when required ( Materials shall be provided by the department) as per direction of officer in charge (For Earthen pot 750 Nos)
85Maintenance of potted plants Cement pots at ground floor in flats and ground floor bungalow,office complex including application of good earth, manure, insecticide, pesticide and fertilizer, removing of dry parts by pruning, cleaning dry leaves and displaying in appropriate place and replacement of broken pots coloring of pots and change of location of pots and replacing with fresh plants as and when required (Materials shall be provided by the department) as per direction of officer in charge (For of Cement pots 300 Nos)
86Anti termite treatment by digging pits 30 cm deep and 4 cm dia, 6 to 7 holes around the tree using chemical emulsion at the rate of 1.5 liter per hole in two time or more application to get the trees free from termite infection chemicals used Chlorpyriphos 20% EC in the ratio of 1% concentration and as per direction of officer-in-charge.
87Anti termite treatment of lawn area through premise 30.50% I P. one liter premise diluted in 499 liters water and applying solution @ 1.00 litre solution per sqm lawn or bed area.(two application) i/c cost of chemical)and as per direction of officer-in-charge.and as per direction of officer-in-charge.
88Renovating lawns including weeding, cheeling the grass, forking the ground, top dressing with sludge or manure, mixing the same with forked soil, watering and maintaining the lawn for 60 days or more till the grass forms a thick lawn free from weeds and fit for mowing and disposal of rubbish as directed, including supplying good earth if needed but excluding the cost of sludge or manure (The manure/sludge shall be paid for separately).
89Supplying and stacking of winter seasonal seedling/cutting at site of work well developed and healthy free from disease in pro tray and each per tray having 100 Nos. plants as per direction of the officer in charge. Calendula
90Supplying and stacking of winter seasonal seedling/cutting at site of work well developed and healthy free from disease in pro tray and each per tray having 100 Nos. plants as per direction of the officer in charge. Carnation
91Supplying and stacking of winter seasonal seedling/cutting at site of work well developed and healthy free from disease in pro tray and each per tray having 100 Nos. plants as per direction of the officer in charge. Chrysanthemum double
92Supplying and stacking of winter seasonal seedling/cutting at site of work well developed and healthy free from disease in pro tray and each per tray having 100 Nos. plants as per direction of the officer in charge.Dahlia double
93Supplying and stacking of winter seasonal seedling/cutting at site of work well developed and healthy free from disease in pro tray and each per tray having 100 Nos. plants as per direction of the officer in charge. Dianthuys hybrid
94Supplying and stacking of winter seasonal seedling/cutting at site of work well developed and healthy free from disease in pro tray and each per tray having 100 Nos. plants as per direction of the officer in charge. MarigoldHybrid dwarf
95Supplying and stacking of winter seasonal seedling/cutting at site of work well developed and healthy free from disease in pro tray and each per tray having 100 Nos. plants as per direction of the officer in charge. Pansy hybrid
96Supplying and stacking of winter seasonal seedling/cutting at site of work well developed and healthy free from disease in pro tray and each per tray having 100 Nos. plants as per direction of the officer in charge. Petunia hybrid
97Supplying and stacking of winter seasonal seedling/cutting at site of work well developed and healthy free from disease in pro tray and each per tray having 100 Nos. plants as per direction of the officer in charge. Salvia
98Supplying and stacking of winter seasonal seedling/cutting at site of work well developed and healthy free from disease in pro tray and each per tray having 100 Nos. plants as per direction of the officer in charge.Gazania hybrid
99Supplying and stacking of winter seasonal seedling/cutting at site of work well developed and healthy free from disease in pro tray and each per tray having 100 Nos. plants as per direction of the officer in charge. Gerbera hybrid double
100Supplying and stacking of summer & rainy seasonal seedling at site of work well developed and healthy free from disease in pro tray and each per tray having 100 Nos. plants as per direction of the officer in charge. Balsum seedling
101Supplying and stacking of summer & rainy seasonal seedling at site of work well developed and healthy free from disease in pro tray and each per tray having 100 Nos. plants as per direction of the officer in charge. Cosmos Hybrid
102Supplying and stacking of summer & rainy seasonal seedling at site of work well developed and healthy free from disease in pro tray and each per tray having 100 Nos. plants as per direction of the officer in charge. Sunflower Dwarf
103Supplying and stacking of summer & rainy seasonal seedling at site of work well developed and healthy free from disease in pro tray and each per tray having 100 Nos. plants as per direction of the officer in charge. Zinnia hybrid
104Supplying and stacking of summer & rainy seasonal seedling at site of work well developed and healthy free from disease in pro tray and each per tray having 100 Nos. plants as per direction of the officer in charge. Kochia
105Supplying and stacking of plant mussaenda (erythrophylia) of height 60-75 cm. Multi branched in earthern pots of size 25 cm as per direction of the officer-in-charge
106Providing and displaying plants Budded rose (H.T. Variety) 3 to 4 healthy branch 30 cm and above ht. well developed with one and above flower plant in 20 cm . Earthen pot as perdirection of the officer-in-charge
107Providing and displaying of cephortia palm, having ht. 1.20 mtr. to 1.50 mtr.with 8-10 suckers well developed fresh and healthy lush gree leaves from bottom to top in 25 cm size of earthen pot/plastic pot and asper direction of the officer-in-charge.
108Providing and displaying of Croton Golden plant, having ht.45 cm to 60 cm with 2 to 3 branches, well developed, fresh and healthy foliage in 25 cm size of Earthen pot/Plastic pot as per direction of the officer-in-charge.
109Providing and displaying of Areaca Palm plant havinght 90 cm to 1.20 mtr with 4 to 5 suckers, well developed fresh and healthy with lush green foliage in 20 cm size of earthern pot/ plastic pot and as perdirection of the officer-in-charge
110Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unserveiceable material’s as per direction of officer in charge (excluding cast of plant & water), Shrubs Plant
111Supplying and stacking of good earth at site including royalty and carriage upto 5 km complete (earth measured in stacks will be reduced by 20% for payment).
112Supplying and stacking sludge at site including royalty and carriage upto 5 km complete (sludge measured in stacks will be reduced by 8% for payment).
113Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge
114Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately).
115Surface dressing of the ground including removing vegetation and in- equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. All kinds of soil.
116Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work.
117Providing Circular Cement Concrete pots of specified size, cast with cement concrete of nominal mix 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 6 mm nominal size), reinforced with 7 Nos ( 3 nos horizontal & 4 nos vertical “ U “ shape) M.S. wires of 3.5 mm dia as per design, including required form work, finishing with cement punning on exposed surface, curing for specified period and stacking in required rows & height, all complete as per direction of Officer-in-charge. Top inside dia 35 cm, outer bottom dia 25 cm, total height 35 cm with wall thickness of 25.4
118Supply of earthen pot 12 "
119Filling of the following size empty pots with mixture of good earth & manure in the ratio of 2:1 (Two part of Good earth & one port of manure) and placing them on appropriate place i/c carriage of earth, manure and pots up to 50 mtr, as per direction of officer incharge. (The cost of good earth, earthen pots & manure will be paid separately.) Size of Empty Pots 35cm Top dia, 25cm Bottom Dia & 35cm Perpendicular height.
120Pest Control
121Anti adult measure:General disinfection/Pest control with new generation odurless, colourless insecticides which should be safe for human being and effective for all kind of house hold insects like mosquitos, house flies, etc. using Residual spary of Deltarmethrin 2.5% SC Flow (K.Othrine or approved equivalent), insecticides should be sprayed uniformly over the surfaces of walls, ceiling etc. Frequency- Once in 3 Months.
122Thermal fogging using insecticide Deltarmethrin 1.25% ULV (Kingfog or approved equivalent) mixed with Diesel in the ratio of 1:199, for outdoor operatioon of colony, etc. Frequency- Monthly.
123Anti larva measures :- Treatment by using Diflubenzuron 25% WP (Bi- larv or approved equivalent) solution to be spread as per instructions of EIC. Frequency – weekly.
124Anti adult measure:General disinfection/Pest control with new generation odurless, colourless insecticides which should be safe for human being and effective for all kind of house hold insects like mosquitos, house flies, etc. using Residual spary of Cyfluthrin 5% EW (Solfac EW 050 or approved equivalent) insecticides should be sprayed uniformly over the surfaces of walls, ceiling, etc.Frequency- Once in 3 Months.
125Sanitation colony
126Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth leadupto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil
127Carriage of materials by mechanical transport including loading, unloading and stacking etc earth lead upto 1.00 Km.
128Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. All kinds of soil.
129Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
130Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared .
131Carriage of materials by mechanical transport including loading, unloading and stacking etc lime, moorum, building rubbish etc.lead upto 1.00 Km.
132Cleaning of surface drain and disposal of muck/sludge through trolly or other arrangement to a specified place (in no case it shall be kept on drain banks) within a lead of 1 KM complete with all tools and tackles as per instruction of EIC. Upto 300 mm wide.
133Cleaning of surface drain and disposal of muck/sludge through trolly or other arrangement to a specified place (in no case it shall be kept on drain banks) within a lead of 1 KM complete with all tools and tackles as per instruction of EIC.above 300 mm Upto 600 mm wide.
134Cleaning of surface drain and disposal of muck/sludge through trolly or other arrangement to a specified place (in no case it shall be kept on drain banks) within a lead of 1 KM complete with all tools and tackles as per instruction of EIC.above 600 mm wide.
135Disposal of dead animals including transporation to the specified place, making earthpit disposal of dead animals into pit with adequate quantity of salt, lime, bleaching powder etc. and refilling the pit with earth all complete with tools tackles and consumable as per instruction of EIC Big animal (Cow buffalo, ox and the like)
136Disposal of dead animals including transporation to the specified place, making earthpit disposal of dead animals into pit with adequate quantity of salt, lime, bleaching powder etc. and refilling the pit with earth all complete with tools tackles and consumable as per instruction of EIC Small animal (Dog, Cat, Fox, pig, birds and the like)
137Brooming and cleaning of all roads in colony and within the premises of the service building and other places as required with all tools and tackles and stacking the garbage at specified place as per instruction of EIC.
138Removing and uprooting of unwanted Vegetation grown over the drainage pipes, walls, chhajjas, balcony and similar locaton of building upto floor Vth level with all tools & plants required with safety precautions and making good the same with plaster including disposal of material / tree roots etc. at the required place all complete as per instruction of EIC.
139Collection of garbage from door to door and disposal of the same through trolly or other suitable arrangement to the specified place within lead of1 KM including of sweeping of stair case (for 1st and 2nd floor quarters with all tools and tackles as per instruction of EIC. Ground Floor
140Collection of garbage from door to door and disposal of the same through trolly or other suitable arrangement to the specified place within lead of1 KM including of sweeping of stair case (for 1st and 2nd floor quarters with all tools and tackles as per instruction of EIC. First Floor (172 Unit x 305 days x 2 years = 104920.00)
141Collection of garbage from door to door and disposal of the same through trolly or other suitable arrangement to the specified place within lead of1 KM including of sweeping of stair case (for 1st and 2nd floor quarters with all tools and tackles as per instruction of EIC. Second Floor (46 Unit x 305 days x 2 years = .00)
142Cleaning of toilet(Floor area upto 10 sqm ) including cleraning of dado, skirting, WC pan (indian type/western type), wash basin,urinals, glass shelves, mirror and other fittings, if any for D-type or equivalent quarter, any other wash basin outside the toilet by hand dusting and clening with soap solution, acids, deodrants, Phenyl etc. to make the toilet clean and hygenic all complete as per instruction with all tools and tackles and consumable (15 Units x 03 toilets 52 weeksx 02 years = 4680.00 Nos. )
143Cleaning of toilet(Floor area upto 8 sqm ) including cleraning of dado, skirting, WC pan (indian type/western type), wash basin,urinals, glass shelves, mirror and other fittings, if any for C-type or equivalent quarter, any other wash basin outside the toilet by hand dusting and clening with soap solution, acids, deodrants, Phenyl etc. to make the toilet clean and hygenic all complete as per instruction with all tools and tackles and consumable (78 Units x 02 toilets 52 weeks x 1x 02 years = 16224 Nos. )
144Cleaning of toilet including WC pan, wash basin other fittings, if any for "B" & lower type quarter by hand dusting and clening with soap solution, acids, deodrants, Phenyl etc. to make the toilet clean and hygenic all complete as per instruction with all tools and tackles (406 Units x 01 toilets 52 weeks x 02 years = 42224 Nos. )
145Cleaning , mopping & washing of floor of public buildings other places neatly with detergent / bleaching powder etc. all complete with tools, tackles and consumable to make the floor clean & hygienic as per instruction of E.I.C.Floor
146Cleaning of toilets attached with hostel rooms, office chambers etc. including floors, skirting and dado, W.C. Pan (Indian/European type), wash basin, Shelves, mirror and other fittings, if any, by hand dusting and cleaning with soap solution, acids, deodorants, phenyl etc, to make the toilet clean and hygiene and providing naphthalene ballsa in urinals complete with all tools, tackles and consumables as per instruction of EIC (for community and service building)
147Cleaning of general / commontoilet including cleaning of WC Pan (Indian/European type) wash basins,urinals by hand dusting and cleaning with soap solution, acids, deodorants, phenyl etc, to make the toilet clean & hygienicand providing naphthalene balls in urinals complete with all tools, tackles & consumables as per instruction of EIC.
148Cleaning of toilet (floor area upto 10 sqm.) including cleaning of dado, skirting, WC Pan (indian type western type), wash basins, urinal glassshelves, mirror and other fittings, etc. all complete.
149Cleaning of all types of roof including removal of dry leaves, weedings and cleaning dram holes, brooming etc. all complete with tools & tackles andstacking the garbage at specified places as per instruction of EIC.
150Cleaning of doors shutters , windows shutters including chowkhats , window grills , glass panes , cobwebs etc. of service community buildings with necessary detergents , chemicals etc complete as per instruction of EIC
151Cleaning of Toiletsincluding WC Pan, wash basins, other fittings, if any for "B type & lower type quarter by hand dusting and cleaning with soap solution acids & phenyl etc. to make the toilet clean and hygienic all complete with all tools, tackles as per instruction of EIC. (1248 Units x 01 toilets 52 weeks x 1x 02 years = 16224 Nos. )
152Cleaning of choked sewer & sludge line of all diameters including removal of earth opening joints, cleaning of pipe line, making joints leak proof etc. all complete including disposal of sludge materials outside the colony with all leads at Specified place with tools & tackels as per instruction of EIC
153Repair and maintenance
15412 mm cement plaster of mix : 1:6 (1 cement: 6 fine sand)
1556 mm cement plaster of mix :1:3 (1 cement : 3 fine sand)
15612 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand)
157Brick work with non modular fly ash lime brick (FALG bricks) confirming to IS:12894,class 7.5 average compressive strength etc. complete in all respect in foundation & plinth : in cement mortar 1:6 (1 cement: 6 sand)
158Brick work with non modular fly ash lime brick (FALG bricks) confirming to IS:12894,class 7.5 average compressive strength etc. complete in all respect in above plinth level in Superstructure upto floor V : in cement mortar 1:6 (1 cement: 6 sand)
159Half Brick work with non modular fly ash lime brick (FALG bricks) confirming to IS:12894,class 7.5 average compressive strength etc. complete in all respect in foundation & plinth : in cement mortar 1:4 (1 cement: 4 sand)
160Half Brick work with non modular fly ash lime brick (FALG bricks) confirming to IS:12894,class 7.5 average compressive strength etc. complete in all respect in superstructure : in cement mortar 1:4 (1 cement: 4 sand)
161Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
162Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
163Providing, hoisting and fixing up to floor five level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but excluding cost of reinforcement, with 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size).
164Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Cold twisted bars
165Grading roof for water proofing treatment withCement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
166Brick on edge flooring with bricks of class designation 7.5 on a bed of 12 mm cement mortar, including filling the joints with same mortar, with common burnt clay non modular bricks:1:6 (1cement : 6 coarse sand)
167Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
168Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete.
169Providing and fixing soil, waste and vent pipes :100 mm diaSand cast iron S&S pipe as per IS: 1729
170Providing and fixing plain bend of required degree.100 mm diaSand cast iron S&S as per IS - 1729
171Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete.100 mm diaSand cast iron S&S as per IS - 1729
172Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter
173Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Bend 87.5°110 mm bend
174Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Shoe (Plain)110 mm Shoe
175Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110 mm
176Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors :100 mm inlet and 100 mm outletSand Cast Iron S&S as per IS: 1729
177Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
178Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
179Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.In cement mortar
180Providing and fixing white vitreous china water closet squatting pan (Indian type) :Orissa pattern W.C. pan of size 580x440 mm
181Providing and fixing white vitreous china pedestal type (European type/ wash down type) water closet pan.
182Providing and fixing kitchen sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P. brass waste complete, including painting the fittings and brackets, cutting and making good the walls wherever required:White glazed fire clay kitchen sink of size 600x450x 250 mm
183Providing and fixing 100 mm sand cast Iron grating for gully trap.
184Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings /wooden frames with rawl plugs screws etc.
185Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
186Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete :250x16 mm
187Providing and fixing Pre-laminated flat pressed 3 layer (medium density) particle board or graded wood particle board IS : 3087 marked, with one side decorative and other side balancing lamination Grade I, Type II exterior grade IS : 12823 marked, in shelves with screws and fittings wherever required, edges to be painted with polyurethane primer (fittings to be paid separately).18 mm thick
188Providing and fixing ISI marked M.S. pressed butt hinges bright finished with necessary screws etc. complete :100x58x1.90 mm
189Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete :150x10 mm
190Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete :200x10 mm
191Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete :100 mm
192Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :300x16 mm
193Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :100 mm
194Providing and fixing aluminium tee channels (heavy duty) with rollers & stop end in pelmets as curtain rod.
195Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.0.63 mm thick with zinc coating not less than 275 gm/ m²
196Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete :125 mm
197White washing with lime to give an even shade :Old work (one or more coats)
198Finishing walls with Acrylic Smooth exterior paint of required shade : Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface
199Distempering with 1st quality acrylic distember (Ready mix) having VOC content less than 50 grams/ litre of approved brand and manufacture to give an even shade : Old work (one or more coats)
200Applying priming coat:With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood)
201Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
202Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over and including water thinnable priming coat with cement primerDEDUCT OFApplying one coat of water thinnable cement primer of approved brand and manufacture on wall surface.
203Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two or more coats on new work
204Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :One or more coats on old work
205Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade:One or more coats on old work
206Lettering with black Japan paint of approved brand and manufacture
207French spirit polishing :One or more coats on old work
208Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed.All kinds of soil
209Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil.
210Renewing glass panes and refixing existing wooden fillets:Float glass panes of thickness 4 mm
211Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of:G.S. Sheet
212Welding by gas or electric plant including transportation of plant at site etc. complete.
213White washing with lime to give an even shade : Old work (two or more coats)
214Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete
215Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.(item no. 14.46)
216Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
217Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws : 30 mm thick shutters With ISI marked stainless steel butt hinges of required size Kiln seasoned and chemically treated hollock wood Deduct for not providing hinges in doors, windows or clerestory window shutters with : Stainless steel butt hinges with stainless steel screws : For 2nd class teak wood and other class of wood shutters
218Providing lead caulked joints to spun iron or C.I. pipes and specials, including testing of joints but excluding the cost of pig lead : 100 mm diameter pipe
219Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two or more coats on new work
220Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm
221Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws Deduct for not providing hinges in doors, windows or clerestory window shutters withStainless steel butt hinges with stainless steel screws For 2nd class teak wood and other class of wood shutters
222Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge.With stainless steel cover plate minimum 1.25 mm thickness
223Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
224Neat cement punning.
225Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately).Sal wood
226Colour washing such as green, blue or buff to give an even shade :New work (two or more coats) with a base coat of whiting
227Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:25 mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. piano hinges with necessary screws
228Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using flats 30x6mm for diagonal braces and central cross piece
229Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper
230Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate
231Distempering with 1st quality acrylic distemper (ready mixed) of approved manufacturer, of required shade and colour complete, as per manufacturer"s specification. Two or more coats on new work
232Centering and shuttering including strutting, propping etc. and removal of form for all heights : Shelves (Cast in situ)
233Finishing walls with Acrylic Smooth exterior paint of required shade : Old work (One or more coat applied @ 0.90 ltr/10 sqm)
234Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete.With 2nd class teak wood beading 62X19 mm
235Surface dressing of the ground including removing vegetation and in- equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m.All kinds of soil
236Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :250x16 mm
237Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :250x10 mm
238Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :150x10 mm
239Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :125 mm
240Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :100 mm
241Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead :Of area 3 sq. metres and below
242Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :Of area 3 sq. metres and below
243Providing and fixing PVC Door Frame of size 50x47 mm with a wall thickness of 5 mm (± 0.2 mm), made out of single piece extruded PVC profile, with mitred cut joints and joint with 2 nos of PVC bracket of size 190 mm x 100 mm long arms of cross section size 35 x 15 mm & self driven self taping screws, the vertical door profiles to be reinforced with 40x20 mm M.S. rectangular tube of 0.8 mm , including providing EPDM rubber gasket weather seal throughout the frame, including jointing 5 mm PVC frame strip with PVC solvent cement on the back of the profile. The door frame to be fixed to the wall using 8 x100 mm long anchor fasteners complete, all as per manufacturer"s specification and direction of Engineer -in- charge.+
244False ceiling
245Providing and fixing to existing door frames.24 mm thick factory made PVC door shutters made of styles and railsof a uPVC hollow section of size 59x24 mm and wall thickness 2 mm (±0.2 mm) with inbuilt edging on both sides. The styles and rails mitred and joint at the corners by means of M.S. galvanised/ plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 20x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of "H" section, a uPVC hollow section of size 100x24 mm and 2 mm (± 0.2 mm) wall thickness, fixed to the shutter styles by means of plastic/galvanised M.S. "U" cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness. The panels filled vertically and tie bar at two places by inserting with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall horizontally 6 mm galvanised M.S. rod and fastened with nuts andwashers, complete as per manufacturer"s specification and direction of Engineer-in-charge. (For W.C. and bathroom door shutter).
246Providing and fixing 100mm brass locks (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete.
247Providing and fixing 18 mm thick, 150 mm wide pelmet of flat pressed 3 layer or graded wood particle board medium density grade I, IS : 3087 marked, including top cover of 6 mm commercial ply wood conforming to IS: 303 BWR grade, nickel plated M.S. pipe 20 mm dia ( heavy type) curtain rod with nickel plated brackets, including fixing with 25x3 mm M.S. flat 10 cm long fixed to pelmet with hollock wood cleats of size 100 mm x 40 mm x 40 mm on both inner side of pelmet and rawl plugs 75 mm long etc. all complete.
248Providing and fixing plain bend of required degree.75 mm diaSand cast iron S&S as per IS -1729
249Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge 30 mm thick shutters
250Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick :Second class teak wood
251Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
252Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size).
253Providing and fixing nickel plated M.S. pipe curtain rods with nickel plated brackets : 25 mm dia (heavy type)
254Providing and fixing aluminium work for doors,windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately): For fixed portion Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
255Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness
256Providing and fixing aluminum U beading of required size to Pre-laminated/ flush door shutter, including fixing etc. complete as per direction of Engineer-in-charge
257Repair to plaster of thickness 12mm to 20 mm in patches of area 2.5 sqm and under, including cutting the patch in proper shape, raking out joints and preparing plastering the wall surface with white cement based polymer modified self curing mortar, including disposal of rubbish, all complete as per the direction of EngineerIn-Charge.
258Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement: 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade. Area of slab over 0.50 sqm
259Small petty carpentary work such as small repair of doors,window,making hole,fixing of miscellaneous fixtures etc.
260Facility Manager
261Assistant Facility Manager 04 numbers per day
262Hospital Sanitation
263Day to day cleaning of hospital building round the clock by deploying 25 Nos. of workersin General and all the three shifts i.e. First shift (6.00 AM to 2.00 PM), Second shift (2.00 PM to 10.00 PM), and Third shift (10.00 PM to 6.00 AM). The scope of work includes manual/mechanized cleaning which Shall include wet and dry cleaning of Floor, dado, wall tiles, furniture, cleaning of toilets including fixtures and fittings like wash basin including counter, sink, mirror, urinals, towel rail, WC/European pan etc. cleaning of doors, windows, window glass pan, racks, Apparatus, Bed frames, Bedside table, Dustbin, Faucet handle, Door, display boards, cleaning be pan etc. Double wages recovery will be made for less deployment of manpower as stated in scope of work.
264Disposal of accumulated garbage hospital waste (excluding Bio-medical Waste) from various location of Hospital complex minimum two trips per day by deploying a Tractor Taylor with diver, diesel, POL and sufficient manpower etc. for loading and unloading of garbage to disposal point as per instruction of Engineer-in-charge (with all lead & lifts).
265Supplying and application of the following toiletries like, Vim, Phenyl, Naphthalene balls, sanifresh, toilet liquid soap toilet soap, Mosquito repellent etc as per instruction of EIC,.
266Porcelain cleaning power (Vim or Equivalent
267Liquid disinfectant (White Phenyl) Dr. Brand or Equivalent ISI Marked
268Liquid toilet cleaner (500 ml Bottle) (Harpic or Equivalent)
269Nephthalene balls. (ISI Marked)
270Liquid Soap. (Dettol or Equivalent)
271Toilet Soap 125 gram. (Lifebuoys or Equivalent)
272Odonil (50 Gram)
273Bleaching Powder
274Detergent Powder
275Room Freshener 115 ml
276Colin (500 ml Bottle)
277Estimate for Maintenance of Power Supply and Distribution System for 02 years ofTownship at Bina Project.
278Maintenance of Power Supply and Distribution System of the Township including Maintenance of OH Line,Power Transformers,Feeder Pillars and Bus Bars,Household Wiring and electrical circuit related works,Service Line Connection etc as required on day to day basis[Minimum Manpower to be engaged 4 electricians(Skilled),8 electrical helpers(4 semi skilled and 4 unskilled)]
279Estimate for repairing / servicing & maintenance of air conditioners , water coolers and refrigerators as & when required for 02 years at Bina Project(Township)
280Supply of frion gas R22 /R410/ R32 A for replacement .
281Supply of running capacitor 25 to 36 mfd fr replacement.
282Supply of running capacitor 45 to 50 mfd fr replacement.
283Supply of fan/blower motor condensor 4 to 6 mfd for replacement.
284Supply for steel water tap for water cooler for replacement
285Supply of float valve with complete set for water cooler for replacement
286Replacement of defective compressor by Brand new 2 Ton rotary compressor with accumulator for window/split Acs.suitable for 180-250V AC,50Hz Supply,10Amps of standard make
287Replacement of defective compressor by Brand new 1.5Ton rotary compressor with accumulator for window/split Acs.suitable for 180-250V AC,50Hz Supply,10Amps of standard make
288Supply of 412/522/4440 model new compressor by for 40 to 60 Ltr cooler (make Emerson Copland/Blue Star/LG of any Std make)for replacement
289Supply of PCB Circuit for Replacement
290Repairing / rewinding of Fan motor of AC and water cooler.
291Supply of thimble for replacement .
292Supply of fan blade for AC and water cooler for replacement .
293Supply of thermostat for AC and water coolers for replacement
294Supply of fan motor with blade & stand for water coolers for replacement .
295Supply of bush, screw of required size for AC and water coolers for replacement .
296Supply of AC remote panel assembly with remote for replacement .
297Supply of refrigeration copper pipe for AC and water cooler for replacement
298Complete body makingwith supply of new sheet and angle painting glass wool changing, gas charging and bib cock capacity 150 Ltr, water coolers of different make.
299Supply of air filter for air conditioners for replacement .
300Labour Charge
301Repairing/servicing includingfilling of gas for 180 Nos. air conditioners, 15 Nos water coolers and 07 Nos. refrigerators and attending running break downs and maintenanceat site (with a team of one skilled technician & two helper per day)
302Estimate for repair & maintenance of submersible pump motor sets installedin Township for 02 years of Bina Project.
303Lifting of submersible pump from borewell
304Repairing & Rewinding of submersible pump motor set
305Lowering,Testing & commissioning of submersible pump motor set
306Supply & fixing of nylon rope 20mm
307Electrical Maintenance of 500 No.s newly alloted residential quarters of Bina project & Electrical Wiring Maintenance of various residential quarters and service buildings.
308Wiring for light point/ fan point/ exhaust fan point/ call Bell point with 1.5 sqmm. FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single for cable etc. as required.
309Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC Insulated Copper Conductor,single core cable in surface/recessed medium class PVC Conduit as required 2X2.5sqmm+1X2.5sqmm earth wire.
310Wiring for light/power plug with 2X4 sqmm FRLS PVC insulated copper conductor single core cable in surface/recessedmedium class PVC Conduit along with 1 no. 4 sqmm FRLS PVC Insulated Copper conductor Single Core cable for loop earthing as required
311Installation,Testing and commissioning of Led Tube Light Fittings directly on ceiling/wall complete with all accessories including connections[Material to be supplied by department]
312Installation,Testing and commissioning of Ceiling Fan including wiring the down rods of standard length of 30cm with 1.5sqmm FRLS PVC Insulated,copper conductor,single core cable etc as required[Material to be supplied by department]
313Supply & Fixing of board 8"X10" with sunmica cover
314Supply & Fixing of board 8"X6" with sunmica cover
315Supply & Fixing of board 7"X4" with sunmica cover
316Supply & Fixing of board 4"X4" with sunmica cover
317Electrical wiring maintenance of residential qtrs and service buildings
318Supply and drawing of 2X 2.5 sqmm single core PVC insulated stranded aluminium conductor wire as per IS standards with 16 SWG GI wire as required on wiring replacement
319Supply and drawing of2X4 sqmm single core PVC insulated stranded aluminium conductor wire as per IS standards with 16 SWG GI wire as required on wiring replacement
320Fixing of one way 5amps F/T switch including connections etc as required[material supplied departmentally]
321Fixing of 5 ampssocket outletincluding connections etc as required [material supplied departmentally]
322Fixing of 15ampsswitch-socket combined typeincluding connections etc as required.[material supplied departmentally]
323Supply & Fixing of board 8"X10" with sunmica cover
324Supply & Fixing of board 8"X6" with sunmica cover
325Supply & Fixing of board 7"X4" with sunmica cover
326Supply & Fixing of board 4"X4" with sunmica cover
327Supply & fixing of 20mm casing caping of standard make ISI mark(02 mtr long)
328Estimate for Greasing,Maintenance & Rewinding of AC ceiling fans installed at various types of residential quarters & service buildings for02 yearsat Bina Project.Part(A)-AC Ceiling Fans greasing,maintenance
329Dismantaling & re-installation after complete overhauling greasing, oiling of Ac ceiling fans.
330Supply & changing of bearing (6201, 6202 & 6203)
331Replacement of capacitor 2.5mfd, 400V as per instruction of Engineer Incharge.
332Supply & changing of metalic bush as per instruction of EIC.
333Supply & changing of metalic shaft as per instruction of EIC.
334Supply & changing of rubber bush as per instruction of EIC.
335Supply & changing of nut bolts of required size.
336Estimate for Repair, Rewinding&Maintenance of Exhaust fans (300 mm) installed at various types of residential quarters & service buildings for 02 years at Bina
337Copperwire 320gm each for rewinding
338Bearing set
339blade
340Condenser 2.5 mfd
341shaft and bush
342Labour charges
343Contractor Profit
344AC Ceiling Fans Rewinding
345Rewinding of AC Ceiling Fans with rewinding materials including connecting wires
346Estimate for Tree trimming and Bush cleaningunder HT/LT OH lines of Township for 02 years at Bina
347Tree Trimming fallingunder HT/LT lines including uprooting of ranks , vegetation , grass , bushes, wood saplings & tree etc. not exceeding 30 cm girth and removing 5 mtrs., outside the periphery of the area cleaned (in sqm) 3KM X 2 mtrs. ( 1mtr on both side under HT line X 2 times), 16KM X 2 mtrs. ( 1 mtr on both sides under LT line X 2 times)( 12000 sqm + 64000 sqm = 76000 sqm)
348Estimate formaintenance of various running pumps for water supply in township
349Upkeep and maintenance including cleaning,tightening of bolts,greasing,foot valve cleaning/checking,replacement of damaged bearing,alignment of pump-motor,welding/cutting related works if any etc with a group of 4 nos. labours (2skilled + 2unskilled)as per instruction of EngineerIncharge.Tools, Tackles & consumables like gland packing etc as per instruction of EIC @ 4%
350Estimate for Repairing/Rewindingof 04 Nos 22KW/30HP 3phase induction motor as & when required for colony water supply for 02 yearsat Bina project
35122KW,415LT motor Make:Crompton greaves(01no)
352Super enamel copper wire 20swg
353Nomex Paper for insulation
354Insulating varnish Dr. beck
355Glass Tape
356Terminal Cover
357Soldering materials with connecting lead and lugs
358Bearing housing repairing
359Labour charges for all work including testing of motor
360Less cost of old scrap wire
361Estimate for Repairing/Rewindingof 04 Nos 22KW/30HP 3phase induction motor as & when required for colony water supply for 02 yearsat Bina project
36222KW,415LT motor Make:Kirloskar (03no)
363Super enamel copper wire 20swg
364Nomex Paper for insulation
365Insulating varnish Dr. beck
366Glass Tape
367Soldering materials with connecting lead and lugs
368Labour charges for all work including testing of motor
369Less cost of old scrap wire
370Estimate for Repairing/Rewindingof 01 Nos 37KW/50HP 3phase induction motor as & when required for colony water supply forThree months at Bina project
371Super enamel copper wire 17/18 swg
372Nomex Paper for insulation
373Fibre Glass Tape
374Fibre Glass Wedge
375Mica Paper
376Soldering materials
377Dr.Veck Insulation Varnish
378Fibre Glass Sleeve
379Soldering materials
380Dr.Beck Insulation Varnish
381Bearing 6313
382Labour Charges on item S.No 1 to 5
383Less cost of old scrap wire
384Estimate for Repair/Maintenance of HT/LT Overhead Lineof Township area for 02 years at Bina project
385MS nut bolt 5/8X8", 3",4" asper requirement of EIC.
386GI Earth Wire 7/14SWG(0.206 Kg/mtr)
387Stay Wire 7/10 SWG(0.480 Kg/mtr)
388cement ( 1 bag per pole & 1/2 per stay)
389Disc Insulator 11kV Grade
390Pin Insulator 11kV Grade
391Stay Rod Complete Set 3/4"X6"
392Hardware Tension Type for Wolf/Dog Conductor
393Stay insulator
394shackle insulator/Pin insulator 1.1kV grade with clamp set
395Outdoor Feeder Pillar metal close water tight dust and vermin proof with following device 1)01 No.: ICTPN Main Switch 63 Amps 2) Bus Bar 200 Amps Copper
396Labour and supply
397Preparation of surface by two coat painting with super enamel paint and writing volateg grade,feeder number,pole number on pole inlcuding supply of paint and cleaning of area to be painted
398Supply,designing,cutting,preparing,surfacing high intensity retro reflective sheet sheet stickers as required including 5% carriage and wastage as per IRC 67-2001
399Providing and Fixing of MV(220/415/440V) Danger Noticeplate of 200mmX150 mm,made of mild steel,at least 2mm thick and vitreous enameled white on both sides and with inscription in single red color on front side as required
400Providing and Fixing of HT(6.6/3.3kV) Danger Noticeplate of 200mmX150 mm,made of mild steel,at least 2mm thick and vitreous enameled white on both sides and with inscription in single red color on front side as required
401Painting with two coat aluminium paint of approved brandto give an even space for 300 Nos of 11 mtr-4.53 sqm area each &100 HT poles of size 13m long-5.30 sqm area each.[total area=300X4.53+100X5.30=1889]
402Earthing with GI pipe 4.5 mtr long,40mm dia including accesories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc with charcoal/coke and salt etc
403Supplying and Laying 6 SWG GI Wire at 0.5 mtr below ground level for conductor earth electrode including connection/termination with GI Thimble etc as required.
404Labour Part
405Dismantling of ACSR/AAA conductor wolf/dog including insulators and brackets
406Dismantling of earth wire / guard wire.
407Dismantling of DC cross arm
408Digging of rail/tubular pole 11/13 mtr long
409Collection of ACSR conductor including insulators.
410Collection of 11/13 mtr MS rail/tubular pole for erection & after digging out at specific place as per instruction of EIC
411Erection of MS rail/Tubular pole 11/13mtr long including digging of earth pit &concreting with mine boulder (excluding cement)
412Fixing of Stay Rod including digging of earth pit and concreting with mine boulder as per EIC
413Fixing of DC Channel on DP,TP etc
414Fixing of single bracket on single pole
415Fixing of top bracket on single pole
416Fixing of Disc Insulator
417Jumpering work in HT Overhead line
418Stringing of AAA Conductor
419Stringing of GI Earth Wire
420Fixing of guarding bracket with net
421Fixing of Pin/shackle insulator
422fixing of stay insulator
423Fabrication of OH Line bracket,lighting bracket,earthing clamp,Clamp brackets,guarding bracket with calmps etc as per instruction of EICby MS angle 65X65X6mm & MS channel(100X50)(Angle will be supplied by the Deptt.)
424Loading,unloading & laying of PVC Double armouredcopper HT Cables of 11kV Grade 3X35/50/70/95 sqmm with sufficeint manpower as per instruction of EIC
425Total impact of GST for the purpose of CTC