Tender For Repair Maint Of Lt Cable, Electrical Breakdown Incl Fault Detection, Localization And Rectification In Ug Network And Oh Conductor, Switch Gear Including Connected Items Area At East Of Mg Road And Adjoining Area Of Age E/M Ext (Elect) Und, lucknow-Uttar Pradesh

Military Engineer Services-MES has published Tender For Repair Maint Of Lt Cable, Electrical Breakdown Incl Fault Detection, Localization And Rectification In Ug Network And Oh Conductor, Switch Gear Including Connected Items Area At East Of Mg Road And Adjoining Area Of Age E/M Ext (Elect) Und. Submission Date for this Tender is 30-04-2024. Switch Gear Tenders in lucknow Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

43101943
Corrigendum : Tender For Repair Maint Of Lt Cable, Electrical Breakdown Incl Fault Detection, Localization And Rectification In Ug Network And Oh Conductor, Switch Gear Including Connected Items Area At East Of Mg Road And Adjoining Area Of Age E/M Ext (Elect) Und
Open Tender
Indian
Uttar Pradesh
lucknow
30-04-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Repair Maintenance Of Lt Cable, Electrical Breakdown Incl Fault Detection, Localization And Rectification In Ug Network And Oh Conductor, Switch Gear Including Connected Items Area At East Of Mg Road And Adjoining Area Of Age E/M Ext (Elect) Under Ge Em

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 23-Apr-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 30-04-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 90000.0 /-
Tender Value
INR 45 Lakhs /-

Attachment

FileName File Description File Size
3734c106-06a0-4c82-88d0-f7b382b66905.html Tender Notice 0 KB
BOQ_726789.xls Tender Document 0 KB
Tender15.pdf Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

NAME OF WORK : REPAIRMAINTENANCE OF LT CABLE, ELECTRICAL BREAKDOWN INCL FAULT DETECTION, LOCALIZATION AND RECTIFICATION IN UNDERGROUND NETWORK AND OVERHEAD CONDUCTOR, SWITCH GEAR INCLUDING CONNECTED ITEMS AREA AT EAST OF MG ROAD AND ADJOINING AREA OF AGE E/M EXT (ELECT) UNDER GE E/M LUCKNOW.
Sl. No. Item Description
1Excavation in trenches not exc. 1.5 m wide and not exc 1.5 mtr deep in soft / loose soil for laying / taking up / taking down of cables and getting out and levelling of bottom suface to required level all as specified and directed by Engineer- in- Charge.
2Returning filling in Including spreading, levelling, watering and well ramming using excavated soil in layers not exceeding 25 cm thick all as specified and directed.
3Removing excavated soil from site to a distance n. exc 50 mtrs away and depositing where directed at a level n. exc. 1.5 mtr above the starting point all as specified and directed by Engineer-in-Charge.
4Material and labour for dry river sand, washed and screened dry for cushioning to under ground cable in trenches below and around under ground cable including spreading and levelling complete as specified and directed . Note :- Punned thickness shall only be considered for payment
5M&L for laying well burnt old sizebricks, sub class "B" bricks, straight or curved on plan, laid flat with width equal to length of brick , laid dry over electric cable for protection complete all as specified & directed by Engr-in-Charge.
6All as per srl item No 6 here-in-before but using old bricks obtained under srl item No 1 here in before.
7M&L for demolition / cutting of road / path / hardstading / concrete in floor, etc for laying of cable complete all as directed at site by Engr-in-charge
8Material and labour for PCC1:2:4 type B-2 using 40 mm graded stone aggregates for filling of cutting of roads / path / hardstanding etc complete all as specified and as directed by Engineer-in-Charge.
9Deployment of tools & manpower for Boring of hole under road / pavement / hard standing or any other situation by manual means suitable for passing of 40 to 80 mm bore pipe and making good both ends all specified and directed
10M&L for 40 mm bore mild steel galvanised water tubing, light grade with all fittings and fixed to walls or laid onfloors / fixed to poles / or passing under road crossing, for protection of UG cable including taking out old pipe complete all as specified and directed by Engr-in-Charge.
11M&L for 50 mm bore mild steel galvanised water tubing, light grade with all fittings and fixed to walls or laid onfloors / fixed to poles / or passing under road crossing, for protection of UG cable including taking out old pipe complete all as specified and directed by Engr-in-Charge.
12M&L for 80 mm bore mild steel galvanised water tubing, light grade with all fittings and fixed to walls or laid onfloors / fixed to poles / or passing under road crossing, for protection of UG cable including taking out old pipe complete all as specified and directed by Engr-in-Charge.
13M&L for 100 mm bore mild steel galvanised water tubing, light grade with all fittings and fixed to walls or laid onfloors / fixed to poles / or passing under road crossing, for protection of UG cable including taking out old pipe complete all as specified and directed by Engr-in-Charge.
14Material & Laying, jointing and testing in replacement of LT under ground electric power cablecrossed linked polyethylene (XLPE)insulated, galvanised steel strip or wire armoured,ISI-7098 Marked, with aluminium conductor multi stranded , heavy duty 1100 Volts grade of size 10 sqmm cross sectional area, 2 core, complete all as specified laid in trenches / laid under floor or fixed naked on walls / on poles / in ducts / in GI pipes etc. with and including MS Clamps, nuts , bolts, washers, alumunium thimble, ferrule complete all as specified and directed. Note :-Excavation, earth work, sand cushioning, protection bricks /tiles /block andpipe shall be measured and paid separately under appropriate items.
15All as per Item No 14 but cable of size 16 Sqmm 2 core.
16All as per Item No 14 but cable of size 16 Sqmm 4 core.
17All as per Item No 14 but cable of size 25 Sqmm 4 core.
18All as per Item No 14 but cable of size 35 Sqmm 3.5 core.
19All as per Item No 14 but cable of size 50 Sqmm 3.5 core.
20All as per Item No 14 but cable of size 70 Sqmm 3.5 core.
21All as per Item No 14 but cable of size 95 Sqmm 3.5 core.
22All as per Item No 14 but cable of size 120 Sqmm 3.5 core.
23All as per Item No 14 but cable of size 185 Sqmm 3.5 core.
24All as per Item No 14 but cable of size 240 Sqmm 3.5 core.
25All as per item Srl No14 above but cable of cross sectional area 630 Sqmm , 1 core
26M&L for Earthing in replacement complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level surrounded from all sides by 15 cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by mean of GI wire 4 mm dia by means of bolts, nuts check nuts and washers of GI or steel and connecting to earthing test point, main switch board, testing on completion including PCC cover and frame, PCC (1:3:6) type C-2 as in earthing pit, MS funnel with wire mesh GI pipe 20 mm dia light grade for watering and GI pipe 15 mm dia light grade for the protection of GI wire from earth pit to earth point complete including necessary excavation and earth work in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance n.exc 50 m all as specified as shown in electrical plate No 5 SSR Part-I.PCC chamber shall be constructed at least one metre away from the earth pit and GI pipe fittings for watering shall be provided up to chamber and cost of the same is deemed to be included in the rate of earthing. Note :- Ifthe desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
27M&L for Earthing in replacementcomplete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI strip 32 x 6 mm as earth strip electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth strip encased inand including 40 mm dia GI "lightgrade" pipe from upper end of earth plate upto equipments,20 dia bore GI pipe "light grade" as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe andPCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS TMT bars 8mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as describedin electric plate of SSR Part I completeall as specified and directed and testing on completion. Note :- Ifthe desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
28M&L for Disconnecting the existing cable from Panel / Pole, removing the old end termination joint, preparing the end for jointing, supply and fix Cable end termination heat shrinkable joint including sleeves suitable for LT XLPE cable of size 3.5 / 4 core 10 to16 Sqmm and reconnecting the cable with panel etc.
29All as per item No 28 above but end termination joint sutable for cable of size 25 to 50 Sqmm
30All as per item No 28 above but end termination joint sutable for cable of size 70 to 120 Sqmm
31All as per item No 28 above but end termination joint sutable for cable of size 150 to 185 Sqmm
32All as per item No 28 above but end termination joint sutable for cable of size 240 to 300 Sqmm
33M&L for Disconnecting the existing cable from Panel / Pole, preparing the end for jointing including all earth work, Supply and fixing straight through heat shrinkable joint suitable for LT XLPE cable of size 3.5 / 4 core 10 to 16 Sqmm
34All as per item No 33 abovebut straight through joint sutable for cable of size 25 to 50 Sqmm
35All as per item No 33 abovebut straight through joint sutable for cable of size 70 to 120 Sqmm
36All as per item No 33 abovebut straight through joint sutable for cable of size 150 to 185 Sqmm
37All as per item No 33 abovebut straight through joint sutable for cable of size 240 to 300 Sqmm
38Disconnecting faulty 1.1 KVLT cables of any size and any lengthfrom both ends Hiring of cable fault detector machine to detect exact position of fault, removal of Fault,Re-connections and testing of cables after removal of fault including excavation, returung filling, Removal, relaying of cable protection cover etccomplete as specified and directed. Note :(a) 1.1KVLT cable & joints shall be measured and paid for seperately under respective items of schedule. (b)Contractor or his rep shall come to the site of breakdown within one hour of notification of breakdownalongwith fault locating machine and manpower.In case the rep or contractor shall not come to the site of breakdown and not to start attending breakdown within 1.00 hour a penalty of Rs 1000 per fault per hour will be imposed over contractor and will be deduct from his dues.
39Supply & Fix in replacement twin core, 6 sqmm nominal cross sectional area multistrandedaluminium conductor cable, over all PVC sheathed, 1100 Volts grade heavy duty cable PVC insulatedand PVC sheathed complete all as specified.
40Supply & Fix in replacement twin core, 10 sqmm nominal cross sectional area multistrandedaluminium conductor cable, over all PVC sheathed, 1100 Volts grade heavy duty cable PVC insulatedand PVC sheathed complete all as specified.
41Supply, fix connecting and testing in replacementMCCB 63 Amp 4 pole 25 KA 415 volts 50 Hzthermal magnetic release with spreader after taking down old existing unserviceable MCCB complete all as directed.
42Supply, fix connecting and testing in replacementMCCB 100 Amp 4 pole 25 KA 415 volts 50 Hzthermal magnetic release with spreader after taking down old existing unserviceable MCCB complete all as directed.
43Supply, fix connecting and testing in replacementMCCB 125 Amp 4 pole 25 KA 415 volts 50 Hzthermal magnetic release with spreader after taking down old existing unserviceable MCCB complete all as directed.
44Supply, fix connecting and testing in replacementMCCB 160 Amp 4 pole 25 KA 415 volts 50 Hzthermal magnetic release with spreader after taking down old existing unserviceable MCCB complete all as directed.
45Supply, fix connecting and testing in replacementMCCB 200 Amp 4 pole 36 KA 415 volts 50 Hzthermal magnetic release with spreader after taking down old existing unserviceable MCCB complete all as directed.
46Supply, fix connecting and testing in replacementMCCB 250 Amp 4 pole 36 KA 415 volts 50 Hzthermal magnetic release with spreader after taking down old existing unserviceable MCCB complete all as directed.
47Supply, fix connecting and testing in replacementMCCB 400 Amp 4 pole 36 KA 415 volts 50 Hzthermal magnetic release with spreader after taking down old existing unserviceable MCCB complete all as directed.
48Supply, fix connecting and testing in replacementMCCB 630 Amp 4 pole 50 KA 415 volts 50 Hzthermal magnetic release with spreader after taking down old existing unserviceable MCCB complete all as directed.
49Supply and fix in replacement double pole sheet metal enclosure made of 1.6 mm thick MS sheet factory made with powder coat painting including 01x MCB20 Amps 10 kAcomplete all as directed Note : The cost of suitable size clamp / Nut bolts required at site for fixing of enclosure on garden light post / wall is deemed to beincluded in the quoted rate by the contractor.
50S&F in replacementon load change over switch open execution of capacity 400 Amps, 4 pole , 415 volt , 50 Hz fixed in any type of existing LT panel / Feeder piller including taking out old existing unserviceable change over from panels etc complete all as directed
51S&F in replacementon load change over switch open execution of capacity 250 Amps, 4 pole, 415 volt , 50 Hz fixed in any type of existing LT panel / Feeder piller including taking out old existing unserviceable change over from panels etc complete all as directed
52Supply and fix in replacement MCCB FP 125 Amps, 25 kA, 415 Volt AC, 50 Hz, thermal magnetic release complete with sheet metal enclosure of 1.6 mm thick MS sheet factory made with powder coat paint including connecting with existing system with existing cablling network including making good disturbed surfaces complete all as specified and directed. Note : The cost of suitable size fastner / Nut bolts required at site for fixing of cubical is deemed to beincluded in the quoted rate by the contractor.
53Supply, fix connecting and testingin replacement MCB6-32 Amps, SP 10KA after taking down old existing un serviceableMCB complete all as directed.
54Supply, fix, connecting andtestingin replacement MCB6-32 Amps, DP 10KA after taking down old existing un serviceableMCB complete all as directed.
55Supply, fix connecting andtesting in replacement MCB 63 Amp 4 pole 10KA after taking down old existing un serviceableMCB complete all as directed.
56Supply, fix connecting and testing in replacement isolator 100 Amps, FP after taking down old existing un serviceableisolator complete all as directed.
57Deployment of manpower / tools / machinery etc for restringing of existingloose over head line having 5 Nos ACSR conductor and 01 Nos GI wire any size / type etc of existing LT pole including replacement of aluminium binding wire or suitable size carefully without damaging of insulator etc. complete all as specified and as directed by Engineer-in-Charge. Note:- 5 Run of ACSR conductor with 01 Run of GI wire shall be measured as 01 RM for payment.
58Deployment of manpower / tools / machinery etc for restringing of existingloose over head line having 4 Nos ACSR conductor and 01 Nos GI wire any size / type etc of existing LT pole including replacement of aluminium binding wire or suitable size carefully without damaging of insulator etc. complete all as specified and as directed by Engineer-in-Charge. Note:- 4 Run of ACSR conductor with 01 Run of GI wire shall be measured as 01 RM for payment.
59Deployment of manpower / tools / machinery etc for trimming / pruning of the tree branches coming cross electric power head line LT feeder clearing the span ( 30 to 35 metre long) and making the free from touching the tree branches complete all as specified and as directed by Engineer-in-Charge
60Supplying and fix in replacementLT spacerin LT overhead line of ACSR conductor, shall be made ofhigh quality regid PVC,the spacer shall be water proof weather proof and shock proof the spacer shall also be suitable for use on both horizental and vertically configuration of LT O/H lineACSR conductor 5 wire / 4 wire system complete.
61Material and labour disconnecting faulty / burnt end or portion of cable from LT panel / LT pole / main switch / changeover etc byremoving the cable from loop including necessary excavation & earth work, cleaning the surface area not less than 1 mtr surrounding the panel / pole, provision of suitable size of thimble, LT tap, relaying and reconnecting the cable by removing faulty / burnt portion of cable and preparing fresh terminals for 16 Sqmm 3.5 / 4 core to 240 Sqmm3.5 core of LT cable toLT Panel / pole / main switch / changeovercomplete all as directed.
62S&F in replacement Aluminium conductor, steel reinforced (ACSR) of code name ferret / weaselon LT pole of size as ordered including stringing and jointing for overhead line on poles including aluminiumbinding wire 14 SWG, jumpers, line tapes etc supplied and fixed in repairs including dismantling of old ACSR conductor from LT poles complete all as specified and as directed by Engineer-in-Charge.
63S&F in replacementCross arms, bracings, supports, clamps and back plates fabricated from structural steel sections conforming to Fe-410-S grade including necessary nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape and size as directed and including applying two coats of aluminium paint (under & finishing coats) over a coat of red oxide zinc chromate primer on exposed steel surfaces, supplied and fixed in repairs, complete all as specified and as directed by Engineer-in-Charge.
64Supplying and fix in replacement Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle,two galvanised iron washers and one galvanised iron nut, 100mm height, 65mm dia for 1100 volts grade
65S&F in replacement Shackle type, porecelain, vitreous, white, brown or green insulator including galvanised mildsteel straps, washers, insulator bolts, washers and nusts working pressure in volts 1100 Voltsheight 75 mm, max dia 90 mm,galvanised steel fittings, section of straps 31 x 3mm, dia of bolts 12 mm complete all as specified and directed.
66Supplying, transporting, erectingin replacement Steel tubular swaged poles type 410 SP-31 (9.0 metres long) complete with cast iron base plate, finial, taper plug, bolts, nuts and screws as specified, including necessary excavation and earth work , PCC 1:4:8 type D2 in foundations below pole, PCC 1:3:6 type C2 around poles and PCC 1:3:6 type C1 as in plinth block , disposal of surplus soil to a distance not exceeding 50 m and depositing where directed, the exposed surface of steel tubular poles shall be painted with two coat of aluminum paint over a coat of red oxide, embaded portion of the pole shall be painted with one coat of bituminous paint.05 Nos black and Yellow alternate strip with two coat of synthetic enamel paint shall be painted up to the the height of 1.5 Mfrom copping of the poleincluding numberingon pole in black colour synthetic enamel paint complete all as specified and directed.