Tender For Repair Maintenance And Improvement Of Lt Panel Incl Lt Switch Gear, Earthing, Timer Panel, Lt Poles, Pole Box, Outdoor Street Lights, Flood Lights, Area Lights, Lt Distr Network And Connected Items At Bs Marg, Def Colony, 6 / 11 Gr Un, lucknow-Uttar Pradesh

Military Engineer Services-MES has published Tender For Repair Maintenance And Improvement Of Lt Panel Incl Lt Switch Gear, Earthing, Timer Panel, Lt Poles, Pole Box, Outdoor Street Lights, Flood Lights, Area Lights, Lt Distr Network And Connected Items At Bs Marg, Def Colony, 6 / 11 Gr Un. Submission Date for this Tender is 30-04-2024. Electrification Work Tenders in lucknow Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

43102920
Corrigendum : Tender For Repair Maintenance And Improvement Of Lt Panel Incl Lt Switch Gear, Earthing, Timer Panel, Lt Poles, Pole Box, Outdoor Street Lights, Flood Lights, Area Lights, Lt Distr Network And Connected Items At Bs Marg, Def Colony, 6 / 11 Gr Un
Open Tender
Indian
Uttar Pradesh
lucknow
30-04-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Repair Maintenance And Improvement Of Lt Panel Incl Lt Switch Gear, Earthing, Timer Panel, Lt Poles, Pole Box, Outdoor Street Lights, Flood Lights, Area Lights, Lt Distr Network And Connected Items At Bs Marg, Def Colony, 6 / 11 Gr Unit, 4 / 3 Gr, 16 Rajput

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 23-Apr-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 30-04-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 98000.0 /-
Tender Value
INR 49 Lakhs /-

Attachment

FileName File Description File Size
46b38bdf-4022-4865-b8f2-84b3059f9e87.html Tender Notice 0 KB
BOQ_726806.xls Tender Document 0 KB
Tender16.pdf Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

NAME OF WORK: REPAIR MAINTENANCE AND IMPROVEMENT OF LT PANEL INCLUDING LT SWITCH GEAR, EARTHING, TIMER PANEL, LT POLES, POLE BOX, OUTDOOR STREET LIGHTS, FLOOD LIGHTS, AREA LIGHTS, LT DISTRIBUTION NETWORK AND CONNECTED ITEMS AT BS MARG, DEF COLONY, 6/11 GR UNIT, 4/3 GR, 16 RAJPUT, 7 KUMAON, PIONEER UNIT, 41 INF BDE IN THE AREA OF AGE E/M EXT (ELECT) UNDER GE E/M LUCKNOW
Sl. No. Item Description
1Excavation in trenches not exc. 1.5 m wide and not exc 1.5 mtr deep in soft / loose soil for laying / taking up / taking down of cables and getting out and levelling of bottom suface to required level all as specified and directed by Engineer- in- Charge.
2Returning filling in,. Including spreading, levelling,. Watering and well ramming soil in layers not exceeding 25 cm thick all as specified and directed.
3Removing excavated material (ie soil) from site to a distance n. exc 50 mtrs away and depositing where directed at a level n. exc. 1.5 mtr above the starting point all as specified and directed by Engineer-in-Charge.
4M&L for providing dry river sand as in sand cushioning below and above cable thickness as specified in SSR to under ground cable including punning down of sand in layer all as specified and directed by Engg-in-Charge. Note: for measurement purpose punned thickness of sand will be consider.
5M&L for laying well burnt old sizebricks, sub class "B" bricks, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection complete all as specified & directed by Engr-in-Charge.
6All as per srl item No 5 here-in-before but using old bricks obtained under srl item No1 here in before.
7M&L for demolition / cutting of road / path / hardstading / concrete in floor, etc for laying of cable complete all as directed at site by Engr-in-charge
8Material and labour for PCC1:2:4 type B-2 using 40 mm graded stone aggregates for filling of cutting of roads / path / hardstanding etc complete all as specified and as directed by Engineer-in-Charge.
9Deployment of tools & manpower for Boring of hole under road / pavement / hard standing or any other situation by manual means suitable for passing of 40 to 80 mm bore pipe and making good both ends all specified and directed
10M&L for 80 mm bore mild steel galvanised water tubing, light grade with all fittings and fixed to walls or laid onfloors / fixed to poles / or passing under road crossing, for protection of UG cable including taking out old pipe complete all as specified and directed by Engr-in-Charge.
11M&L for 50 mm bore mild steel galvanised water tubing, light grade with all fittings and fixed to walls or laid onfloors / fixed to poles / or passing under road crossing, for protection of UG cable including taking out old pipe complete all as specified and directed by Engr-in-Charge.
12M&L for 40 mm bore mild steel galvanised water tubing, light grade with all fittings and fixed to walls or laid onfloors / fixed to poles / or passing under road crossing, for protection of UG cable including taking out old pipe complete all as specified and directed by Engr-in-Charge.
13Material & Laying, jointing and testing in replacement of LT under ground electric power cablecrossed linked polyethylene ( XLPE)insulated, galvanised steel strip or wire armoured,ISI-7098 Marked, with aluminium conductor multi stranded , heavy duty 1100 Volts grade of size 10 sqmm cross sectional area, 2 core ,complete all as specified laid in trenches/ laid under floor or fixed naked with walls / on poles/ in ducts /in GI pipes etc. with and including MS Clamps, nuts , bolts, washers complete all as specified and directed. Note :-Excavation, earth work, sand cushioning, protection bricks/ tiles/ block andpipe shall be measured and paid separately under appropriate items.
14All as per item No 13 above butLT UG cable of size 16 Sqmm 2 core
15All as per item No 13 above but LT UG cable of size 16 Sqmm 4 core
16All as per item No 13 above but LT UG cable of size 25 Sqmm 4 core
17All as per item No 13 above but LT UG cable of size 35 Sqmm 3.5 core
18All as per item No 13 abovebut LT UG cable of size 50 Sqmm 3.5 core
19All as per item No 13 above but LT UG cable of size 70 Sqmm 3.5 core
20All as per item No 13 above but LT UG cable of size 95 Sqmm 3.5 core
21All as per item No 13 above but LT UG cable of size 120 Sqmm 3.5 core
22All as per item No 13 above but LT UG cable of size 185 Sqmm 3.5 core
23All as per item No 13 above but LT UG cable of size 240 Sqmm 3.5 core
24M&L Earthing in replacementcomplete with galvanised steel earth plate electrode 60cmx60cmx6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI strip 32 x 6 mm as earth strip electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth strip encased inand including 40 mm dia GI "lightgrade" pipe from upper end of earth plate upto equipments,20 dia bore GI pipe "light grade" as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe andPCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS TMT bars 8mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as describedin electric plate of SSR Part I completeall as specified and directed and testing on completion. Note :- Ifthe desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
25Earthing in replacement complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level surrounded from all sides by 15 cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by mean of GI wire 4 mm dia by means of bolts, nuts check nuts and washers of GI or steel and connecting to earthing test point, main switch board, testing on completion including PCC cover and frame, PCC (1:3:6) type C-2 as in earthing pit, MS funnel with wire mesh GI pipe 20 mm dia light grade for watering and GI pipe 15 mm dia light grade for the protection of GI wire from earth pit to earth point complete including necessary excavation and earth work in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance n.exc 50 m all as specified as shown in electrical plate No 5 SSR Part-I.PCC chamber shall be constructed at least one metre away from the earth pit and GI pipe fittings for watering shall be provided up to chamber and cost of the same is deemed to be included in the rate of earthing. Note :- Ifthe desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
26Disconnecting the existing cable from Panel / Pole, preparing the end for jointing including all earth work, Supply and fixing Cable end termination heat shrinkable joint including sleeves suitable for LT XLPE cable of size 3.5 / 4 core 10 to 16 Sqmm
27All as per item No 26 abovebut size 25 to 50 Sqmm
28All as per item No 26 abovebut size 70 to 120 Sqmm
29All as per item No 26 abovebut size 150 to 185 Sqmm
30All as per item No 26 above but size 240 to 300 sqmm
31Disconnecting the existing cable from Panel / Pole, preparing the end for jointing including all earth work, Supply and fixing straight through heat shrinkable joint suitable for LT XLPE cable of size 3.5/4 core 10 to 16 sq mm
32All as per item No 31 abovebut size 25 to 50 Sqmm
33All as per item No 31 abovebut size 70 to 120 Sqmm
34All as per item No 31 abovebut size 150 to 185 Sqmm
35All as per item No 31 above but size 240 to 300 sqmm
36Supply & Fixingin replacement twin core, 6 sqmm nominal cross sectional areamultistrandedaluminium conductor cable, over all PVC sheathed, 1100 Volts grade heavy dutycable PVC insulatedand PVC sheathedcomplete all as specified.
37Supply & Fixing in replacement twin core, 10 sqmm nominal cross sectional areamultistrandedaluminium conductor cable, over all PVC sheathed, 1100 Volts grade heavy dutycable PVC insulatedand PVC sheathedcomplete all as specified.
38Supply, fixing, connecting andtesting in replacementMCCB 63 Amp 4 pole 25 KA 415 volts 50 Hz adjustablethermal & fixedmagnetic release with spreaderafter taking down old existing unserviceableMCCB complete all as directed.
39Supply, fixing, connecting andtestingin replacement MCCB 100 Amp 4 pole 25 KA 415 volts 50 Hzadjustablethermal & fixedmagnetic releasewith spreaderthermal magnetic release after taking down old existing unserviceableMCCB complete all as directed.
40Supply, fixing, connecting andtesting in replacement MCCB 125 Amp 4 pole 25 KA 415 volts 50 Hz adjustablethermal & fixedmagnetic releasewith spreaderafter taking down old existing unserviceableMCCB complete all as directed.
41Supply, fixing, connecting andtesting in replacement MCCB 160 Amp 4 pole 25 KA 415 volts 50 Hzadjustablethermal & fixedmagnetic releasewith spreaderafter taking down old existing unserviceableMCCB complete all as directed.
42Supply, fixing, connecting andtesting in replacementMCCB 200 Amp 4 pole 36 KA 415 volts 50 Hz thermal magnetic release with spreaderafter taking down old existing unserviceableMCCB complete all as directed.
43Supply, fixing, connecting andtestingin replacement MCCB 250 Amp 4 pole 36 KA 415 volts 50 Hz adjustablethermal & fixedmagnetic release with spreaderafter taking down old existing unserviceableMCCB complete all as directed.
44Supply, fixing, connecting andtestingin replacement MCCB 400 Amp 4 pole 36 KA 415 volts 50 Hzadjustablethermal & adjustable magnetic release with spreaderafter taking down old existing unserviceableMCCB complete all as directed.
45Supply, fixing, connecting andtestingin replacement MCCB 630 Amp 4 pole 50KA 415 volts 50 Hz adjustablethermal & adjustable magnetic release with spreaderafter taking down old existing unserviceableMCCB complete all as directed.
46S&F in replacementon load change over switch open execution of capacity 400 Amps , 4 pole , 415 volt , 50 Hz fixed in any type of existing LT panel/Feeder piller including taking out old existing unserviceable change over from panels etc complete all as directed
47S&F in replacementon load change over switch open execution of capacity 250 Amps , 4 pole , 415 volt , 50 Hz fixed in any type of existing LT panel/Feeder piller including taking out old existing unserviceable change over from panels etc complete all as directed
48Supply and fixing in replacement MCCB FP 125 Amps, 25 kA, 415 Volt AC, 50 Hz, complete with sheet metal enclosure of 1.6 mm thick MS sheet factory made with powder coat paint including connecting with existing system with existing cablling network including making good disturbed surfaces complete all as specified and directed. Note : The cost of suitable size fastner/Nut bolts required at site for fixing of cubical is deemed to beincluded in the quoted rate by the contractor.
49Supply and fixing in replacement double pole sheet metal enclosure made of 1.6 mm thick MS sheet factory made with powder coat painting including 01x MCB20 Amps 10 kAcomplete all as directed Note : The cost of suitable size clamp/Nut bolts required at site for fixing of enclosure on garden light post/wall is deemed to beincluded in the quoted rate by the contractor.
50Supply drawing, connecting and testing in replacement3 core, 1.5 Sqmm PVC insulated and PVC round sheathed` copper conductor (flexible ) industurial cable, 1100 Volts conforming to IS 694 in steel tubular poles from Junction box to street light fitting including providing suitable copper lugs all as specified and directed by Engr-in-charge.
51S&F in replacementwheather proof pole mountingPVC junction box, base and door of junction boxmade out of SMC having outside dimention333x233x120mm, inside dimention300x200x105mm , single door front openable provided withhinged cover and locking arrangements with 4 Nos aluminium bas bar 63 Amps, mounted on porcelin insulatorincluding M&L for MCB SP10 Amp -1No, fixed on box in Din rail complete with electrical connection fixed to pole with suitable sizeFI clamp nut bolts and washer including embossing/painting of danger notice of size not less than 10cm x 7.5cm with letters, figures and conventional skull and bones in signal red colour on front face of junction box body Complete all as directed by Engr-in-Charge
52Supply & fixing in replacement GI brackets made of 40 mm nominal bore GI pipemedium grade of required length not less than 1.5 M long, mounting brackets made out of Mild steel FI 40x6 mm of required shape ( two Nos) duly fitted with Mild steel nuts, bolts and washers and painting with two coats of synthetic enamelled paint over one coat of red oxide Zn chrome primer and fixed to pole / walls etc complete all as specified & directed by Engr-in-Charge.
53Supply and fixingin replacement CRCA MS sheet for LT panel having thickness 3.15 mm powder coated finish over one coat of red oxide on out side surface and painted in side with two coats of red oxide primer including all fixing acessories i.e. suitable size of hinge, nuts, bolts, washers, cutting and welding works etc complete all as directed by Engr -in-charge
54Supply and fixingin replacement Digital VAF+PF meter with RS 485 CL1 in LT panel including taking out old existing unserviceable meter from panels etc complete all as directed
55Supply and fixingin replacement of LED indication lampincluding taking down old unserviceable LED indication lamp from LT panel complete as specified and directed.
56M&L for Preparation of old painted surfaces and painting of LT steel tubular pole9 mtrs long from bottom to top with aluminium paint and painting to bottam up to 1.5 mtr height from top of PCC coping with synthetic enamel paint 2 coats in black and Yellow alternate strip including numbering in 8 cm height of number with white paint both paint aluminium /synthetic duly approved by engineer –in-Charge and complete all as directed and specified.
57Cleaning the existing painted surface of LT panel by scrapping, making good distrubed surfaces by applying putties on uneven surface to make it even and M&L for spray painting to LT panel of any size with two coat of synthetic enamel paint with desired colour over one coat of red oxide primer complete all as specified and directed.
58Material and labour disconnecting faulty / burnt end or portion of cable from LT panel / LT pole / main switch / changeover etc byremoving the cable from loop including necessary excavation & earth work , cleaning the surface area not less than 1 mtr surrounding the panel / pole, provision of suitable size of thimble, LT tap, relaying and reconnecting the cable by removing faulty/burnt portion of cable and preparing fresh terminals for 16 Sqmm 3.5/4 core to 240 Sqmm3.5 core of LT cable toLT Panel/pole/main switch/changeovercomplete all as directed.
59Supply & fixing in replacementautomatic street light timer panel 5 KWswitch using Infrared Sensor basedfor automatic switching of street lights based on LUX level of natural light. Required illuminance for switching ON is < 30 Lux and for switching OFF > 10 Lux level. The sensor (nature switch) alongwith suitable power contactors, Input (supply) MCB and output (load) MCB(s), support terminals should be enclosed in pole/ wall mountable enclosure made of rust proof, electric shock proof, termite proof and FR graded SMC junction box conforming to IP-54 degree of protection including mounting bracket, cable glands, openable doors with lock complete all as specified & directed by Engr-in-Charge.
60Disconnecting faulty 1.1 KVLT cables of any size and any lengthfrom both ends Hiring of cable fault detector machine to detect exact position of fault, removal of Fault,Re-connections and testing of cables after removal of fault including excavation, returung filling, Removal, relaying of cable protection cover etccomplete as specified and directed. Note :(a) 1.1KVLT cable & joints shall be measured and paid for seperately under respective items of schedule. (b)Contractor or his rep shall come to the site of breakdown within one hour of notification of breakdownalongwith fault locating machine and manpower.In case the rep or contractor shall not come to the site of breakdown and not to start attending breakdown within 1.00 hour a penalty of Rs 1000 per fault per hour will be imposed over contractor and will be deduct from his dues.
61Supplying and fixing in replacement 3 pole power contractor AC 3rating 40 Amp, 240 Volt AC complete all as specified and directed by Engr-in charge
62Supplying and fixing in replacement Astronomical Digital Timer Switch240 V AC complete all as specified and directed by Engr-in charge
63S&F in replacement outdoor luminaries post made of50mm dia GI Pipe (medium gradewith necessary accessories complete all as specified and directed Note Post hole &PCC in foundation shall be measured and paid in respective item of schedule.
64Material and labour for PCC1:2:4 type B1 using 20 mm graded stone aggregates formaking of foundation of post of oudoor luminaries complete all as specified and as directed by Engineer-in-Charge.
65Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning,filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm,
66M&L out door type busbar panel board (Dimention of Cubical/enclosure not less than 600mmx450mmx450mm) made out of3.15 mm thick MS sheet and MS angle section 50x50x6 mm factory made suitable for 3 phase 4 wire 415 Volt, 50 Hz, powder coat painted comprising of the following:- (a)FP, Aluminium bus bar 500 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators. (b) Incoming MCCB 250 Amps 25 KA, 415 Vots, 50 Hz, FP.– 1 No (c)LED Indicator lamp RYB - 01 set of three. (d) Platform of Panel. Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class "B", old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel.The platform shall be such that it is of a height 45 cm above the nearest road level.
67Deployment of manpower / tools / machinery etc for restringing of existingloose over head line having 5 Nos ACSR conductor and 01 Nos GI wire any size / type etc of existing LT pole including replacement of aluminium binding wire or suitable size carefully without damaging of insulator etc. complete all as specified and as directed by Engineer-in-Charge. Note:- 5 Run of ACSR conductor with 01 Run of GI wire shall be measured as 01 RM for payment.
68Deployment of manpower / tools / machinery etc for restringing of existingloose over head line having 4 Nos ACSR conductor and 01 Nos GI wire any size / type etc of existing LT pole including replacement of aluminium binding wire or suitable size carefully without damaging of insulator etc. complete all as specified and as directed by Engineer-in-Charge. Note:- 4 Run of ACSR conductor with 01 Run of GI wire shall be measured as 01 RM for payment.
69Trimming/pruning of the tree branches coming cross electric power head line LT feeder clearing the span and making the free from touching the tree branches complete all as specified and as directed by Engineer-in-Charge
70Supplying and fixing in replacement LT spacerin LT overhead line of ACSR conductor,shall be made ofhigh quality regid PVC,the spacer shall be water proof weather proof and shock proof the spacer shall also be suitable for use onboth horizental and vertically configuration of LT O/H lineACSR conductor 5 wire /4 wire system
71S&Fin replacement Aluminium conductor, steel reinforced (ACSR) of code name ferret/weaselon LT pole of size as ordered includingstringingandjointing for overhead line on poles including aluminiumbinding wire 14 SWG, jumpers, line tapes etc supplied and fixed in repairs including dismantling of old ACSR conductor fromLT poles complete all as specified and as directed by Engineer-in-Charge.
72S&F in replacementCross arms, bracings, supports, clamps and back plates fabricated from structural steel sections conforming to Fe-410-S grade including necessary nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape and size as directed and including applying two coats of aluminium paint (under & finishing coats) over a coat of red oxide zinc chromate primer on exposed steel surfaces, supplied and fixed in repairs, complete all as specified and as directed by Engineer-in-Charge.
73Supply and fixing in replacement 60 W LED street light fitting with mandatory driver set having pressure die cast aluminium housing with high efficiency LEDs as lighting source and lens embaded PC cover /IP lens, street lightshould haveIP 66 protection, impact resistance ofIK 07 , Lumen efficiency of LED not less than 110 lumen per wattsystem efficency ,power factor >0.95, THD<10% at Full load CRI> 70% ,street light should have built in potted electronic LED driver with , lower THD, open circuit protection , over voltage protection , surge voltage protection ,andprovided with company LOGO ingraved on housing of the street lightcomplete including taking down of oldUNSV fittings all as specified and directed by Engr -in-Charge. Note :-The contractor shouldtake approval of techincal specification ofluminaries and driver from department before procurement .
74Supply and fixing in replacement of 200 W LED flood fitting having epoxy powder coated die cast aluminium housing ADC12 in grey finish with elegantly designed heat sink for efficient thermal management , sturdiness & excellent corrosion resistant. PG9 gland is used for cable entry and provision for loopin -loopout , PC lens/IP lens with narrow /wide beam distribution and toughened glass fixed to housing withscrews, floodlightshould haveIP 66 protectionand impact resistance ofIK 07 , Lumen efficiency of LED not less than 120 lumen per wattsystem efficency ,power factor >0.95, THD<10% at Full load CRI> 70% ,flood light should have built in pottedelectronic LED driver with , lower THD, open circuit protection , over voltage protection , surge voltage protection ,andprovided with company LOGO ingraved on housing of the floodlightcomplete including taking down of oldUNSV fittings all as specified and directed by Engr -in-Charge. Note :-The contractor should take approval of techincal specification ofluminaries and driver from department before procurement .
75All as per itemSer No74above but 120 Watt & Lumen efficiency of LED not less than 110 lumen per watt system efficiency
76All as per itemSer No74above but 100 Watt & Lumen efficiency of LED not less than 110 lumen per watt system efficiency
77All as per itemSer No74above but50 Watt& Lumen efficiency of LED not less than 100 lumen per watt system efficiency
78Supply and errectionin replacement07 mtr continuously tapered hot dip galvanised Octagonal cross sectional pole with single dipping method having bottom 130 mm A/F and top 70 mm A/F 3 mm thick confirming to ASTM A 572 Gr with yield 450mpa cut and folded to form an octagonal section and welded in accordance with AWS for wind loading as per IS 875 part 3 1987.Poles shall be provided with base plate of size 225x225x12 mm which shall be free from any lamination or incursion with no cutting or welding on the pole after hot dip galvanising with single arm 1000 mm long bracket tilted to 150 degree from horizontal toward vertices suitable for mounting on the octagonal pole, of company recommendationand one no TPN Connecton 3 phase 4 wire 100 Amps, and one number MCB SP 6 Amps. A triangular flat MS plat of 6mm thick duly coated with GI shall be welded between cap of the octagonal pole and bracket. Welding work shall be done 250mm on bracket and 150 mm on pole"s cap including all RCC work type (1:2:4) type B-1 including 04 Nos foundation nut bolt and plate as per pole manufacturer"s drawing and earth work all as per requirement complete all as specified and directed. Note Cost of construction of RCC foundation including construction material, necessary earth work and excavatonas per manufacturer design forabove polecompleteall as required at site and as directed by Engr-in-charge are deemed to be included in the quoted rate.
79Supplying, transporting, erectingin replacement Steel tubular swaged poles type 410 SP-31 ( 9.0 metres long) complete with cast iron base plate, finial, taper plug, bolts, nuts and screws as specified, including necessary excavation and earth work , PCC 1:4:8 type D2 in foundations below pole, PCC 1:3:6 type C2 around poles and PCC 1:3:6 type C1 as in plinth block , disposal of surplus soil to a distance not exceeding 50 m and depositing where directed, the exposed surface of steel tubular poles shall be painted with two coat of aluminum paint over a coat of red oxide, embaded portion of the pole shall be painted with one coat of bituminous paint.05 Nos black and Yellow alternate strip with two coat of synthetic enamel paint shall be painted up to the the height of 1.5 Mfrom copping of the poleincluding numberingon pole in black colour synthetic enamel paint complete all as specified and directed.
80Supply and fix in replacement 25 WattLEDPost Toplanterns housing made of Die-cast aluminum spigot for mounting LED driver and spun aluminum canopy , epoxy powder coated matt black finish after phosphochromate treatment , high quality polycarbonate cover is used over LED moudule to enhance the lumen output & clear acrylic diffuser is used to provide overall glare free light , Powered by electronic integral , isolated poted electronic LED driver in ABS housing with APFC (SMPS based constanct current supply) with lower THD , output short/open circuit protection , Surge Voltage protection & other safety test as per IS 15885 Part-2/Sec-13 , IP 65 ,Lumen efficiency not less than 98 lumen per wattsystem efficency ,power factor >0.95, THD<10% at Full load CRI> 70%
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail